Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC AIRPORT ROAD SKALZANGLING LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | ₹27.6 L Quoted ₹28.5 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹38.3 L+₹9.9 L (34.6%)Rejected-Finance BUDOOBAGH NOWPORA 0 KHANYAR SRINAGAR JAMMU KASHMIR 190003 | SRINAGAR | JAMMU AND KASHMIR | 190003 | ₹38.3 L+₹9.9 L (34.6%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹38.4 L+₹9.9 L (34.8%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹38.4 L+₹9.9 L (34.8%) | L3 | Rejected-Finance Other than L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not recommended since douments furnished by the firm are incomplete refer Para 1.5 of Manual on contracts DD and EMD in terms of Clouse 7 b of NIT has neither been uploaded nor received |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not recommended since douments furnished by the firm are incomplete refer Para 1.5 of Manual on contracts DD and EMD in terms of Clouse 7 b of NIT has neither been uploaded nor received |
| Sl No | Description | Qty | Unit | Top Mind Industries Pvt Limited L2 | national engineering L3 | M/S NANCY ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Labour only along with T&P for attending of complaint for day to day / daily complaints by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare parts like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line any where about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engr-in- Charge complete all as directed at site.
Note :- (i) Attending any number of complaints of same unit relating to FCU of different nature will be considered as one job.
(ii) Replacement of major items shall be measured and paid for separately under respective item of schedule 'A'.
(iii) Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc. will be completed round the clock by suitable trademen, Welder with suitable T & P including portable heating materials-01 No, Skilled Mechanic of CHS - 01 No, Plumber/Fitter with helper - 01 No and Supervisor - 01 No as per direction of Engr-in-Charge.
(iv) Job slip will be maintained by the Contractor Supervisor under supervision of concerned JE E/M and suitable communication shall be maintained through JE incharge round the clock.
(v) On not attending complaint within 48 Hours (2 days), a recovery of Rs 2000.00 will be effected. In addition, the expenditure incurred for rectification of complaint/ defect by any other means will also be recovered from the payment due to the Contractor. | 408 | Each Job | 100 ₹40,800 Lowest | 1,900 ₹7,75,200 | 300 ₹1,22,400 |
| 2.00 | Dismantling of burner assembly of CHS and removing side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 4.00 lakh kilo/cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by means of welding and packing the burner sides with asbestos/rope to avoid leakage of burn gases or any other repair required at site and reassembling/ testing the same, complete all as specified and/ or as directed by Engr-in-Charge. | 10 | Each Job | 25,000 ₹2,50,000 | 24,000 ₹2,40,000 | 6,500 ₹65,000 Lowest |
| 3.00 | All as per Srl Item No. 2.00 above, but for 3.0 Lakh Kilo/Cal/Hr. | 6 | Each Job | 30,000 ₹1,80,000 | 19,000 ₹1,14,000 | 6,500 ₹39,000 Lowest |
| 4.00 | All as per Srl Item No. 2.00 above, but for 0.5-2 Lakh Kilo/cal/Hr. | 10 | Each Job | 30,000 ₹3,00,000 | 19,000 ₹1,90,000 | 10,000 ₹1,00,000 Lowest |
| 5.00 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth and getting it out for laying of UG cable / MS Pipes in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge. | 185 | Cum | 10 ₹1,850 Lowest | 150 ₹27,750 | 90 ₹16,650 |
| 6.00 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge. | 165 | Cum | 10 ₹1,650 Lowest | 60 ₹9,900 | 10 ₹1,650 Lowest |
| 7.00 | Removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and/or as directed by Engr-in-Charge. | 20 | Cum | 10 ₹200 Lowest | 60 ₹1,200 | 10 ₹200 Lowest |
| 8.00 | Supply and fix in replacement sequence controller suitable for 4 lakh kilo/hr with burner rod assembly including testing, complete all as specified and/or as directed by Engr-in-Charge. | 2 | Each | 7,500 ₹15,000 | 4,000 ₹8,000 | 2,500 ₹5,000 Lowest |
| 9.00 | Supply and fix in replacement sequence controller suitable for 3.0 lakh kilo/hr with burner rod assembly including testing, complete all as specified and/or as directed by Engr-in-Charge. | 2 | Each | 7,500 ₹15,000 | 4,000 ₹8,000 | 2,500 ₹5,000 Lowest |
| 10.00 | Supply and fix in replacement sequence controller suitable for 0.5 to 2.0 lakh kilo/hr with burner rod assembly including testing, complete all as specified and/or as directed by Engr-in-Charge. | 4 | Each | 7,500 ₹30,000 | 4,000 ₹16,000 | 2,500 ₹10,000 Lowest |
Tender Value
₹60.5 L
EMD Value
₹1.2 L
Closing Date
8 Aug 2026, 6:00 pmClosed
CWE, HQ 138 WE
CWE, HQ 138 WE
MAINTENANCE/ SERVICING AND ATTENDING DAY TO DAY COMPLAINTS OF CENTRAL HEATING PLANTS, HOT WATER BOILERS, STANDALONE ALONG WITH ACCESSORIES AT TRANSIT CAMP AND RINCHEN AUDITORIUM UNDER AGE E/M-I OF GE 865 EWS
2026_MES_777799_1
138WE/L-69/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE 865 EWS
₹1.2 L
Yes
12 Sept 2026
11 Jul 2026
15 Aug 2026
11 Jul 2026
8 Aug 2026
1 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour only along with T&P for attending of complaint for day to day / daily complaints by employed skilled staff, checking the serviceability of fan coil unit of any capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare parts like Gasket, Teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line any where about the premices to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / Heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engr-in- Charge complete all as directed at site.
Note :- (i) Attending any number of complaints of same unit relating to FCU of different nature will be considered as one job.
(ii) Replacement of major items shall be measured and paid for separately under respective item of schedule 'A'.
(iii) Any nature of complaint related with FCUs, radiators, bursting/cracking/leakage of MS pipe lines, replacement of valves etc. will be completed round the clock by suitable trademen, Welder with suitable T & P including portable heating materials-01 No, Skilled Mechanic of CHS - 01 No, Plumber/Fitter with helper - 01 No and Supervisor - 01 No as per direction of Engr-in-Charge.
(iv) Job slip will be maintained by the Contractor Supervisor under supervision of concerned JE E/M and suitable communication shall be maintained through JE incharge round the clock.
(v) On not attending complaint within 48 Hours (2 days), a recovery of Rs 2000.00 will be effected. In addition, the expenditure incurred for rectification of complaint/ defect by any other means will also be recovered from the payment due to the Contractor. | 408 | Each Job | - | - |
| 2 | Dismantling of burner assembly of CHS and removing side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity 4.00 lakh kilo/cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by means of welding and packing the burner sides with asbestos/rope to avoid leakage of burn gases or any other repair required at site and reassembling/ testing the same, complete all as specified and/ or as directed by Engr-in-Charge. | 10 | Each Job | - | - |
| 3 | All as per Srl Item No. 2.00 above, but for 3.0 Lakh Kilo/Cal/Hr. | 6 | Each Job | - | - |
| 4 | All as per Srl Item No. 2.00 above, but for 0.5-2 Lakh Kilo/cal/Hr. | 10 | Each Job | - | - |
| 5 | Excavation in trenches not exc. 1.5 m wide and not exc. 1.5 m in depth and getting it out for laying of UG cable / MS Pipes in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge. | 185 | Cum | - | - |
| 6 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and/or as directed by Engr-in-Charge. | 165 | Cum | - | - |
| 7 | Removing surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and/or as directed by Engr-in-Charge. | 20 | Cum | - | - |
| 8 | Supply and fix in replacement sequence controller suitable for 4 lakh kilo/hr with burner rod assembly including testing, complete all as specified and/or as directed by Engr-in-Charge. | 2 | Each | - | - |
| 9 | Supply and fix in replacement sequence controller suitable for 3.0 lakh kilo/hr with burner rod assembly including testing, complete all as specified and/or as directed by Engr-in-Charge. | 2 | Each | - | - |
| 10 | Supply and fix in replacement sequence controller suitable for 0.5 to 2.0 lakh kilo/hr with burner rod assembly including testing, complete all as specified and/or as directed by Engr-in-Charge. | 4 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TenderL692627.pdf
Tender Documents • 1.10 MB
BOQ_871108.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .