Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | Admitted-Finance |
| 3 | Admitted-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | Admitted-Finance |
Tender Value
₹43 L
EMD Value
₹96,000
Closing Date
26 Sept 2024, 6:00 pmClosed
GE(I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS AND REPLACEMENT OF CONTROL SWITCH GEAR ELECTRIC CONTROL VFD AUTOMATION SYSTEM SCALE PREVENTER AT RCI UNDER GE I RND RCI HYDERABAD
2024_MES_671529_1
8984
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE(I) R AND D RCI
MES enlisted Class D category c i and Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹96,000
Yes
10 Oct 2024
5 Sept 2024
28 Sept 2024
5 Sept 2024
26 Sept 2024
19 Sept 2024
Amount
Disconnecting the unserviceable VFD panel from the existing position, repair, fix, connecting & testing of DANFOS VLT 6000 HVAC 5.5 KW / 7.5 KW VFD drive complete all as specified and directed.
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of Radar Seekar Lab for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting and removing the unserviceable fan contactors from existing position and replace with new Fan Contactors in repairs all as specified and directed
Disconnecting and removing the unserviceable fan MCCB from its existing position and replace with new Fan MCCB in repairs all as specified and directed
Disconnecting electrically and mechanically the condensor fan motor from the existing position and rewinding, varnishing, insulation, ovening, greasing to the condensor fan motor, replacing of bearings all as specified and directed.
Disconnecting and removing the unserviceable drier filter from its existing position and replace with new Drier Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable external oil filter from its existing position and replace with new External Oil Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable ball valve from its existing position and replace with new Ball Valve in repairs all as specified and directed
Disconnecting and removing the unserviceable screw compressor oil from compressor and replace with new Screw Compressor Oil in repairs all as specified and directed
Disconnecting and removing the unserviceable temperature sensor from its existing position and replace with new Temperature Sensor in repairs all as specified and directed
Inspection charges for testing, programming, commissioning etc for AC plant at Radar Seekar Lab
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of EHSV Lab for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting and removing the unserviceable fan contactors from existing position and replace with new Fan Contactors in repairs all as specified and directed
Disconnecting and removing the unserviceable fan MCCB from its existing position and replace with new Fan MCCB in repairs all as specified and directed
Disconnecting electrically and mechanically the condensor fan motor from the existing position and rewinding, varnishing, insulation, ovening, greasing to the condensor fan motor, replacing of bearings all as specified and directed.
Disconnecting and removing the unserviceable liquid line paper filter from its existing position and replace with new Liquid Line Paper Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable compressor oil filter from its existing position and replace with new Compressor Oil Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable EXV motor from its existing position and replace with new EXV Motor in repairs all as specified and directed
Disconnecting and removing the unserviceable EXV cable from its existing position and replace with new EXV Cable in repairs all as specified and directed
Disconnecting and removing the unserviceable temperature sensor from its existing position and replace with new Temperature Sensor in repairs all as specified and directed
Disconnecting and removing the unserviceable liquid line temperature sensor from its existing position and replace with new Liquid Line Temperature Sensor in repairs all as specified and directed
Disconnecting and removing the unserviceable control fuses from its existing position and replace with new Control Fuses in repairs all as specified and directed
Disconnecting and removing the unserviceable flow switch from its existing position and replace with new Flow Switch in repairs all as specified and directed
Disconnecting and removing the unserviceable CLD display from its existing position and replace with new CLD Display in repairs all as specified and directed
Disconnecting and removing the unserviceable compressor module from its existing position and replace with new Compressor Module in repairs all as specified and directed
Disconnecting and removing the unserviceable EXV module from its existing position and replace with new EXV Module in repairs all as specified and directed
Disconnecting and removing the unserviceable main chiller module from its existing position and replace with new Main Chiller Module in repairs all as specified and directed
Disconnecting and removing the unserviceable compressor contactors from its existing position and replace with new Compressor Contactors in repairs all as specified and directed
Inspection charges for testing, programming, commissioning etc for AC plant at EHSV Lab
Disconnecting and removing and replacing of the following unserviceable items from the Chiller of Q&R Lab for smooth functioning complete all as specified and directed by the Engr-in-Charge.
Disconnecting and removing the unserviceable fan contactors from existing position and replace with new Fan Contactors in repairs all as specified and directed
Disconnecting and removing the unserviceable fan MCCB from its existing position and replace with new Fan MCCB in repairs all as specified and directed
Disconnecting electrically and mechanically the condensor fan motor from the existing position and rewinding, varnishing, insulation, ovening, greasing to the condensor fan motor, replacing of bearings all as specified and directed.
Disconnecting and removing the unserviceable drier filter from its existing position and replace with new Drier Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable external oil filter from its existing position and replace with new External Oil Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable internal oil filter from its existing position and replace with new Internal Oil Filter in repairs all as specified and directed
Disconnecting and removing the unserviceable screw compressor oil from compressor and replace with new Screw Compressor Oil in repairs all as specified and directed
Disconnecting and removing the unserviceable temperature sensor from its existing position and replace with new Temperature Sensor in repairs all as specified and directed
Disconnecting and removing the unserviceable TPCM board from its existing position and replace with new TPCM Board in repairs all as specified and directed
Inspection charges for testing, programming, commissioning etc for AC plant at Q&R Lab
Supply and re-filling of Refrigerant gas R-134A / R-22 / 407 complete all as directed.
omsai thermax engineers (BID ID -3114893)
M/S GDR CONSTRUCTIONS (BID ID -3114725)
BHAGYARAM ENTERPRISES (BID ID -3114428)
vvcenterprises (BID ID -3114665)
L and S ENTERPRISES (BID ID -3114729)
Maruthi international (BID ID -3114446)
SRI SAI ENTERPRISES (BID ID -3114561)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .