Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹33.6 L+₹4.6 L (16.0%)Rejected-AOC | L2 | Rejected-AOC Not Being Lowest | |
| 3 | L3₹36.4 L+₹7.5 L (25.7%)Rejected-AOC WZ 199 LAJWANTI GARDEN GALI NO 4 NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC Not Being Lowest | |
| 4 | L4₹40.7 L+₹11.7 L (40.4%)Rejected-AOC PLOT NO 79 SIS PARK DICHAON ENCLAVE PP2914 NAJAFGARH SOUTH WEST DELHI NEW DELHI 110043 | WEST DELHI | DELHI | 110043 | L4 | Rejected-AOC Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
8 Jul 2024, 6:00 pmClosed
GE (CENTRAL) DELHI CANTT-10
GE (CENTRAL) DELHI CANTT-10
REPAIR/ REPLACEMENT OF TILING, JOINERIES, SANITARY FITTINGS, PLASTERING, ROOF TREATMENT AND COMPLETE GI FITTINGS WITH WATER TANK FITTING AND CERTAIN MISC B/R WKS INCLUDING REPAIR/ REPLACEMENT OF UNSV PARTS OF LT PANEL INCLUDING SUB MAIN WIRING, EARTH
2024_MES_658828_1
GE/C-19/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹1 L
Yes
10 Sept 2024
10 Jun 2024
10 Jul 2024
10 Jun 2024
8 Jul 2024
24 Jun 2024
10 Jun 2024 - 24 Jun 2024
Amount
M&L for chipping out spilled and loose concrete cover and derusting steel reinforement of concrete column, beam, slab, chajjas, parapets and the like as directed upto 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforecement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guiniting mix using one part of OPC 53 grade and two part of gaggar sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out upto 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforecement all concrete surfaces shall be throughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. Note rate quoted up to G+8 bldg including scaffolding.
M&L for preparation of old/new decoreated external wall surface by mechanised sander with Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible, again sand papering thus making surface smooth and applying two coats of cement base paint on walls complete all as specified and all as directed by Engr-in-Charge . Note :- The prepration of surfaces stage shall be got approved from GE before applying the finishes. Note rate quoted up to G+8 bldg including scaffolding
Complete removal exising teratment from old surface of wall by scrubbing with hard brushing, brooming down or steel wire brushing scraping down smook soot mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water & applying two coat of oil bond distemper over one coat of putty complete all as specified and directed.
M&L for prepration of old plstered surfaces of wall and applying two coat of white wash complete all as specified and all as directed by Engineer in charge .
M&L for Preparation of old painted surfaces of wood based surfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed. Note rate quoted up to G+8 bldg including scaffolding
Taking down cement plaster on brick walls, or stone walls / ceilings etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. Note rate quoted up to G+8 bldg including scaffolding
M&L for renderning 15 mm thick in CM 1:4 on any faces of brick/concrete surfaces finished even and fair with out using extra cement complete all as specified. Note rate quoted up to G+8 bldg including scaffolding
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces of walls finished even and smooth without using extra cement complete all as specified and as directed. Note rate quoted for G+5 bldg
M&L for prepration of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed . Note rate quoted up to G+8 bldg including scaffolding
M&L for preparation of newly plastered surfaces and applying two coats of Oil bound distemper over one coat of wall putty on newly plastered surface over a coat of primer.
M & L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement incl scafolding etc, complete all as specified.
M&L for prepration of newly plstered surfaces of ceiling and applying two coat of white wash complete all as specified and all as directed by Engineer in charge .
Demolition of cement concrete (reinforced) in any position and in any description such as col , post complete all as specified and as directed.
S&F precast cement concrete Type B0 1:2:4 (12.5 mm graded aggregates) louvres and jallies, 50mm thick set in CM (1:4) (measured solid), including all mouldings precast RCC coping/post of size 600x100x50 mm suitable for fixing of RCC Jallies in vertically & horizontally complete all as specified and directed.
M & L for removal of plant growth by injection with chemical glyphosphate solution (4 % concentration) @ 20 ml or till refuse by cutting or injection in stem of plants or roots at 30 mm. The area shall then be sprayed with solution 25 ml glyphosphate (4% conc) diluted with 1 ltr of water. The size of block shall be of 2 Qtrs on each floor and vary in number of floors. All roots of plants shall be removed completely and making good the disturbed surface with PCC 1:2:4 type B0 and painted with cement base or acrylic paint all as specified and directed by Engr-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete. Note rate quoted up to G+8 bldg including scaffolding .
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete. Note rate quoted up to G+8 bldg including scaffolding.
S & F 100 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding
S & F 75 mm bore cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified & directed. Note rate quoted up to G+8 bldg including scaffolding
S&F in repairs PVC (SWR) bends of any radius ( 110mm bore) including jointing with solvent cement complete all as specified.
S&F in repairs PVC (SWR) bends of any radius ( 75mm bore) including jointing with solvent cement complete all as specified.
S&F in repairs PVC (SWR) vent cowl of 110 mm bore.
S&F in repairs PVC (SWR) vent cowl of 75 mm bore.
Complete removal of existing old treatment on surface from walls with machenical scraper (machine) complete all as specified and directed.
M& L a coat of alkali resistant primerover alread prepred surface of walls complete all as specified and directed.
M& L for preparing the entire surface with applying 2-3 mm thick birla/ JK wall care putty on walls surface finished even and smooth complete all as specified and directed.
M& L for applying two coats of oil bound distemper on wall surface with roller brush complete all as specified and directed.
M & L preparing old surface including washing, rubbing, filling holes,and uneven surface finishing old surfaces even and smooth with ,and surface shoulld be even and smooth applying one coat of oil bound distemper on wall surfaces with roller brush of complete all as specified.
Complete removal exising treatment of old/ new surfaces of wall scrubbing by machenical scrapper (machine) with hard brushing ,brooming down or steel wire brushing scraping down smook root mould moss and efforescent salts and treating oil and greasy spots as applicable and washing with water and applying Two coats of weather proofing exterior acrylic emulsion paint of approved make over one coat of primer from the same manufacturer with roller brush complete all as specified and directed. Note: For Item No 2, 3, 26 to 30 will be operated with spary machine as recommended by authorized applicator.
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) complete all as specified.
M&L for Plain, solid, straight chowkats and frames made of 2nd class hard wood (sal), wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed,complete all as specified and as directed by Engineer-in-Charge.
S&F for 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
M&L for 35 mm thick 2nd class hard wood glazed and skelton door shutter, factory made, open rebated and prepared to receive glass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc size of member as specified in SSR Part I Section 8 clause 20(a) and fixed to chowkat, complete all as specified.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and as directed.
S & F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube as per per specification
S&F 150mm long extruded alumiunium alloy handle fabricated type anodized (D type).
S&F 100 mm long (size) butt hinges medium weight, cold rolled, mild steel, complete all as specified.
S&F for 150 mm size aluminium, anodised barrel tower bolts of extruded section and fixed to shutter complete.
S&F for MS 300mm size, door spring type rat tail rod pattern springs including roller and roller plate complete.
S&F in repair for 100 mm size long mortice lock vertical type ,4 levers with key in duplicate, brass body with brass two nos handle fixed in shutters with screw complete all as specified.
Supply & fix two legged aluminium floor door stopper with rubber shoe 140mm long complerte all as specified and directed by Engineer-in-Charge.
S&F for galvanized stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm dia fixed with stainless steel wire staples including beading complete all as specified and as directed .
Hacking out old broken glass of any thickness size quality or description frame wooden frames /Aluminium frame fixed with wooden beads/aluminium beads and M&L 5.5 mm thick sheet galss ordinary quality and glazing with wooden bead/aluminium beads, complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete, all as specified and as directed.
3 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc 0.50 sqm in each pane complete, all as specified and as directed.
3 mm thick frosterd glass ordinary quality and glazing with oil putty in squares not exc 0.50 sqm in each pane complete, all as specified and as directed.
S & Fin repair 1000 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I.
S & F in repair 500 ltr capacity three layer white colour rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling old water tank all as specified in SSR Part I I.
Taking down chowkhat or frame not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame)
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded Complete all Specified and directed.
All as per Srl item No 51 above but without glazing bars.
S&F for Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165
Demolition of cement concrete (Un reinforced) in ground floors n.exc 15cm thick (above or below grnd level) complete all as specified.
M & L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection laid in bays & surfaces finished fair and even without using extra cement, complete all as specified.
S & F glass dividing strips, 55mm wide and 4mm thick and inserted in position to conform to design, complete all as specified.
M&L for PCC( 1:3:6 ) type C-2 using 20mm graded stone as in padding on roof correction of slope and roof kerbs all as specified and directed.
M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed. Note: The application shall be executed on any type of surface and on horizontal/Vertical areas.
Taking up or down steel tubing 15 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified.
S & F 15 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified.
Fixing only 15 mm water tubes, any grade, to walls and ceilings or laying in floors in repairs complete all as specified.
Taking up or down steel tubing 20 mm bore, and connections, including cleaning for re-fixing or removal to store in repairs complete all as specified.
S & F 20 mm bore, steel water tubing, medium grade, galvanized, with all fitting and fixed complete to walls and ceiling or laid into floor in repairs complete all as specified.
Fixing only 20 mm water tubes, any grade, to walls and ceilings or laying in floors in repairs complete all as specified.
M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge. Notes for item No 30, 58 AND 65: (a) The work shall be executed through authorised applicator of manufacturer only. (b) Authrised Applicator shall be approved by GE before starting of work. (c) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (d) MOU with authorized applicator will be submitted successful L1 bidder after opening of Financial Bid within a fixed time frame of 7 days otherwise tender will be cancelled. (d) A guarantee amount of 5% of contract of work done for item No 30, 58 & 65 of BOQ will be retained for 5 years of the completion of work.
Disconnecting existing tanks of cap 1000 ltrs, setting aside (or lower ing if required) for repairs, cleaning, etc. and hoisting if required re- connecting and re-fixing in position and Cleaning and removing all scale and dirt, etc. from tanks and form mouths of circulating pipes, etc.
Demolition of brick work built in cement mortar incl all quoins, arches, pillars etc Complete all as specified.
M&L for brick work with sub class 'B' bricks old size bricks strainght or curved on plan exc 6m mean radius built in CM 1 : 4 complete all as specified.
Taking up or down steel tubing and connections 25 mm bore including cleaning for refixing or removal to store.
S&F 25mm bore, GI tubing, medium grade with all fittings for fixed to walls, ceilings or laid in floors complete as specified and directed.
Refixing of Old steel tubing and connections in new or old position (Walls, ceiling floors, etc.) of 25mm bore.
S & F in repairs 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
S & F in repairs PVC connections 15mm size with PTMT nuts of length 450mm.
S & F in repairs 15mm bore Bib taps chromium plated, cast opper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F in repairs, Vitreous China wash basin, white, flat back of size 550mmx400mm excluding taps, but including waste coupling, waste pipe, chain and plug and porcelain stopper and brackets etc. complete as specified and directed.
S&F for waste fittings, 32 mm bore , PTMT (half or full threated).( Minimum weight 32 mm-45gms/40mm-60 gms) ,complete all as specified and directed.
S & F in repair ,vitreous china wash down water closet pan (pedestal pattern)white with P orS trap incl flushing pipe ,seat & PVC seat cover( white)closed pattern with flat bottom & cover brass chromium plated hinging device ,incl connection to drain and to flushing pipe,antisyphonage pipe etc complete .
S & F in repair ,vitreous china squatting pan (Orissa pattern) of size 580x 440 mm white with integral foot rest,incl 'P' or 'S' trap & front or back inlet complete all as specified.
PVC valveless, syphonic action type, flushing cistern of 10 ltrs capacity , low level, white, with inlet, ball valve, float and handle including brackets complete, all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tile to store and rubbish off the premises complete, all as specified and as directed.
Glazed ceramic coloured / printed tiles 350 cm x 250cm x 7 mm/450 x 300 x 7 mm thick as in vertical surfaces such as dado, skirting set jointed in neat cement slurry including pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Non skid ceramic coloured tiles area of each tiles (Square / rectangular) exc 0.06 sqm but n. exc 0.11 sqm 7 to 8 mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 complete, all as specified and as directed.
Non skid ceramic coloured tiles area of each tiles (Square / rectangular) exc 0.18 sqm but n. exc 0.38qm 7 to 8 mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 complete, all as specified and as directed.
M&L for Kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete 15 mm thick screed bed in cement mortar 1:6 complete, all as specified and as directed.
M&L for Kota stone slab 18-20mm thickin riser of steps , skirting, dado and pillar laid over cement screed and jointed with dado 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in flooring, finished even and smooth without using extra cement complete, all as specified and as directed.
M&L in repair for machine pressed precast concrete interlocking paver block with gray cement and no pigment, any shape and size confirming to IS- 15658 -2006 of 60mm thickness, M-40 Gde,Over and including 25mm thick layer of sand complete all as specified and directed.
Taking down carefully unserviceable LT panel including disconnecting of incoming and outgoing connections complete all as specified and directed.
Taking down carefully unserviceable distribution boards including disconnecting of incoming and outgoing connections complete all as specified and directed.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge.
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge.
S&F factory made epoxy powder coated Distribution board (MCCB DB) TPN 4 way vertical type, IP - 43 Protection made out of min 1.6 mm thick CRCA sheet, fabricated, metal double door fixed to wall and suitable for universal mounting and including 200 Amps rated copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removeable gland plated with knockouts and suitable for TPN MCCB 125/160 Amps as incomer and 12 SP or 04 Nos TP MCBS as outgoing complete all as specified and confirming to IS : 8623 complete all as specified and directed.
Supply and fix Sub main wiring complete with two runs of 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 1 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed.
M&L earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 25 x 4 mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised strip and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.
M&L providing protection pipe PVC or flexible pipe as reqd at site to out going cables, cleaning of LT panel boards with air blower cleaning inside, dressing in proper alignment, replacement of rusted iron parts with new one with suitable size of angles/strips tightening of fixing bolts and nuts, providing thimbles to whole bunch of wires uniformly clean manner etc complete all as specified and directed.
Supply and Fix in replacement of 35W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
Supply and fix in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of making holes and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
S&F Fresh in replacement air fan motor of capacity 1/6 HP 230 volts, 50 Hz, AC supply suitable for 250/200 mm size Fresh air fan as per sample complete all as spd and directed.
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Schedule of Credit
a.k constructions
M/S MSD & Associate
M/S Parmod Johar
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .