Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Sept 2026, 6:00 pm
GE Bharatpur
GE Bharatpur
REPAIR/MAINTENANCE OF DG SETS, CERTAIN EQPTS, CLEANING OF OH TANKS, UG SUMPS, OPEN WELL AND REPAIRS TO MES INSTALLATIONS AT RMS DHOLPUR
2026_MES_786194_1
8658/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Bharatpur
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE Bharatpur
₹90,000
Yes
25 Aug 2026
25 Aug 2026
17 Sept 2026
25 Aug 2026
15 Sept 2026
8 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling Stone slabs in roofs, suspended floors, chajjas, landings, etc., any thickness, jointed in any mortar including cleaning of Mud in roofs, any thickness and demolition of existing PCC & plastering and leeping (whether full thickness removed or only a part there of including removing the demolished material 100 m away from site and disposal in low lying area complete all as specified. | 140 | Sqm | - | - |
| 2 | M&L Dholpur stone roof slabs, self faced 10cm to 15cm thick, 45cm to 60cm wide and upto 3.5m Long, hoisted and set, jointed and grouted and set in cement mortar 1:3, complete all as specified. | 100 | Sqm | - | - |
| 3 | M&L Dholpur stone roof slabs, self faced 10cm to 15cm thick, 45cm to 60cm wide and upto 3.5m Long, hoisted and set, jointed and grouted and set in cement mortar 1:3, Except Stone Slabs complete all as specified. | 40 | Sqm | - | - |
| 4 | M&L for 50 mm thick plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in floors and paving on stone slabs in roofs including finished even and fair without using extra cement complete all as specified. | 140 | Sqm | - | - |
| 5 | M&L for screed bed or bedding layer 15 mm thick in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified. | 140 | Sqm | - | - |
| 6 | M&L for the surfaces prepration which are to receive the coating or treatment must be free from oil, laitance, grease, wax, dirt or any other form of foreign material adhering on it before the waterproofing job started. Dust free the surface, including removing of existing treatment/ old felt/ loose plaster/ concrete etc. and repair with polymer mortar by adding bonding agent (SBR). Repairing of slab, parapet wall junction, cracks and other large blowholes by open in "V" shapes & filling by polymer mortar or putty followed by fiber mesh tape with SBR in conjunction with cement complete all as specified.
Make : M/s Sika India Pvt Ltd/Fosroc/Pidilite Dr Fixit or Equivalent. | 160 | Sqm | - | - |
| 7 | M&L for applying 3 coats of one component polyurethane based liquid applied membrane with improved water ponding resistance, excellent UV resistance, good crack bridging capacity Elongation at break ~300 % (Free film, 14days, +30 °C) (ASTM D412) Tensile adhesion strength ≥ 1.5 N/mm2 (ASTM D4541)Tear strength ~20 N/mm (Free film, 14 days, +30 °C) (ASTM D624) Solar Reflectance Index 106 (ASTM E1980-19) Water resistance No blisters or peeling when subjected on top of concrete.Firstly Priming Coat consumption @ .3 kg/Sqm with polyurethane based water proofing liquid should be appllied in diluted with 10 % water as primer , after the Priming coat is completly dry becomes slightly darker then apply 1st coat (Base Coat consumption @ .75 kg/Sqm) with undiluted polyurethane based water proofing liquid in criss -cross direction with roller. Spread glass fibre mesh reinforcement of 1mm thickness with overlap of 50mm in both direction when the surface is still tacky . After the drying of 1st coat completly apply the 2nd coat(Top Coat consumption @ .75 kg/Sqm) with undiluted polyurethane based water proofing liquid in a direction parpendicular to previous coat.The min. thickness of dry film of complete application should not be less than the as recommanded by manufacture. The overall dry thickness should not be in any case less than 1.0mm complete all as specified. Product Make : Primer: Sikalastic 590 IN/ Nitoproof 600 PF system/Dr. Fixit; Base Coat,Top Coat & Seal Coat :Sikalastic 590 IN/Fosroc Nitoproof 600 PF system /Dr Fixit; Glass Fibre Reinforcement : Sika Fabric 50/Fosroc/Dr. Fixit or Equivalent. Note :- Cleaning by chiseling all dirt, bushes etc around the opening of Rain water pipes inlets/Khurras and applying one additional coat of polyurethane based liquid applied membrane on it. | 300 | Sqm | - | - |
| 8 | Demolitiion of brick work/stone boulder masonary, built in cement mortar or cement lime mortar including all quions arches,pillars etc but excluding ashlar facings,dressed stone work and precast concrete but exceeding ashlar facingdressed stone work and precast concrete articles complete all as specified. | 20 | Cum | - | - |
| 9 | M&L for walling of random rubble, uncoursed well bonded bedded, and solidily hearted, built in cement mortar 1:6 complete all as specified. | 12 | Cum | - | - |
| 10 | M&L for walling of random rubble, uncoursed well bonded bedded, and solidily hearted, built in cement mortar 1:6.but except stone complete all as specified. | 8 | Cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
tender8658.pdf
Tender Documents • 2.67 MB
BOQ_881004.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].