| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹24.5 L+₹2.0 L (8.84%)Rejected-Finance H NO 82 C BLOCK NO CC SHALIMAR BAGH DELHI 110088 | DELHI | NORTH DELHI | DELHI | 110088 | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹27.0 L+₹4.6 L (20.2%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹28.0 L+₹5.5 L (24.6%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹29.0 L+₹6.5 L (29.1%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
4 Jan 2021, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
INTERNAL PERIODICAL SERVICES AND REPAIR TO LEAKAGE/ SEEPAGE SANITARY FITTINGS TILING AND MISC B/R WORKS AT MD ACCN OF BANA SINGH ENCLAVE AND 180 ORS MAHIPALPUR AND OTM ACCN OF 35 INF BRIGADE 13 KUMAON AND 5/11 GR UNDER AGE B/R II (S) OF GE (SOUTH) D
2020_MES_401284_1
GE/DS-53/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹99,000
Yes
4 Feb 2021
7 Dec 2020
6 Jan 2021
7 Dec 2020
4 Jan 2021
21 Dec 2020
8 Dec 2020 - 19 Dec 2020
Amount
Takaing down cement or cement lime plaster on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed by Engineer in Charge.
M&L for 5 mm thick rendering in CM 1:4 in ceiling on concrete surface finished even & smooth without using extra cement.complete all as specified and directed by Engineer in Charge.
M&L preparaing newly plastered surfaces on walls and applying three coats of white wash complete all as specified and directed by Engineer in Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surfaces finished even and smooth without using extra cement) complete all as specified and directed by Engineer in Charge.
M&L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & over a coat of alkali priming coat complete all as specified and directed by Engineer in Charge.
M&L for Complete removal of existing treatment , from internal surfaces of walls through electrically operated grinder/ Sand paper/ steel patti and thereafter applying wall care putty in holes and cracks as required surface area complete all as specified and directed by Engineer in Charge.
M&L for applying two coats of distemper oil emulsion, on white or tinted over existing prepared base surface complete all as specified and directed by Engineer in Charge.
M&L for applying three coats of white wash on decorated surface of walls complete all as specified and directed by Engineer in Charge.
M&L for Complete removal of existing treatment , from ceiling through electrically operated grinder,/ sand paper/steel patti wahsing complete all as specified and directed by Engineer in Charge.
M&L for preparion of surface as filling of holes/ cracks with filler material like wall care putty/ POP etc and applying three coats of white wash as in ceiling complete all as specified and directed by Engineer in Charge.
M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying one coat of white wash complete all as specified and directed by Engineer in Charge.
M&L for preparation of plastered or unplastered old decorated surfaces of ceiling by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying one coat of white wash as in ceiling complete all as specified and directed by Engineer in Charge.
M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying one coat of oil bound distemper complete all as specified and directed by Engineer in Charge.
M&L for preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing scraping down smoke soot moulds moss and efflorescent salts and treating oily & greasy spots and filling of holes and cracks with suitable material like cement or plaster of Paris etc and there after applying two coat of cement base paint complete all as specified and directed by Engineer in Charge.
M&L Preparing old decorated surfaces of walls & Applying one coat of Interior Plastic emulsion paint complete all as specified and directed by Engineer in Charge.
M&L for preparation of old decorated surface of walls/ceiling and applying one coat of exterior emulsion paint (weatherproof /Apex) including scaffolding arrangements upto three storey, trestles, ladders etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old Steel surfaces of any description not otherwise described over 10 cms width or girth and apply one coats of synthetic enamel paint all as specified complete all as specified and directed by Engineer in Charge.
M&L for preparation of old wooden surfaces of any description not otherwise described over 10 cms width or girth and apply one coats of synthetic enamel paint complete all as specified and directed by Engineer in Charge.
M&L for preparation of surfaces concrete/brick of any description not otherwise described over 10 cms width or girth and apply one coats of synthetic enamel paint complete all as specified and directed by Engineer in Charge.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer in Charge.
M&L 40 mm thick (average thickness) Cement concrete type B-0,1:2:4 (12.50mm graded aggregate) in patches area exe 3.0 sqm as in flooring/ roof pedding , finished even and smooth without using extra cement ,including cleaning the concrete surface by steel wire brushes, up to three stories bldgs, complete all as specified and directed by Engineer in Charge.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing’s or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed by Engineer in Charge.
Taking up or down 15 mm bore steel tubing and connections including cleaning for re-fixing or removal to store , complete all as specified and directed by Engineer in Charge.
Taking up or down 20 mm bore steel tubing and connections including cleaning for re-fixing or removal to store , complete all as specified and directed by Engineer in Charge.
S&F 15 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls/ ceilings or laid in floors or concealed, complete all as specified and directed by Engineer in Charge.
S&F 20 mm bore GI tubes, medium grade galvanised, with all fittings and fixed complete to walls/ ceilings or laid in floors or concealed, complete all as specified and directed by Engineer in Charge.
Dismentling floors, hearth or wall tiling including cement morter bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer in Charge.
M&L for Non skid coloured ceramic tiles 7to 8 mm thick,first quality (Square/rectangular )area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc laid on 15 mm thick cement screed bed in CM (1:6), set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tiles, complete all as specified and directed by Engineer in Charge.
M&L for Coloured Glazed ceramic tiles 300 x 200 x 7 mm thick, as in vertical surface such as skirting/Dado ( in patches) laid on 10 mm thick rendering vertical surface such as in CM (1:4), set and jointed in neat cement slurry at the rate of 3 kg per sqm and pointed in white/coloured cement to match the shade of tiles complete all as specified and directed by Engineer in Charge.
S&F in repair 15 mm angle stop valves (fancy type), cast copper alloy , chromium palted, screwed down high pressure witg crutch and butter fly handles , screwed with iron pipes or for union, flange complete all as specified and directed by Engineer in Charge.
S&F in repair Concealed stop cock (fancy type),15 mm bore, chromium plated ,with long shank and cup ( flange)complete all as specified and directed by Engineer in Charge.
S&F in repair, Bip taps (Long body), cast copper alloy (chromium plated) with crutch or butter fly handle, fancy type screwed down , for iron pipe and fixed , complete all as specified and directed by Engineer in Charge.
S&F in repair PVC valveless, syphonic action type flushing cistern complete with syphon handle lever float valve and PVC bend incl connecting to ITWC/ETWC and fixing on walls with brackets complete all as specified and directed by Engineer in Charge.
S&F in repair vitreous china, semi pedestal pattern (Anglo Indian type) wash down water closet pan, white incl fixing bolt connection to out going pipe and flushing pipe, PVC Seat cover but excluding flushing cistern and flush pipe complete all as specified and directed by Engineer in Charge.
Dismantling water tanks of capacity exceeding 500 litres but not exceeding 1000 litres complete all as specified and directed by Engineer in Charge.
Dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres complete all as specified and directed by Engineer in Charge.
S&F 1000 ltr capacity rotational moulded three layer polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part II complete all as specified and directed by Engineer in Charge.
S&F 500 ltr capacity rotational moulded three layer polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part II complete all as specified and directed by Engineer in Charge.
S&F in repair 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball ,screwed for iron pipe and fixed.complete all as specified and directed by Engineer in Charge.
S&F in repairs 25 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed.complete all as specified and directed by Engineer in Charge.
Dismantling of 75mm/100mm Cast Iron Pipes & Fittings embedded in PCC floor / roof slab sunken portion etc if required complete all as specified and directed by Engineer in Charge.
M&L 100mm bore cast iron soil waste and vent pipes, in any length with or without ears, with cement joint, fixed to wall and making proper functioning of pipe lines complete all as specified and directed by Engineer-in-charge.
M&L 75mm bore cast iron soil waste and vent pipes, in any length with or without ears, with cement joint, fixed to wall and making proper functioning of pipe lines complete all as specified and directed by Engineer-in-charge.
S&F in repair 100mm cast iron sanitary connection socket in fit WC outlet jointing with cement mortar complete all as specified and directed by Engineer in Charge.
S&F in repair 100mm cast iron sanitary connections-short connections pipe of length upto 300mm jointing with cement mortar complete all as specified and directed by Engineer in Charge.
S&F in repair for 75mm Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer in Charge.
S&F in repair for 100mm Cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer in Charge.
S&F in repair for 100mm Cast iron Traps ‘P’ or ‘S’ complete all as specified and directed by Engineer in Charge.
S&F in repair for 75mm Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer in Charge.
S&F in repair for 75mm Cast iron Nahani trap/floor trap with grating including jointing of waste pipe and fixed in cement concrete type B-1, 1:2:4, complete all as specified and directed by Engineer in Charge.
Taking down eaves gutters and rain water pipes (any size or pattern) , including all fittings , heads, shoes, bends,swann necks, etc including cleaning or refixing or removal to store complete all as specified and directed by Engineer in Charge.
S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed by Engineer in Charge.
S&F 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) 100mm dia Bends (any radius ), with access door complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) 75mm dia Bends (any radius ), with access door complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) 100mm dia branch piece, single, (single Y), equal or unequal with access door complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) 75mm dia branch piece, single, (single Y), equal or unequal with access door complete all as specified and directed by Engineer in Charge.
S&F in repairs Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for 100 mm bore pipes complete all as specified and directed by Engineer in Charge.
S&F in repairs Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for75mm bore pipes complete all as specified and directed by Engineer in Charge.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/S GOPAL JEE SINGH
Bluemax Associate
GROUP OF ENGINEERS
P R Constructions
M/S.M.S.Devi.Const.Co
M/S Arvind Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .