| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹53.2 L+₹4.2 L (8.60%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹70.5 L+₹21.6 L (44.1%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | L3 | Rejected-Finance Not Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Since not uploaded docs Application DD as per NIT |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
12 Dec 2023, 6:00 pmClosed
GE NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINESMEG AND CENTRE BANGALORE 560042
REPAIR MAINTENANCE OF DG SETS SOLAR STREET LIGHTS LED STREET LIGHTS POST TOP LANTERNS PATHWAY LIGHTS SOLAR WATER HEATERS AND CLEANING OF UG SUMPS OH RESERVOIR AND REPAIR REPLACEMENT OF EXTERNAL SERVICES ELECTRIFICATION SUPPLY DISTRIBUT
2023_MES_627739_1
8423
Open Tender
Electrical and Maintenance Works
Item Rate
BANGALORE
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH BANGALORE
₹94,000
Yes
8 Feb 2024
9 Nov 2023
19 Dec 2023
9 Nov 2023
12 Dec 2023
29 Nov 2023
9 Nov 2023 - 29 Nov 2023
Amount
Comprehensive maints / periodical maintenance / servicing and repair of standby Eco Friendly / Acoustic type DG set 500 KVA around ADMC area of any Make. 'A' Check Monthly & 'B' check 250Hrs or 3 Months which ever is earlier. Note : 1. As per maintenance schedule prescribed in repair and maintenance manual (Repair & maintenance should be carried out by the qualified and experianced mechanic from the servicing centre who is conversant with the DG set and report should be submitted by the contractor) 2. Rate quoted by the contractor includes the fixing charges for replacement of parts specified in relevant item here in after. 3. The tenderer shall produce qualification and experiance cerificate of the mechanic to the Engineer in charge and approved personal only will be allowed to carried out the work Checking and servicing includes the following :- 'A' & 'B'check (i) Lubricant oil leaking. Condt/---2
Condt/---1 (ii) Operation and repairs to lubricant oil leakage and cooling system leakage, radiator operation with coolant, hoses and connection, belt connection and tension. Fan hub drive pulley and water pump operation and cleaning of radiator cooling system. (iii) Leaking in air intake system, maintenance filter & air cleaner piping connection. (iv) Fuel line and connection, fuel injection pump, cleaning of fuel tank for removing sediments (v) Leakage in exhaust system and exhaust restriction, drain out condensate trap, cleaning & maintenance of exhaust manifold and turbo charger cap screw. (vi) Battery charging system & topping up electrolyte and maintenance of specific gravity (vii) Cleaning of engine tighten of all nut bolt washer and unusual vibration. (viii) Checking to electric connection & smooth operation of generator control panel, greasing to all bearing and movable part, measurement and recording winding insulation resistance cleaning up complete generator/alternator.
Supply only following parts of DG sets as specified under ser item No 1 all as per recommendation of manufacturer and all as directed .Note:-Taking down & fixing charges will be included in SL No.1 OF BOQ. Supply only Fan belt
As per item No 3 above but for Supply only Fuel filter
As per item No 3 above but for Supply only Oil Filter
As per item No 3 above but for Fuel tank cleaning
As per item No 3 above but for Cleaning / Descaling of radiator internally and externally .
As per item No 3 above but for Servicing of self starter
As per item No 1 above but for Capacity of DG set 200 KVA under GE (North) Bangalore
Supply only following parts of DG set 200 KVA specified under ser item No 9 and replacement as per recommendation of manufacturer & all as directed .NOTE:-Taking down & fixing charges will be included in SL item No 9 of BOQ. Fan belt all as per manufactures recommendations
As per item No 10 above but for Supply only Coupling main alternator
As per item No 10 above but for Supply only Fuel filter
As per item No 10 above but for Supply only Oil Filter
As per item No 10 above but for Supply only Air Filter
As per item No 10 above but for Fuel tank cleaning
As per item No 10 above but for Cleaning / Descaling of radiator internally and externally .
As per item No 10 above but for Servicing of self starter
As per item No 10 above but for Supply only coolant filter. Make Fleetguard.
As per item No 10 above but for Supply only Oil sensor.
As per item No 10 above but for Supply only Coolant sensor.
As per item No 10 above but for Supply only fuel water separator. Make Fleetguard.
All as per item No. 1 above but capacity of DG set 160 KVA under GE (North) Bangalore.
Supply only following parts of DG set specified under ser item No 22 all as per recommendation of manufacturer & all as directed. NOTE:- Taking down & fixing charges will be included in SL item No 22 of BOQ. Supply only Fan belt
As per item No 23 above but for Supply only Fuel filter
As per item No 23 above but for Supply only Oil Filter
As per item No 23 above but for Fuel tank cleaning
As per item No 23 above but for Cleaning / Descaling of radiator internally and externally .
As per item No 23 above but for Servicing of self starter
All as per item No. 1 above but capacity of DG set 125 KVA under GE (North) Bangalore
Supply only following parts of DG set specified under ser item No 29 all as per recommendation of manufacturer & all as directed NOTE:- Taking down & fixing charges will be included in SL item No 29 of BOQ. Supply only Fan belt
As per item No 30 above but for Supply only Fuel filter
As per item No 30 above but for Supply only Oil Filter
As per item No 30 above but for Servicing of self starter
As per item No 30 above but for Fuel tank cleaning
All as per item No. 1 above but capacity of DG set/DD Pump Set 100 KVA under GE (North) Bangalore
Supply only following parts of DG set specified under ser item No 35 all as per recommendation of manufacturer & all as directed NOTE:- Taking down & fixing charges will be included in SL item No 35 of BOQ. supply only Fan belt
As per item No 36 above but for supply only Fuel filter
As per item No 36 above but for supply only Oil Filter
As per item No 36 above but for Supply only Carbon brush
As per item No 36 above but for Cleaning / Descaling of radiator internally and externally .
As per item No 36 above but for Servicing of self starter
All as per item No. 1 above but capacity of DG set 62.5 KVA under GE (North) Bangalore
Supply only following parts of DG set specified under ser item No 42 and all as per recommendation of manufacturer & all as directed.NOTE:-Taking down & fixing charges will be included in SL No 42 of BOQ. Supply only Fuel filter
As per item No 43 above but for Supply only Oil Filter
As per item No 43 above but for Fuel tank cleaning
As per item No 43 above but for Cleaning / Descaling of radiator internally and externally .
As per item No 43 above but for Servicing of self starter
As per item No 43 above but for Supply only Fan belt
All as per item No. 1 above but capacity of DG set 50 KVA under GE (North) Bangalore
Supply only following parts of DG set specified under ser item No.49 all as per recommendation of manufacturer as directed NOTE :_Taking down & fixing charges will be included in SL No 49 of BOQ. Supply only Fan belt
As per item No 50 above but for Supply only Fuel filter
As per item No 50 above but for Supply only Oil Filter
As per item No 50 above but for Fuel tank cleaning
As per item No 50 above but for Cleaning / Descaling of radiator internally and externally .
As per item No 50 above but for Servicing of self starter
All as per item No. 1 above but capacity of DG set 30/40 KVA under GE (North) Bangalore
Supply only following parts of DG set specified under ser item No. 56 all as per recommendation of manufacturer as directed NOTE :_Taking down & fixing charges will be included in SL No 56 of BOQ. Supply only Fan belt
As per item No 57 above but for Supply only Hose Fuel suction/return
As per item No 57 above but for Supply only Fuel filter
As per item No 57 above but for Supply only Oil Filter
As per item No 57 above but for Fuel tank cleaning
As per item No 57 above but for Servicing of self starter
As per item No 57 above but for Cleaning / Descaling of radiator internally and externally .
All as per item No. 1 above but capacity of DG set 20/25 KVA under GE (North) Bangalore
Supply only following parts of DG set specified under ser item No. 64 as per recommendation of manufacturer as directed NOTE:-Taking down & fixing charges will be included in SL No 64 of BOQ. Supply only Fan belt
As per item No 57 above but for Supply only Fuel filter
As per item No 57 above but for Supply only Oil Filter
As per item No 57 above but for Fuel tank cleaning
As per item No 57 above but for Cleaning / Descaling of radiator internally and externally .
As per item No 57 above but for Servicing of self starter
All as per item No. 1 above but capacity of DG set 15 KVA under GE (North) Bangalore
Supply only following parts of DG set specified under ser item No.71 as per recommendation of manufacturer as directed NOTE:-Taking down & fixing charges will be included in SL No 71 of BOQ. Supply only Fuel filter
As per item No 72 above but for supply only Oil Filter
As per item No 72 above but for Servicing of self starter
All as per item No. 1 above but capacity of DG set 12.5 KVA under GE (North) Bangalore
Supply only following parts of DG set specified under ser item No. 75 as per recommendation of manufacturer all as directed NOTE:-Taking down & fixing charges will be included in SL No 75 of BOQ. Supply only Fuel filter
As per item No 76 above but for Supply only Oil Filter
As per item No 76 above but for Cleaning / Descaling of radiator internally and externally .
As per item No 76 above but for Servicing of self starter Note :- For item No. 1, 9, 22, 29, 35, 42, 49, 56, 64, 71 & 75 Engine oil and coolant will be measured & paid separately
Dismantling DC dynamo/alternator of battery charging system 12/24V complete servicing including replacement of bushes, bearings, Carbon brushes, diodes any other minor parts required all as directed & fixing on engine testing/commissioning complete for any capacity of DG Set
Material and labour for replacement of unserviceable contactor AC operated 4 pole 415 Volt suitable for the following capacity of DG Set as per the existing in the AMF panel of same make/model. DG Set 500 KVA
As per item No 81 above but for DG Set 200/160 kVA
As per item No 81 above but for DG Set 62.5/100 kVA
As per item No 81 above but for DG Set up to 40 kVA
Supply & fix in replacement of Fuel pipe PVC metal braided of length 0.8 mtr long fitted with benzo adopters to both sides with benzo bolts & washers.
Repair and Maintenance of existing canopy of eco friendly DG Set cleaning of internal & external parts, tightening of loose parts, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations complete all as directed.
Repair /replacement of PCB board of 12.5 to 500 KVA (Make : Kirloskar) etc complete all as specified as directed
Dismantling self starter of engine of DG set capacity 12.5 KVA upto 500 KVA & repairing the starter by replacing carbon brushes, bearings, solenoid coil, brush, brush holders complete rewinding, servicing refixing after repair, testing/commissioning complete all as directed by Engr-in-Charge.
Supply and fix SCR controlled battery charger 12V /24V 15A with TRICKLE and BOOSTING facility, DC voltmeter, Ammeter, toggle switch etc in charge necessary connection from AC supply to Battery Charger and DC wiring to the battery with crocodile clip etc as required complete all as specified and as directed. Make : M/s. Naren or its equivalent approved make.
Supply and fix ON line battery charger 12V with TRICKLE and BOOSTING facility etc in charge necessary connection from AC supply to Battery Charger and DC wiring to the battery with crocodile clip etc as required complete all as specified and as directed.
Supply and fixing in replacement of Door hinges for DG canopy complete all as specified and as directed.
S&F maintenance free Battery 12 volts 80 AH, Make : Exide/Amaron/microtek.
S&F maintenance free Battery 12 volts 180 AH, Make : Exide/Amaron/microtek.
Supply & filling and top up Engine Oil 15w-40. Make : Servo/Volvo/Castrol or equivalent make.
Supply & filling top up Coolant premixture. Make : Servo/Volvo/Castrol or equivalent make.
S&F LVM suitable for DG Set of capcity 20 KVA to 500 KVA.
S&F Solonoid switch for DG Set of capcity 20 KVA to 500 KVA.
M&L to repair AMF panel for DG Set of capcity 20 KVA to 500 KVA.
M&L for Add on block (Axilluary contract) for contactor for DG Set of capacity 20 KVA to 500 KVA.
M&L relay 170 ohm, 12 AA for control panel for DG Set of capcity 20 KVA to 500 KVA.
M&L KWh meter for DG set panel upto 500 KVA. Make : EIC or equivalent approved make.
M&L VAFhr meter for DG set panel upto 500 KVA. Make : EIC or equivalent approved make.
M&L Start/Stop push button for DG set panel upto500 KVA.
S&F Oil temperture gauge for DG set upto500 KVA.
S&F Oil pressure gauge for DG set upto 500 KVA.
S&F Hours run meter dial type for DG set upto 500 KVA alongwith connecting cable.
S&F RPM meter (Gernator safety unit) having all parameters Oil temperature/pressure gauge for DG set upto500 KVA. Model No : GSU-904 of Make : SUN Industrial Automation & Solutions or equivalent make.
S&F in replacement of AVR of any type /size for three phase DG Sets upto 500 KVA as per existing make all as specified and directed. Make : Kirloskar or equivalent make.
S&F in replacement of inner Air filter element of any type /size for DG Sets upto 500 KVA as per existing make, type and size all as specified and directed. Make : Fleetguard / Cummins or equivalent make.
S&F in replacement of battery lead of colour Red and Black for +ve and -ve suitable for Battery 12 Volt 180 AH alongwith copper lugs and brass terminal of suitable size.
Dismantling the existing alternator 35/100KVA from the exisitng base plate after disconnecting the electric connections and disassemble the alternator complete, removing the burnt out winding from the starter in a suitable way, cleaning, decarbonishing the starter, rotor and coating with epoxy insulation varnish after rewinding the startor with suitablecopper wire and insualtion, varnish it with replacement of bearing as per existing suitable size and make after reassembling coupled with engine connecting electric connections, commissioning and testing complete. Note : Quoted rate is inclusive for transportation for carrying alternator from site to nearest workshop and back
Taking down old unserviceable HPSV/ HPMV street light fittings & Supply and fixing new 70 W LED street light fitting with pressure die cast housing, toughened glass and indivudial LEDs with secondary optics and IP 66 protection. Make:- Bajaj, Cat No.:- Bajaj Cat No.:- ENXT P 84L WH CR PC SD or techno commercially equivalent in Havells / philips / CG
Dismantling and taking down old unserviceable CFL type street light fittings from Pole, removing the unserviceable CFL and replacement new LED bulb 40 watt and refixing the existing/new location all as directed at site.
Dismanling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 25 W to 60 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site.
Dismanling and taking out the LED street light fittings any make from Pole and removing the burned out /unserviceable LED driver 90 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site.
Dismanling and taking out the flood light from high mast pole and removing the burned out/unserviceable LED driver 200 W and replacement of new drive to make the fitting serviceable and refixing the existing/new location all as directed at site.
Supply and fixing,replacement of moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 06 Amp MCB SP and two number of cable entry gland of standard size with suitable MSclamp to fix with pole complete all as directed
Supply & Fix in replacement of GI pipe bracket on pole/ wall etc made of 40mm bore light grade GI pipe1.5 mtr long suitably bent to shape and fixed on wall/ pole for fixing street light fitting with 2 Nos suitable MS clamps of size 25 x 3 mm size incluiding bolts, nuts, washers all as specified and as directed.
M & L for PCC 1:3:6 type C1 with 20mm graded stone aggregate for coping of pole,filling and mass concrete of pole, make good to road surface, hard standing etc incl necessary form work all as specified and as directed
S & F in replacement of 03 core sheathed of 2.5 sqmm PVC insulated cable with mulitstanded copper PVC insulated cable with multistanded copper conductor 1100 volts grade cofirming to IS 694 including drawn throgh the steel tubular pole and connection to light fitting and MCBs all as specified and as directed.
S&F in replacement of 45 Watt post top LED light fitting, die cast aluminum graphite grey powder coated spigot, Acrylic clear diffuser, spun aluminum power coated canopy, LED connected in series and paralled combination either better heat dissipation arrangement, LED colour 3000 K + 300K, open and short circuit protection, voltage surge protection 5KV, suitable for 60mm OD pipe entry with fixing bolts, IP-65. Make :- Bajaj Cat No. BGCT W4 LED WH or Equivalent in Havells/Phillips/Crompton.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 25x4mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed
Supply & fix in replacement of LED bollard 9 watt with opal acrylic diffuser and IP 65 protection Make :- Bajaj Cat No. BGBOL605 9W LED or Equivalent in Havells / Phillips / Crompton.
Boring of holes under road,pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 63 mm dia bore suitable for 0.4 mpa working pressure. Note : Quoted rate is inclusive of obtaining necessary approved from authorities concerned.
Maintenance / servicing, cleaning, descaling of solar water heating system complete of capacity 100/200 Ltr per day with 02 Nos of collector of any size 01 No of stainless steel tank and 01 No of plastic make up tank 500 Ltr by replacement of washers, gasket, adaptor and worn out nut bolt, GI fitting for water pipe line 20/25 mm dia for inlet and outlet of stainless steel tank / collector /water make up tank and making fully leak proof by brazing / welding of the inner container for arresting leakages complete and testing for satisfactory performance all as specified and directed.
All as per Sl Item No. 126 above but of capacity 201/300 Ltr per day.
Replacement of broken glass of solar flat plate collector of size 206 cm x 105 cm x 4 mm thick (L x B x W) (or as per existing size) by new one including rubber packing complete all as specified and as directed.
S&F ETC Tube 47mm dia/ 54mm dia, glass tube with copper coating fixed in repairs complete all as specified and directed.
S&F in replacement of Stainless steel water heater tank of capacity 100/200 LPD complete as per existing SS tank fixed all as specified and directed.
Supply and fix in replacement of Timeline distribution board 32A 3 pole /230V analog time switch including complete accessories relay contactor etc, timer with battery back up all as specified and as directed. Make:- Indoasian Cat No. TL040AB0 or its equivalent in L&T / SIEMENS
Replacement black hose pipe suitable for 20/25mm dia hot/cold water pipe for solar hot water system of 1m length all as specified by Engr -in Charge
S&F Electric heating element 3KW, ISI Marked threaded/cup type to SS tank of solar water heating system 100/150/200 ltrs capacity with necessary fixtures including taking out unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F Thermostat of any size and type as per existing type, ISI Marked for solar water heating system 100/150/200 ltrs capacity including taking out unserviceable one all as specified and directed by Engr-in-Charge.
Supply installation, testing and commissioning of LED Solar Street light All IN ONE TYPE with inbuilt battery, SPV Module of capacity 12 Watt of light source and 12 watt SPV panel, IP 65 protection, Lumionous efficacy 120 Lm /watt, Colour temperature 6000 K, battery 12.8 V, 12 AH including charging system with overload protection, light sensor devices , GI /MS pole of suitable dia of length 5 to 6 mtr duly painted etc all as specified and directed. Note : Excavation, PCC required for foundation as per the manufacturer reccomendation shall be included in the quoted rate. Make: Bajaj & Model no:- Model No: 152404 SOLAR BSZSL 12 W LED or its equivalent from approved makes
Supply installation, testing and commissioning of LED Solar Street light All IN ONE TYPE with inbuilt battery, SPV Module of capacity 20 Watt of light source and 38 watt SPV panel, IP 65 protection, Lumionous efficacy 120 Lm /watt, Colour temperature 6000 K, battery 12.8 V, 18AH including charging system with overload protecion, light sensor devices , GI /MS pole of suitable dia of length 5 to 6 mtr duly painted etc all as specified and directed. Note : Excavation , PCC required for foundation as per the manufacturer reccomendation shall be included in the quoted rate. Make: Bajaj & Model no:- Model No: 152407 SOLAR BSZSL 20 W LED or its equivalent from approved makes.
M & L for GI tubing light grade 40 mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate is included in the item.
M & L for GI tubing light grade 80mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate is included in the item.
M & L for GI tubing light grade 50mm with all accessories for cable protection fixed on poles/bldgs/road and laid in trenches incl necessary MS clamps, bolts and nuts etc all as specified and as directed. Note road cutting rate is included in the item.
M&L for painting of steel tubular/PCC poles of any height and type ,incl security light mounting brackets with one coat of aluminium paint/two coat of cement base paint incluing painting black and yellow strip or as ordered by engineer-in-charge on poles up to 1.5 mtr high above coping level and numbering of pole complete all specified and as directed.
Supply and fixing 60 W LED street light fitting with pressure die cast housing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection and impact resistance of IK 08. 4kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. Make:- Bajaj, Cat No.:- ENXT P 72 L WH CR PC SD or equivalent makes & Model Havells / Panasonic/ Phillips / CG”
Supply and fixing 90 W LED street light fitting with pressure die cast housing and toughened glass and individual LEDs with secondary lens optics with IP 66 ingress protection and impact resistance of IK 07. 5kV inbuilt and 10 kV external surge protection with top opening driver cover for easy maintenance .including taking down old unserviceable street light fittings from pole. Make:- Bajaj, Cat No.:- BRTFG 90W LED CR or equivalent makes & Model Havells / Panasonic/ Phillips / CG”
Supply & Fix 200W LED flood light luminaries with ultra sleek, light weight and with secondary optics, made of pressure die cast housings with IP 66 ingress protection and impact resistance of IK 07, 4kV inbuilt and 10 kV external surge protection, suitable for highmast lighting with complete accessories including taking down old unserviceable flood lights from high mast pole all as specified and as directed. Make:- BAJAJ, Code No. : BJFL 200W LED I or equivalent makes & Model Havells / Panasonic/ Phillips/CG
M&L for painting of outdoor type Feeder pillar panel upto the size of 1100 x 450 x 1200 mm (approx), incl replacement of door hinges if unserviceable with new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed.
M&L for painting of outdoor type LT panel upto the size of 2500 x 600 x 3000 mm (approx), incl replacement of door hinges with new one and apply one coat of smoke grey colour paint and base angle with black paint complete or as directed by Engineer-in-charge complete all specified and as directed.
S&F in repairs 200 LPD Stainless steel Water heater tank of thickness as per existing SS Tank complete all as specified and directed
Supply, installation, tesing and commissioning in replacement of Lithium based Solar Security light System with bult in Battery and PV Panel and LED lamp in FRP body and including taking down of old unserviceable light fitting of any size/capacity complete system comprises followings:- (a) PV Panel 30 W Monocrystalline. (b) Lithium cell for back up 15.4 AH with inbuilt BMS. (c) High brightness W-LED lamps 15W, CRI>700, CCT 6500K. (d) Microcontroller based charge controller cum diriver with automaic dimming dunction, Operation. (e) Working temperature; (-) 10 degree C to (+) 55 degree C. (f) System shall be supplied with adjustable MS clamp and 40 mm dia arm suitable for pole/wall mounting complete with satisfaction of Engineer-in-Charge. Make Bajaj/Philips/Havells/Syska.
M & L for Emptying complete water, removing sludge, silt, cleaning internally all the walls and bottom with wire mesh/brush/brooms etc by using washing soda and bleaching powder completely, finally cleaning with plain water for making the sump suitable to store potable drinking water incl one coat white washing inside and marking out side sump in visible place the capacity of sump, date of cleaning, due date for cleaning with white enamel paint, over black enamel paint complete all as specified and as directed by Engineer-in-Charge for the following sumps:- Capacity of 5000 gallons at NTG/NLC
As per item No 148 above but for Capacity of 50000 gallons at Naval Detachment
Removing old unserviceable float valve from service tank supply and fix float valve 20mm bore with PVC body aluminium float rod, nylon float high presure type.
M & L excavation in trenches in hard/dense soil not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of cables/errection of pole etc complete all as specified and as directed.
M & L excavation in trenches in hard/dense soil exc 1.5 mtr deep and not exc 3 mtr in deep for pole foundation etc complete all as specified and as directed.
M & L for returning, filling in trenches incl spreading leveling watering and well ramming in layers with hard/dense soil not exc 25 cm thick in each layer complete as specified and as directed
M & L for removing excavated soil to a distance not exc 1.5 mtr above the starting point complete all as specified and as directed
M & L for sand cushioning with a layer of M-sand 23 cm thick under and above the cable complete all as specified and as directed
S & L sub class burnt bricks for cable protection complete as specified as directed
Taking down old unserviceable /burnt XLPE cable from trench/wall/pole of following size :- 2 C x 10 Sqmm
As per item No 157 above but for 4 C x 10 Sqmm
As per item No 157 above but for 4 C x 16 Sqmm
As per item No 157 above but for 3.5 C x 25 Sqmm
As per item No 157 above but for 3.5 C x 35 Sqmm
As per item No 157 above but for 3.5 C x 50 Sqmm
As per item No 157 above but for 3.5 C x 70 Sqmm
As per item No 157 above but for 3.5 C x 95 Sqmm
As per item No 157 above but for 3.5 C x 120 Sqmm
Supply and laying cable XLPE insulated screened PVC bedded galvanised steel strip or wire armored, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor connected with suitable lugs for following size :- 2 C x 10 Sqmm
As per item No 166 above but for 4 C x 10 Sqmm
As per item No 166 above but for 4 C x 16 Sqmm
As per item No 166 above but for 3.5 C x 25 Sqmm
As per item No 166 above but for 3.5 C x 35 Sqmm
As per item No 166 above but for 3.5 C x 50 Sqmm
As per item No 166 above but for 3.5 C x 70 Sqmm
As per item No 166 above but for 3.5 C x 95 Sqmm
As per item No 166 above but for 3.5 C x 120 Sqmm Note for item 166 to 174 : Earthwork, sand cushioning & cable covers will be measured and paid separately.
M&L for replacement of MS work of any type incl cross arms, supports, bracing MS clamps etc made out of MS channel/angle iron/flat iron/ round section of any size and bolt nuts and washer incl painting with two costs of aluminium paint over a coat of red oxide all as specified and as directed
M&L in replacement of pin type porcelain, vitreous white or brown insulator incl one galvanized mild steel spindle two galvanized iron washer and galvanized iron nut 100 mm height and 65mm dia for 1100 volts grade complete all as specified and as directed
M & L in replacement of shackle type porcelain, vitreous white or brown insulator incl one galvanized mild steel spindle two galvanized iron washer and galvanized iron nut 75 mm height and 90mm dia for 1100 volts grade complete all as specified and as directed
M & L for tightening of ACSR (Aluminium conductor steel reinforced) conductor of any size between two poles 06 runs of conductor incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed
S & F in replacemet of unserviceable existing /suitable size MCCBs 4 pole 415 Volts 50HZ incl complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape as under. MCCB 100 Amps ,16 KA with adjustable Thermal setting
As per item No 179 above but for MCCB 200 Amps 36 KA with adjustable Thermal setting .
As per item No 179 above but for MCCB 250 Amps 36 KA with adjustable Thermal setting .
As per item No 179 above but for MCCB 315 Amps 36 KA with adjustable Thermal setting .
As per item No 179 above but for MCCB 63 Amps, 25 KA with adjustable Thermal setting
M & L for replacement of LT 2 line separator 230 volts 50 Hz all as specified as directed
M & L for replacement of LT 4 line separator 415 volts 50 Hz all as specified as directed
M&L for taking down old cable joint and Supply and fix cable jointing kit for 1.1KV grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core/4core XLPE armoured aluminium conductor cable for following sizes:- 3.5 C x 25 to 35 Sqmm
As per item No 186 above but for 3.5 C x 50 to 120 Sqmm
Dismantling of ACSR (Aluminium conductor steel reinforced) conductors
M&L of ACSR (Aluminium conductor steel reinforced) conductor of any size fixed on poles incl binding wire of appropriate size complete incl clearing of path and branch cutting etc all as specified and as directed
Refixing of ACSR conductor connected with new existing wire tightening to insulator incl line clearance by pruning of tree branch approx 1 m apart from conductor tightening side.
Stay assembly complete with all accessories as shown in elect plate No 1 of SSR Part-I consisting of stay rod 20mm dia 1.8 mtr long,size of stay plate 230 x 230 x 6 mm with nuts,bolts,insulator stay clamps etc. complete all as shown on drawing and as directed Note:- Excavation and stay wire shall be measured and paid separately
M&L for galvanized stay wire stranded 7/4 mm complete all as specified and as directed
Dismantling the damaged unservicable pole of any type.
Supply and errect steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts & screws as specified type 410SP-31, 9 mtr long. Note : Earthwork, pCC will be measured and paid separtely.
M&L for PCC 1:4:8 type D2 with 40mm graded stone aggregate in foundation of poles all as specified and as directed
M&L for outdoor type, double door sheet metal enclosure/Junction box of size 80x80x30 cm with aluminium bus bar 250 Amps for 3 phase & neutral including MCCB 4 pole 415 volts 160 Amps 36 KA .including removing old unserviceable junction box complete all as specified and as directed
M&L for cable finding cable fault in LT cables any sizes complete all as specified and as directed
S&F in replacement of 2 runs of PVC insulated 2.5 sqmm single core multistranded copper conductor cable and one run of 2.5 sqmm copper wire as earth continuity conductor drawn through and incl rigid non metalic conduit 20 mm external dia fixed on poles & connecting up all as specified and as directed. Note: Two runs of cable and one run of earth wire and one run of conduit shall be measured as one length.
Supply & fix in replacement of on load Change over switch 4 pole in sheet metal enclosure compact design rating 63 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks Make :- C&S Cat No- E-CSCS63NM4CO or equivalent Havells / L&T / Standard / INDOASIAN
Supply & fix in replacement of on load Change over switch 4 pole in sheet metal enclosure compact design rating 100 Amps suitable for isolation and prevent leakage current/ flush over between phases, handle lock feature in off position with three padlocks Make :- C&S Cat No- E-CSCS100NM4CO or equivalent Havells / L&T / Standard / INDOASIAN
M&L in replacement of outdoor type Lt panel front opening door upto the size of 2500 x 3000 mm (approx), with 3.15mm MS Sheet incl replacement of door hinges with new one and duly with powder coated, painted one coat of red oxide primer and two coats of synthetic enamel paint of smoke grey colour as directed by Engineer-in-charge complete all specified and as directed.
M&L LT feeder pillar box/panel board/out door type, made out of MS sheet 3.15 mm thick duly powder coated, dust and vermin proof and angle iron frame of size 40x40x6 mm mounted on angle iron bracket (40x40x6mm) ie, 15cm below groung level and 15cm above ground level with suitable foundation/ platform for mounting the panel
GS TRADERS
Aavani BUILDERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .