| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC Lowest bidder. | |
| 2 | L2₹23.4 L+₹1.4 L (6.59%)Rejected-AOC H NO 02 SAGAR ROAD OPPO MKD GIRLS SCHOOL TILAK NAGAR BIKANER 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-AOC Not lowest bidder. | |
| 3 | L3₹24.5 L+₹2.5 L (11.4%)Rejected-AOC | L3 | Rejected-AOC Not lowest bidder. | |
| 4 | L4₹24.8 L+₹2.8 L (12.9%)Rejected-AOC | L4 | Rejected-AOC Not lowest bidder. | |
| 5 | L5₹25.9 L+₹4.0 L (18.0%)Rejected-AOC | L5 | Rejected-AOC Not lowest bidder. |
Tender Value
₹28.8 L
EMD Value
₹57,600
Closing Date
10 Aug 2021, 6:00 pmClosed
CWE Bikaner
HQ CWE Bikaner, Military Station Bikaner
Provn of open storage shed for repair of furniture at BSO (N) and boundary wall with board near site GE (N) at Bikaner Mil Stn
2021_MES_460030_1
CWE BKN TOKEN NO 29 OF 2021-22
Open Tender
Civil Works - Others
Item Rate
150 days
Bikaner
Contractor shall be enlisted with MES in Class D and above and category a(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in WLR. Contractor not enlisted with MES should meet the enlistment criteria of D
7 documents required · 7 mandatory
₹500
GE (N) Bikaner
₹57,600
Yes
25 Aug 2021
15 Jul 2021
12 Aug 2021
15 Jul 2021
10 Aug 2021
29 Jul 2021
15 Jul 2021 - 24 Jul 2021
Amount
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing excavated soil/material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface in soft/ loose soil complete all as specified & as directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers not exc 15 cm thick spread, leveled and rammed including watering complete all as specified.
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:2:4 type B2 using 40 mm graded crushed stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
Supply only integral liquid water proofing compound (ISI marked).
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with old size burnt clay sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified and as
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc. conforming to Gde E-250 (Fe 410-W) quality `A’ complete all as specified and as directed.
S&F mild steel framed work using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc. complete all as specified & as directed.
S&F Pre-painted galvalume aluminium zinc coating corrugated steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
S&F Pre-painted galvalume aluminum zinc coating Plain steel sheet 0.50mm thick with coating AZ-150 gsm of any colour having tensile strength of 550 Mpa as in roof covering/ridge/fascia/cladding to wall, fixed with self tapping screws complete all as specified & as directed. Note : Colour of sheet shall be as approved by the GE.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 5 cm long and dia of neck 11 to 15 mm complete all as specified & as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exc 30 cm long and dia of neck 16 to 20 mm complete all as specified & as directed.
M&L for 100mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in floor, top surface finished even & smooth without using extra cement (PCC shall be laid in alternate bays in panels of size not exc 2m x 2m or as directed) including necessary formwork complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for factory made 80mm thick machine pressed precast cement concrete coloured designer polished (reflecting type) interlocking paver blocks of Grade M-40 conforming to IS 15658-2006 of shape and size as directed with grey cement and no pigment with coloured top casted in an automatic plant working on vibration and simultaneous hydraulic compression from top, laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & as directed. Note : Shape & colour of paver blocks shall be as approved by the GE.
M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished even and smooth without using extra cement complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:30 in alternative bays not exceeding 4 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with integral liquid water proofing compound as per manufacturer’s instructions, finished even & smooth without using extra cement, complete all as specified and directed. Note : Supply only integral liquid water proofing compound shall be measured and paid for separately.
M&L for preparation of newly plastered / unplastered surfaces of walls & applying three coats of white wash complete all as specified.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
Supply, fixing and installation of Glow Shine Board of size 8 x 2.50 feet (3mm milky white acrylic sheet letter 2.25 inch rising) with modular warm lights. In Glow sign board “HAPPY TO HELP : GE (N) BIKANER” words shall be written with acrylic sheet letters with & including complete lighting work etc as per best trade practice complete all as specified and as directed. Note : The lettering font & style, lightning work, etc shall be as directed by GE.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
All as per serial item No. 28.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches.
All as per serial item No. 28.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No. 28.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 15 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 3 pin (2 in 1, with 2 pin outlet also), 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/casing caping fittings, ISI marked, complete all as specified and as directed.
S&F 9 Watt LED Bulb (Non-dimmable) of Standard / Universal size, Base - B22, Power Factor > 0.90, Lamp Efficiency > 80%,, Color Temperature - 3000 K, Lumen output - 900 lm, Colour Rendering Index (CRI) > 70, Warm white (WW) / Cool Day Light (CDL), 230 V, 50 Hz AC, ISI marked, complete all as specified and as directed.
S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 150 Watt, including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed.
S&F energy efficient decorative ultra slim LED light fitting, 1x20 Watt, 230 Volts, Day Cool light, batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed. Make : Havells Cat Part No. LUMILINEBS20WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Supply, installation, commissioning & testing Light Emitting Diode (LED) based street/security light fitting, 35 Watt with & including LED lamp, housing made up of LM6 pressure die cast aluminium alloy with effective thermal management, sturdiness, monolithic construction, totally enclosed, dust and water proof, minimum system efficiency of more than 100 lumens per watt and a minimum system lumen output of not less than 3500 lumens, correlated colour temperature shall be minimum 5700 degree Kelvin, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, ingress protection of IP-65 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, frequency 50-60Hz, potted type for humming free operation, driver shall withstand upto 400 V for 08 hours, surge protection not less than 10 KV, Power factor > 0.95, Total Harmonic Distortion (THD) shall be less than 15%, double phase protection, no load, open circuit and short circuit protection, suitable for ambient temperature from (-)10°C to 50°C and humidity level 10% to 90% RH, cool white colour and lamp starting time shall not be more than 10 second, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting up to street light feeder/junction box with & including 2.5 Sqmm 3 core PVC insulated, weather proof, multistranded copper conductor cable of 1100 Volt grade (ISI marked), complete all as specified and as directed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply and fixing mounting bracket (suitable for fixing/holding street/security light fittings) made of 40mm bore GI pipe ‘light grade’ not less than 1.50m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, complete all as specified and as directed.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, 10 kA, ‘C’ Curve, with over load and short circuit protection, complete all as specified and as directed.
Supply, assembling, hanging, fixing & testing Ceiling Fan of size 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, 5 star rated, with brushless direct current (BLDC) motor, single phase, AC supply, 230 Volt, with & including down rod, canopies, three number blades, capacitor 2.5 mfd, hook, rubber reel, safety pins, nuts, bolts, washers, cable connector and making connection with PVC insulated & sheathed 1 Sqmm three core flexible copper multistranded conductor cable (ISI marked) from ceiling rose to connector of ceiling fan including marking of SM / MES number with thick synthetic enamel paint of approved tint complete all as specified and as directed. Note :- The font, style & place of writing SM/ MES number with synthetic enamel paint on ceiling fan shall be as directed by the Engineer-in-Charge and cost thereof shall deemed to be included in quoted rates.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc complete all as specified. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified. Notes :- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed. Notes :- (i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.
M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
SHREE GURU NANAK CONSTRUCTION COMPANY
M/S ASHRAFI CONSTRUCTION CO
NAIRA CONSTRUCTIONS AND MANAGEMENT SERVICES
VASU ENGINEERING SERVICES
M/S BIKANER CHEMICAL LABORATORIES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .