Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest quoted tenderer | |
| 2 | L2₹18.3 L+₹3.1 L (20.7%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹18.5 L+₹3.3 L (21.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹19.1 L+₹3.9 L (26.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹46,240
Closing Date
4 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Allahabad
HQ CWE New Cantt Allahabad
REPAIR AND MAINT OF CERTAIN AC PLANTS, PACKAGE AND WALK IN COOLER ETC AT NEW CANTT ALLAHABAD UNDER GE (WEST) ALLAHABAD.
2021_MES_430118_1
81592/W/E8
Open Tender
Civil Works
Item Rate
180 days
Allahabad
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (West) Allahabad
₹46,240
Yes
16 Jun 2021
12 Mar 2021
6 May 2021
13 Mar 2021
4 May 2021
20 Apr 2021
60 days
Amount
M&L for checking the leakage in both low and high side of the system by feeding dry nitrogen upto 300 PSI to maintain adequate pressure in the system, plugging the leaks including S&F in replacement of Teflon sealing of all refrigerant line valves like liquid lines valves/ suction/ discharge valves of compressors, gland packages of all angle valves flaring of all connections framing welding etc complete for AC plant of capacity 3x37.5TR-Plant for OT millitary Hospital, complete all as specified and directed by Engr-in-Charge.
M&L for opening the upper sheet and side sheet of AHU for access to cooling coil including M&L for washing/cleaning of cooling coil externally with mild acid (or caustic soda hot water solution) followed by water jet including cleaning/washing of air filters and re-fixing and changing of V Belt both set with necessary fitting and T&P for mounting for AC plant of capacity 3x37.5TR- Plant for OT Millitary Hospital, complete all as specified and directed by Engr-in-Charge.
All as per Srl item No. 3.00 here-in-before but for AC plant of capacity 2x75TR-Plant for SCE, complete all as specified and directed by Engr-in-Charge.
M&L for dismantling of electric driven horizontal induction motor of capacity 35/40 HP of any type and make, by engaging sufficient man power and suitable T&P to ensure safety of motor including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed. Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect.
All as per Srl item no 5.00 here-in-above but for 25/30 HP capacity.
All as per Srl item no 5.00 here-in-above but for 20 HP capacity.
All as per Srl item no 5.00 here-in-above but for 10/12.5 HP capacity.
All as per Srl item no 5.00 here-in-above but for 5/7.5 HP capacity.
All as per Srl item no 5.00 here-in-above but for 3.0 HP capacity.
M&L for complete overhauling of condenser / chiller centrifugal pumpset of 20 HP by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting suction & discharge water lines and removing of electric connection, dismantling the U/S pumpset from MS foundation, detaching the pump, opening the pump, remelting the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump body complete incl carrying out complete repair / replacement of damaged parts i.e. bearings, bush, gland plate, gland packing, coupling assembly etc and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc; checking the alignment; reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as specified and directed.
All as per Srl item no 11.00 here-in-above but for 10 /12 HP capacity.
All as per Srl item no 11.00 here-in-above but for 5 /7.5 HP capacity.
Overhauling, testing, and commissioning of open type reciprocating compressor 75 TR Capacity including dismantling and disconnecting suction and discharge refrigerant lines, other controls and accessories, loading, transporting to contractors workshop and back to plant room after necessary repairing and then reinstallation in its original position . Note:- (i) Replacement/ renewal of minor items not covered in the succeeding items of Sch 'A' but essentially required for completing the Job i.e. gasket kits, cut washers, valve springs, castle nuts, etc shall be provided by the contractor and no extra payment shall be admissible on this account. (ii) Major items requiring renewal shall be measured and paid separately as supply only as given below.
Supply only suction/discharge reeds for compressor of Make:-Blue Star, model No LCWR-1 - 075, 75 TR capacity complete all as specified and directed.
Supply only new piston with pin & ring set for compressor of Make:-Blue Star, model No LCWR-1 - 075, 75 TR capacity complete all as specified and directed.
Supply only oil pump for compressor of. Make:-Blue Star, model No LCWR-1 - 075, 75 TR capacity complete all as specified and directed.
Supply only connecting rod for compressor of 75 TR capacity complete all as specified and directed.
Supply only new cylinder sleeves for compressor 75 TR capacity complete all as specified and directed.
Supply only new helical spring discharge / suction for compressor of 75 TR capacity complete all as specified and directed.
Supply only main bearing front and rear for compressor of 75 TR capacity complete all as specified and directed.
Supply only water temperature senser for compressor of 75 TR capacity complete all as specified and directed. Make:-Blue Star
M&L in replacement Y-type strainer flanged type as per existing 50/80mm dia, complete all as specified and directed by Engineer-in-Charge. Make : Zoloto/Leader /Zenith / Crescent
M&L for dismantling existing water softener and replacement with raw water in to online electrostatic non chemical water treatment system electrically operated control panel to be fixed on sub header/tapping suitable for , the outer casing shall be of 304 grade stainless steel with both ends flanged and capable of preventing scale formation of AC Plants flanged ends including necessary mechanical jointing operation like welding work, nut, bolts and rubber packing with starter panel electronically operated of existing length. Complete all as specified and directed by Engr-in-Charge. Make: scale off model no 3021 mfg by Weldon Engineers
M&L for cleaning of all condensor tubes of central AC plant by disconnecting the condensors -02 Nos from the system, cleaning by descaling pump using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower by using descaling solution, cleaning condensor tubes by nylon brushes & mild steel rods of suitable size, renewal of suction water filter for 2x75 TR capacity plant at SCE complete all as specified and directed. Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.
M&L for cleaning of all condensor tubes of central AC plant by disconnecting the condensors - 03 Nos from the system, cleaning by descaling pump using descaling solution of Make:-MAIC / HIBIRD or Hydrochloric acid 20%, cleaning the system through cooling tower by using descaling solution, cleaning condensor tubes by nylon brushes & mild steel rods of suitable size, renewal of suction water filter for 3x37.5 TR capacity plant at MH complete all as specified and directed. Note:- T&P such as pumps, tube etc & descaling solution etc shall be arranged by the contractor at his own cost.
Dismantling of burnt fan motor of walk cooler out door unit double shaft and supply & fixing new fan motor (Suitable for Carrier/Voltas/Blue star/LG/Samsung Make AC) as per sample complete all as specified and directed.
Servicing of IDU (Indoor unit) of ceiling mounted casset type split Air conditioner of 3 TR/4 TR capacity comprising of Blower, blower motor ,water lifting motor, oiling & greasing of moving parts complete all as specified and directed.
Supply and filling in compressor oil for topping up make- servo friz 68/Freezol 68 or as recommonded by the dealer suitable for existing compressor complete all as specified and directed
S&F in repairs brass suction valve size 3/8" complete all as specified and directed
S&F in repairs Discharge valve size 1/2" complete all as specified and directed .
S&F in repairs ML-1 contractor 240 volt, 25 Amp for split type AC complete all as specified and directed
S&F in repairs copper capillary of size 0.55 mm complete all as specified and directed
M&L for Nitrogen pressure testing Flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22 into walking cooler unit all as specified and directed. (The refrigerant gas R-22 will be provided by Contractor)
Servicing and overhauling of walk in cooler of any make Blue star Model - PC 1950 with strainer steel product and with two condensing unit installed at any location in cantonment including cleaning and painting internally and externally with two coats of synthetic enamel paint; reparing/ renewal/ replacement of defective parts and component all as specified and directed. Parts renewed shall be measured and paid separately under appropriate items complete all as specified and directed.
S&F in replacement of expanssion device of walk in cooler complete all as specified and directed.
S&F in replacement of PLC unit of walk in cooler 2 ton capacity complete all as specified and directed. Make: Siemens/ Schnieder
S&F in replacement of PCB circuit of walk in cooler complete all as specified and directed.
Removing burnt/ defective sealed compressor unit of any make from any type of walk in cooler 1.5/2 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc all as directed
M& L for repair to PCB circuit in walk in cooler 1.5/2 ton capacity complete all as specified & directed.
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 1 complete all as specified and directed. Make:- INDFOSS / RANUTROL
Taking out the existing unserviceable low pressure cut - out switch and supply & fixing new low pressure cut-out switch type. MP - 5 complete all as specified and directed. Make:- INDFOSS / RANUTROL
Taking out the existing defective pilot control solenoid valve and supply & fixing new pilot control solenoid valve all as specified and directed. Make: SPORLAIN or as approved by G.E.
Taking out the existing defective loader / unloader solenoid valve ( Capacity Control solenoid valve) and supply & fixing new loader / unloader solenoid valve all as specified and directed (Make: Nikko / Rotex or equivalent as approved by GE)
S&F in repairs single phase preventor to prevent against single phasing, reverse phasing with wiring & testing complete all as specified and directed Make:- Minilec / Electromed / L&T
Supply only refrigerant gas Non CFC compatible to R-22 in returnable sealed cylinder all as specified and directed. Make:- Floran / Mafron
Supply only refrigerant gas Non CFC compatible to R-407 in returnable sealed cylinder all as specified and directed. Make:- Floran / Mafron/R value.
Taking out the existing silica gel flange type filter drier 1/2" x 1/2" dia flare and supply & fixing new filter drier of the same type & size (Make:- Universal / Unistar) including repairs to flare etc at all as specified and directed by EIC
Supply and replacement of return air grill aluminium with powder coated white collers of size 300 mm x 900 mm complete all as specified and directed.
Supply and replacement of air grill MS air control damper of size 300 mm x 900 mm complete all as specified and directed.
M&L for servicing of air curtain by removing the existing choked fins/filters complete all as specified and directed by Engr-in-Charge.
Removing burnt/defective sealed compressor unit of any make from any type of air conditioner split/cassele type 3 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc complete all as specified and directed
S&F in replacement of blower Motor 0.2/0.25 HP for walking cooler/Air curtain complete and as directed and specified. Make - GE/Crompton/Polar.
S&F in replacement of blower Motor 0.5 HP for walking cooler complete and as directed and specified Make - GE/Crompton/Polar.
S&F in replacement of PCB circuit as per existing model of walking cooler all as specified & directed. Make – Blue Star/Voltas/Carrier.
M&L for removing the existing choked fins of 2x75/3x37.5 TR cap cooling tower and supply and fixing new fins to cooling tower for AC Plant complete all as specified and directed by Engr-in-Charge.
S&F in repairs capacitors 6 Mfd capacities 2 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed by Engr-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F in repairs capacitors 10 Mfd capacities 3 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed by Engr-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F in repairs capacitors 30/40 Mfd capacities 4 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed by Engr-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F in repairs capacitors 50/60 Mfd capacities 4 /6 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed by Engr-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
S&F in repairs capacitors 80/100 Mfd capacities 4 pin for ACs/ Walk- in- cooler etc , complete all as specified and directed by Engr-in-Charge. Make:- Asian/Tipcon/Usha/Epcos/Havells
Supply only in replacement of V Belt, 'B' section (17x11mm) of B-29 size, complete all as directed. Make : Fenner / Dunlop.
All as per srl item No. 61.00 here-in-before but B-36 size.
All as per srl item No. 61.00 here-in-before but B-41 size.
Supply only in replacement of Step Controller with digital display, More than 5 steps, for Hot Water Generator wall as per sample, complete all as directed. Make - Rapid cool / Honeywell.
Paring, trimming and vending tree branches and near AC plants, including taking all precautions while working on site using own T&P by the contractor. Note :- (i) Inside and upto 3 meter outside perimeter of plant shuld be neat and clean. (ii) Paring/trimming of branches shall be done after obtaining necessary direction in writing by the Engineer-in-Charge to avoid any casualty.
Quarterly Periodical, preventive & comprehensive maintenance by dis-assembly, repairing, overhauling, servicing & testing of complete inner tank, Elements, inlet and out let pipe, valves of Hot water generator installed at AC plant including descaling, replacement of gaskets complete incl painting with two coat of heat resistant paint of smoke grey colour complete.
Supply only, in replacement, of three phase heating element capacity 20KW( set of 06 Nos) capacity, ISI marked of existing shape and size suitable for hot water generator and making electric connections and taking down old unserviceable heating elements, complete all as directed. Make : Daspass / Theata
Quarterly Periodical, preventive & comprehensive maintenance by dis-assembly, repairing, overhauling, servicing & testing of complete industrial RO plant 500 ltrs/hrs system complete with Vessels, filter media, pressure pump & replacement of damage PVC pipe line/ leakage complete and replacement of following parts:
S&F inreplacement of vessel paintier with filter media for RO plant 500ltrs/hrs complete all as directed.
S & F Adaptors and SMPS 12 Volt DC complete all as directed.
S & F UV Components complete all as directed.
Sand filter media complete all as directed.
Carbon filter media complete all as directed.
S&F membrane filter for 500 ltrs/hrs complete all as directed.
S&F inreplacement of dosing puimp complete with inlet & out let valve complete all as directed.
Anti scalent chemical complete all as directed.
Quarterly Periodical, preventive & comprehensive maintenance by dis-assembly, repairing, overhauling, servicing & testing of complete industrial RO plant 50 ltrs/hrs system complete with Vessels, filter media, pressure pump & replacement of damage PVC pipe line/ leakage complete and replacement of following parts:
S&F RO Booster Pumps for 50 ltr /hrs complete all as directed.
S&F RO membranes for 50 Ltrs /hrs to remove the major part of TDS up to 98% complete all as directed.
S&F Adaptors DC supply complete all as directed.
S&F UV Components complete all as directed.
S&F Filter Housing complete all as directed.
S&F carbon filter complete all as directed.
S&F Filter Cartridges complete all as directed.
S&F UF Membranes complete all as directed.
M&L for flex sheet glow sign board duly printed compurised letter as directed fixed over square bar duly welded in rectagular shape including fixed the tube light fitting box type one No per Sq mtr area,Tube lights to be properly fit in connectors with clippers. Frame - 1”x1” cubic square pipe 16 gauge. Galvanized Metal sheet box – side 26 gauge powder coated and back 28 gauge incl taking out old board complete all as directed.
Supply only Single phase preventer with Auto switch . Type- Cat No 2.BSP-2, complete all as specified and directed by Engineer - in - Charge complete all as directed. Make- Bentex / Minilec
Supply only MCCB (AC 415 V) with adjustable thermal & adjustable magnetic setting Four pole 400 Amp 36 KA, complete all as specified and directed by Engineer - in - Charge. Make : GE or equivalent C &S /Legrand
Supply only MCCB (AC 415 V) with adjustable thermal & adjustable magnetic setting Four pole 320 Amp 36 KA, complete all as specified and directed by Engineer - in - Charge. Make : GE or equivalent C &S /Legrand
Supply only MCCB of capacity , 250 Amps ,04 pole ,415 V, 36 KA Breaking capacity with fixed thermal magnetic release, complete all as specified and directed by Engineer - in - Charge. Make- GE or equivalent C &S /Legrand
Supply only MCCB 200 A, 4 Pole, 415 V, 36 KA Breaking capacity, with fixed thermal magnetic release, complete all as specified and directed by Engineer - in - Charge. Make- GE or equivalent C &S /Legrand
Supply only MCCB 100 A, 3 Pole, 415 V, 35 KA Breaking capacity, with fixed thermal magnetic release, complete all as specified and directed by Engineer - in - Charge. Make- GE or equivalent C &S /Legrand
Supply only Moulded Case Circuit Breaker (MCCB) (AC 415 V) with adjustable thermal & adjustable magnetic setting Three pole 63 Amp 25 KA , complete all as specified and directed by Engineer-in-charge. Make : GE or equivalent C &S /Legrand
Supply only Motor protection circuit breaker thermal overload relays suitable for ML contactors relay range 10-16A, complete all as specified and directed by Engineer-in-Charge. Make-Havells/L&T/Legrand
Supply only Power contactor 3 pole Type MNX 18 AC 3 rating 18 A with auxiliary contact 2 NO + 2 NC , complete all as specified and directed by Engineer-in-Charge. Make- L&T/Legrand
Supply only Power contactor 3 pole Type MNX 70 AC 3 rating 70 A with auxiliary contact 2 NO + 2 NC , complete all as specified and directed by Engineer-in-Charge. Make- L&T cat part No. ST19002 or equivalent in Legrand
Supply only Power contactor 3 pole Type 3 ML AC 3 rating 40 A with auxiliary contact 2NO + 2NC, complete all as specified and directed by Engineer-in-Charge. Make- L&T cat part No - SS90721 or equivalent in Legrand
Supply only Power contactor 3 pole Type MNX 25 A AC 3 rating 25 A with auxiliary contact 2NO + 2NC, complete all as specified and directed by Engineer-in-Charge. Make- L&T cat part No - SS90921 or equivalent in Legrand
Supply only Power contactor 3 pole Type 1.5 ML AC 3 rating 25 A with auxiliary contact 2 NO + 2 NC, Cat No - SS91851 complete all as specified and directed. Make- L&T/Legrand
M&L for replacement of Cable 3 core flexible heavy duty copper cable of size 4 sqmm of AC , Water Cooler, stabilizer etc. (Make-Plaza/Finolex /Polycab)
M&L for replacement of Cable 3 core flexible heavy duty copper cable of size 6 sqmm of AC , Water Cooler, stabilizer etc complete all as specified and directed. Make-Plaza/Finolex /Polycab
M&L for shifting/installing Split type Air conditioner of any 3/4 Ton capacity complete with piping and copper tubing arrangements including fixing the suction unit on wall and making good as existing as well as making electric connections all as directed by Engr-in-charge. Note :- Copper tubing ,drain pipe and other insulation material measured under relevant item).
S&F insulation of copper tubing wherever required complete all as specified & directed by Engr -in - Charge. Note : Insulation of cold&return air copper tuning measured as one running meter.
S&F Copper pipe 20 mm dia with insulation for split AC complete all as specified & directed by Engr -in - Charge.
S&F Copper pipe 12 mm dia with insulation for split AC complete all as specified & directed by Engr -in - Charge.
M&L for scraping down, cleaning and preparation of old painted surface, applying one coat of synthetic enamelled paint to AC installation Central type AC Plant 2x75 TR all as per existing colour code including sign writing as directed. (AC installation comprising of compressor, motor condenser, pipe line, panel board, valves, AHU cooling tower, Chillar pipe and display board) marking direction of flow and writing SM Nos and MES Nos of size not less than one inch complete all as specified and directed.
M&L for scraping down, cleaning and preparation of old painted surface, applying one coat of synthetic enamelled paint to AC installation Central type AC Plant 3x37.5 TR all as per existing colour code including sign writing as directed. (AC installation comprising of compressor, motor condenser, pipe line, panel board, valves, AHU cooling tower, Chillar pipe and display board) marking direction of flow and writing SM Nos and MES Nos of size not less than one inch complete all as specified and directed.
M/S SS Tarders
ENVIRO TECH SERVICES
ANSARI REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .