Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC BEINGH LOWEST BIDDER | |
| 2 | L2₹54.2 L+₹2.2 L (4.14%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹65.7 L+₹13.7 L (26.3%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | Rejected-Technical PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | - | Rejected-Technical BEING ENLISTED TWO CLASS BELOW THE ELIGIBLE CLASS |
Tender Value
₹64 L
EMD Value
₹1.2 L
Closing Date
20 Mar 2023, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
REPAIR/MAINTENANCE OF LT NETWORK SYSTEM AND OLD UNSERVICEABLE PERIMETER AND EXTERNAL LIGHT FITTINGS WITH LED LIGHTS AND MAINTENANCE OF JUNCTION BOXES, CABLING AND ALLIED WORKS UNDER GE(WEST) JABALPUR
2023_MES_575019_1
81972/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE WEST JABALPUR
₹1.2 L
Yes
21 Apr 2023
14 Jan 2023
22 Mar 2023
14 Jan 2023
20 Mar 2023
27 Feb 2023
14 Jan 2023 - 4 Feb 2023
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
Supply and laying sand cushioning to under ground cable in trenches/ existing cable trenches/ducts, in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed . ( Note : Punned thickness shall be measured for payment)
Supply and laying the Brick with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed.
M&L for removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from LT poles and supply, fixing and stretching new ACSR conductors of any size and type for over head LT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of following cross sections including jointing materials such as cable glands & lugs etc including taking out/dismantling of old unserviceable cable complete all as specified and directed. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:
10 Sqmm 2 core
16 Sqmm 4 core
25 Sqmm 4 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
150 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
M&L in repair GI Tubes , light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed, of following size :
40 mm bore
50 mm bore
80 mm bore
Supply, laying & fixing in repair double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc. all as specified and directed of size 50 mm outer dia and 38 mm inner dia complete all as specified and as directed ( Make:- Telerex/Tirupati or equivalent as approved by GE)
Supply and fixing MCCB 4 pole 63 Amps rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 100 Amps rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 160 Amps rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 200 Amps rupturing capacity 25 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 250 Amps rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 315 Amps rupturing capacity 35/36 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 400 Amps rupturing capacity 50 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 630 Amps rupturing capacity 50 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm , 5 way having terminals for termination of cable with necessary nuts and bolts ,Make - Hansal including -02 Nos polycarbonate cable gland Make :Hansal, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps Make - Legrand in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.
S&F in repair change over switch 100 Amps ON load in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
S&F in repair change over switch 200 Amps ON load in sheet enclosure four pole to be fixed on wall with FI 32X6mm, nuts, bolts, washers etc. complete with all electric connection complete all as specified and directed.
Drilling (Horizontally) to existing road (maximum 10M wide) suitable for passing GI tubing of dia upto 80mm/ 100mm as required at site complete all as specified and directed. Note:- All necessary T&P required at site for drilling shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account.
S&F the straight through joint LT from 25 sqmm 3.5/4 core to 95 sqmm 3.5 core with jointing all as required and directed.
S&F the straight through joint LT from 120 sqmm 3.5 core to 240 sqmm 3.5 core with jointing all as required and directed.
Supplying and fixing in repair1100 volts grade heavy duty cable PVC insulated aluminium conductor 10 sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
Disconnecting, dismantling existing old unserviceable LT Panel/Feeder pillar box and supply, erection, commissioning and testing outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 1000 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complete and including the followings :
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables.
INCOMING :- MCCB 630 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, electronic release Make Legrand -422075 or equivalent make of ABB, Seimens - 01 No.
OUTGOING : (a) MCCB 250 Amps, 4 pole, 415 volts, 36 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420249, or equivalant in ABB, Seimens - 02 Nos
(b) MCCB 200 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420218, or equivalant in ABB, Seimens - 02 Nos
(c) MCCB 160 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Ics = 100%Icu, Make Legrand-420057, or equivalant in ABB, Seimens - 02 No.
(d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 No
(e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 No.
(f) Current transformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos
(g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01)
(h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos
(j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos.
(k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No.
(l) 02 Nos.Danger Notice Plate duly written in Signal Red colour on aluminium plate in English and Hindi language and of size not less than 150mmx100mm shall be fixed on both front & rear door of the bus bar chamber.
(m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles.Cat Part No 412544 of Legrand - 01 No
(n) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 No
(o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area) Note : Panel will be manufactured by CPRI approved firm . The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
Supply, fixing and connecting in repair PVC insulated, round,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light 45 Watt made up of pressure die cast aluminium housing with high efficiency LED as lighting source with separate driver compartment with IP66 protection and powered by integral, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection, Over Voltage protection, Surge Voltage protection. The Luminaire shall conform to the following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 KV with in-built SPD (vi) Lumen efficacy = LED >140 lm/W and lumen efficacy of system = min 4850 lm
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light 60 Watt made up of pressure die cast aluminium housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to the following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 kV with in-built SPD (vi) Lumen efficacy = LED >140 lm/W and lumen efficacy of system = min 6000 lm
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light 70 Watt, made up of pressure die cast aluminium 100 housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD= max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 KV with in-built SPD (vi) Lumen efficacy = LED >140 lm/W and lumen efficacy of system = min 7000 lm
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light 90 Watt, made up of pressure die cast aluminium housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 kV with in-built SPD (vi) Lumen efficacy = LED >140 lm/W and lumen efficacy of system = min 9500 lm
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light 100 Watt, made up of pressure die cast aluminium housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to the following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 kV with in-built SPD (vi) Lumen efficacy of LED = >140 lm/W and lumen efficacy of system = min 10000 lm
Supply, fixing and connecting, in repair, energy saving and environmental friendly long life LED street light 120 Watt, made up of pressure die cast aluminium housing with high efficiency LED as lighting source with separate driver compartment with IP-66 protection and powered by integral, isolated electronic LED driver. The Luminaire shall conform to the following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI = minimum 70 (v) Surge Protection upto 10 kV with in-built SPD (vi) Lumen efficacy of LED = >140 lm/W and lumen efficacy of system = min 13200 lm
Supply, fixing and connecting, in repair, energy saving, environmental friendly, long life 100 W flood light enclosed in Pure polyester powder coated die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant with LED as light source, suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications:- (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI > 70 (v) Surge Protection upto 10 kV with in-built SPD (vi) Lumen efficacy of LED = >140 lm/W and lumen efficacy of system = min 10000 lm (vii) Operating voltage range: 140 V - 270V
Supply, fixing and connecting, in repair, energy saving, environmental friendly, long life 150 W flood light enclosed in Pure polyester powder coated die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant with LED as light source, suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI > 70 (v) Surge Protection upto 10 kV with in-built SPD (vi) Lumen efficacy of LED >140 lm/W and lumen efficacy of system = min 15000 lm (vii) Operating voltage range: 140 V - 270V
Supply, fixing and connecting, in repair, energy saving, environmental friendly, long life 200 W flood light enclosed in Pure polyester powder coated die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant with LED as light source, suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI > 70 (v) Surge Protection upto 10 kV with in-built SPD (vi) Lumen efficacy of LED = >140 lm/W and lumen efficacy of system = min 20000 lm
Supply, fixing and connecting, in repair, energy saving, environmental friendly, long life 300 W flood light enclosed in epoxy powder coated die-cast aluminium housing in grey finish with heat sink for efficient thermal management, sturdiness & excellent corrosion resistant suitable for highlighting architectural features or area lighting and powered by built-In potted, isolated electronic LED driver with lower THD, Output Open / Short Circuit protection. The Luminaire shall conform to the following technical specifications: (i) IP rating = IP 66 (ii) Power Factor = min. 0.95 (iii) THD = max upto 10 % (iv) CRI > 70 (v) Surge Protection upto 10 kV with in built SPD (vi) Lumen efficacy of LED = >140 lm/W and lumen efficacy of system = min 33000 lm
Notes for items related to LED light fittings : (a) LED CHIP, DRIVER & HOUSING shall be in the same MAKE . (b) DRIVER COMPLIANCES WITH IS LUMINAIRE CERTIFIED BIOLOGICAL TEST REPORT BY OEM LAB APPROVED BY NATIONAL TEST HOUSE. (c) NABL testing Certificate shall be produced at the time of Make approval by the GE. (d) Bidders shall submit LM-80 Report for LEDs and LM-79 report from NABL accredited Lab. (e) Contractor shall furnish a replacement warranty of two years for LED light fittings complete including lamps from the certified date of completion of CA. (f) The product will be replaced free of cost by the contractor in the following cases:- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or Lux) below 90% of claimed values of lumens (or lux ) at 1m of the LED/Luminaires. (iv) All LED light/luminaire must meet the provisions laid down in IS-16101,16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II section 13. (g) Minor items required for completion of job are deemed to be included in the unit rate quoted by contractor. Nothing extra shall be payable on this account.
Supply, fixing, connecting and testing Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw single phase load with contactor 63 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm coper conductor wire in and including providing 50x6mm flat iron clamp, necessary nuts and bolts complete including taking down existing arrangement complete all as specified and directed . (Make of nature switch - Model No Swadeep-02EC8kw1P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclosure - Sintex or equivalent as approved by GE)
Dismantling/ taking down existing street light switching system and Supply, fixing, connecting and testing Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall mounted enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed. (Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclosurer - Sintax or equivalent as approved by GE)
Supply and Fixing, in repair, LED driver suitable for 45-72 Watt existing LED street light fittings, of the same Make as existing at site complete all as specified and as directed
Supply and Fixing, in repair, LED driver suitable for 90-120 Watt existing LED street light fittings, of the same Make as existing at site complete all as specified and as directed
Repair and maintenance of street light /perimeter light/ security light /garden lights / flood light fitting HPSV/ LED, any type / Make installed on LT/HT poles/ building, by means of replacing any unserviceable parts as and when required complete with labour including taking down / dismantling, re-assembling and re-fixing the fitting at its original location with proper alignment and making good all defects including replacing of nuts/bolts/PVC connections etc and keeping the light fitting in working condition throught out the life cycle of LED light complete all as specified and as directed. ( Note : Defective / worn out parts / fittings will be measured and paid for separately as " Supply only" against relevant items of this BOQ)
S&F in replacement 3 Layer PPR Pipes, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete for outer dia 20 mm (PN-16) complete all as specified and as directed.
Material and labour for painting to steel tubular pole/Rail Pole of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with black and white synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed. ( Note : Trimming of tree branches around LT/HT line is deemed to be included in the unit rate quoted against this item.)
Schedule of credit amount of Rs. 2,05,240.00 to be deducted during AOC
Sachdeva Enterprises
New Era Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .