Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.8 L+₹98,868.91 (3.21%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹31.9 L+₹1.1 L (3.60%)Rejected-Finance A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹32.6 L+₹1.8 L (5.91%)Rejected-Finance 503 LAJPAT NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹33.1 L+₹2.3 L (7.51%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹33.8 L
EMD Value
₹67,700
Closing Date
9 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALWAR
GE ALWAR
SPL REPAIR TO BLDG NO ML-54 (SINGLE OR ACCN) AT ML LINE ALWAR
2021_MES_474256_1
8021/E8
Open Tender
Civil Works
Item Rate
180 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹67,700
Yes
9 Dec 2021
10 Sept 2021
11 Oct 2021
10 Sept 2021
9 Oct 2021
24 Sept 2021
10 Sept 2021 - 23 Sept 2021
60 days
Amount
Demolition of brick/stone masonry built in cement/lime mortar of any mix including all quoins pillar ashlars masonry and removal complete all as specified& directed by Engr-in-Charge.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M & L for rubble walling brought upto courses, well bounded, bedded and soildly hearted, built in cement mortar 1:6 but except stone complete all as specified and directed. Note:- Old serviceable stone obtain from Srl item No. 1.00 shall be used.
M&L Plain cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) set in cement mortar 1:6 as in coping of brick masonry wall including weathering slightly rounded or chamfered angles and throating as directed including necessary formwork complete all as specified& directed by Engr-in-Charge.
Demolition of cement concrete (un-renforced) in ground floor and paving. exc.15 cm thickness (below or above ground level.) & removal of rubbish material complete all as specified& directed by Engr-in-Charge.
M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate), 25mm thick, as in Sub base complete all as specified& directed by Engr-in-Charge.
M&L for 100 mm thick PCC 1:4:8 type D -2 using 40 mm graded aggregate as in sub base of path/hardstanding complete all as specified& directed by Engr-in-Charge.
M&L Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and over 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L 50mm thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4, complete all as specified& directed by Engr-in-Charge.
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing types and over screed bed 20 mm thick CM 1:6 cement concrete complete
M&L Glazed ceramic coloured tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendering in cm 1:4 complete all as specified & directed by Engr-in-Charge.
M&L machine cut kota stone slab flooring 20-25mm thick over 20 mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified& directed by Engr-in-Charge.
M&L Machine cut marble slab for platform 18/19mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over 15 mm thick screed bed in CM 1:6 complete all as specified & directed by Engr-in-Charge.
M&L 75 mm thick PCC(1:3:6) type C1 (using 20mm graded stone aggregate ) as in plinth protection finished fair and even complete all as specified& directed by Engr-in-Charge.
M&L 60mm thick machine pressed precast conctete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 , M-35 Grade and over 25mm thick sand complete all as specified and as directed by Engr-in-Charge.
Dismanlting of kerb stone including cement bedding & removed off rubble.
M&L Precast cement concrete solid block factory made in PCC 1:2:4 type B-1 using (20 mm graded stone aggregates ) set in CM 1:6 (size of precast concrete block complete all as specified & directed by Engr-in-Charge.
Taking down cement plaster any description on brick or stone walls etc.
M&L Rendring 10mm thick in CM 1:6 on brick work or concrete surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement all as specified.
M&L for rendering 15mm thick in CM 1:4 on stone wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cement all as specified.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified& directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of Oil bound distemper over a coat of 3mm thick wall care putty of approved tint complete all as specified & directed by Engr-in-Charge.
M&L for preparation of newly plastered/unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
M&L for preparation of old plastered surfaces & applying one coat of white wash on ceiling complete all as specified& directed by Engr-in-Charge.
M&L for preparation of old plastered surfaces of wall and applying one coats of white wash complete all as specified& directed by Engr-in-Charge.
M & L for complete removal of existing treatment on walls applying two coats of oil bound distemper over a coat of 3mm thick wall care putty complete all as directed.
Taking down chowkatts or frames (without taking off shutters from the frame) n exc 1.5 sqm each complete all as specified & directed by Engr-in-Charge.
Taking down chowkatts or frames but with shutters (without taking off shutters from the frame) exc 1.5 sq. m but n exc 4 sq m each complete all as specified& directed by Engr-in-Charge.
Taking down shutter of any decription exc.1Sqm and n.Exc 2 Sqm complete all as specified & directed by Engr-in-Charge.
S&F 35mm thick IInd class hard wood factory made panelled door shutter(two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. the size of rail and stiles as per IS: 1003 (part-I), kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified& directed by Engr-in-Charge.
S&F 35 mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); supplied and fitted to chowkats complete all as specified& directed by Engr-in-Charge.
S & F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples complete all as specified and directed.
M&L for preparation of new wooden surfaces over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified& directed by Engr-in-Charge.
M&L for preparation of old wooden surfaces over 10cm width or girth and applying one coat of synthetic enamal paint (of approved shade) complete all as specified& directed by Engr-in-Charge.
S&F Butt hinges 100mm long medium weight, colled rolled mild steel complete all as specified& directed by Engr-in-Charge.
S&F 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified & directed by Engr-in-Charge.
S&F 150mm Aluminium handles, cast type, anodised complete all as specified & directed by Engr-in-Charge.
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified & directed by Engr-in-Charge.
S&F 65mm length Mortice latch with two levers (vertical type), Aluminium anodised body and fixed
S&F harrison rails,mild steel, chromium plated with fixing brackets, stops, rollers etc.on walls complete all as specified & directed by Engr-in-Charge.
M&L for preparation of old steel surface of any description, exc 10cm in width or girth when unconnected with other painting or when painted in a different tint with one coats of synthetic enamel paint complete all as specified & directed by Engr-in-Charge.
Dismantling framed timber scantlings 40 sq. cm and over in section, in any position complete all as specified.
Excavation in post holes each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplush soil to a distance n exc 50m and making good surface complete all as directed by Engineer-in-charge and all as specified.
M&L for PCC Type C2 1:3:6 (40 mm graded stone aggregate) Cement concrete in foundations, filling and mass-concrete complete all as specified & directed by Engr-in-Charge.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floor in PCC 1:2:4 type B-0 to match the existing floor.
M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified & directed by Engr-in-Charge.
Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed by Engineer-in-charge and all as specified.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified & directed by Engr-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified & directed by Engr-in-Charge.
M& L for Cutting holes into or through but in stone walls built in cement mortar or cement lime mortar and walls of cement concrete. and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required superficial area N exc 150 sqm cm for purlin, rafter complete all as directed by Engr-in-charge.
S&F anodized aluminium frame and other sections for doors, windows, ventilators, partitions, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed.
S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed.
S&F anodized aluminium door shutters, aluminium section weighing 0.55 kg/m, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodized aluminum snap beading screws etc. complete all as specified & as directed.
S&F door closer hydraulically regulated, designation No. 3, aluminium (Die cast) body, universal type (ISI marked), fixed in repairs, complete all as specified & as directed.
S&F for powder coated of any colour as approved anodised aluminium grill of approved pattern for windows/ ventilators/doors complete all as specified and directed.
S&F Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staple complete all as specified& directed by Engr-in-Charge.
Supply only sheet glass ordinary quality,in squares n. exc. 0.5 SQM each 4.80 mm thick complete as directed by Engineer-in-charge
Demolition Mud in roofs, any thicknes, including plastering , existing tretement and cleaning (whether full thickness removed or only or part there of) etc in all respect and preparing it for further treatment and taking out and disposal of debris & rubbish to a distance exc 1 Km but not exc 1.5 Km complete all as specified & directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in roof padding, laid to a minimum consolidated thickness of 25 mm as leveling course, laid and compacted in min slope 1:30 over roof complete all as specified& directed by Engr-in-Charge.
M&L screed laid 15mm thick in CM 1:4 with water proofing compound over green concrete surface(WPC will be measured and paid seperately) surface finished even and smooth (without using extra lime or cement) complete all as specified& directed by Engr-in-Charge.
M&L Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m including cleaning surfaces over bituminious primer complete all as specified & directed by Engr-in-Charge.
M&L APP based plymeric membrane minimum weighing 3 Kg/Sqm and minimum 3 mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any thickness, including cover fillets complete all as specified and directed.
M&L False ceiling with ArmGyp-FB ceiling tiles of 595 x595 (as approved by GE) fixed with and including galvanised iron powder coated inverted "T" or "L" section (concealed GI frame work) of mettalic or equivalent suspended from ceiling with provn of galvanised wire 4 mm dia and wall taping screw including butterfly clip, hold down clips for fixing the board to frame complete all as per manufacurers instructions all as directed and specified. (a) size of main tee 39 x 24.4 x 0.8 mm (b) size of wall angle 22.2 x 22.2 x 0.65 mm (c) size of grid 0.61 x 0.61 mm complete all as specified & directed by Engr-in-Charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in soft/loose soil complete all as specified & directed by Engr-in-Charge.
Returning filling in incl spreading levelling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified & directed by Engr-in-Charge.
Removal of excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified& directed by Engr-in-Charge.
Taking down carefully, copper / aluminium unserviceable /perished point wiring any type for light/ fan/ socket or power complete including fittings such as switches, ceiling roses, pendant holders, lamp holders, bracket holders, regulators sockets, light fittings etc, and making good to disturbed surfaces of wall/floor/ceiling etc, complete, all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including wooden boxes fixed on wall with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
All as per serial item No. 72.00 here-in-before but for one ceiling fan point controlled by one switch and regulator.
All as per serial item No. 72.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No. 72.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per serial item No. 72.00 here-in-before but for one 3 pin socket outlet 15/16 Amps with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts complete all as specified and directed.
S&F socket outlet for 3 pin, 5/6 Amp, flush type 240 Volt complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin 5/6 & 15/16 Amp, flush type 240 Volt complete all as specified and directed.
S&F fan regulators electronic step up type and connecting up, ISI marked flush type, 120 watt, 240 volts complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x50mm two or three terminals complete all as specified and directed.
S&F decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt with LED tube 6000K of model E-LITE LED Pride Plus and connecting up with and including three core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete all as specified & directed. Make :- Havells Cat Part No LHEXBLP7PN1W018 or equivalent of Syska / Crompton Greaves as approved by GE
S&F sheet metal enclosures, double door type, suitable for fixing MCB,s, SPN with 200 Amps rated bus bar, 8 way, 240 volts complete all as specified and directed.
S&F MCB 32 Amps, single pole & neutral, 230 Volts complete all as specified and directed.
S&F MCB 6 to 32 Amps, single pole, 230 Volts complete all as specified and directed.
S&F 2nd class hard wood rectangular block open recessed of size 30x25x5 cm depth with 3mm thick hylum/Bakelite sheet on top grouted with 4 Nos bolts for DB complete all as specified and directed.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including suitable size of heavy duty PVC conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed on surfaces of wall/ceiling including taking down old unserviceable wiring complete all as specified and directed. Note:- 02 runs of 6 sqmm size, 01 run of 6 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 16 sqmm 2 core laid in trenches, along poles through pipes etc complete all as specified & as directed. (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately including taking down old unserviceable XLPE cable (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete all as specified & directed.
M&L dry sand (Tibba sand) and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete.
Disconnecting & taking down existing ceiling fan / exhaust fan / geyser of any capacity, any make, any size and depositing in store yard of AGE E/M and refixing the same serviciable ceiling fan / exhaust fan / geyser including making connections with DBs/Sub main and testing complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part I and connection to main switch board or panel and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, PCC chamber (1:3:6) type C-1, charcoal and salt mixed layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, 75 mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 m away from the earth electrode. The pipe for watering shall be provided in slanting manner
M/s S Amarjit Singh
Hitesh Construction
ALAKNANDA ENTERPRISES
shiva construction
M/S JINDAL ENTERPRISES
TARKESHWAR DASS CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .