Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.7 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹34.4 L+₹95,891.07 (2.86%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹37.3 L+₹3.8 L (11.2%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹38.1 L+₹4.6 L (13.9%)Rejected-Finance | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹39.7 L+₹6.2 L (18.6%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹44.3 L
EMD Value
₹88,600
Closing Date
29 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) FARIDABAD
GE (AF) FARIDABAD
PROVN OF CERTAIN MINOR WORKS/LBW WORKS AT AF STN DADRI IN AOR OF GE (AF) FARIDABAD
2024_MES_640230_1
GE (FBD)/AF-81/2023-2024
Open Tender
Civil Works
Item Rate
180 days
DADRI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹88,600
9 Apr 2024
1 Feb 2024
2 Mar 2024
1 Feb 2024
29 Feb 2024
15 Feb 2024
1 Feb 2024 - 8 Feb 2024
Amount
Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth for foundation etc in soft/loose soil complete in all respect as specified and directed by Engineer-in-Charge.
M & L for cement concrete as in foundation filling subbase or mass concrete using cement concrete type D2 1:4:8 (40 mm graded crushed stone aggregate) complete in all respect as specified and directed by Engineer-in-Charge.
M&L for brick work with sub-class'B' bricks,straight or curved on plan exc 6 m mean radius built in CM 1:6 complete in all respect as specified and directed by Engineer-in-Charge.
M&L cement concrete type B0 1:2:4 (20 mm graded crushed stone aggregate) Providing, in coping etc complete in all respect as specified and directed by Engineer-in-Charge.
M&L for 15mm thick cement plaster in cement mortar (1:4) finished even & smooth without using extra cement on brick/concrete surfaces complete in complete in all respect as specified and directed by Engineer-in-Charge.
M&L for Returning,filling in,including spreading,levelling,watering and well ramming in layers not exc 25 cm complete in all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5 m above ground level complete in all respect as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls over a coat of alkali resistant priming paint complete in all respect as specified and directed by Engineer-in-Charge.
M&L for structural steel framed work as in doors or gates of angle or angle iron cooler stand, other section with gusset plates, rails, braces etc complete, drillled for fixing of steel sheeting or other covering. Doors to be prepared for hanging or sliding with and incl either hooks and hinge or steel hanging door fittings and similar works confirming toFe 410-W (Gde E-250 quality-A) and fixing complete in all respect as specified and directed by Engineer-in-Charge.
Cutting holes in brick walls in cement mortar exc half brick but not exc one brick for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B-1 as using 20mm graded crushed stone aggregate required and depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall, complete in all respect as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4, type B-1 (Using 20 mm graded crushed aggregate) as in, inserting hold fast, bed plates, pintle blocks, ancho-rage blocks, bonders(for stone walling) corbels, brackets, etc (of any section indicated) with plain fair faces, including chamfers, weatherings, throating etc, complete in all respect as specified and directed by Engineer-in-Charge.
M&L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete in all respect as specified and directed by Engineer-in-Charge.
Taking down cement plaster, any description, on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc and disposal of debris complete in all respect as specified and directed by Engineer-in-Charge.
Dismantling structural steel work including doors, gates but excluding framed complete in all respect as specified and directed by Engineer-in-Charge.
M&L for Rendering,15 mm thick, in cement mortar 1:4 over brick or concrete surfaces, finished fair and even without using extra cement, mixed with water proofing compound @ 3% by weight of cement complete in all respect as specified and directed by Engineer-in-Charge. Note:-Integral water proofing compound shall be measured and paid separately
Supply only integral water proofing compound conforming to IS-2645-1975 complete in all respect as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works complete in all respect as specified and directed by Engineer-in-Charge.
M&L RCC 1:2:4 type B1 nominal mix using 20mm graded crushed stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete in all respect as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.rough finished complete in all respect as specified and directed by Engineer-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concretearticles complete in all respect as specified and directed by Engineer-in-Charge.
Material and labour reinforcement TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete in all respect as specified and directed by Engineer-in-Charge.
Material and labour reinforcement TMT bars 5 mm dia and over up to and including 10mm dia in stirrups,spacers and binders, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete in all respect as specified and directed by Engineer-in-Charge.
S&F MS holdfast, hook and pintle hinges, large hasp and staples, clamps, hooks for hanging fans and similar small articles conforming to Fe-290 Gde E-165 including necessary welding etc. and fixed in position complete in all respect as specified and directed by Engineer-in-Charge.
S&F 100 mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required complete in all respect as specified and directed by Engineer-in-Charge.
S&F MS sliding door bolt, plate type, 300mm long, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts & nuts, 4 on bolt plate and 2 on staple plate and fixed complete in all respect as specified and directed by Engineer-in-Charge.
S&F mild steel barrel tower bolt, stove enamelled black, with bright bolt, 150mm long, 10mm dia of shoot and fixed complete in all respect as specified and directed by Engineer-in-Charge.
S&F 1.25 mm thick Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete in all respect as specified and directed by Engineer-in-Charge.
M & L Reinforced cement concrete (design mix) in for RCC Beams, cantilevers, bressummers, lintels over 1.5m span using M25 grade of concrete using 20mm graded stone aggregate complete in all respect as specified and directed by Engineer-in-Charge.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete in all respect as specified and directed by Engineer-in-Charge.
Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete in all respect as specified and directed by Engineer-in-Charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick horizontal or slopping rough finished flat surfaces complete in complete in all respect as specified and directed by Engineer-in-Charge.
Use and waste of form work to edges of concrete slabs horizontal of slopping rough finished flat surfaces exc 10 Cm but not exc. 20 CM wide complete in all respect as specified and directed by Engineer-in-Charge.
M&L brick work with sub class "B" bricks, straight or curved on plan to any radius in half brick wall, built in cement mortor (1:4) complete in all respect as specified and directed by Engineer-in-Charge.
M&L rendering 5 mm thick cement plaster in cement mortar (1:4) on brick/concrete surfaces on ceiling finished even & smooth without using extra cement complete in all respect as specified and directed by Engineer-in-Charge.
M&L rendering 15mm thick cement plaster in cement mortar (1:6) finished even & smooth without using extra cement on brick/concrete surfaces complete in all respect as specified and directed by Engineer-in-Charge.
M&L two coat of oil bound distemper over 3mm thick wall care putty on new plastered surfaces including necessary prepararion complete in all respect as specified and directed by Engineer-in-Charge.
M&L three coat of white wash on new plastered /conceretesurfaces on ceiling including necessary prepararion complete in all respect as specified and directed by Engineer-in-Charge.
S&F Wash basins, Vitreous China (flat back or angle back type or counter top) size 550x400, including cutting for and pinning in ends of brackets incl waste pipe complete in all respect as specified and directed by Engineer-in-Charge.
S&F 15 mm bore dia fancy type chromium plated angle valves cast copper alloyes, screwed down high pressure with crutch or butterfuly handle , screwed both ends for iron pipe or for unions and fixed complete in all respect as specified and directed by Engineer-in-Charge.
S & F Vitreous China wash down water closet pan (pedestal pattern), white Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and long arm cast iron trap including PCC bedding complete incl long bend in complete in all respect as specified and directed by Engineer-in-Charge.
S & F Vitreous china urinal full stall type bowl type complete including waste pipe and providing and fixing plugs, bedding urinals against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinals back in cement fixing flush pipe grating and union for discharge pipe complete in all respect as specified and directed by Engineer-in-Charge.
M&L 15 mm bore GI tubing medium grade with all fittings and fixed complete to walls, ceiling or laid in floor including necessary cutting/chasing in walls made of brick/concrete surface complete in all respect as specified and directed by Engineer-in-Charge.
M&L 20 mm bore GI tubing medium grade with all fittings and fixed complete to walls, ceiling or laid in floor including necessary cutting/chasing in walls made of brick/concrete surface complete in all respect as specified and directed by Engineer-in-Charge.
S&F, bib taps fancy type chromium plated cast copper alloys with crutch or butterfly handeles, screwed down, screwed for iron pipe or for brass ferule & fixed for 15mm bore GI pipe complete in all respect as specified and directed by Engineer-in-Charge.
S & F steel windows with side hung shutter including box type hinges including steel handle, and steel peg stay, complete in all respect with glazing bars, dovetailed or welded complete in all respect as specified and directed by Engineer-in-Charge.
S & F steel ventilator fixed type with glazing bar complete in all respect as specified and directed by Engineer-in-Charge.
S & F framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars complete all as specified conforming to Fe-290 Gde E-165 complete in all respect as specified and directed by Engineer-in-Charge.
S & F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n. exc 0.5 Sqm each pane complete in all respect as specified and directed by Engineer-in-Charge.
M & L for brick ballast Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete in all respect as specified and directed by Engineer-in-Charge.
M&L PCC (1:3:6) type C-2, using 40mm graded stone aggregate, 75 mm thick as in plinth protection finished even and smooth without using extra cement complete in all respect as specified and directed by Engineer-in-Charge.
S&F 500 ltr capacity rotationally moulded polythene white colour three layered water storage tanks (cylindrical vertical with closed top) of approved make incl 15 mm float valve hoisted and fixed at position complete in all respect as specified and directed by Engineer-in-Charge.
S & F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet re-inforced with MS square tube, S & F in opening complete in all respect as specified and directed by Engineer-in-Charge.
S & F factory made solid panel PVC door shutter30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heatmoulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete in all respect as specified and directed by Engineer-in-Charge.
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodized complete in all respect as specified and directed by Engineer-in-Charge.
S&F aluminium anodised barrel tower bolt of extruded section length of bolts 150 mm complete in all respect as specified and directed by Engineer-in-Charge.
S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete in all respect as specified and directed by Engineer-in-Charge.
S&F 10 ltrs capacity PVC valveless, syphonic action type, flusting cistern, low level, white, with inlet ball valve, float and handle including brackets in repair complete in all respect as specified and directed by Engineer-in-Charge.
S&F PVC connection 15mm size with PTMT nuts of length 450 mm, in repair in complete in all respect as specified and directed by Engineer-in-Charge.
S&F CP fancy type health faucet with 1 mtr long flexible spring type steel tube & hook complete in all respect as specified and directed by Engineer-in-Charge.
S&F Pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' withlong screwed shanks and fly-nuts, screwed for iron pipe and fixed complete in all respect as specified and directed by Engineer-in-Charge.
S&F brass chromium plated tubular tower rail 20mm dia complete in all respect as specified and directed by Engineer-in-Charge.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick, (square/rectangular), area of each tile exceeding 0.11 sqm but nexc 0.18 sqm, in floors etc. set & jointing in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finish, complete in all respect as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic tiles in vertical surface 300X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and pointing in white or coloured cement to match over and including 10 mm thick plaster in cement mortar (1:4) as in backing coat to receive wall tiles complete in all respect as specified and directed by Engineer-in-Charge.
M&L 75 mm thick PCC 1:4:8 type D-2 (using 40mm grade stone aggregate) as in Sub floors,Sub bases ,flooring etc complete in all respect as specified and directed by Engineer-in-Charge.
M&L for 40 mm thick PCC 1:2:4 , Type B-1 (using 20 mm graded stone aggreagte) as in under laying layer etc, complete in all respect as specified and directed by Engineer-in-Charge.
S&F interlocking aluminium powder coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Tee 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm complete all as specified and S&F Water Resistance glass fibre reinforced Gypsum board of 12 mm thick for ceiling complete in all respect as specified and directed by Engineer-in-Charge.
S&F 75 mm PVC (SWR) vent cowl complete in all respect as specified and directed by Engineer-in-Charge.
S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete in all respect as specified and directed by Engineer-in-Charge.
S&F 75 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete in all respect as specified and directed by Engineer-in-Charge.
S&F 75 mm PVC (SWR) bends any radius complete in all respect as specified and directed by Engineer-in-Charge.
S&F 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete in all respect as specified and directed by Engineer-in-Charge.
S&F 110 mm PVC (SWR) junction single,(Single T) equal or unequal complete in all respect as specified and directed by Engineer-in-Charge.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft loose soil complete in all respect as specified and directed by Engineer-in-Charge.
M&L for Hard core of gauge not exceeding 63 mm deposited spread and levelled in layers not exc 15 cm thick watered and rammed to a true surface complete in all respect as specified and directed by Engineer-in-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade of approved make with grey cement and pigment complete in all respect as specified and directed by Engineer-in-Charge.
M&L for 30 mm thick Sand filling under floors or as in sand cusioning for interlocking paver block fixing complete in all respect as specified and directed by Engineer-in-Charge.
M&L for Concrete bed to drain pipes150 mm dia including packing under, and haunching against the sides of pipes after they are laid and tested complete in all respect as specified and directed by Engineer-in-Charge.
M&L for RCC drain pipes class NP3 With collors 150 mm dia laid in trenches and joints complete in all respect as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C2 ( 40mm graded stone aggregate) as in sub base and mass concrete complete in all respect as specified and directed by Engineer-in-Charge.
Providing precast cement concrete type B-1 1:2:4 using 20mm graded crushed stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete in all respect as specified and directed by Engineer-in-Charge.
M&L for point wiring with Modular /single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit / concelled medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thick hylam laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete in all respect as specified and directed by Engineer-in-Charge for following :- One light/fan point controlled by one switch.
All as per item No 83 above but One socket point on same board with other switches
All as per item No 83 above but One 3 pin 5 Amps socket outlet independent with cables 1.5 sqmm size.
All as per item No 83 above but with conductor of size 2.5 Sq mm (nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 1.5 Sq mm PVC insulated stranded copper conductor cable.
S&F Modular switch 1 way 6A, 1 module complete all as specified and as directed by Engr-in-Charge.
S&F Modular switch 1 way 16A, 1 module complete in all respect as specified and directed by Engineer-in-Charge.
S&F Socket, 6A - 2/3 pin combined 2 module complete in all respect as specified and directed by Engineer-in-Charge.
S&F Socket 6A/16A - 2/3 pin combined 2 module complete in all respect as specified and directed by Engineer-in-Charge.
S&F White cover plate with frame,3/4 module complete in all respect as specified and directed by Engineer-in-Charge.
All as per item No 91 above but but 6 module
All as per item No 91 above but but 8 module
S&F Metal flush box/ PVC box 3/4 module complete in all respect as specified and directed by Engineer-in-Charge.
All as per item No 94 above but but 6/8 module
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete in all respect as specified and directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose , complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable and tubes wit suitable size complete in all respect as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete in all respect as specified and directed by Engineer-in-Charge.
S&F sheet metal enclousers MCB type DB suitable SPN 12 way 200 Amp rated bus bar double door type complete in all respect as specified and directed by Engineer-in-Charge.
S&F MCB SPN capacity 32 Amps, 240 V complete in all respect as specified and directed by Engineer-in-Charge.
S&F MCB SP capacity 6-32 Amps, 240 V complete in all respect as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete in all respect as specified and directed by Engineer-in-Charge.
Supply, and fixing bus bar chamber 4 Way outdoor type factory made out of CRCA sheet dust & vermin proof , front opening door having locking arrangement totally enclosed weather proof, antirusted powder coated painted including aluminium Bus Bar of 200 Amps rating bus size 45 cm long x 50mm wide x 15mm thick, 440 volts, 3 Phase 4 wire having suitable gap to connect the cables of size 95 Sqmm 3.5 core and bus mounted on suitable type of insulators incl coloured insulating sleeve on each complete with bottom removable gland plates for inccomming and out going cables, bus chamber mounted on MS angle stand made of MS angle 50mm x 50 mm x 5 mm and should having minimium 45 Cm gap below bus chamber incl necessary PCC foundation work complete in all respect as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanisedusing galvanised iron strip 32×6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete in all respect as specified and directed by Engineer-in-Charge.
Supply, laying, testing and connecting cable under ground XLPE insulated screened PVC bedded, galvanised strip or wire armoured, electric power cables ( heavy duty) with 1100 Volts grade with starndedard aluminium conductor inclusive connected with thimbles, nutt bolt by crimping tool etc complete of size 35 sq mm 3.5 core complete in all respect as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of cables/ poles or foundation etc in losse and soft soil getting out complete in all respect as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete in all respect as specified and directed by Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete in all respect as specified and directed by Engineer-in-Charge.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete in all respect as specified and directed by Engineer-in-Charge.
M&L for brick sub class B laid dry in trenches over the cable ad joining each other widthwise for cable protection complete in all respect as specified and directed by Engineer-in-Charge.
Supply and lay pipe galvanized, “ 'medium grade',galvanised,with all fitting laid in trenches 20 mm dia complete in all respect as specified and directed by Engineer-in-Charge.
Supply and lay pipe galvanized, “ 'medium grade',galvanised,with all fitting laid in trenches but 25 mm (1”) dia complete in all respect as specified and directed by Engineer-in-Charge.
Supply and fix Cock,Bib taps,fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed fancy type for size but 20 mm (3/4”) dia pipe complete in all respect as specified and directed by Engineer-in-Charge.
Supply and fix Cock,Bib taps,fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed fancy type for size but 25 mm (1”) dia pipe complete in all respect as specified and directed by Engineer-in-Charge.
Supply and fixing LED Bollard light fitting, Warm white IP 54 powder coated PDC aluminium body with opal diffuser suitable for landscape lighting incl PCC, conduit bend pipe making necessary arrangement for mounting fitting as reqd on site and testing complete in all respect as specified and directed by Engineer-in-Charge.
Supply and fixing LED Bulb, Warm white 10 Watt as reqd on site and testing complete in all respect as specified and directed by Engineer-in-Charge.
M&L for XLPE insulated screened PVC bedded galvanised steel strip or wire armoured LT 1100 Volts grade aluminium conductor of cross sectional area 16 Sqmm 4 core incl thimbles as required with suitable size of calmps on wall/under trenches etc complete in all respect as specified and directed by Engineer-in-Charge.
M/s Kanha Enterprise
36SHRI RADHEY ASSOCIATES
AARSINFRATECH
M/S Yamin
MAA BHAWANI CONSTRUCTION
NAVEEN KUMAR TYAGI
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .