| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹29.2 L+₹1.2 L (4.27%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹37.8 L+₹9.8 L (35.0%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAJPATI CONSTRUCTION L3 | MODI CORPORATION L2 | PRADEEP TIWARI CONTRACTOR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Strip opening of step down transformer of capacity 100 to 200 KVA, indoor /outdoor type of any make after unscrewing nuts & bolts, screws and connected, dismantling carefully connected acesories and removing primary and secondary terminals, top cover, conservator tank, temp gauge,breather,neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers ( to be arranged by contractor) etc. for replacement of defective parts such as replacement of leaking gaskets, replacement of worn out/burnt out studs, checking and cleaning of contacts of tap changer and re-assembling the transformer after replacing the defective parts/repair complete all as specified and directed by Eng-in-Charge | 11 | Job | 2,621 ₹28,831 | 1,500 ₹16,500 | 500 ₹5,500 Lowest |
| 1.01Notes : (i) Payment of defective parts to be replaced shall be measured and paid for separately under respective item of this schedule. (ii) The cost for replacement of packing material such as 5 mm thick rubberised cork sheet top gasket, insulator’s gasket shall deem to be included in the unit rate quoted by the contractor against this item (iii) The repair/strip opening of transformers shall be carried out at site of its installation without taking down/removal of transformer from the site of installation. | ||||||
| 2.00 | All as per item No 1.00 & 1.01 here in before but transformer of capacity 250 KVA and up to 750 KVA complete all as specified and directed | 15 | Job | 2,621 ₹39,315 | 1,600 ₹24,000 | 1,000 ₹15,000 Lowest |
| 3.00 | Disconnecting the electric supply, removing the HT and LT cable connections and taking out the transformer of capacity up to 750 KVA from platform, lifting the transformer with suitable Crane, loading into the goods carrier and shifting the transformer to an approved factory (workshop) for repairs and transporting back installation in its original location including connection of HT and LT cable connections all as directed by Eng-in-charge.
Note:-Repairs to transformer and testing will be measured and paid for separately. | 6 | Each Job | 4,060 ₹24,360 | 2,500 ₹15,000 | 2,300 ₹13,800 Lowest |
| 4.00 | M&L for draining out the transformer oil, removing the inspection cover, lifting the core with suitable crane and removing the winding from the core replacing the unserviceable insulation of LV coil, HV coil and rewinding the unserviceable HV, LV coil turns with new electrolytic copper conductor, drying of core and winding in the oven upto required IR values, assembling the core with new insulation, replace the unserviceable LT, HT bushing washers, oil seal, gasket of inspection cover with new ones, conduct all testing, commissioning complete upto 100 to 200 KVA Transformer all as directed by Eng-in-charge.
Note:- HT/LT bush, transformer oil, LV, HV coils, inspection cover gasket and testing of transformer will be measured and paid separately under relevent items. | 3 | Each Job | 1,900 ₹5,700 | 1,600 ₹4,800 | 1,200 ₹3,600 Lowest |
| 5.00 | All as per item No- 4.00 above but of capacity 250 KVA to 750 KVA | 3 | Each Job | 2,530 ₹7,590 | 1,800 ₹5,400 | 1,600 ₹4,800 Lowest |
| 6.00 | M&L for making LT coil insulation with required gauge of craft paper cotton tape as per specification of old transformer of capacity upto 100 to 750 KVA complete all as directed by Eng-in-charge. | 30 | Kg | 370 ₹11,100 | 200 ₹6,000 Lowest | 200 ₹6,000 Lowest |
| 7.00 | M&L for making HT coil insulation with required gauge of craft paper cotton tape as per specification of old transformer of capacity upto 100 to 750 KVA complete all as directed by Eng-in-charge. | 30 | Kg | 550 ₹16,500 | 250 ₹7,500 Lowest | 300 ₹9,000 |
| 8.00 | M&L for making HT/ LT coil insulation with supper enamelled copper wire of required gauge as per specification of old transformers capacity complete all as specified and directed by Eng-in -charge. | 150 | Kg | 1,243 ₹1,86,450 | 500 ₹75,000 Lowest | 650 ₹97,500 |
| 9.00 | M&L for conducting the folowing tests after repairs of transformers capacity upto 750 KVA including submitting the test report.
(a) IR values of HV to LV, HV to Earth and LV to Earth.
(b) Winding resistance
(c) Radio test
(d) No-load test
(e) Short circuit test
(f) Dielectric strength of oil
(g) transformer tap switch positions
Note:- Contractor shall arrange all measuring instruments/ equipments for testing of transformer. | 26 | Each Job | 1,711 ₹44,486 | 1,600 ₹41,600 | 1,120 ₹29,120 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 May 2026, 6:00 pmClosed
Shri Ankit Goyal, IDSE
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
REPAIR/MAINT OF 11/0.433 KV TRANSFORMER, RELYS, CT/PT, CALIBERATION OF VCBs, UPGRADATION OF SUB STATION AND OTHER CONNECTED WORKS AT GE DRONACHAL
2026_MES_761284_1
8987/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHOPAL
Class-D, Category b (i) and as per NIT documents
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER DRONACHAL
₹80,000
Yes
29 May 2026
21 Apr 2026
27 May 2026
21 Apr 2026
25 May 2026
5 May 2026
21 Apr 2026 - 28 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Strip opening of step down transformer of capacity 100 to 200 KVA, indoor /outdoor type of any make after unscrewing nuts & bolts, screws and connected, dismantling carefully connected acesories and removing primary and secondary terminals, top cover, conservator tank, temp gauge,breather,neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers ( to be arranged by contractor) etc. for replacement of defective parts such as replacement of leaking gaskets, replacement of worn out/burnt out studs, checking and cleaning of contacts of tap changer and re-assembling the transformer after replacing the defective parts/repair complete all as specified and directed by Eng-in-Charge | - | Job | - | - |
| - | All as per item No 1.00 & 1.01 here in before but transformer of capacity 250 KVA and up to 750 KVA complete all as specified and directed | - | Job | - | - |
| - | Disconnecting the electric supply, removing the HT and LT cable connections and taking out the transformer of capacity up to 750 KVA from platform, lifting the transformer with suitable Crane, loading into the goods carrier and shifting the transformer to an approved factory (workshop) for repairs and transporting back installation in its original location including connection of HT and LT cable connections all as directed by Eng-in-charge.
Note:-Repairs to transformer and testing will be measured and paid for separately. | - | Each Job | - | - |
| - | M&L for draining out the transformer oil, removing the inspection cover, lifting the core with suitable crane and removing the winding from the core replacing the unserviceable insulation of LV coil, HV coil and rewinding the unserviceable HV, LV coil turns with new electrolytic copper conductor, drying of core and winding in the oven upto required IR values, assembling the core with new insulation, replace the unserviceable LT, HT bushing washers, oil seal, gasket of inspection cover with new ones, conduct all testing, commissioning complete upto 100 to 200 KVA Transformer all as directed by Eng-in-charge.
Note:- HT/LT bush, transformer oil, LV, HV coils, inspection cover gasket and testing of transformer will be measured and paid separately under relevent items. | - | Each Job | - | - |
| - | All as per item No- 4.00 above but of capacity 250 KVA to 750 KVA | - | Each Job | - | - |
| - | M&L for making LT coil insulation with required gauge of craft paper cotton tape as per specification of old transformer of capacity upto 100 to 750 KVA complete all as directed by Eng-in-charge. | - | Kg | - | - |
| - | M&L for making HT coil insulation with required gauge of craft paper cotton tape as per specification of old transformer of capacity upto 100 to 750 KVA complete all as directed by Eng-in-charge. | - | Kg | - | - |
| - | M&L for making HT/ LT coil insulation with supper enamelled copper wire of required gauge as per specification of old transformers capacity complete all as specified and directed by Eng-in -charge. | - | Kg | - | - |
| - | M&L for conducting the folowing tests after repairs of transformers capacity upto 750 KVA including submitting the test report.
(a) IR values of HV to LV, HV to Earth and LV to Earth.
(b) Winding resistance
(c) Radio test
(d) No-load test
(e) Short circuit test
(f) Dielectric strength of oil
(g) transformer tap switch positions
Note:- Contractor shall arrange all measuring instruments/ equipments for testing of transformer. | - | Each Job | - | - |
| - | Filtration/Dehydration of transformer oil of transformers installed at Dronachal Campus Sub station to achieve die electric strength 60 KV at 2.5 mm gap gap as per relevant IS with portable filtration plant, testing of the oil for die electric strength, break down voltage before filtration and after filtration complete all as specified and directed by Eng-in-Charge. (MRS Sub Station)
Note : (All types of T&P required for filtration of transformer oil to be provided by the contractor). | - | Litre | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
GPSC_8987.pdf
Tender Documents • 0.60 MB
PS_8987.pdf
Tender Documents • 0.27 MB
SOC_8987.pdf
Tender Documents • 0.26 MB
BOQ_852741.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .