GE GOMANTAK
GE Gomantak, Vasco Goa 403802
Repair Maintenance to Internal wiring fittings and fixture MCB DB flameproof fittings, ceiling fans exhaust fans geysers at MO Goa and NAD under GE Gomantak Vasco
2019_MES_293556_1
8982/E8
Open Tender
Support/Maintenance Service
Works
180 days
VASCO DA GAMA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE GOMANTAK
₹23,700
Yes
14 Jan 2020
29 Oct 2019
26 Nov 2019
29 Oct 2019
25 Nov 2019
8 Nov 2019
Amount
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing material to store for keeping in safe custody or for taking credit and making good disturbed surface of walls, floors etc complete all as per the existing finish.
Material and labour for point wiring with 1100 V grade 1.5 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FRLS grade, conforming to relevant IS, drawn through and including PVC casing and caping with all accessories fixed on surfaces of wall, ceiling, including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor cable FRLS grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge for the following:-
(a) One light/fan/exhaust fan point controlled by one switch.
(b) One light/fan/exhaust fan point for additional light point on the same switch circuit
(c) One 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per Srl item No 02 but for one light point controlled by one switch with 1100V grade 1.5 Sqmm copper cable FRLS multistranded unsheathed drawn through in stove enamelled steel conduit on wall.
All as per item No 3 above but for 3 pin socket outlet, 5 Amps with 1.5 Sqmm FRLS copper cable on independent board.
M&L for point wiring for one 15 Amp socket outlet independant with 2.5 sqmm copper conductor cable FRLS multistranded unsheathed drawn through & including stove enamalled rigid steel conduit and 2.5 sqmm conductor cable FRLS for earth wire including making connection with common earth and earth dolly including pressed steel terminal boxes concealed in wall with 3 mm thick laminated Hylem sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc all as per directed by Engr-in-Charge.
Material and labour for point wiring with 1100 V grade 4 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FRLS grade, conforming to relevant IS drawn through and including PVC casing and caping with all accessories fixed on surfaces of wall, ceiling, including sunk pressed steel terminal boxes made out of 2 mm thick MS sheet concealed in walls with 3 mm thick laminated Hylem sheet top cover fixed with brass screws for housing switches, socket etc including 4.00 Sqmm single core PVC insulated and unsheathed copper conductor cable FRLS grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge for one 6 pin switch socket outlet 15 Amps on independent board controlled by one switch.
Submain wiring with 4 sqmm 2 Runs of single core multi stranded FRLS PVC insulated unsheathed cable 1100 Volts with copper conductor drawn in and including 25 mm wide PVC casing and caping with all accessories such as tees, elbows, junction box Reducers etc as required along with 1 Run of 4 sqmm single core PVC insulated unsheathed copper conductor as continuous earth wire and connecting to Existing main switch board \ Distribution Board and testing on completion including Taking down old submain wiring any type of conduit complete all as directed.
Supply and fixing submain wiring with 2 runs of 6 sqmm, FR LS PVC insulated, unsheathed, single core, multi stranded, 1100 Volts, copper conductor cable drawn in and including 25/ 32mm wide PVC casing and caping with all accessories such as tees, elbows, junction box, reducers etc as required along with 1 run of 6 sqmm FRLS PVC insulated, unsheathed, single core, multi stranded copper conductor cable as continuous earth wire and connecting to existing main switch board \ Distribution Board and testing on completion including taking down old submain wiring of any type with conduit complete all as directed by Engineer-in-charge. Note : 3 runs of 6 Sqmm cable, PVC insulated, unsheathed, single core, multi stranded copper conductor cable and 1 run of PVC casing/caping 25mm/32mm wide shall be measured as single run.
Supply and fixing switch piano flush type single pole, one way 5 Amp.
Supply and fixing switch piano flush type single pole, two way 5 Amp.
Supply and fixing switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal.
Supply and fixing switch socket combination 2 in 1, 5 pin, 15 Amp flush type universal.
Supply and fixing stepped type electronic fan regulator flush type on existing phenolic laminated sheet
Supply and fixing bell push, flush type, 5 Amps.
Supply and fixing bell Ding Dong AC, 230 volts, single pole.
Supply and fixing ceiling rose, surface bakelite, 65x50 mm, two to three terminals complete.
Supply and fixing in repair LED flood light 50Watts 250 volts 50Hz .
Supply and fixing LED Tube Light fixture 20Watts 4 ft tube complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including removal of old unserviceable one
Supply and fixing LED Tube Light fixture 10Watts 2 ft tube complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size including removal of old unserviceable one
Supply and fixing of Stellar bright 20W LED 6500K Tube complete all as specified & directed by Eng-in-Charge.
Supply and fixing LED Stellar brite linear 10W bulb complete with swivel body action for better focus etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fixing FIAMMA II flameproof 2X20W LED Tubelight fixture with IP 65 Protection etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fixing surface mounted square LED 24W recessed bottom opening downlight for soft diffused lighting etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fixing flame proof rotary type with termination box in LM6, 16 Amps, Single pole 250 Volts.
Supply and fixing flame proof switch socket & plug combined termination box in LM6, 16 Amps, 250 Amps, 2P+earth.
Supply and fixing fluorescent tube 36Watts 240volts 50Hz T8.
Supply & fixing Electronic ballast forfluorescent tube lights36/40 Watts 250volts, 50Hz
Supply & fixing Starter universal for 18/20/36/40/65 Watts 250volts, 50Hz
Supply and fixing lamp holder, PVC/Polycarbonate type with black plate suitable for batten fittings etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and testing complete all as directed by Engr-in-charge.
Supply and fixing sheet metal enclosure (DB) for MCB's, 4 way, single pole and neutral, 240 volts, double door with 100 Amp rated Copper bus bar complete.
Supply and fixing sheet metal enclosure (DB) for MCB's, 8 way, single pole and neutral, 240 volts, double door with 100 Amp rated Copper bus bar complete.
Supply and fixing sheet metal enclosure (DB) for MCBs, 4 way, triple pole and neutral, 415 Volts, double door with 200 Amps rated bus bars complete.
Supply and fixing sheet metal enclosure (DB) for MCCB, vertical type,8 way, triple pole and neutral, 415 volts, double door with 200 Amps rated bus bar .
Supply and fixing sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 20 Amps, 240 Volts complete.Make: Havells / C&S / Schneider
Supply and fixing in repair 4 pole MCCB 100 Amp, 50Hz, 415V with rupturing capacity 16KA with copper spreadding including fixing arrangements and provn of new cable lugs etc and connected to any description all as directed.
Supply and fixing MCB, single pole, 20 & 32 Amp, 240 Volts, 'C' Curve 10KA.
Supply and fixing MCB, single pole and neutral, 6-32 Amp, 240 Volts, 'C' Curve 10 KA.
Supply and fixing MCB, Triple pole , 40 Amp, 415 Volts, 'C' series 10 KA.
Supply and fixing MCB, Triple pole and neutral , 63 Amp, 415 Volts, 'C' series 10 KA. r
Taking down and servicing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt/ washer, rubber bush, canopy and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge.Note: MS nut bolts with spilt pin, Ball bearing and Gun metal bush shall be measured and paid for separately.
Supply only MS Nut bolts with split pin as per sample and as directed by Engineer-in-Charge.
Supply only Ball bearing suitable size of ceiling fan and exhaust-fan of any type and size .Make : SKF/ Tata
Supply only gun metal bush suitable for ceiling fan and exhaust fan any type and size including removing old
M&L opening the body cover of fan any type and make and cutting the existing worn out winding with out damaging the stator removing the coil insulation and putting new insulation of polyster paper, winding with super enameled copper wire of suitable gauge with correct number of turns of auxillary and main winding and varnishing and packing complete including soldering new lead of copper wire testing complete including transportation to work shop and back all as directed by Engr-in-Charge Note : a) Contractor have to make the arrangement for testing of Rewinded fan upto 24hrs at Gmk power house and in case of failure to above said testing a penalty of Rs 200/- per fan shall be deducted from contractors due and rewinding of same once again is bonded. b) Fan should be return to MES yard after rewinding within 10 day from the date of issue otherwise a penalty of RS 10/- per day per fan shall be deducted from contractor is dues.
(a) Ceiling fans 1200/1400 mm sweep
( b) Exhaust fan Upto 300 to 350mm sweep
( c) Wall mounted fan 400mm sweep
M&L flexible wire of size 23/0.0076 for ceiling fan connection including taking down the old unserviceable wire complete all as specified & directed by Eng-in-charge.Make: Polycab / Havells / V Guard
M&L for Preparation of old painted surface of ceiling fan and applying one coat of synthetic enamel paint with spraying painting machine including writing MES number on body of the fan including taking down and refixing and connection and testing complete all as specified & directed by Engr-in- charge.
S&F in replacement fan capacitor 2.5 mfd 240 V AC supply.
14. M & L for Earthing complete with galvanised steel earth plate, electrode, 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to GI wire 4 mm thick dia by mens of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing test point all as specified including necessary earth pit, PCC 1:3:6 chamber be 50mm thick, PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials.
Star Freeze Service
BROTECH
S and G Constructions
Sai Supreme Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .