Loading…
Loading…
Tender Value
₹13.4 L
EMD Value
₹33,380
Closing Date
3 Aug 2026, 11:00 pm4d left
Karnataka Power Transmission Corporation Limited
AEE-4
08022386686
9449875994
Tender for increasing the Vertical clearance by providing 1no of 66KV D/C NBT DD plus 3 KPTCL design type intermediate tower between tower no 7 & 8 of 66kV Subramanyapura - Remco D/C line-2 near Arehalli limits, Gas godown road, in TLM Sub-Division Somanahalli, Bangalore
KPTCL/2024-25/TL/WORK_INDENT1862/CALL-9
KPTCL/2024-25/TL/WORK_INDENT1862/CALL-9
Open
Transmission Line
Two Tender Document System(Two Cover)
KPTCL SEE Transmission And Mantainance Circle BMAZ South Bengaluru
17 documents required · 17 mandatory
The bidder should have satisfactorily completed in the last five years at least one work of Construction of Stations/Transmission Lines/ Erection of Towers/Maintenance or rectification work of EHV Transmission lines/ One Terminal Bay of 66KV class or above voltage class on Total Turn Key, Partial Turnkey basis for the last five financial years in KPTCL/PGCIL/NHPC/NTPC/ any Govt., or public sector under takings & produce experience and performance certificate duly signed by competent authorities not below the rank of the Executive Engineer Electrical, which shall be in satisfactory service for a period of One year prior to date of submission of the Bid
The Bidder must not have Black listed by ESCOMS/other electrical utilities/who are in the business of distribution of power
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the preceding five years. A consistent history of awards involving litigation against the Bidder may result in rejection of bid.
An undertaking to source the supply of equipment/ material from KPTCL approved vendors only
Certificate is to be uploaded by the Bidder agreeing to source the equipment/material for the work from the approved vendors who meet the eligibility clauses regarding restrictions on procurement from a country which shares a land border with India as specified in Annexure XVIII of the tender documents
A Certificate is required to be uploaded by Bidder regarding restrictions on procurement from a Bidder of a country which shares a land border with India in the format as specified in the clause No.1.5 of Annexure XVIII of the tender documents
The Bidder should possess valid Super Grade Electrical Contractors License issued by the Government of Karnataka as on the date of Bid Submission
details of other works on hand and ongoing contractual commitments
The bidder should have valid GST registration with GSTIN number, PAN Card
No Deviation Certificate
Letter of Undertaking as in Annexure
valid labour license certificate issued by the Government of Karnataka
EPF and ESI registration Certificate
Self declaration regarding Risk & Cost
Filled Techno commercial sheet
Any other documents as per tender documents
Bidders shall submit audited financial reports for last five years preceding the date of bid submission duly certified by Registered Charted Accountant. Minimum Average Annual Turnover (MAAT) of the bidder for best three years out of last five financial years ending on March or December as the case may be, shall not be less than 1.5 Times of amount put to tender
₹500
₹33,380
20 Jul 2026
20 Jul 2026
5 Aug 2026
29 Jul 2026
Tender for increasing the Vertical clearance by providing 1no of 66KV D/C NBT DD plus 3 KPTCL design type intermediate tower between tower no 7 & 8 of 66kV Subramanyapura - Remco D/C line-2 near Arehalli limits, Gas godown road, in TLM Sub-Division Somanahalli, Bangalore
Supply of galvanised 66kV DC Transmission Line Towers.) 1. Normal Tower Type D (3.440MT)-01 Nos 2.3M Extension for DD(0.781)-01 No. 3.Stubs for D Type Tower (0.553 MT) -01 Nos
Supply of Bolts, Nuts and washers etc., (galvanised) required for 66KV DC Transmission Line Towers
Number Plates(Material - As per MWSR 2023-24 Page No : 43 Sl.No 19-19.2)(Labour - As per MWSR 2023-24 Page No : 113 Sl.No 3b)
Danger Boards(Material - As per MWSR 2023-24 Page No : 43 Sl.No 19-19.3)(Labour - As per MWSR 2023-24 Page No : 113 Sl.No 3a)
Phase plate (Set of 6 No.)(Material - As per MWSR 2023-24 Page No : 43 Sl.No 19-19.1)(Labour - As per MWSR 2023-24 Page No : 113 Sl.No 3c)
Circuit plates(Material - As per MWSR 2023-24 Page No : 43 Sl.No 19-19.2)(Labour - As per MWSR 2023-24 Page No : 113 Sl.No 3d)
Grounding of towers including cost of 40 mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 metres length as per specification with 50 X 6 mm GI Flats 3 metre long, salt, charcoal, including excavation cha...
Copper earth bond 450 mm(As per MWSR 2023-24 Page No : 43 Sl.No 19-19.4)
Coyote ACSR for Plain Terrian for 1span (3 runs), 4% of sag and 1% of cutting (As per MWSR 2023-24, page No.44, Sl.No 20, 20.6)
7/3.15 mm Ground wire (In plain terrain) (As per MWSR 2023-24, page No.44, Sl.No. 20, 20.7)
INSULATOR STRINGS WITH CLAMPS, ARCING HORNS AND HARDWARE for ACSR Coyote Conductor & DRAKE ACSR.:Single Tension string of 5 units of 120kN Disc Insulators each along with hard ware for Coyote ACSR an...
INSULATOR STRINGS WITH CLAMPS, ARCING HORNS AND HARDWARE for ACSR Coyote Conductor & DRAKE ACSR.:Single tension clamps suitable for Ground conductor. (As per MWSR-2023-24 Page No., Sl.No 46-46.1)
M S C Joints suitable for Coyote-Coyote ACSR (As per MWSR 2023-24 Page No : 67 Sl.No 46-46.6)
M S C Joints suitable for 7/3.15 mm Ground conducto(As per MWSR 2023-24 Page No : 67 Sl.No 46-46.6)
Repair sleeves suitable for Coyote ACSR(As per MWSR 2023-24 Page No : 67 Sl.No 46-46.8)
Repair sleeves suitable for 7/3.15 mm Ground conductor(As per MWSR 2023-24 Page No : 67 Sl.No 46-46.6)
C Wedge Conector for Coyote-Coyote ACSR(As per MWSR 2023-24 Page No : 70 Sl.No 47.10-47.10.4)
Vibration dampers for coyote (As per MWSR 2023-24 Page No : 67 Sl.No 46-46.9)
Check survey to be conducted during construction stage: Conducting detailed check survey along the approved route duly following the route alignment, GPS Co-ordinates, mission of detailed line schedul...
Supply of galvanised 66kV DC Transmission Line Towers
Assembling & Erection of towers incl tightening of bolts & nuts incl loading, unloading at store and site(incl weight of stubs)
Supply of Bolts, Nuts and washers etc., (galvanised) required for 66KV DC Transmission Line Towers
Note :- Rate to be quoted on per MT basis(Material - As per MWSR 2023-24 Page No : 43 Sl.No 18-18.3....
Setting of stub templates and aliging dismantling and transporation of templates from one location to another location(As per MWSR 2023-24 Page No : 113 Sl.No 1-1.1-b)
Sorting of Tower parts made of fabricated angle iron.
Welding of Bolt & nuts.(As per MWSR 2023-24 Page No : 113 Sl.No 1-1.1-e)
Revetting of tower Bolt ends by heating using dry-Acetylene gas and hammering to destroy threads so as to make the tower theft proof Bolts at nodal points only to be selected & revetted up to heigth o...
Supplying and fixing GI angle 450 x 450 mm 1Mtr length with cleats, bolts nuts as per specification and fixing above 0.5 mts length each at inner and outer surface of tower to facilitate running of b...
Supplying and fixing Barbed wire(As per MWSR 2023-24 Page No : 113 Sl.No 2b)
Number Plates(Material - As per MWSR 2023-24 Page No : 43 Sl.No 19-19.2)(Labour - As per MWSR 2023-24 Page No : 113 Sl.No 3b)
Danger Boards(Material - As per MWSR 2023-24 Page No : 43 Sl.No 19-19.3)(Labour - As per MWSR 2023-24 Page No : 113 Sl.No 3a)
Phase plate (Set of 6 No.)(Material - As per MWSR 2023-24 Page No : 43 Sl.No 19-19.1)(Labour - As per MWSR 2023-24 Page No : 113 Sl.No 3c)
Circuit plates(Material - As per MWSR 2023-24 Page No : 43 Sl.No 19-19.2)(Labour - As per MWSR 2023-24 Page No : 113 Sl.No 3d)
Grounding of towers including cost of 40 mm dia 2.5 mm thick, class 'C' G.I. Pipe of 3 metres length as per specification with 50 X 6 mm GI Flats 3 metre long, salt, charcoal, including excavation cha...
Releasing(for erecting the new tower) and Restringing(after erecting the new tower) a) Paving out conductor from anchor to anchor normally spaced at 5 spans with 4 tangent towers in between, including...
Releasing(for erecting the new tower) and Restringing(after erecting the new tower) b) Paving out 7/3.15 mm earthwire from anchor to anchor normally spaced at 5 spans with 4 tangent towers in between,...
Excavation for line tower foundation Normal soil (Updated rate as per KPWD SR 2023-24, Volume-1, pg No.5, item No.1.4.2 (Note: Cost of De-watering upto 10 % may be added , where required assess ment f...
Excavation for line tower foundation:Dry fissured/Ordinary rock (Updated rate as per KPWD SR 2023-24, Volume-1, pg No.6, item No.1.5.2 (Note: Cost of De-watering upto 7.5 % may be added , where requir...
Concreting and curing M20 (Updated rate as per KPWD SR 2023-24, Volume-1, pg No.15, item No.2.2.1
Concreting and curing 1 : 3 : 6 (Updated rate as per KPWD SR 2023-24, Volume-1, pg No.15, item No.2.1.4
Steel reinforcement (including material and labour) (Updated rate as per KPWD SR 2023-24, Volume-1, pg No.18, item No.2.11(h)
Back filling and levelling with available soil (Updated rate as per KPWD SR 2023-24, Volume-1, pg No.7, item No.1.9 (Note : 1. Add 5% per m3 for every additional 1.50m depth or part thereoff beyond 4...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Tender documents to upload.zip
Tender Document • 1.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].