Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.5 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹93.5 L+₹41.9 L (81.3%)Rejected-Finance | L2 | Rejected-Finance quoted rates higher than L1 bidder |
Tender Value
₹59.5 L
EMD Value
₹1.1 L
Closing Date
19 Oct 2022, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Repair maint of Transformers HT switche gears 2 or 4 or 6 pole structure HT infrastructure VCBs LT Panels and connected works at AF Stn Thanjavur
2022_MES_551903_1
CWE(AF)/TVM/82433 E8 repair HT at thanjavur
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Thanjavur
Class C category b(ii)
6 documents required · 6 mandatory
₹1,000
GE AF Thanjavur
₹1.1 L
Yes
1 Nov 2022
14 Sept 2022
21 Oct 2022
14 Sept 2022
19 Oct 2022
5 Oct 2022
14 Sept 2022 - 28 Sept 2022
Amount
SCHEDULE 'A'
Supply and lay cable HT, XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade (earthed cable) with stranded aluminium conductor of size 185 sqmm 3 core all as directed.
All as per Item No 2 here-in-before but 150 sqmm 3 core.
All as per Item No 2 here-in-before but 120 sqmm 3 core.
All as per Item No 2 here-in-before but 95 sqmm 3 core.
All as per Item No 2 here-in-before but 70 sqmm 3 core.
Supply and fixing/laying in replacement 100 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.
Supply and fixing/laying in replacement 80 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric laing in trench or pole / wall for protection of cable complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed. Note :- Mechanical excavation is not allowed in this Stn only manual excavation allowed.
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and exc. 1.5 metre but not exc 3 m in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.
Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite partricles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning.
Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed.
M & L for providing PCC (1:2:4) type B-1 with 20 mm graded aggregate as in, coping and finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M & L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set / Pole / feeder pillar lean concrete etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
Supply and erecting steel tubular pole complete with cast iron base plate, finial taper plug, nuts and screw as specified, type 410 SP-31, 9 Metre long including two coats of aluminium paint (PCC and earthwork in foundation shall be measured and paid under respective item separately) including dismantling of existing unserviceable pole including demolition of PCC work complete all as specified and as directed.
Supply and erecting steel tubular pole complete with cast iron base plate, finial taper plug, nuts and screw as specified, type 410 SP-55, 11 Metre long including two coats of aluminium paint (PCC and earthwork in foundation shall be measured and paid under respective item separately) including dismantling of existing unserviceable pole including demolition of PCC work complete all as specified and as directed.
S & F for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of two coats of aluminium paint over a coat of red oxide primer after and including dismantling old unserviceable cross arm etc complete all as specified and as directed.
S & F solid aluminium conductor of any size fixing and jointing on poles including, binding wires, jointing sleeves, aluminium tap and PG clamp etc after and including taking out old unserviceable ACSR complete all as specified and as directed.
M & L for under ground high tension cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed Note :- The rate quoted by the contractor shall include the rate for earth work and necessary T&P etc.
M & L for under ground low tension cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed Note :- The rate quoted by the contractor shall include the rate for earth work and necessary T&P etc.
M&L cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 50 to 95 Sqmm.
M&L cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 120 Sqmm to 185 Sqmm.
M&L cable jointing kit for 11 KV (earthed) grade cable for Straight through heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 120 Sqmm to 185 Sqmm.
M&L cable jointing kit for 11 KV (earthed) grade cable for Straight through heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 50 Sqmm to 95 Sqmm.
Supply and fix cable route indicator made out of 15x15x6mm GI plate welded with 8 mm x 45cm long GI rod grouted in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the words 'LT cable' as directed with synthetic enamel paint of two coats over a coat of primer including excavation and earth work all as directed.
Material and labour for painting to existing surfaces of HT/LT 11 mtr long steel tubular poles with 2 coats of aluminium paint over the existing surface including brackets clamps junction boxes etc including writing of pole number and painting to HT insulator RYB etc all as specified and as directed.
Material and labour Air break switch (GOD) Gang Operated Device horizontal / vertical type, tripple pole, mechanically operated, mounted on nine FRP insulators and steel frame, with operating mechanism worked from ground level, with operating rod 25mm dia light grade GI pipe, suitabel for current rating upto 200 Amps, HT 11 KV including taking out old unserviceable one and connecting up complete with locking arrangement all as directed .
Material and labour litening arrestors expulsion type complete with all fittings, transmission class discharge capacity 65 kilo amps suitable for 11000 volts complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Horn gap type Fuse unit 11000 Volts grade mounted on FRP insulators and steel frame, single pole, fixed on DP structure all specified and as directed.
Mateial and labour pin type, FRP insulator including one galvonised mild steel spindle, two galvonised iron washers and one galvonised iron nut, 150mm height, 150mm dia suitable for 11000 volts grade complete all as specified and as directed by Engr In Charge.
Dehydration including filtration of transformer oil on different locations by dehydration plant including testing of samples before and after dehydration and fiteration complete all as specified and directed the dielectric strength to be achieved 60 KV at 4 mm gap after complete dehydration.
M&L for cleaning of complete body of transformer of capacity 315/250/200 KVA and painting with two coat dark BS Gray painting & R, Y, B, Black, Green colour coding to insulators complete all as specified and directed
All as per item No 33 but 100/160 KVA
All as per item No 33 but 750/630 KVA
All as per item No 33 but 500/400 KVA
Material and labour for filling in with new transformer oil for top up having low viscosity of approved make as per IS 355 of 1992 and di-electric strength 60 KV(after filtration) complete all as specified and directed by Engineer-in-Charge.
Taking down old and UNSV transformer any capacity at different locations in the area of responsibility falls under GE (AF) Thanjavur from two pole strcture/ foundation including disconnecting the LT/HT connection and shifting to workshop and getting back after repair and refixing the same at original location and connecting electrically and commissioning complete all as specified and directed.
M&L Replacement of burnt defective HT/LT copper coil of different type capcity winding with superior qulity enamelled copper winding wire/strips of approved of suitable size/guage and Nos of turns maching with the existing impendence and insulated including all allied materials such as cork sheets, fiver glass insulation/paper insulation cotton, empire tape and wooden, bolts, nuts and washer (Brass) soldering and other packing material etc required for entire winding of coils all as specified and directed by Engineer- in-Charge.
M&L Replacement of HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity in repairs all as specified and directed by Engineer-in-Charge
M&L Replacement of LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity in repairs all as specified and directed by Engineer-in-Charge
M&L Top gasket sheet made out of 2 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity in repairs complete all as specified and directed
M&L Dehydrating breather assembly Aluminium/CI body of standard size filled with silica-gel for transformer of any capacity in repairs complete all as specified and directed
M&L Temperature gauge circular dia type of standard size for transformer of any capacity in repairs complete all as specified and directed
Annual maintanance including service and all checks as recommended by the manufacturer including opening and taking out unserviceable VCB panel units any capacity at different locations in the area of responsibility falls under GE (AF) Thanjavur, carried out repair work including cleaning, insulation value checking, applying lubricants to machanism and operational check up complete all as specified and directed.
Annual maintanance including service and all checks as recommended by the manufacturer including opening and taking out unserviceable VCB panel units any capacity at different locations in the area of responsibility falls under GE (AF) Thanjavur, carried out repair work including cleaning, insulation value checking, applying lubricants to machanism and operational check up complete all as specified and directed. Note for item No. 45 & 46 (i) The service of VCBs are to be carried out through authorised service engineer/ dealers. (ii) The duration of the service is once in three months throughout currency of the contract (iii) Periodical test report to be submitted through authorised service engineer/ dealer for every quaterly (iv) Report of quaterly inspection maintenance carried out by the contractor to be submitted on every inspection/ maintenance and after rectification of any breakdown (v) Contractor is liable for conducting inspection/ maintenance/ repair on call basis if required other than normal quaterly inspection. On call contractor is required to attend the complaint with in 24 hrs. if not attended the complaint with in 24 hrs contractor is liable to pay a penality Rs 1500/- per day (vi) Replacement of major spare parts as given in items here -in- after will be measured and paid seperately.
Supply and fix in replacement of numerical over current protection relay (2OC + 1 EF + 1 REF IDMTL and INST protection) digital type along with high set facility suitable for 11 KV HT VCB/RMU including provisioning blanking sheet to match the existing surface of the VCB.
Supply and fix in replacement resin cost current transformer 11 KV indor type of protection and metering of accuracy class 1, 5P-10 duel core of ratio 100/50/5 amps, 15 KVA burden complete all as specified and as directed.
Supply and fix in replacement potential transformer 11 KV 50 HZ, class 0.2, burden - 50VA fixed type 3 phase resin cast indoor type complete all as specified and as directed.
Supply and fix in replacement Tulip support 1250 amps Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Tulip complete (15 Fingure) 1250 amps Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Auxxillary relays/ contracts suitable for VCB complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement support insulator Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement close/trip coil 24 volt/30 volt/110 volt/220 volt DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement coil 24 volt/30 volt/110 volt/220 volt DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Motor assembly 110 volt / 220 volt AC/DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Micro switch with ball or without ball Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement anti pumping relay 110 volts AC/DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement TC Switches foe VCBs complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Indicatiom lamp suitable for VCBs complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement multimeter for VCBs complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Volt meter suitable for VCBs complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Ammeter suitable for VCBs complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement electronic hooters suitable for VCBs complete all as specified and as directed by Engr In Charge.
Supply and fix in replacement Bushes suitable for RMU complete all as specified and as directed by Engr In Charge.
Supply and fixing in replacement space heater suitable for VCB panel 100 watt 240 AC 50 HZ AC Supply complete all as specified and as directed.
Supply and fixing in replacement Thermostat 30 to 70 degree centigrade suitable for controlling space heater inside VCB panel 240 AC 50 HZ AC Supply complete all as specified and as directed.
Total of Schedule 'A'
EASHWAR ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .