Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC | ₹16.9 L Quoted ₹39.2 L | L1 | Accepted-AOC as per Aoc minutes |
| 2 | L1₹22.3 LAccepted-AOC | ₹22.3 L Quoted ₹39.2 L | L1 | Accepted-AOC as per Aoc minutes |
| 3 | Rejected-Technical | - | - | Rejected-Technical as per enclouser |
| 4 | Rejected-Technical | - | - | Rejected-Technical as per enclouser |
| 5 | Rejected-Technical | - | - | Rejected-Technical as per enclouser |
Tender Value
₹41.2 L
EMD Value
₹82,494
Closing Date
18 Jun 2024, 2:00 pmClosed
Superintending Engineer
Superintending Engineer Nagaon Circle Irrigation
Revival of Dakarghat Left LIS under SOPD_G for the year 2023_24 Package 3
2024_ID_37531_1
SEI/T-27/ET-1/2024-25/162
Open Tender
Civil Works - Others
Item Rate
90 days
Dakarghat
Please refer Tender documents.
3 documents required · 3 mandatory
₹850
₹82,494
Yes
13 Aug 2024
7 Jun 2024
18 Jun 2024
7 Jun 2024
18 Jun 2024
7 Jun 2024
Amount
Renovation of Existing Pump house
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.
Renovation of Existing SA Quarter
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal Wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. 35mm thk. shutter
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12 mm cement plastering including clearing surface and curing, complete as directed. i) In cement mortar 1:3
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) : 12.24.1 Natural colour insulating board 12.24.1.1 12 mm thick
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 9.3.2 Kiln seasoned and chemically treated hollock wood
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty. 14.5.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
Sanitary Part
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. each 146.30
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
Supplying, fitting, fixing PVC pipes (IS 12818, 6 kg/cm2 ), joining pipes with relevant cement, levelling, testing leakages etc, complete as directed. (Cost of E/W foundation trenches will be paid separately).
Supplying, fitting, fixing PVC equal tee joining with pipes with solvent cement testing leakages etc, complete as directed.
Supplying, fitting, fixing PVC bend pipe size joining with pipes with solvent cement, testing leakages etc, complete as directed.
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.
Internal & External water supply works
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
Supply of 1HP motor of Crompton/Usha/Kirloskar with necessary accessories as directed (Market rate)
Labour charge for fitting and fixing /installation of pump: Skilled labour(Plumber)
Labour charge for fitting and fixing /installation of pump: Semi Skilled labour
Construction of Toilet Block
Earthwork in excavation of foundation trenches including filling up sides of trenches and removal of spoils after completion of foundation, dressing, ramming, shoring etc. complete including bailing out water, where necessary, in ordinary soil.
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying, complete as directed.
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works, complete as directed. (Measurement to be taken on the face area timbered) i) Foundation, footing, base of columns, lie beam, pile cap, raft, walls of septic tank, inspection pit and the like upto plinth level.
RCC work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including curing etc. with necessary timber shuttering, scaffolding etc. where necessary, complete as directed. (Shuttering, scaffolding cost will be paid separately).
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc, including racking out joints and curing etc, complete as directed.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. 35mm thick shutter
Azar / Nahar / Nageswar / Zarul / Cham / Sundi / Gumi woodwork including supplying, fitting and fixing complete with necessary nut-bolts, nails, screws etc. and coaltaring 2 coats with coal tar applied hot as directed. (Rate is inclusive of required quantity of the tar). Undressed in floor planks collars, bracing standard wheel guard struts and railing, runner belts, rail post, tracking planks.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12 mm cement plastering including clearing surface and curing, complete as directed. A) In Prop. 1:3
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Internal Electrification
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Group A
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano typeswitch, connections, painting etc. as required
Supplying and fixing brass batten/ angle holder including connection etc. as required
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Construction of Staging for Water Tank
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mentioned in the approved drawing and complete as directed and specified.water, where necessary, in ordinary soil.
Soling in foundation and under floor including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing
C.C. work in prop. 1 : 4 : 8 in foundation /abutments / piers/ wing walls etc. with hard broken stone aggr. Of size 13 mm to 38 mm including curing, bailing out water if necessary as complete as directed. (Shuttering, scaffolding cost will be paid separately.)
Supplying, fitting, laying reinforcement (TATA) in position in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying, complete as directed.
RCC work in slab, abutment cap and above abutment, pier cap, pedestals, dirt wall etc in prop. 1 : 2 : 4 with hard broken stone aggregate of size 6 mm to 20 mm with proper reinforcement as per design including curing etc. with necy. timber shuttering, scaffolding etc. complete as directed. (Payment of reinforcement, shuttering, scaffolding will be made separately.)
Centering and shuttering including propping, etc and removal of forms after completion of CC and RCC works etc, complete as directed. (Measurement to betaken on the face area timbered).
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc, including racking out joints and curing etc, complete as directed.
12 mm cement plastering including clearing surface and curing, complete as directed. A) In Prop. 1:3
Construction of Boundary Wall
Earthwork in excavation trenches of walls, retaining walls, footing of columns, steps and septic tank including refilling (return filling) the quantity as necessary after completion of works, breaking clods in return filling, dressing, ramming, watering etc. and removal of surplus earth with all lead and lift upto 2 metre as directed and specified in following classification of soils, including bailing out of water where necessary upto depth below the existing ground level as mention in the approved drawing and as directed and specified.
Soling in foundation at all levels including filling intersides, ramming etc complete as directed and of specified thickness with 9 cm brick on flat including sand packing.
C.C work in proportion 1:3:6 in foundation / abutment / piers / wing walls etc.with hard broken stone agg. of size 13 mm to 38 mm including curing with necessary timber shuttering, scaffolding etc.where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
R.C.C work in slab, abutment cap and above abutment, pier cap, pedestal, dirt wall etc. in proportion 1:2:4 (M15) with hard river shingles of size 6mm to 20mm with proper reinforcement as per design including necessary curing etc. complete as directed with necessary timber shuttering, scaffolding etc. where necessary complete as directed. (Shuttering, scaffolding cost will be paid separately).
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). (C) Shuttering (Column)
Centering and shuttering including propping etc where necessary and removal of forms after completion of CC and RCC works as directed complete. (Measurement to be taken on the face area timbered). Shuttering (Beams) with out props
1st class brick work in cement mortar in abutment and wing wall, parapet wall etc.including racking out joints and curing etc. complete.
12 mm cement plastering including clearing surface and curing complete as directed. In proportion 1:4
Supplying fitting fixing and laying reinforcement (TATA) in position in RCC work including cutting, bending, cranking with two piles 0.91 M (20 BWG) annealed wire hooking tying complete as directed.
Chain link fabric fencing mesh of size 50x50 mm made of G.I. wire of dia 4 mm
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Repairing & overhauling of Electrical part: LT Cabling
Supply and Laying of 3½(Three and half) Core PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor in existing open trench/ in air including fixing with necessary clamps etc. in wall/ pole/ other support including End Termination with Brass Compression Gland and Cable Lug as n required and as directed . Size of Cable : 400 mm2 × 3.5 Core ( Single Line)
Supply and Laying of PVC/ XLPE Insulated Armoured LT Power Cable 1.1 kV Grade with Al Conductor of size 70 Sq mm x 3 corein single line, Conforming IS 7098(Part I) 1988, direct in ground including digging of trench of 0.3 Mtr wide × 0.75 Metre deep including Sand Cushioning (7.5 cm + 7.5 cm) and refilling alongwith fitting, fixing of Brass Compression Gland and Aluminium Cable Lug etc. as directed complete.
Repairing & overhauling of Electrical part:Repairing of Panel Board
Dismantling of Electricity accessories,cleaning and painting of Panel Board,
Supplying including fitting, fixing & connection of TPN Main Switch(SDFU-Switch Disconnector Fuse Unit) with HRC Fuses, 415VAC, Open Execution, Panel Mounting Type of following current rating sin already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed630Amps
Supplying including fitting, fixing & connection of TP (ThreePole) Main Switch (SDFU-Switch Disconnector Fuse Unit) with HRC Fuses, 415VAC, Open Execution, Panel Mounting Type of following curren tratingsin already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed, 200 Amps
Supplyingincludingfitting,fixing&connectionofTP(ThreePole)MainSwitch(SDFU-SwitchDisconnectorFuseUnit)withHRCFuses,415VAC,OpenExecution,PanelMountingTypeoffollowingcurrentratingsinalreadyfabricatedLTControlPanelBoard Housing along with Lugs, Connecting Cable andallothernecessarymaterialsforconnectionsasdirected 32A
Supplying including fitting, fixing & connection of 96 mm X 96 mm M I Voltmeter 0-500 Volt suitable for AC 50 Hz supply Accuracy Class I in already fabricated LT Control Panel Board Housing along with necessary connecting materials as directed.
Supplying including fitting, fixing & connection of 96 mm X 96 mm CT operated M I Ammeter suitable for AC 50 Hz supply, Accuracy Class I in already fabricated LT Control Panel Board Housing along with necessary connecting materials as directed.
Supplying including fitting, fixing & connection of On-Off Switch for Power Factor Meter suitable for AC 50 Hz supply in already fabricated LT Control Panel Board Housing along with necessary connecting materials as directed
Supplying including fitting, fixing & connection of Miniature Circuit Breaker(MCB) SP 250 V AC 50 Hz in already fabricated LT Control Panel Board Housing along with necessary connecting materials as directed
Supplying & Erection of Pipe Earth Station including supply of all materials with GI Pipe of following size perforated all over the body with 12mm dia hole at standad spacing with necessary reducing socket, locking arrangement with hinge coverplate, funnel GI Nuts&Bolts etc. with necessary enclosure on the top including excavation and refilling as required and as directed,40mm dia X 2.5 Metre
Supply & Erection of G.I.Earth Wire and Earthing of different Substation Items by connecting the existing Earth Pipes with G. I. Lugs as directed with 6 SWG G I Wire
Supplying including fitting, fixing & connection of Pilot Indicating Lamp Threaded, LED Type 25 mm in already fabricated LT Control Panel Board Housing along with necessary connecting materials as directed
Supplying including fitting, fixing & connection of On and off Push Button switch in already fabricated LT Control Panel Board Housing along with necessary connecting materials as directed.
Supplying including fitting, fixing & connection of Analog Power Factor Meter 0.5 lag - 1 - 0.5 lead in already fabricated LT Control Panel Board Housing along with necessary connecting materials as directed
Supplying including fitting, fixing & connection of Current Transformer(CT) for metering duty, Accuracy Class I, round type suitable for AC 50 Hz supply in already fabricated LT Control Panel Board Housing along with necessary connecting materials as directed, 600/5 & 200/5
Supplying including fitting & fixing of Copper Strip Busbar in already fabricated LT Control Panel Board Housing along with necessary fixing materials as directed
Supplying fitting fixing of LT Power Capacitor 415 Volt AC 3 φ (Single Unit) of following KVAR Rating and making connection with Busbar in the existing Panel. The Capacitor is to be placed in existing Platform, 20kVAR
Supplying including fitting, fixing & connection of Three Pole (TP) 415 V AC 50 Hz Air Break Contactor (ABC) of following current ratings in already fabricated LT Control Panel Board Housing along with Lugs, Connecting Cable and all other necessary materials for connections as directed
Procurement of New pumpset and Repairing & overhauling of Mechanical part
Rewinding & Repairing of Motor:Complete rewinding of 1(ONE) No 60 HP squirrel Cage induction Motor (Startor only)with enamolled copper wire of original Shape and Size after removing the damaged windings including heating ,varnishing, changing of Bearings, Terminal plate etc as required and reinstallation at site and testing at no load and then at full load as directed .Dismantling of motor ,Carrying to rewinding shop and then back to site after rewinding is under the scope of this work .Scrape to be retained by the contractor.
Repairing of Pumpset :Repairing and Complete over hauling of 60HP Pumpset after Dismantling .Cleaning & Greasing of Inside ,replacing of gland pressure plate ,DE & NDE bearing ,coupling nuts & bolts ,Rubber bushing ,impeller check Nut and other accessories where necessary .fitting of pump glanding &coupling with motor including successful trial run alongwith supply of all necessary Meterials as directed Complete.
Supply and Installation of Starter Oil Immersed :Supply & Installation of oil immersed manually operated auto Transformer Stater for 1(One)No 60 HP squirrel Cage induction Motor Including Construction of C.C Support 400mm*400mm*200mm in 1:2:4 ratio and M.S angle iron frame with 50mm*50mm*6mm angle along with dismantling of old unserviceable Starter and Fixing it with M.S nuts & bolts as directed
Repairing of 5 HP Motor of vacuum pumpset : Complete Rewinding of 1(one) 5 Hp vacuum motor (stator only) with enamalled copper wire of original shape and size after removing of damaged winding including healting varnishing and reinstallation at site at on load and then at full load.Dismantaling of motor,carrying to rewinding shop and then back to site after rewinding is under the scope of the work.
Repairing and complete over hauling of 5 Hp vacuum pumpset after dismantling, cleaning, greasing of inside, replacing of DE,NDE bearing of both pump & motor coupling nuts & bolts,Rubber Bushing and other accessories where necessary including pointing as directed complete
Supply,fitting,fixing of DOL starter for 5 Hp vacuum pumpset
Procurement of New Pumpset and fitting of Pumpsets along with other mechanical Components:Supply of Centrifugal pump set with 227 LPS minimum discharge at 13.10 Mtrs Head, working efficiently at head range 11 – 15.24 Mtrs coupled with 60 HP induction motor. Pump, Motor, Starter should be of reputed brand and as per IS Specification.
Installation of 20 H.P/60 HP Centrifugal Pump set (Horizontal Split casing type, squirrel cage induction motor of complete Pumpset. The job includes necessary transportation of pump set to the site and its installation on C.C. block foundation of Pump House in proper position with accurate alignment by means of foundation nuts and bolts including testing & commissioning at site at full load condition with all works complete as directed.
CIDF Reflex Valve: Heavy Duty CIDF Reflex Valve, swing check type, with by pass arrangement, horizontal operating. The holes of the flange to be as per BSS NO.-10, Part-I, Table D and the material, construction and all components should strictly conform to IS : 5312 (Part – I) - 2004 and having marked with manufacturer’s name and trade mark. Make: Kirloskar / Upadyaya / Zolato / Venus & Equivalent. Size 250 mm
Supply and installation of overhead tank along with stand: Fabrication and supply of M.S. tank of size 0.6Mtx0.6Mtx0.6Mt along with M.S. stand of 1.70Mt height comprising of 4 nos. columns fabricated from M.S. angle ISA 5050 with 3 nos. lateral bracing and frame fabricated from ISA 4040 followed by erection of the same with necessary C.C. base foundation with necessary support and clamping including. .
Miscelleneous Item:Supply of mascellanious items for operation of pumpsets including painting of pumpsets, suction & delivery pipes and accessories.
PADMA KANTA HAZARIKA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .