Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 LAdmitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L1 | Admitted-Finance | |
| 2 | L2₹3.7 L+₹12,163.44 (3.44%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹4.0 L+₹44,176.84 (12.5%)Admitted-Finance HOUSE NO 64 VILLAGE PALLA MASTER RISHAL SINGH WALI GALI DELHI NORTH WEST DELHI DELHI 110036 | NORTH DELHI | DELHI | 110036 | L3 | Admitted-Finance | |
| 4 | L4₹4.4 L+₹86,496.36 (24.5%)Admitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company L1 | N.K. BUILDCOM L3 | Shakti Trading Co. L2 | MITTAL TRADING COMPANY L4 |
|---|---|---|---|---|---|---|---|
| 1.01 | Molded Case Circuit breaker of 100 ampere rating. Breaking Capacity30 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Provision of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.21Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B | 15 | Nos. | 67,200 ₹79,296 | 1,05,000 ₹1,23,900 | 64,125 ₹75,667.5 Lowest | 89,985 ₹1,06,182.3 |
| 1.02 | Molded Case Circuit breaker of 125 ampere rating. Breaking Capacity 36 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Provision of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.22Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B | 5 | Nos. | 43,100 ₹50,858 | 40,000 ₹47,200 | 22,650 ₹26,727 Lowest | 32,495 ₹38,344.1 |
| 1.03 | Molded Case Circuit breaker of 200 ampere rating. Breaking Capacity36 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Proviion of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.23 Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B | 5 | Nos. | 49,850 ₹58,823 | 50,000 ₹59,000 | 42,725 ₹50,415.5 Lowest | 56,995 ₹67,254.1 |
| 1.04 | Molded Case Circuit breaker of 250 ampere rating. Breaking Capacity36 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Provision of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.24 Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B | 6 | Nos. | 65,262 ₹77,009.16 | 72,000 ₹84,960 | 59,070 ₹69,702.6 Lowest | 86,394 ₹1,01,944.92 |
| 1.05 | Molded Case Circuit breaker of 400 ampere rating. Breaking Capacity50 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Provision of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.26Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B | 5 | Nos. | 74,150 ₹87,497 | 70,000 ₹82,600 Lowest | 1,21,300 ₹1,43,134 | 1,06,995 ₹1,26,254.1 |
Tender Value
Refer Docs
EMD Value
₹9,700
Closing Date
18 Feb 2026, 11:15 amClosed
EE ENM M VII
DELHI JAL BOARD MU BLOCK PITAMPURA-34
Procurement of different rating MCCBs for Pitampura and Shalimar bagh area in AC 14
2026_DJB_286666_8
NIT No. 32(2025-26)M-VII
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M VII
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹9,700
Yes
23 Feb 2026
11 Feb 2026
18 Feb 2026
11 Feb 2026
18 Feb 2026
11 Feb 2026
Molded Case Circuit breaker of 100 ampere rating. Breaking Capacity30 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Provision of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.21Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B
Molded Case Circuit breaker of 125 ampere rating. Breaking Capacity 36 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Provision of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.22Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B
Molded Case Circuit breaker of 200 ampere rating. Breaking Capacity36 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Proviion of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.23 Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B
Molded Case Circuit breaker of 250 ampere rating. Breaking Capacity36 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Provision of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.24 Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B
Molded Case Circuit breaker of 400 ampere rating. Breaking Capacity50 KA, Ics 100% Icu, Suitable for isolation, conforms to IS/IEC 60947-2 & IEC 60947-2, Provision of thermal memory, Front LED indicator, Manual, rotary or motorized version at 415V Four pole thermal magnetic trip unit. SOR 43.6.26Make :- Siemens/ L&T/ Schneider / C&S and any other make approved by D J B
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.53 MB
BOQ_379553.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .