Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹96.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹1.0 Cr+₹8.8 L (9.16%)Rejected-Finance NO 3 MAIN STREET 1ST CROSS JEEVA RUKMANI NAGAR PAKKAMUDAYANPET PUDUCHERRY 605 008 | PUDUCHERRY | PUDUCHERRY | PUDUCHERRY | 605008 | L2 | Rejected-Finance M/S. MS Constructions is a second lowest tenderer. Hence Rejected | |
| 3 | L3₹1.1 Cr+₹10.9 L (11.3%)Rejected-Finance NO 34 OUDAYAR STREET PAKKAMUDAYANPET PUDUCHERRY 8 | PONDICHERRY | PUDUCHERRY | 605001 | L3 | Rejected-Finance K Ramadass is a third lowest tenderer. Hence Rejected |
Tender Value
₹91.5 L
EMD Value
₹1.8 L
Closing Date
29 Feb 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, PHD, PWD, Puducherry
Executive Engineer, PHD, PWD, Puducherry
Construction of additional collection well at Kanaganeri STP campus along with interlinking of existing gravity trunk sewer line on western side of Kanaganeri Road, Reddiarpalayam, Puducherry
2024_PWDC2_15506_1
54/PHD/2023-24/02
Open Tender
Civil Works - Water Works
Item Rate
150 days
Uppalam
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,050
₹1.8 L
16 Mar 2024
23 Feb 2024
1 Mar 2024
23 Feb 2024
29 Feb 2024
23 Feb 2024
Amount
Earthwork in excacavation over areas (exceeding 30 cm in depth , 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth lead upto 50m and lift upto 1.5m - disposed earth to be levelled and neatly dresses - all kinds of soil
Sinking well of 6 metre internal dia below water level including all incidental charges such as bailing and pumping of water, using special tools and plants etc., complete in ordinary soil,loose soil,sandy soil and clay soil. – For first depth of 2m.
Sinking well of 6 metre internal dia below water level including all incidental charges such as bailing and pumping of water, using special tools and plants etc.,complete in ordinary soil,loose soil,sandy soil and clay soil. – For second depth of 2m.
Sinking well of 6 metre internal dia below water level including all incidental charges such as bailing and pumping of water,using special tools and plants etc.,complete in ordinary soil,loose soil,sandy soil and clay soil. – For third depth of 2m.
Sinking well of 6 metre internal dia below water level including all incidental charges such as bailing and pumping of water,using special tools and plants etc.,complete in ordinary soil,loose soil,sandy soil and clay soil. – For fourth depth of 2m.
Sinking well of 6 metre internal dia below water level including all incidental charges such as bailing and pumping of water,using special tools and plants etc.,complete in ordinary soil,loose soil,sandy soil and clay soil. – For fifth depth of 2m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Centering and shuttering including strutting , propping etc and removal of form for - Walls (any thickness ) including attached pilasters , butteresses , plinth and string courses etc.
Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe-415 or more.
Steel work welded in built up sections / framed work , including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
Extra for laying concrete in or under water and /or liquid mud including cost of pumping or bailing out water and removing slush etc. complete (Note: The quantity will be calculated by multiplying the depth measured from the subsoil water level upto centre of gravity of concrete under sub soil water level with quantity of concrete in cum executed under the sub-soil water. The depth of centre of gravity shall be reconed correct to 0.10 m ,0.05 m or more shall be taken as 0.10 m and less than 0.05 m ignored.
Extra for laying concrete in or under foul positions
Fixing of 150 mm wide PVC encapsulated steps in the manholes with 200 x 200 x 100 mm CC block in cement concrete 1:1.5:3 (one cement ,one and half sand and three hard broken granite stone aggregate of 20 mm nominal size) all as shown in drawings.
Earth work excavation above water level and depositing on bank in sandy, silt or other soil, wet sand or silt, light black cotton soil or clay, sandy loam and ordinary soil for infiltration, gallery siphon or connecting pipe line including driving shoring materials as mentioned below. Removing the shoring materials and refilling with excavated earth complying with standard specification etc., complete. - First depth of 2m (using close timbering)
Earth work excavation below water level and depositing on bank in sandy,silt or other soil, wet sand or silt, light black cotton soil or clay, sandy loam and ordinary soil for I.Cs, manhole, well, infiltration well, suction well,siphon or connecting pipe line including driving shoring materials etc,. for excavation purpose and removing the shoring materials and pumping out water caused by spring or tidal or river seepage using diesel engine and refilling with excavated earth complying with standard specification etc. complete. – For first depth of 2 metre (using close timbering).
Earth work excavation below water level and depositing on bank in sandy silt or other soil, wet sand or silt, light black cotton soil or clay, sandy loam and ordinary soil for I.Cs, manhole, well, infiltration well, suction well,siphon or connecting pipe line including driving shoring materials etc, for excavation purpose and removing the shoring materials and pumping out water caused by spring or tidal or river seepage using diesel engine and refilling with excavated earth complying with standard specification etc. complete. - For second depth of 2 metre (using close timbering).
Earth work excavation below water level and depositing on bank in sandy silt or other soil, wet sand or silt, light black cotton soil or clay, sandy loam and ordinary soil for I.Cs, manhole, well, infiltration well, suction well,siphon or connecting pipe line including driving shoring materials etc, for excavation purpose and removing the shoring materials and pumping out water caused by spring or tidal or river seepage using diesel engine and refilling with excavated earth complying with standard specification etc. complete.– For third depth of 2 metre (using close timbering).
Providing and laying Ductile Iron socket and spigot pipes of class K7 (Electro steel/Sripipes/Jindal/Electrotherm / Jai Balaji / TATA Metaliks Kubota) conforming to IS specification 8329/2000 and ISI marked suitable for tyton /push on joints in good condition including transportation of D.I.pipe from production centre/company to the site at UT of Puducherry, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment etc.,complete all as per IS 12288 and CPWD specification. (earth work and jointing of pipes with rubber gasket will be paid separately) -700mm dia.
Providing and jointing cast iron / D.I. (S&S) pipe joints with rubber gasket (Tyton joints) conforming to IS 5382 & 12820 of SBR quality including the cost of fixing,testing the joints etc.,complete -700mm dia.
Labour for cutting C.I. pipe with steel saw:- 600mm diameter C.I. pipe.
Making connection between existing two Drainage wells with 600mm dia CI / DI pipe at below ground level upto 8.00M depth including the cost of dismantling of concrete wall for a size of 120cm dia hole and 70cm wall thickness. Dismantling of brickwork well to the size of 120cm dia hole and 50cm wall thickness. The 600mmdia D.I. pipe one end fixing in position to the concrete well with cement concrete 1:1.5:3 mix and another end of pipe fixing in position to the brickwork well with cement concrete 1:1.5:3 and finishing the surfaces with cement plaster to the both ends.
Providing erecting and commissioning of the special dewatering system arrangements for the purpose of dewatering the heavy ground water infiltration from the trenches of the Trunk Sewer line/ collection well. The cost includes hire charges for dewatering system including boreholes alround the trunk manholes/collection well, delivery arrangements for pumped out water into the nearby main drain 65 HP vaccum pump. 65HP jetting pump required nos. of borewell point of 40mm dia and 5.5m depth. The cost also includes hire charges for ranging from 100 KVA to 150 KVA. Diesel Generator set to supply electricity for the deatering unit for continuous operation round the clock for dewatering the heavy ground water infiltration. The cost also includes transportation of Diesel Generator set, erection, commissioning cost of Diesel cost of operator for operating the dewatering unit nad generator set and watch and ward etc., complete all as directed by the Engineer-in-charge
M Selvam
K Ramadass
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .