Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹10.3 L+₹78,534 (8.23%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹12.8 L+₹3.3 L (34.5%)Rejected-Finance BLOCK NO 6 7 WING NO 3 RAHUL COMPLEX I ST BUS STAND GANESHPETH GANESHPETH NAGPUR NAGPUR MAHARASHTRA 440018 | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-Finance Not lowest |
Tender Value
₹14.3 L
EMD Value
₹28,640
Closing Date
4 Jun 2020, 6:00 pmClosed
GE (AF) Nagpur
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPLACEMENT AGAINST UNSERVICEABLE BER ACs AT VSN NAGPUR
2020_MES_337957_1
GE/NAG/20-21/8360/8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Nagpur
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE (AF) NAGPUR
₹28,640
Yes
17 Jun 2020
8 Apr 2020
5 Jun 2020
8 Apr 2020
4 Jun 2020
22 Apr 2020
Amount
M & L for sub main wiring (concealed/Surface) complete with two single core 4 Sqmm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC heavy duty conduit and conduit accessories including 4 Sqmm FR PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed by EIC. Note: 3 run of 4 sqmm & one run of PVC conduit shall be measured as single unit. Make of cable : Plaza, Polycab, Finolex. Note: The disturbed surface of wall for surfacce box wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces. The rate for point wiring shall be deemed to include the costof making good Make: Make of modular box and plaate is legrand.
Supply and install invertor based split AC of capacity 1.5 TON ,(Copper coil) electric driven single phase, 230 volts, New 3 star rating including all accessories like brackets, rubber tubing, copper tubing, gas charging, etc including testing and commissionin with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as directed Make Hitachi/LG/Blue star/Godrej/'O' General/Vlotas Note :- All cooing /condensing coil should be copper matrial
Supply and install Voltage stablizer automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stablized at 230 Volt with accuracy of (+/-)2.5 percent of capacity 4KVA. Make: V guard, Steady Volt, Microtek
Supply and fix new copper tubes of size 1/4 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and as directed.
Supply and fix new copper tubes of size 5/8 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and as directed.
S & F power unit for upto 2 ton AC and geyser up to 2 KW modular type, 4 module, 240 volts complete all as specified and as directed. Make : Legrand Cat No. 675558 equivalent in Acchor roma, Crabtree.
Supply and fix PVC rigid conduit pipe 20/25 mm dia including all accessories and necessary saddles with fixing screwa, gutties etc.for drain out water complete all as specified and as directed.
Supply and fix flexible U-PVC trunking of size 105x50 mm duly fixed on wall/floor complete all as specified and as directed.
Supply and fix split AC stand as per OEM recommendation of outdoor unit suitable for 1.5/2 ton including necessary fixing arrangement complete all as specified and as directed.
Material and labour for making temporary shade size 01mx01mx01 mtr using GI sheet 0.6 mm thick with nuts , bolts, washer angles iron size 25x25x3mm thick for supporting of shade to above room/pourc with two coat of synthetic enanel paint on surface of angles and sheet with suitable arrangement of PCC 1:3:6 work for shade work complete all as specified and as directed. Note: - The contractor should attend the complaint and rectify the defect within 05 days (Maximum) failing which Rs Rs @500.00 per day per AC (Split/window 1.5/2 TR)/ Water Cooler/Refrigeratior will be recovered from the RAR/Final during warranty period.
Shri Sai Enterprises
Advance Refrigeration Engineering Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .