Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.1 LAdmitted-Finance | ₹75.1 L | L1 | Admitted-Finance |
| 2 | L2₹79.4 L+₹4.4 L (5.79%)Admitted-Finance | ₹79.4 L+₹4.4 L (5.79%) | L2 | Admitted-Finance |
| 3 | L3₹79.7 L+₹4.7 L (6.21%)Admitted-Finance HIMACHAL BUILDING SHOP NO 10 CD BARFYWALA ROAD JUHU LANE ANDHERI W MUMBAI 400058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹79.7 L+₹4.7 L (6.21%) | L3 | Admitted-Finance |
| 4 | L4₹80.2 L+₹5.2 L (6.88%)Admitted-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹80.2 L+₹5.2 L (6.88%) | L4 | Admitted-Finance |
| 5 | L5₹81.5 L+₹6.4 L (8.50%)Admitted-Finance PLOT NO D 2 COAL DEPOT FOSBERY ROAD SEWRI E MUMBAI 400 015 | MUMBAI | MUMBAI | MAHARASHTRA | 400015 | ₹81.5 L+₹6.4 L (8.50%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Har Siddhi Buildcon L1 | M.K Enterprises L4 | LAXMI ENTERPRISES L2 | M/s PIONEER CONTRACTORS L3 | M/S Royal Enterprises L6 | K A ELECTRIC CO L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for carrying out repairs to AMF panel of 15 KVA to 200 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measured and paid seperately under relevant items. | 8 | Job | 3,200 ₹25,600 | 3,011 ₹24,088 | 2,998 ₹23,984 | 3,006 ₹24,048 | 2,950 ₹23,600 Lowest | 3,023 ₹24,184 |
| 2.00 | Material and Labour for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : | 1 | Each | 4,61,200 ₹4,61,200 Lowest | 4,80,004 ₹4,80,004 | 4,79,996 ₹4,79,996 | 4,79,992 ₹4,79,992 | 5,30,000 ₹5,30,000 | 4,80,026 ₹4,80,026 |
| 2.01(A) INCOMING - (i) On-load Changeover Switch I-O-II open execution, 4 pole - 630 Amps, - 01 No (ii) MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No. | |||||||||
| 2.02(B) OUTGOING- (i) MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250 Amps – 01 No. (ii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 160 Amps – 01 No. (iii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 125 Amps – 02 No. (iv) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 100 Amps – 06 No. (v) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No. (vi) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (vii) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (viii) Aluminium bus bar of Rating 2000 Amp R-Y-B phases and Neutral. (ix) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (x) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. | |||||||||
| 3.00 | Material and Labour for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : | 1 | Each Job | 3,86,650 ₹3,86,650 Lowest | 4,10,017 ₹4,10,017 | 4,09,997 ₹4,09,997 | 4,10,006 ₹4,10,006 | 4,50,000 ₹4,50,000 | 4,10,039 ₹4,10,039 |
| 3.01(A) INCOMING - i) On-load Changeover Switch I-O-II open execution, 4 pole - 630 Amps, - 01 No (ii) MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No. | |||||||||
| 3.02(B) OUTGOING- (i) MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250 Amps – 01 No. (ii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 100 Amps – 07 No. (iii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 63 Amps – 02 No. (iv) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No (v) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1. (vi) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each, (vii) Aluminium bus bar of Rating 1000 Amp R-Y-B phases and Neutral. (viii) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted. (ix) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. | |||||||||
| 4.00Supply & Fixing,Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes incl taking out cable all as specified and directed | |||||||||
| 4.01 | 3.5 core 70 Sqmm | 800 | RM | 475 ₹3,80,000 | 475 ₹3,80,000 | 453 ₹3,62,400 | 464 ₹3,71,200 | 450 ₹3,60,000 Lowest | 496 ₹3,96,800 |
| 4.02 | 3.5 core 185 Sqmm | 951 | RM | 1,000 ₹9,51,000 | 957 ₹9,10,107 | 946 ₹8,99,646 | 945 ₹8,98,695 | 940 ₹8,93,940 Lowest | 980 ₹9,31,980 |
Tender Value
₹84.6 L
EMD Value
₹1.5 L
Closing Date
15 Aug 2026, 6:00 pmClosed
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN NAVI MUMBAI RAIGAD - 400704
CERTAIN CIVIL WORKS OF REPAIR MAINT NATURE FOR DG SETS CABLE TRENCHES DUCT TRENCH COVERS SERVICING PAINTING TO SHUTTERS ETC INCLUDING E M WORKS LIKE REPAIR REPLACEMENT OF ATS SWITCHGEARS EARTHING CANOPY ETC AT NAVAL STATION KARANJA
2026_MES_779510_1
84575-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAVAL STATION KARANJA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) KARANJA
₹1.5 L
16 Sept 2026
18 Jul 2026
18 Aug 2026
18 Jul 2026
15 Aug 2026
8 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for carrying out repairs to AMF panel of 15 KVA to 200 KVA DG set at various installation inclduing study, tracing out circuit, testing, replacing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioning complete all as specified and as directed. (Note: Spares like Volt meter, CT, power contactor required for repair will be measured and paid seperately under relevant items. | 8 | Job | - | - |
| 2 | Material and Labour for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : | 1 | Each | - | - |
| 2.01 | (A) INCOMING -
(i) On-load Changeover Switch I-O-II open execution, 4 pole - 630 Amps, - 01 No
(ii) MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No. | - | - | - | - |
| 2.02 | (B) OUTGOING-
(i) MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.
(ii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 160 Amps – 01 No.
(iii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 125 Amps – 02 No.
(iv) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 100 Amps – 06 No.
(v) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No.
(vi) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1.
(vii) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each,
(viii) Aluminium bus bar of Rating 2000 Amp R-Y-B phases and Neutral.
(ix) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.
(x) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. | - | - | - | - |
| 3 | Material and Labour for dismantling of existing panel including disconnecting connected cables, etc. and supplying, installing, testing and commissioning of factory made LT cubical double door panel with roof canopy, outdoor type, of Suitable to accomodate the following accessories made out of CRCA sheet 3 MM thick duly powder coated with Seimens Grey Shade RAL 7032, totally enclosed, dust and vermin proof outer cubicle. Inner cubicle should be made out of 2 MM thick CRCA sheet with working voltage of 415V, 50 Hz, 3 phase 4 wire fully compartmentalised with single door system for each compartment. Outer cubicle having both sides door openable and should be provided with suitable louvers for ventilation. Bus bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The bus bar connections and their insulated supports shall be mechanically strong, and shall withstand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuation in temp., shot-circuit or other causes. The bus bar should be supported on DMC. Provision shall be made for expansion and contraction of the bus bars and connections with variation of temp. Internal wiring should be done with 2.5 sqmm multi-stranded copper conductors and shall be properly bunched, tied, ferruled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves, etc. The bottom of the panel should contain detachable plate having provision for entry of armoured cable of adequate size with glands. Threaded earthing studs - 02 Nos shall be provided at the bottom and lifting lugs of suitable size at top to lift the panel safely shall be made. The cubicle incomer MCCB as well as outgoings shall have copper TPN/TP extension links of current rating not less than 1.5 times the rated capacity of individual feeders with Ics = 100% Icu in all MCCBs with extended Rotary Handle. The cubicle should be inclusive of following : The cubicle should be inclusive of following : | 1 | Each Job | - | - |
| 3.01 | (A) INCOMING -
i) On-load Changeover Switch I-O-II open execution, 4 pole - 630 Amps, - 01 No
(ii) MCCB -DPX3 630 thermal & magnetic type 4 pole 415 volt 36 kA breaking cap. adjustable thermal release range 630 Amps – 01 No. | - | - | - | - |
| 3.02 | (B) OUTGOING-
(i) MCCB -DPX3 250 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 250 Amps – 01 No.
(ii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 100 Amps – 07 No.
(iii) MCCB -DPX3 160 thermal & magnetic type 4 pole 415 volt 25 kA breaking cap. adjustable thermal release range 63 Amps – 02 No.
(iv) Multi function meter having LCD Display, 96 x 96 sq.mm -01 No
(v) Current transformer of suitable ratio, Accuracy - 5VA, Class - 1.
(vi) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Each,
(vii) Aluminium bus bar of Rating 1000 Amp R-Y-B phases and Neutral.
(viii) Base frame for cubical mounting made out of 40x40x6mm equal angle iron duly painted.
(ix) Foundation for the panel should provided with PCC 1:4:6 at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables. | - | - | - | - |
| 4Supply & Fixing,Laying, jointing, connecting & testing XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of following sizes incl taking out cable all as specified and directed | |||||
| 4.01 | 3.5 core 70 Sqmm | 800 | RM | - | - |
| 4.02 | 3.5 core 185 Sqmm | 951 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
tenderpages575.pdf
Tender Documents • 1.63 MB
SOC575.pdf
Additional Documents • 0.19 MB
BOQ_873111.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .