Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹116.2 CrAccepted-AOC | ₹116.2 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹119.6 CrRejected-AOC THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹119.6 Cr | L2 | Rejected-AOC Accepted |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹111.2 Cr
EMD Value
₹55.6 L
Closing Date
21 Feb 2024, 6:55 pmClosed
Executive Engineer P.W.D. Ambajogai
Executive Engineer P.W.D. Ambajogai
Construction of Class-III and Class-IV Quarters at S.R.T.R. Medical College Ambajogai Tq. Ambajogai
2024_PWR_988123_1
Ambajogai_PWD_B_2_25_2023_24
Open Tender
Civil Works
549 days
Ambajogai
Pls refer tender document.
2 documents required · 2 mandatory
₹11,800
₹55.6 L
Chief Engineer, P.W.Region Ch. Sambhajinagar
30 Mar 2024
22 Jan 2024
23 Feb 2024
22 Jan 2024
21 Feb 2024
22 Jan 2024
7 Feb 2024
Amount
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material with all lead & lift beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. (Lift upto 1.5 metre) By Mechanical Means
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 Metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. By Mechanical Means
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 Metre, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. By Mechanical Means
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 Metre, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etcetera complete. By Mechanical Means
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 Metre beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etcetera complete. By Mechanical Means
Filling in plinth and floors with approved excavated material in 15 centi metre. to 20 centi metre layers including watering and compacting etcetera complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 centi metre to 20 centi metre including watering and compaction etcetera complete.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Providing soling using 80 mili metre size trap metal in 15 centi metre layer including filling voids with Crushed sand/grit, ramming, watering etcetera complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying in situ cement concrete M-30 with tremix treatment for 200 mili metre thickness for flooring with groove cutting of 4 mili metre wide and 20 mili metre deep with necessary refilling with bitumen etcetera complete.
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etcetera complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetera including bailing out water, Steel centering, formwork ,cover blocks, laying/ pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etcetera complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/ pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/ pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etcetera) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing in position Thermo Mechanical Treated (TMT) - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etcetera as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etcetera as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etcetera and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etcetera complete.
A] Parking Floor
G] Sixth Floor
I] Terrace Floor
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in Cement Mortor 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etcetera complete.
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etcetera Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etcetera Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi - viscous paste prepared by mixing polymer of approved make chemical and Cement in 1:2 proportion (1 litre polymer : 2 Kg Cement)or Rohnex water proofing system in two coats(1kg powder,700 ml water and polymer jelly for first coat & 1 kg powder,500 ml water & polymer jelly for second coat) to a neatly cleaned and dust free concrete surface and upto 300 mm over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 x 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, laying mechanical protective cover to polymer coating treatment with brick bat coba with burnt broken brick bats laid in C.M. 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer, joints of Brick Bats with C.M. 1:3 admixed with approved water proofing compound and finally top finishing with average 20mm thick layer of same mortar added with polypropylene fibers at 125 gm per bag of cement including finishing the surface smooth with neat cement slurry admixed with approved water proofing compond, Marking finished surface by false squares of 300 mm x 300 mm, Making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and prapet and curing and covering 10 years Guarantee against leakproofness on court fee stamp paper Rs. 100/- including ponding test etc. complete
A] Parking Floor
C] Second Floor
G] Sixth Floor
H] Seventh Floor
Providing water proof bedding for flooring of Bath and Water Closet 25 mili metre thick in Cement Mortor 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etcetera washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge.
A] Parking Floor
C] Second Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 20 to 25 mili metre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mili metre depth, filling the joints with 6 mili metre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etcetera complete. (excluding Cement concrete 1:3:6 base concrete )
Providing and fixing 20 to 25 mili metre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mili metre between rough shahabad and Reinforced Cement Concrete walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mili metre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etcetera complete. (excluding Cement concrete 1:3:6 base concrete)
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 mili metre thickness to previously plastered surface / or on newly brick surface (Excluding rough cast plaster) in all position including preparing and Finishing the surface scaffolding etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing internal cement plaster 12 mili metre thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mili metre thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mili metre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing fine cement finish 1.5 mili metre thick over green plaster surface including scaffolding curing etcetera complete.
A] Parking Floor
G] Sixth Floor
H] Seventh Floor
Providing patti/ band 75 mili metre wide on plastered surface 12 mili metre to 15 mili metre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing patti/ band 100 mili metre wide on plastered surface 12 mili metre to 15 mili metre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing patti/ band 150 mili metre wide on plastered surface 12 mili metre to 15 mili metre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centi metre width at the junction of Reinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /Burnt Brick Masonry and or tying by binding wire etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595 mili metre x 595 mili metre having 15 mili metre thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600 mili metre made from hot dipped Galvanised Iron steel sections ion silhouette profile, rotary stitched double webbed white with 6 mili metre reveal profile (white/black), wherein, main T runner of size 42 mili metrex14 mili metre between main tee 600 mili metre center-tocenter and secondary cross T of size 33x14x0.43 mili metre thick of length 600 mili metre long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200 mili metrex600 mili metre resting on periphery wall Profile wall section 19 mili metre (7+7) x 19 mili metrex0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures,, smoke detectors etcetera, wherever required. Main T runners suspended from ceiling with using Galvanised Iron soffit cleats of size 25x35x1.6 mili metre of required length fixed to the ceiling with 6 mili metre diametre and 50 mili metre long dash fastener, 4 mili metre diametre Galvanised Iron adjustable rods with powder-coated/good quality Galvanised Iron level adjustment clips of 35x35x0.8mm spaced @1200, center-to-center along main T all complete at all heights as per the specifications, drawings and as per the directions of Engineer-in-charge.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and Reinforced Cement Concrete beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mili metre to 605 mili metre x 590 mili metre to 605 mili metre of 8 to 10 mili metre thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mili metre to 605 mili metre x 590 mili metre to 605 mili metre of 8 to 10 mili metre thickness and confirming to Indian Standard 15622-2006 ( group Bla) of approved make, shade and pattern for dado & skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mili metre thickness of having a strength of 300 Kilogram/Square Centi Metre of approved quality and shape on a bed of crushed sand of 25 to 30 mili metre thick including skirting joints and cleaning etcetera complete
Providing and laying ceramic tiles having size 30 centi metre x 60 centi metre confirming to corresponding Indian Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centi metre x 30 centi metre and Confirming to Indian Standard 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying machine cut machine Polished Kota stone flooring 25 mili metre to 30 mili metre thick and required width in plain/ diamond pattern on bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etcetera complete. For Flooring
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing machine cut machine polished 18 mili metre to 20 mili metre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying in position flooring of telephone black granite stone of approved shade and size 18 mili metre to 20 mili metre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etcetera complete.
Providing and laying telephone black granite stone of 18 to 20 mili metre thick for door frame/ dado/ window boxing etcetera On Cement Mortor 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mili metre x 450 mili metre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mili metre thick supports with kadappah top 35 to 40 mili metre thick and polished granite 16 to 20 mili metre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centi metre height and top granite of 75 x 40 centi metre including cutting, opening for sink of required size in kadappah as well as granite etcetera complete. (Platform top size 5.00 metre x 0.60 metre and height is 0.75 m)
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mili Mild Steeltainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 Kilogram load bearing capacity of trolley made out of 20 mili metrePUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mili Mild Steels. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1 mili metre Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 centi metre Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5 mili metre The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etcetera complete, as directed by Engineer in charge.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 34 mili metre thick moulded door shutter consisting of solid core single leaf flush door of 30 mili metre thickness lipped with 15 mili metre( 5 mili metre x 3) thick x 30 mili metre width on one style and top rail and 10 mili metre(5 mili metre x 2) thick x 30 mili metre width on other style and bottom rails. The inner panels laminated with 2 mili metre thick termite proof, water proof and fire resistant moulded Polyvenyle Chloride sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mili metreplain and /or pre lam Polyvenyle Chloride on other side using rubber adhesive on flush door and solvent cement adhesive on the Polyvenyle Chloride lipping etcetera as per direction of Engineer in charge and manufacturers specification and drawing etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mili metre x 1.22 mili metre box type, 5 mili metre thick sheet glass louvers, of approved quality etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and Fixing 30 mili metre thick BOTH SIDE PRELAMINATED SOLID PANEL Polyvenyle Chloride DOOR SHUTTER consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 mili metre for styles and 15 x15 mili metre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Polyvenyle Chloride 'C' channel made from 5 mili metre(+/0.25) thick prelaminated sheet of density 600 Kilogram/cbm ,of size 30 mili metre thickness 70 mili metre width out of which 50 mili metre shall be flat and 20 mili metre shall be tapered in 45 angle on either side forming stiles ; and 5 mili metre thick ,95 mili metre wide Polyvenyle Chloride sheet out of which 75 mili metre shall be falt and 20 mili metre shall be tapered in 45 on the inner side to form top and bottom rail and 115 mili metre wide Polyvenyle Chloride sheet out of which 75 mili metre shall be falt and 20 mili metre shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mili metre(+/0.25) thick Polyvenyle Chloride strip of 20 mili metre width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mili metre(+/0.25) thick Polyvenyle Chloride sheet to be fitted inside the Mild Steel frame welded/ sealed to the styles and rails with 5 mili metre(+/0.25) x 30 mili metrePolyvenyle Chloride sheet beading on either side and joined together with solvent cement adhesive etcetera ,10 mili metre thickness (5 mili metre(+/0.25) x 2 nos ) 20 mili metre wide cross Polyvenyle Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos Mild Steelpowder coated but hinges of size 100 mili metre x 25 mili metre x 2 mili metre using 32 mili metre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 mili metre size steel screws including fixture fasting. Complete as per direction of engineer in charge .
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing in position. (as per Indian Standard 1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mili metre at weight 0.547 Kilogram/Running Metre and window frame bottom track section 61.85 x 31.75 x 1.20 mili metre at weight 0.695 Kilogram/Running Metre Top and side track section 61.85 x 31.75 x 1.30 mili metre at weight 0.659 Kilogram/Running Metre The shutter should be of bearing bottom 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre Inter locking section 40 x 18 x 1.10 mili metre at weight 0.469 Kilogram/Running Metre And handle section 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre and top section 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mili metre thick plain glass with all required screws and nuts etcetera complete. With powder coating with box
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mili metre at weight 0.637 Kilogram/Running Metre with window frame bottom track section 92 x 31.75 x 1.30 mili metre at weight 1.070 Kilogram/Running metre Top and side track section 92 x 31.75 x 1.30 mili metre at weight 0.933 Kilogram/Running Metre The shutter should be of bearing bottom 40 x 18 x 1.25 mili metre at weight 0.417 Kilogram/Running Metre Inter locking section 40 x 18 x 1.10 mili metre at weight 0.469 Kilogram/Running Metre and handle and top section 40 x 18 x 1.25 mili metre at weight o.417 Kilogram/Running Metre As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mili metre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etcetera complete. With powder coating with box
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to Indian Standard 6524-1983 having 6 mili metre diametre bars 3 Numbers And stirrups @250 mili metre centre to centre and fixing in wall with 6 Nos of hold fast of 12 mili metre diametre bars 500 mili metre long including primer and oil painting etcetera complete) frame size 60 mili metre x 100 mili metre
C] Second Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mili metre minimum size, crossings of Mild Steel flats of size 18 x 5 mili Metre or E section for runner of minimum 40 x 6 mili metre size for flange, Mild Steel flat for top runner of minimum size 40 x 12 mili metre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mili metre maximum spacing of vertical channels be 100 mili metre enclosed gate position and clear space of 150 mili metre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etcetera complete. (Indian Standard 105211983).
Providing and fixing mild steel grill work for windows, ventilators, etcetera 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mili metre diametre and vertical pipe of 38 mili metre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 mili metre diametre in three rows, all pipes of 2 mili metre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mili metre diametre above newel post of 75 mili metre diametre etcetera complete (Prior approval of sample and brand by Executive Engineer is necessary before use)
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 25 mili metre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber].
Providing and fixing 15 mili metre diametre screw down bib/ stop tap of brass including necessary socket union nut complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 20 mili metre diametre screw down bib/ stop tap of brass including necessary socket union nut complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing screw down 15 mili metre diametre wheeled stop tap of brass including necessary sockets/union nut complete
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing push cock (Self closing tap) symet type of 15 mili metre diametre including necessary socket, testing etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 63x45 centi metre size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 15 centi metre x 10 centi metre salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying concrete pipes of Indian Standard NP. class of 150 mili metre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of Indian Standard NP. class of 300 mili metre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing, constructing and fixing 250 mili metre diametre Inspection chamber made up of Unplastisized Polyvenyle Chloride material of thickness 3.5 mili metre and height of 259 mili metre with inlet and outlet of 110 mili metre diametre with 75 mili metre diametre U Trap, Ultra shaft pipe of Unplastisized Polyvenyle Chloride material having height of 470 mili metre and fixing Ultra 250 mili metre diametre Unplastisized Polyvenyle Chloride cover and frame in 150 mili metre thick in Cement Concrete1:2:4, having crushed sand bed of 100 mili metre thick of size 550 mili metre diametre Including excavation and refilling the sides of chamber by crushed sand cushioning 150 mili metre thickness, connecting all required Unplastisized Polyvenyle Chloride fittings with rubber lubricant etcetera complete.
Providing, constructing and fixing 450 mili metre diametre Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mili metre and height of 388 mili metre with 160 or 200 mili metreain inlet (s) outlet and 110 and / or 160 mili metrebranch inlets, with 450 mili metre diametre Ultra shaft pipe of HDPE material having height of 460 mm, having Reinforced Cement Concrete cover and frame fixing in 150 mili metre thick in Cement Concrete1:2:4, having crushed sand bed of 150 mili metre thick of size 750 mili metre diametre Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mili metre thickness, connecting all required Unplastisized Polyvenyle Chloride fittings with rubber lubricant etcetera complete.
Providing and fixing 450 mili metre x 550 mili metre size superior type Belgium mirror with 16 mili metre diametre nickel plated towel rod etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing chromium plated towel rod 16 mili metre diametre and 75 centi metre in length including all accessories complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 mili metre incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etcetera complete.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etcetera complete."
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 40 mili metre diametre Ball cock medium type with Polyvenyle Chloride float including sockets and necessary fittings and tested as per municipal requirements etcetera complete.
C] Second Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 15 mili metre diametre Ball cock medium type with Polyvenyle Chloride float including sockets and necessary fittings and tested as per municipal requirement etcetera complete.
C] Second Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing Orissa Pan of size 580x445x260 mili metre with approved make flush valve including trap, Cast Iron soil and vent pipe upto outside face of wall including 100 mili metre diametre Cast Iron plug, bend and necessary pipe connection, etcetera complete. As directed by Engineer in charge.
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 75 mili metre diametre stabiliser pipe/ Poly Venyle Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetera complete
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 100 mili metre diametre stabiliser pipe/ Poly Venyle Chloride soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres
C] Second Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing on walls/ ceiling/ floor 15 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing on walls/ceiling/floor 20 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing on walls/ ceiling/ floor 25 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing on walls/ ceiling/ floor 32 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing on walls /ceiling/ floor 40 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing on walls/ ceiling/ floor 50 mili metre diametre CPolyvenyle Chloride pipe with necessary fittings, remaking good the demolished portion etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 15 centi metre rigid Polyvenyle Chloride Nahani trap including Polyvenyle Chloride grating ,bend,connectingpiece of Unplastisized Polyvenyle Chloride pipe up to the outside face of wall ,making the good damaged surface and testing etcetera complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing Poly Venyle Chloride Rain water pipes of 160 mili metre outer diameter and having wall thickness of 2.2 to 2.7 mili metreconfirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyle Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 mili metre to 40 mili metre from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Venyle Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etcetera complete.
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and laying in trenches 15 mili metre diameter CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
Providing and laying in trenches 20 mili metre diameter CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
Providing and laying in trenches 25 mili metre diameter CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
Providing and laying in trenches 32 mili metre diameter CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
Providing and laying in trenches 40 mili metre diameter CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
Providing and laying in trenches 50 mili metre diameter CPolyvenyle Chloride pipe including necessary excavation, fittings. Refilling trenches etcetera complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etcetera complete.
Providing and fixing in position Unplastisized Polyvenyle Chloride ultra violet stabilized 110 mili metre outer diameter cowl dome confirming to Indian Standard-4985 including making joints with solvent cement etcetera complete
C] Second Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing Glass self 125 mili metre wide and 600 mili metre long with necessary chromium plated brackets providing Teak Wood gutties etcetera complete
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing 90 centi metre x 60 centi metre Granite plate engraving 10 centi metre height letter, figures including painting the lefters/figures with approved colour and shade complete
Providing and fixing in position alluminium strips of size 50 mili metre x 3 mili metre for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etcetera complete
A] Parking Floor
B] First Floor
C] Second Floor
D] Third Floor
E] Fourth Floor
F] Fifth Floor
G] Sixth Floor
H] Seventh Floor
Providing and fixing lioghtening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 mili metre diametre 1.2 mili metre thick with multiple points head 1.2 Metric Tonne. long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 mili metre diametre of requiired length with Mild Steel round bnase plate 25 centi metre diam and 10 mili metre thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 centi metre diam x 45 centi metre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centi metre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 Kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 mili metre diametre 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
Providing soak pit of size 120 centi metre x 120 centi metre x 120 centi metre including excavating and filling with brick-bats.
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast Reinforced Cement Concrete rings, 300 mili metre thick side filling around outside of Reinforced Cement Concrete rings (annular space) with 40 mili metre size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75 mili metre clean washed gravels followed by 0.5m depth of 10-25 mili metre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etcetera) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etcetera) media layer including covering with Reinforced Cement Concrete slab, manhole frame & cover, Polyvenyle Chloride rungs etcetera including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Polyvenyle Chloride: -100 mili metre Outlet pipe size rigid Polyvenyle Chloride:-80 mili metre Gas outlet rigid Polyvenyle Chloride with Valve: 20 mili metre Bacteria immobilization Polyvenyle Chloride mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below c) Up to 25 user size (1.50 metrex1.0mx1.0m), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 Square Metre, Area of partition walls: 2 Square Metre, Total weight of frp: - 82.80 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5 mili metre, Number of inside partitions: - 3, Minimum thickness of partition wall: 3 mili metre
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid Polyvenyle Chloride: -100 mili metre Outlet pipe size rigid Polyvenyle Chloride:-80 mili metre Gas outlet rigid Polyvenyle Chloride with Valve: 20 mili metre Bacteria immobilization Polyvenyle Chloride mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below d) Up to 40 user size (2.0mx1.0mx1.0m), Capacity of biodgester:-2000 liters, Area of top, bottom and side walls: - 10 Square Metre, Area of partition walls: 3 Square Metre, Total weight of frp: - 106.20 Kilogram, Bacteria inoculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5 mili metre, Number of inside partitions: - 3, Minimum thickness of partition wall: 3 mili metre
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etcetera including bailing out water, Steel centering formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etcetera complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etcetera complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing fly ash brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etcetera Complete
Providing and fixing 50 mili metre diametre medium class Galvanised Ironpipe gate with wicket gate of approved drawing with all fixtures and fittings in two leaves with strong hold fast embedded in Cement Concrete block at top and bottom with locking arrangement including cutting, bending, making holes and with one coat of primer etcetera complete.
Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on Mild SteelAngles ( 50 mili metre x 50 mili metre x 6 mili metre) at 2.5 Mild Steel, Center to center including excavating pits for foundqtion, fixing post in cement cocnrete 1:4:8 of size 45 x 45 x 45 centi metre fastening the wire and painting the Mild SteelAngles with one coat of red lead primer and two coats of painting etcetera complete.
Providing earth work in embankment with approved materials obtained from departmental land including all lifts, laying in layers of 20 centi metre to 30 centi metre thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller to achieve not less than 97 % of standard proctor density etcetera complete. (Material obtained from departmental Land)
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate (Natural Sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mili metre,, cement content not to be less than 150 Kilogram/ Cubic Metre, Optimum Moisture Content (OMC)to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge, compacting with vibratory roller, finishing, curing and including preparation of sub-grade surface if required etcetera complete.
Providing and laying in situ cement concrete M -30 with tremix treatment for specified thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mili metre wide and 20 mili metre deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate (Natural sand/ VSI grade finely washed crushed sand) etcetera complete
Providing and fixing in position Thermo Mechanical Treated (TMT) FE 500, tie bars precoated with anticorrosive epoxy paint of 12 mili metre diametre 70 centi metre long and at 30.00 centi metre centre to centre and wherever directed including handling, straightening wrapping with paper of approved quality for half length, necessary cutting, handling, straightening, supported by assembly of Thermo Mechanical Treated (TMT) FE 500, chairs with proper alignment etcetera complete.
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
Spreading hard murum/ soft murum/ gravel or kankar for side width complete
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etcetera complete.
Transport of excavated materials obtained from road cutting including all lifts, inclusive from the site of excavation to the site of deposition as directed.
Dismantal material excavated material etcetera complete.
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etcetera complete,(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including steel centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/ pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etcetera complete. With fine aggregate (Crushed sand VSI Grade)
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mili metre thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etcetera complete.
Providing and fixing green marble of 18 to 20 mili metre thick for door frame/ dado/ window boxing etcetera On Cement Mortor 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etcetera complete.
Providing and applying two coat of water based cement paint to un plastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence etcetera complete. (applying 1 litre paint on 2 Square Metre)
Providing internal cement plaster 20 mili metre thick in single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etcetera complete
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etcetera complete.
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etcetera complete.
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mili metre with lock plate of 3.15 mili metre thickness reinforced with 35 x 35 x 5 mili metre angle section fitted with sliding bolts and handles for both sides, deep Mild Steel channel section of depth and thickness not less than 65 mili metre and 3.15 mili metre respectively with hold fast arrangements, Mild Steel Bracket plate 300 x 300 x 3.15 mili metre minimum size and shape with square bar, suspension shaft of minimum 32 mili metre diametre, hood cover of Mild Steel sheet not less than 0.9 mili metre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etcetera complete. (Indian Standard 62481979) (With mechanical gear)
Boring work (including transport.) 200/215 mm diameter in the soil / gravel surface Bore diameter of 150 mm in solid rock. This includes diameter drilling work. (Wet drilling) MJP Bore Well
After completion of drilling bore well, capacity test by flushing (air lift method) is measured with 90 degree "V" notch. MJP Bore Well
180 mm diameter PVC Casing pipe (8 kg / cm2) (IS 4985-1988) In exceptional circumstances / Casing pipes with a rock surface and if more than 40 feet of casing pipe is required, the casing should be used with the technical approval of the Deputy Engineer and Geologist
180 mm diameter PVC Casing pipe (8 kg / cm2) (IS 4985-1988) Casing lowering, grounding
180 mm diameter cap for PVC pipe.
Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etcetera
Dismantling the Reinforced Cement Concrete Work 1:2:4 and sorting out the materials such as steel etcetera as directed and stacking them within the specified lead as directed etcetera complete.
A] Parking Floor
B] First Floor
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etcetera
A] Parking Floor
B] First Floor
Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etcetera complete.
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etcetera complete
A] Parking Floor
B] First Floor
Removing brick bat coba including stacking the spoils as directed with all leads, lifts etcetera complete.
A] Parking Floor
B] First Floor
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etcetera complete.
A] Parking Floor
B] First Floor
Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etcetera complete.
A] Parking Floor
B] First Floor
Removing Water Closet pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materiasls out side etcetera carefully and throwing out the refusal outside etcetera complete.
A] Parking Floor
B] First Floor
Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etcetera complete
A] Parking Floor
B] First Floor
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessories on wall / ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected.
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.
Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB
Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
Supplying & erecting 14W, 230V integral type LED Lamp suitable for B-22 / E-27 base.
Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan.
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting SS enclosure for MCCB suitable for up to 100A MCCB.
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting plywood 12 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners supports, nuts bolts etc. complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB
Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company.
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting G.I. pipe ‘A’ class 50 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying & erecting 415V, 16A porcelain base neutral link complete erected in provided M.S. box.
Supplying and erecting hylam sheet/ ebonite 6 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Providing & erecting 4 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB.
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A up to 630A MCCB.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard
Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to 250A MCCB (Set of 8)
Supplying and erecting terminal spreaders suitable for 4 pole, above 250A up to 400A MCCB (Set of 8)
Providing & erecting prewired meter module suitable for MCCB panel board with CTs and emfs VIF meter.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting 25 mm dia. corrugated flexible polypropylene conduit
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting four pole ON LOAD change over switch, 415V, 32A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 .
Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50 c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose).
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 70 to 50 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003)complete, as per specification no. FF-MFP/JP
Supplying, installation, testing and commissioning of booster fire pump [BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 7.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d)Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C. Submersible/centrifugal pump set up to 7.5 HP - 10 H.P. consisting of DOL starter having relay range 28-42 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc.
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP (For 1 No. of building: 71 mtr X 9 building = 658)
Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings complete as per specification no. FF-PP (For 1 No. of building: 117 mtr X 9 building = 1053)
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system. (For 1 No. of building: 117 mtr X 9 building = 1053)
Supplying and erecting 150 mm dia cast iron foot valve ball type/flap type with strainer for negative suction complete as per specification no. FF-VL/FV (For 1 No. of building: 1 Nos X 9 building = 9)
Supplying and erecting 150 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS (For 1 No. of building: 1 Nos X 9 building =9)
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (For 1 No. of building: 8 Nos. X 9 building = 72)
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV (For 1 No. of building: 2 Nos X 9 building = 18)
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV (For 1 No. of building: 1 Nos X 9 building = 9)
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV (For 1 No. of building: (8 Nos X 9 building)+ 32 for Ring Main = 104)
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV (For 1 No. of building: (8 Nos X 9 building)+ 32 for Ring Main = 104)
Supplying, erecting testing and commissioning manual call point (Pill box) with break glass, push button (resettable type) in metal enclosure complete as per specification no. FF-FAAS/MCP
Supplying, erecting, testing and commissioning hooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of 4 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, 0 - 49 Deg C, 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF-FAAS/FACP
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV (For 1 No. of building: 8 Nos X 9 building=72)
Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL (For 1 No. of building: (16 Nos X 9 building)+ 64 for Ring Main = 208)
Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ (For 1 No. of building: (8 Nos X 9 building)+ 32 for Ring Main = 104)
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FMC
Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG(For 1 No. of building: 2 Nos X 9 building = 18)
Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS (For 1 No. of building: 2 Nos X 9 building = 18)
Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer dia with required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP (For 1 No. of building: (8 Nos X 9 building)+ 32 for Ring Main = 104)
Supplying and erecting M.S./CRCA cabinet for housing single hydrant valve of size ( 400 x 400 x 400)mm or hose pipe box of size ( 600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mm having front doors with viewing glass of size (200x150) mm and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) (For 1 No. of building: 8 Nos X 9 building =72)
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) (32 Nos for Ring Main = 32)
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete.
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. (For 1 No. of building: 8 Nos X 9 building= 72)
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.(For 1 No. of building: 8 Nos X 9 building = 72)
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.(For 1 No. of building: 28 Nos X 9 building = 252)
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.(For 1 No. of building: 8 Nos X 9 building= 72)
Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended up to 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete. (For 1 No. of building: 2 Nos X 9 building = 18)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (For 1 No. of building: 42 mtr X 9 building = 378)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (For 1 No. of building: 32 mtr X 9 building = 288)
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL(For 1 No. of building: 46 mtr X 9 building = 414)
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. (0.6+0.6m =1.2m x 120 Nos = 144 mtr x 3.5kg/mtr= 504 Kg)
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected.
Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW.
Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF
Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg · Floors :- G+7 floor (8 Stops/8 Landings) · Travel :- 21 to 29.4 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.5mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep, ......mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · ARD complete with necessary SMF VRLA batteries. · Lift controller of simplex full collective based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. ,various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 20" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg · Floors :- G+6 floor (7 Stops/7 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep, ......mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 10 Passenger/680Kg · Floors :- G+2 floor (3 Stops/3 Landings) · Travel :- 3 to 4.2 mtrs · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 800 mm wide x 2000 mm high · Clear Car size of ......mm wide x ......mm deep x 2250mm high · Lift shaft available having clear size of ......mm wide x ......mm deep, ......mm Pit depth, ………mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min.18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying & erecting 43" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following featuresBrightness: Minimum 500 Cd/m2Contrast Ratio: Minimum 1000:1Viewing angle: 178/178 deg.Response time: Maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-Monitor
Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following featuresImage Sensor : Minimum 1/2.8" Progressive Scan CMOS, Video Resolution : Minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : Minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, Minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - Minimum 0.2 Lux at color, Minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance Minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of Minimum 128 GB, Built in microphone. Minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CCTV.
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following featuresImage Sensor : Minimum 1/2.8" Progressive Scan CMOS, Video Resolution : Minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : Minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, Minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - Minimum 0.2 Lux at color, Minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance Minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of Minimum 128 GB, Built in microphone. Minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CCTV
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, Maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specifications CCTV-HDD
Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, Upto 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output upto 1920 × 1080. Support H.265 or higher, H.264, MJPEG, Incoming Bandwidth 250Mbps with Minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD upto 8TB, Minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications CCTV-NVR
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessories on wall / ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and fixing 1 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Providing and maintaining temporary 1 KVA on line UPS pure sine wave single phase 230V,50 Hz with required batteries suitable for 30 minutes battery backup to provided computer with necessary interconnecting cabling, wiring etc for three days.
Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.
Shubham EPC Private Limited
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid