Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹3.4 L−₹27,730 (7.50%)Accepted-AOC | L2 | Accepted-AOC As per L1 net bid amount | |
| 2 | L1₹3.7 LRejected-AOC | L1 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | CHAWLA ENTERPRISES L1 | ( Jatinder Enterprises ) Jatinder Sahni L2 |
|---|---|---|---|---|---|
| 1.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | |||||
| 1.01 | 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size) | 1 | Cum | 7,900 ₹7,900 Lowest | 8,000 ₹8,000 |
| 2.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 2 | Cum | 10,200 ₹20,400 Lowest | 10,500 ₹21,000 |
| 3.00Centering and shuttering including strutting, propping etc. and removal of form for | |||||
| 3.01 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. | 10 | Sqm | 650 ₹6,500 Lowest | 650 ₹6,500 Lowest |
| 3.02 | Suspended floors, roofs, landings, balconies and access platform | 10 | Sqm | 750 ₹7,500 Lowest | 800 ₹8,000 |
| 4.00Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level. | |||||
| 4.01 | Thermo-Mechanically Treated bars of grade Fe-500D or more. | 100 | Kg | 110 ₹11,000 Lowest | 110 ₹11,000 Lowest |
| 5.00 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). | 30 | Sqm | 230 ₹6,900 Lowest | 250 ₹7,500 |
| 6.00Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : | |||||
Tender Value
₹3.4 L
EMD Value
₹6,799
Closing Date
27 Mar 2025, 6:00 pmClosed
Executive Engineer Civil
BSNL Civil Division CTO Compound Nehru Garden Road Jalandhar
Misc repair and maintenance works in TE Building Vakilan Bazar Hoshiarpur for the year 2024-25.
2025_BSNL_230204_1
64/EE/BSNL/CD/JL/NIT/2024-25
Open Tender
Civil Works
Item Rate
90 days
Hoshiarpur
Please refer Tender documents.
10 documents required · 10 mandatory
₹590
Accounts Officer (Cash) O/o GMT BSNL
₹6,799
11 Aug 2025
18 Mar 2025
29 Mar 2025
18 Mar 2025
27 Mar 2025
18 Mar 2025
Amount
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with Cleaned F.P.S. bricks recovered from demolshing of brick work and supplied free of cost at site of work by the department in Cement mortar 1:6 (1Cement : 6 Coarse sand) in superstructure above plinth level up to floor V level in all shapes and sizes complete as per the direction of Engineer-In-Charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
Single tee without door
75 mm bend
110 mm bend
12 mm cement plaster of mix :
1:6 (1 cement:6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 metres lead :
With cement mortar 1:4 (1 cement : 4 fine sand).
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
Renewal of old putty of glass panes (length)
Refixing old glass panes with putty and nails
Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska :
With F.P.S. brick tiles
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning and de-silting of gully trap chamber/ floor trap , including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
In cement mortar
Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) :
From brick work in cement mortar
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all loads including all lifts involved.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
40 mm dia
Providing and fixing brass bib cock of approved quality :
15 mm nominal bore
Providing and fixing brass stop cock of approved quality :
15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
20 mm nominal bore
25 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions :
45 cm length
15 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work):
15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
32 mm nominal bore
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15mm nominal bore
Supplying and fixing C.I. cover without frame for manholes :
455x610 mm rectangular C.I. cover with frame (light duty) total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
Chipping of unsound/weak concrete material from slabs, beams, Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including eaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of egineer-In-Charge.
75 mm average thickness
50 mm average thickness
25 mm average thickness
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
Bars upto 12 mm diameter
Bars above 12 mm diameter
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200 mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.
Upto and including 12mm dia.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect..
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing and fixing PVC covers with all necessary fittings of approved quality to PVC water storage tanks of capacity up to 1000 litres placed on terrace up to level-5 all complete as per the directions of Engineer-in-Charge.
Repair to leaking G.I.water supply pipe line by dismantling the G.I. pipe, replacing the GI pipe and fittings where required and restoring the water supply upto 15 metre height all complete as per direction of the Engineer-in-Charge.( GI pipes and fittings shall be paid for separetely).
Re-setting of existing aluminum door/window shutters , tightening of cleats etc. refixing of pivots or aluminium hinges or rubber gasket/floor spring/door fittings wherever required including steel screws etc. all complete
Repair to floor trap/P-trap etc. with neat cement slurry including mixing of water proofing solution to prevent leakage as per the direction of Engineer-in-Charge.
Removal of Plants like Pipal Plant etc. from the roofs,shafts and from other parts of the Building at all heights and removing its roots,And pouring solution of Chlorpyriphos E.C 20% in the root of plants and making good the same complete as per direction of Engineer-in-Charge.
Uprooting of plant without using scaffolding
Terrace/floor cleaning including removal of rank vegetations,grass etc. and its disposal outside the compound to a municipal dump all complete as per direction of Engineer-in-Charge.
Cleaning of Manholes including taking out the sludge,rubbish and other forgien materials for smooth and free flow of sewage water all complete as per the direwction of E-I-C.
Repairs to existing doors/windows/cupboard shutters (wood) by chiseling,cutting and tightening the styles and rails etc. wherever required including dismantling and refixing the same all complete as per the directions of Engineer-in-Charge.
Providing and fixing 100 mm stainless steel grating with or without hole for nahni or floor traps etc. all complete as per the directions of Engineer-in-Charge..
Repairs to SCI rain water/sanitary pipes i/c dismantling from its existing position and refixing the same at all floor levels,i/c necessary scaffolding if required after making necessary repair by using M-seal or other sealing compound on all the leaked joints/cracks etc. all complete as per direction of Engineer-in-Charge.
Up to 100m dia
Providing and fixing 1.50 mm thick skylite polycarbonate sheet fixed with necessay screws/rivets/ self thread over frame made of 25 mm x 25 mm x 2.00 mm MS square tube etc. all complete as per the directions of Engineer-in-Charge. (Note :- Frame made of 25 mm x 25 mm x 2.00 mm MS square tube measured separately)
Providing and fixing CP brass waste coupling of approved brand upto 40mm dia to wash basin/sink/ urinal to complete as per directoin of E-in-Charge
Repairs to brass bib cock, stop cock, PVC connections ,shower,gate valve, ball cock by replacing washers or jumpers etc all complete as per direction of Engineer-in-Charge.
Repairs to C P brass pillar cock, bib cock, stop cock, angle valve by replacing brass spindle etc all complete as per direction of Engineer-in-Charge.
Providing and fixing CP brass pillar Cock of approved brand i/c dismantling the existing pillar cock etc. all complete as per direction of Engineer-In-Charge
15mm nominal bore
Providing and fixing GI fittings in existing GI Pipe line etc all complete as per direction of Engineer-in-Charge.
G.I Nipples ( length up to 150 mm )/socket/elbow/reducer elbow/Tee
15 mm to 25 mm dia
32mm to 40mm dia
Repairs to existing MS steel gate shutters with electric/gas welding wherever required , setting right in all respect for smooth functioning with or without dismantling etc. all complete as per the directions of Engineer-in-Charge.(Note :- Cost includes transportation of complete electric/gas welding set to site ).
Size up to 2.00 x 3.50 M
Credit for old dismantled/unserviceable material received from dismantling: -
Brass bib cock/stop cock/ Ball Valves / CP bib cock / CP stop cock,C.P angle Valves ,CP pillar cock,,brass gate valves, PVC flush cistern etc.
PVC Connections
Old rusted iron/steel members, GI Pipes
( Jatinder Enterprises ) Jatinder Sahni (BID ID -834908)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .