Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | ₹12.5 L Quoted ₹13.5 L | L1 | Accepted-AOC lowest |
| 2 | L2₹14.5 L+₹1.0 L (7.79%)Rejected-AOC | ₹14.5 L+₹1.0 L (7.79%) | L2 | Rejected-AOC not found lowest |
| 3 | L3₹14.9 L+₹1.4 L (10.6%)Rejected-AOC | ₹14.9 L+₹1.4 L (10.6%) | L3 | Rejected-AOC not found lowest |
| 4 | L4₹15.2 L+₹1.8 L (13.1%)Rejected-AOC | ₹15.2 L+₹1.8 L (13.1%) | L4 | Rejected-AOC not found lowest |
| 5 | L5₹15.6 L+₹2.1 L (15.8%)Rejected-AOC VILL BUNGDAL DADHANI P O BADHANI DISTT PATHANKOT PIN 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹15.6 L+₹2.1 L (15.8%) | L5 | Rejected-AOC not found lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
22 Jun 2022, 6:00 pmClosed
GE Basoli
GE Basoli PO lakhanpur Distt Kathua JK
REPAIR AND MAINTENANCE OF LT OH LINE, LT UG CABLE /AB CABLE, LT PANELS, LT SWITCH GEARS AT BASOLI STATION UNDER GE BASOLI.
2022_MES_525108_1
GE/BAS-16/2022-23
Open Tender
Civil Works
Item Rate
180 days
Area of Basoli
Class E catg b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Basoli
₹30,000
Yes
30 Dec 2022
20 May 2022
24 Jun 2022
20 May 2022
22 Jun 2022
8 Jun 2022
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5mtr in depth for foundation of pole and lying of UG cable and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches n. exc 1.5 mtr wide and exc 1.5mtr in depth for foundation of pole and getting out in any type of soil complete all as specified and as directed.
Returning filling in and including spreading, leveling, watering and well ramming in layers not exceeding 25cm in layers completed all as specified and directed.
Supply & laying of approved quality sand under cable up to 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed. (Punned thickness shall be measured)
Material and labour for well burnt, old size Sub Class 'B' brick covering protection to the electric cable laid dry flat transversally along the length of cable with width equal to length of brick complete all as specified and directed.
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and as directed.
M&L for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded stone aggregate for foundation of poles and stay assembly, complete all as specified and as directed.
Restretching of existing loose OH,LT ACSR conductor wire including GI wire along the span of poles for sagging within the permissible limit,(five/four/two wire line), including binding/rebinding/joining with Aluminum winding wire in case of breakage of conductor, size of binding wire shall not be less than 2 sqmm complete all as specified and directed. Note: (i) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during the stretching. (ii) The Number of wires between pole to pole shall be consider as one span and no claim on this account is admissible.(iii) The item shall be execute only after site visit and written approval of GE .
M&L for trimming /cutting tree branches with clearing space up to 2 meter from the over head conductor system all around for LT distribution system , and as directed. Note: (i) The contractor shall take permission from GE for power shutdown before start work on line.(ii)The item shall be execute only after site visit and written approval of GE .(iii) The distance between pole to pole shall be consider as one span.
S&F in repair, structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including, nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat, one finishing coat of aluminum paint and epoxy coating, including taking down old corroded structural steel, complete all as specified and as directed.
S & F in repair, shackle type, vitreous Insulator including one galvanized mild steel spindle, two galvanized iron washers, and one galvanized iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt, complete all as specified and as directed. Make-Jaipuria/RASHTRIYA/ PACTAL
S&F stay assembly complete comprising of 20mm dia 40cm long stay bow rod 20mm dia x 1.8 Mtr long galvanized stay rod threaded with nuts, including 300mmx300mmx6mm thick plate necessary clamps etc as shown on plate No. 1 on page 495 of SSR Part-I, 2009 including taking down U/S stay assembly, complete all as specified and as directed. (Note: Loop type insulator, stay clamp, stay wire, excavation and concrete work shall be measured and paid for separately).
S&F galvanized steel stranded stay wire size 7/4mm for stay assembly, complete all as specified and as directed.
S&F in repair loop type insulator with complete fitting porcelain, vitreous white or brown large size with over all dimensions 90x140mm, clearance of hole 25.5mm, complete all as specified and as directed.
M&L earthing complete with galvanized steel earth plate electrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edges, of the plate not less than 1.5m below normal ground level, connected to the Galvanized Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanized iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplus soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillars and Transformer all as specified including testing on completion complete all as specified and directed.
Supply and Laying in trenches or passing through pipe or fixing to pole/wall UG cable XLPE 300 sqmm, 3.5 core, PVC insulated, armored heavy duty electric cable with aluminum conductor,1100 Volts grade, cross section area are as under, including disconnecting and taking out old unserviceable LT/AB cable. Note : (I) Earth work/ sand cushioning shall be measured and paid separately .
All as per item above but 95 Sq mm X 3.5 core
All as per item above but 50 Sq mm X 3.5 core
All as per item above but16 Sq mm X 4 core
All as per item above but25 Sq mm X 3.5 core
All as per item above but16 Sq mm X 2 core
Taking out the old unserviceable cable for repair from trenches or passing through pipe /fixed to pole/ wall XLPE insulated 300/240/ 185 Sqmm X 3.5 core armored, heavy duty, electric cable and depositing in the MES store yard.
All as per item above but 70/50/35 Sqmm X 3.5 core
All as per item above but25/16/10 Sqmm X 3.5/4/2 core core
S & F in repairs cable end joint kit for 1100 volt, outdoor type joint complete with all jointing material and accessories suitable for 3.5 core cable of size 50 sqmm to 300 sq mm all as directed.
S&F DWC high density polyethylene pipes in replacement having 63/50outer dia mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable complete all as specified and directed. Make -Trupati /Equivalent
S&F DWC high density polyethylene pipes in replacement having outer dia 90/76 mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable complete all as specified and directed.
S&F DWC high density polyethylene pipes in replacement having outer dia 120/103 mm, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable complete all as specified and directed.
Supply and erect steel tubular swaged pole type 410 SP-31 (9 meter long) complete with cast iron / MS base plate, top plate welded with MS round sheet with necessary nuts, bolts and wahsers duly painted with a coat of red oxide primer and two coat of aluminum paint including black and yellow strip 30cm in height above the copying of the pole, including taking out old poles, complete all as specified and as directed.
S&F in repairs, new aluminum conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminum tape/binding wire connectors, PG clamps, jumpers etc of any size as per site requirement, complete all as specified and as directed.
S&F in repairs, galvanized steel wire 3.15 or 4mm dia cradle guards, hexagonal/rectangular fabricated of galvanized steel wire 3.15mm dia including binding wire aluminum , cradle guard complete all as specified and as directed.
S&F in replacement single phase preventer for Electric driven Machine Motor 415 Volts AC 50 Hz complete all as specified and as directed. Make: - L&T, Havells and Siemens.
Material and labour for painting of 9 mtr LT Steel pole with one coat of red oxide and two coat aluminum paint and marking yellow and black lines including writing pole number with black synthetic enamel paint ,complete all as specified and as -directed.
Material and labour for applying two coats of cement base paints over PCC electric poles and marking yellow and black lines including writing pole number with black synthetic enamel paint ,complete all as specified and as -directed. Note :- The item shall be executed if specifically ordered by GE in writing.
SHUSHANT ASSOCIATES
KALSI CONSTRUCTION CO
dinesh enterprises
M/S CANTILEVER ENGINEERS
kailu construction co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .