Executive ENgineer
Office of the Executive Engineer Divsion VI Mapusa
Work of Renovation of Bastora panchayat DTC,Mapusa Tar DTC,Teliyawaddo DTC Bastora,Lozar DTC Quitla and Dharwadkar DTC Golna Pomburpha,under the jurisdiction of section office Aldona,Sub Division-III(R) Mapusa Division VI Mapusa.
2026_ED_27912_1
Tender47(25-26)/6900 24/02/2026
Open Tender
Electrical Works
Percentage
90 days
Aldona Goa
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹47,909
10 Apr 2026
24 Feb 2026
12 Mar 2026
25 Feb 2026
10 Mar 2026
27 Feb 2026
cost of material
Supply and Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel
Earthing complete with Class B, 100 mm dia nominal bore, 3000 mm long pipe earth electrodes with test Connection links having welded flat of size 50 x 6 mm for connecting earth strip, RCC chamber, CI cover hinged to CI frame, other accessories as per Technical specs, alongwith required quantity of charcoal, salt etc or Bentonite to be buried below ground and to be connected with earth mat of MS Flat. i.e. Chemical Earthing.
Naming of RCC Earthing chambers.
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing
GI Tubular Fencing complete with gate and side dismantling system as per the specification for Distribution Transformer and Feeder Pillars (Size 4M X 3M X 2M) with concreting for GI fencing supports with plinth (0.30 x 0.30 x 0.5) C. um x 12 nos; and brick masonry (each ratio 1:3:6). Galvanising should be hot dipped Galvanised as per IS 2629/66 c: minimum Zinc coating of 1000 gms/sq.mtr; 140 Microns DFT; suitable for high salinity coastal areas.and as per specifcation
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.
Supply and Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof
Supply and Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.
Supply and Erection Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)
Supply and stringing of ACSR conductor 'Weasel'
Supply and Erection of DTC Metering Unit
cost of erection
Supply and Erection of RCC pole 11 mtr as per the drawing No.CEE/E-698 REV-3 as per annexure confirming to IS 785-1998 as amended upto date. The component used for pole shall conform to following IS amended up to date. 1) Ordinary Port land cement 53 grade IS 12269 2) Aggregate IS 383-1970 3) Torsteel IS 1786-7985 4) MS bar IS 432 p 1 & 2-1982
Supply and Erection HDGI DP Structural material shall include :-a) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for incoming line & installation of disc insulators b) GI channel ISMC75x40x7.3mm 2.75mtrs long 2 pieces for GOAB switch c) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for HG fuses d) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for installation of lightening arrestor e) GI channel ISMC 100x50x7.3mm 2.75 mtrs long 2 pieces for installation of Trasformer f) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 2 pieces for side support of trasformer g) GI channel ISMC 75x40x7.3mm 2.75 mtrs long 4 pieces for installation of any other items h) GI channel ISMC 100x40x7.3mm 0.52 mtrs long 2 pieces for installation of Transformer base channel
Supply and Erection 11 KV rated voltange GOAB switches tilting type, outdoor, manually operated, triple pole, single break, conforming toIS-9921 (Part-I to IV) [ 1981 - 85] as amended up to date and detailed specification eclosed herewith. Each set shall comprise of six pedestal and three tilting post insulators. Insulator should be factory cemented by the manufacturer of the insulators and have minimum 320 mm creepage distance and AB switchs contacts shall be of copper/ copper alloy. The AB switch shall be of following current rating: 200 A
11 KV , 200 A Horn gap fuse unit (Set of three) shall be as per drg No. CEE/E-786 as per annexure confirming toI.S. 2062,IS: 1367,IS: 4218,IS: 1363,IS-209 1979 or the latest version thereof
Supply and Erection of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor conforming to IEC-600994-4 and IS: 3070 part 3 1993 as amended upto date suitable for 11 KV 50 HZ effectively earthed neutral system with necessary mounting arragements and connector suitable to connect ASCR conductor upto overall diameter 12.30 mm
Earthing complete with Class B, 100 mm dia nominal bore, 3000 mm long pipe earth electrodes with test Connection links having welded flat of size 50 x 6 mm for connecting earth strip, RCC chamber, CI cover hinged to CI frame, other accessories as per Technical specs, alongwith required quantity of charcoal, salt etc or Bentonite to be buried below ground and to be connected with earth mat of MS Flat. i.e. Chemical Earthing.
Supply and Erection PVC insulated single core cable 50 mm2 for D.P. earthing
GI Tubular Fencing complete with gate and side dismantling system as per the specification for Distribution Transformer and Feeder Pillars (Size 4M X 3M X 2M) with concreting for GI fencing supports with plinth (0.30 x 0.30 x 0.5) C. um x 12 nos; and brick masonry (each ratio 1:3:6). Galvanising should be hot dipped Galvanised as per IS 2629/66 c: minimum Zinc coating of 1000 gms/sq.mtr; 140 Microns DFT; suitable for high salinity coastal areas.and as per specifcation
Supply and Erection XLPE Single Core unarmoured 300 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 300 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date. (From transformer to DB)
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 300 sq.mm
Supply and Erection XLPE cable armoured 3 1/2 CX 185 sq mm,cross linked polyethelene insulated, PVC shealthed 1 core 120 sqmm cable 1.1.KV gradesuitable for 3 phase earthed system and conforming to IS: 7098 (Part-I)/1988 as amended upto date.(LT Feeder Cable )
Supply and Erection of Aluminium crimping Lugs shall conform to IS: 8309-1976 as amended upto date. Lugs shall be made of aluminium of grade IE of IS: 5082/1969 suitable for aluminium cable of 185 sq.mm
Supply and Erection Enamelled Danger board 400V of size 250mm x 200 mm as per the drawing No. CEE/E-490.
Supply and Erection Anticlimbing deviceas per the drawing No. CEE/E-478.
Supply and Erection HDGI 2 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/704 as per annexure confirming to IS- 2633/72 or the latest version thereof
Supply and Erection HDGI 4 pin 'X' arm of 75 x 40 Channel as per the drawing No.CEE/E/705 as per annexure confirming to IS- 2633/72 or the latest version thereof.
Supply and Erection HDGI X arm clamps for RCC Pole 11.00 mtr L.A as per the drawing No.CEE/E-711 as per annexure confirming to IS- 2633/72 or the latest version thereof
HDGI stay clamps for RCC Pole 11.00Mts L.A.
Supply and Erection of HDG.I. stay wire 7/10 SWG conforming to IS-2141/1979 grade- I, IS:4826-1979 & IS:6594-1974 or latest version thereof with tensile grade 4 & having minimum tensile strenght of 700N/mm2 conforming to IS:2141 or the latest version thereof
Supply and Erection of H.D.G.I. stay rod of 1200mm long and 16mm dia with an eye band of internal dia 40mm at one end and threaded up to length of 200mm at the other end galvanised. H.D.G.I.stay plate of 450x450x8mm size with a hole drilled at the centre to suit 16mm dia GI rod galvanised.as per the drawing No. CEE/E-465
Supply and Erection G.I. Turn Buckle with eye bolt 11 KV as per the drawing No. CEE/E-466
Supply and Erection of Break insulators 8 KV (44KN) as per the drawing No. CEE/E-425 as per annexure confirming to the IS:5300-1969 or the latest version thereof
G.I. Nuts & Bolts as per annexure confirming to the IS- 2633/72 or the latest version thereof
Supply and Erection of LT brown glazed shackle Insulator of size 100 mm x 115 mm conforming to fig No. 4 and type 2 fo IS: 1445/77 as amended upto date. Minimum failing load shall be 16 KN with GI hardware suitable for LT shackle insulator of size 100 x 115 mm conforming to type 2 fig 4 of IS: 1445/77 as amended upto date as per the drawing No.EE/X/TRN/DRG1/2.
Supply and Erection Metal parts for L.T. Shackle insulators or the Strap type fittings shall consists of a pair of H.D.G.I. straps, 2nos. H.D.G.I. bolts with hexagonal head & nuts, 2 nos. H.D.G.I. spring washers, & helically formed conductor dead-end fittings made of aluminium alloy or aluminium-clad steel conforming to the relevant IS specifications as per the drawing No.EE/X/TRN/DRG1/2.
Supply and Stringing of AAC 'ANT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/3.10mm aluminium, (nominal aluminium area 50mm)
Supply and Stringing of AAC 'GNAT' Conductor, hard drawn stranded aluminium conductor & conforming to IS:398(Pt-I/76) with ammendment no. 1,2 & 3 & of size 7/2.21mm aluminium, (nominal aluminium area 25mm2)
Supply and stringing of ACSR conductor 'Weasel'
Removing and Re erection of 200 KVA 11kv/.4kv Distribution Transformers level II losses, Alluminium Winding, with Bimetallic Terminal Connectors, Energy Efficiency Level-II as per IS: 1180 (Part-I): 2014
Supply and Erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre
Removing and Re erection of MS Distribution box as per drg No. CEE/E-689 Revision No. 2 along with MCCB 400 A, Bus bar made out of Aluminium strips 40 x 10 mm, Other accessories & 200 Amps, Porcelain KitKat Fuse Carrier & Base with extended terminals shall be as per drawing No.CEE/E/543-Rev 4 (Set of 3) for 4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre
Aluminium paint for MS Distribution box and Metering Unit
Supply and Erection of DTC Metering Unit
Removing and Re erection of DTC Metering Unit
Removing and Re erection GI Pipe 100 mm , class B
Removing and Re erection XLPE cable of voltage 11 KV 3 core 95 Sq.mm excluding cable end termination.(From RMU to Transformer )
Removing and Restringing AAC conductor 'ANT'
Removing and Restringing AAC conductor 'GNAT'
Removing RCC poles 9 mtr
Removing of Rail Pole 90 lb/yd 11 mts
Removing HDGI 2 pin 'X' arm of 75 x 40 Channel
Removing HDGI 4 pin 'X' arm of 75 x 40 Channel
Removing L.T. Shackle insulators
Removing Metal parts for L.T. Shackle insulators
Removing of HDGI DP Structure Material
Removing of 11 KV rated voltange GOAB switchesof following current rating: 200 A
Removing of 11 KV , 200 A Horn gap fuse unit (Set of three)
Removing of 9 KV, 5 KA nominal discharge current metal oxide gapless distribution class Lightning arrestor
Removing of XLPE cable armoured 3 1/2 CX 185 sq mm, cable 1.1.KV .(LT Main Cable )
Removing of XLPE Single Core unarmoured 300 sq mm cable
Removing of MS Distribution box ,4 feeder arrangement with 1 no of moulded case circuit breaker (MCCB) of 400A, 415V, AC 50 Hz for 100 KVA Distribution Transformer centre
Removing of DTC Metering Unit
stage.html
html • 0.04 MB
technical_28357.pdf
techsummary_28357.pdf
finance_28357.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 25.50 MB
BOQ_28357.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .