Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.6 Cr+₹10.8 L (7.06%)Admitted-Finance | ₹1.6 Cr+₹10.8 L (7.06%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MD SHAHADAT L2 | AMAR RANJAN KUMAR L1 |
|---|---|---|---|---|---|
| 1.00SCHEDULE ‘A’ PART-I ( BUILDING WORKS) | |||||
| 1.01 | Construction of Single Men Barrack of size 15 M x 8 M incl verandah using MS Tubular structure for wall and roof frame wk, AC Plain sheet false ceiling with wooden frame, One side Decorative veneer for internal wall cladding, Wooden doors and windows, PCC flooring, CGI sheet Roofing and wall cladding using 0.63 mm thick CGI Sheet with wind tie at roof all as per drawing and specification and as specified in HQ DGAR Drawing No DGAR/ENGR/COB/097 | 4 | job | 21,00,000 ₹84,00,000 | 19,00,000 ₹76,00,000 Lowest |
| 1.02 | Construction of Single Offrs / Single JCOs Accn of size 9 M x 8 M using MS Tubular structure for wall and roof frame wk, AC Plain sheet false ceiling with wooden frame, One side Decorative veneer for internal wall cladding , Wooden doors and windows for wall and roof frame wk, PCC flooring with glazed ceramic tiles, CGI sheet Roofing and wall cladding using 0.63 mm thick CGI Sheet with wind tie for roof all as per drawing and specification and as specified in HQ DGAR Drawing No DGAR?ENGR/COB/98A | 2 | job | 20,00,000 ₹40,00,000 | 16,00,000 ₹32,00,000 Lowest |
| 1.03 | Construction of Kote bldg of size 15 M x 8 M incl verandah using MS Tubular structure for wall and roof frame wk, PCC flooring, CGI sheet Roofing and wall cladding using 0.63 mm thick CGI Sheet with wind tie on roof all as per drawing and specification and as specified in HQ DGAR Drawing No DGAR/ENGR/COB/099 | 1 | job | 20,00,000 ₹20,00,000 | 19,00,000 ₹19,00,000 Lowest |
| 2.00SCHEDULE ‘A’ PART-II (INTERNAL ELECTRIFICATION OF KOTE BLDG) | |||||
| 2.01 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.50 sqm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.50 sqmm FR PVC insulated copper conductor single core cable etc as required. Group A | 15 | job | 1,000 ₹15,000 | 900 ₹13,500 Lowest |
| 2.02 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 3 pin 5/6 amp socket outlet | 2 | job | 200 ₹400 Lowest | 1,300 ₹2,600 |
| 2.03 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 5/6 amps switch | 15 | Point | 150 ₹2,250 | 55 ₹825 Lowest |
| 2.04 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. | 60 | Pts | 1,200 ₹72,000 | 45 ₹2,700 Lowest |
| 2.05 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing nction box/ wooden block including connection etc as required. | 10 | Nos | 50 ₹500 | 30 ₹300 Lowest |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
21 Nov 2020, 6:00 pmClosed
SO1 Works HQ DGAR
ENGR Branch SO1 Works HQ DGAR, Laitkore Shillong
04 Nos PFTS for SM Bks 01 No PFTS for SOffrs Accn 01 No PFTS for SJCOs Accn and 01 No PFTS for Kote including allied works for COB Laki of Lunglei AR Bn Mizoram
2020_ARMHA_596346_1
VIII.11014/5027/Engr-2020/23 Sect/02
Open Tender
Coal Works
Works
365 days
LAKI COB of Assam Rifles
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
SO1 (Wks), HQ DGAR, C/o 99 APO
₹3.5 L
21 Dec 2020
11 Nov 2020
23 Nov 2020
11 Nov 2020
21 Nov 2020
12 Nov 2020
11 Nov 2020 - 21 Nov 2020
Amount
SCHEDULE ‘A’ PART-I ( BUILDING WORKS)
Construction of Single Men Barrack of size 15 M x 8 M incl verandah using MS Tubular structure for wall and roof frame wk, AC Plain sheet false ceiling with wooden frame, One side Decorative veneer for internal wall cladding, Wooden doors and windows, PCC flooring, CGI sheet Roofing and wall cladding using 0.63 mm thick CGI Sheet with wind tie at roof all as per drawing and specification and as specified in HQ DGAR Drawing No DGAR/ENGR/COB/097
Construction of Single Offrs / Single JCOs Accn of size 9 M x 8 M using MS Tubular structure for wall and roof frame wk, AC Plain sheet false ceiling with wooden frame, One side Decorative veneer for internal wall cladding , Wooden doors and windows for wall and roof frame wk, PCC flooring with glazed ceramic tiles, CGI sheet Roofing and wall cladding using 0.63 mm thick CGI Sheet with wind tie for roof all as per drawing and specification and as specified in HQ DGAR Drawing No DGAR?ENGR/COB/98A
Construction of Kote bldg of size 15 M x 8 M incl verandah using MS Tubular structure for wall and roof frame wk, PCC flooring, CGI sheet Roofing and wall cladding using 0.63 mm thick CGI Sheet with wind tie on roof all as per drawing and specification and as specified in HQ DGAR Drawing No DGAR/ENGR/COB/099
SCHEDULE ‘A’ PART-II (INTERNAL ELECTRIFICATION OF KOTE BLDG)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.50 sqm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.50 sqmm FR PVC insulated copper conductor single core cable etc as required. Group A
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 3 pin 5/6 amp socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 5/6 amps switch
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing nction box/ wooden block including connection etc as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 4 way, Single door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole and neutral(SPN)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (SP)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
S/F house service bracket(hook type) complete with 3.00 mtr long GI pipe, 40 mm dia med grade, two nos 90 bends, MS hook stay or guy.
S/F 1100 volts grade heavy duty cable PVC insulated inner sheathing of PVC tape and over all PVC sheated in service connection suspended by insulating hangers not more than 1.00m apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor 6 sqmm size ISI marked of approved quality.
Supply and Fixing of fancy light fitting of approved make
SCHEDULE ‘A’ PART-III (ELECTRIC WORK S M Bk)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.50 sqm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.50 sqmm FR PVC insulated copper conductor single core cable etc as required. Group A
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 3 pin 5/6 amp socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 3 pin 15/16 amp socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 3 pin 5/6 amp socket outlet
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing nction box/ wooden block including connection etc as required.
Supplying and fixing metal box of 150 mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 4 way, Single door
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole and neutral(SPN)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (SP)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required.
Installation of exhaust fan in the existing opening, including making good the Upto 600 mm sweep incl Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
S/F house service bracket(hook type) complete with 3.00 mtr long GI pipe, 40 mm dia med grade, two nos 90 bends, MS hook stay or guy.
S/F 1100 volts grade heavy duty cable PVC insulated inner sheathing of PVC tape and over all PVC sheated in service connection suspended by insulating hangers not more than 1.00m apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor 6 sqmm size ISI marked of approved quality.
Supply and fixing of LED TUBE light fittings of approved brand(Bajaj/Havells/V GoardISI marks) 20 Watt
Supply and fixing of LED BULK HEAD fittings of approved brand(Bajaj/Havells/V GoardISI marks) 20 Watt
Supply and fixing of CFL/bulb holder of approved make
Supply and Fixing of ceiling fan of approved make(Bajaj/Havells/V Goard /Usha or equivalent to ISI marks)
SCHEDULE ‘A’ PART – IV (INTERNAL ELECTRIFICATION OF SINGLE OFFRS/SINGLE JCOs ACCN)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.50 sqm FR PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.50 sq mm FR PVC insulated copper conductor single core cable etc as required. Group A
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 3 pin 5/6 amp socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 6 Pin 15/16 amps socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. 5/6 amps switch
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing metal box of 150 mm X 75mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 4 way, Single door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole and neutral(SPN)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (SP)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required
Installation of exhaust fan in the existing opening, including making good the Upto 600 mm sweep incl Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes
S/F house service bracket(hook type) complete with 3.00 mtr long GI pipe, 40 mm dia med grade, two nos 90 bends, MS hook stay or guy.
S/F 1100 volts grade heavy duty cable PVC insulated inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1.00m apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor 6 sq mm size ISI marked of approved quality.
Supply and fixing of LED TUBE light fittings of approved brand(Bajaj/Havells/V GourdISI marks) 20 Watt
Supply and fixing of LED BULK HEAD fittings of approved brand(Bajaj/Havells/V GourdISI marks) 20 Watt
Supply and Fixing of PVC bulb/CFL holder of approved brand(Bajaj/Havells/V Gourd ISI marks) 20 Watt
Supply and Fixing of ceiling fan 1200 MM SWEEP of approved make(Bajaj/Havells/V Gourd /Usha or equivalent to ISI marks)
Supply and Fixing of Exaust fan 600 MM SWEEP of approved make(Bajaj/Havells/V Gourd /Usha or equivalent to ISI marks)
SCHEDULE ‘A’ PART - V (WATER TANK STAGING DRG NO DGAR/ENGR/COB/102)
Excavation work in foundation trenches or drains not exceeding 1.50m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.50 m, including getting out excavated soil and disposal of surplus excavated soil as directed within 50m lead. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work upto plinth level 1:3:6 using 40mm nominal size graded aggregate
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work upto plinth level 1:3:6 using stone aggregate 40mm nominal size
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution
SCHEDULE ‘A’ PART - VI (INTERNAL WATER SUPPLY AND SANITORY INSTALLATION OF SINGLE OFFRS/SINGLE JCOs ACCN)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets,40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, /c cutting and making good the walls etc. 15 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps,/c cutting and making good the walls etc. 20 mm dia nominal bore
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete
Providing and fixing toilet paper holder : 17.34.1 C.P. brass
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet100 mm diameter :
Providing and fixing cast copper alloy pillar cock of approved quality and colour .20 mm nominal bore, CP
Providing and fixing PTMT bib cock of approved quality and colour. 18.54.1 15mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing and fixing PTMT stop cock of approved quality and colour 18.55.1 15 mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.1 Kitchen sink with drain board
SCHEDULE ‘A’ PART - VII (SEWAGE SYSTEM FOR S/OFFRS/S JCOs)
Constructing of 50 user septic tank for toilet blocks with common burnt clay F.P.S (non modular) bricks of class designation 7.5 and RCC slab cover all as per drawing and specification and Drawing No MRR/Engr/115/02 sheet no 2/2
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design 19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 MRR/Engr/115/02 sheet no 2/2
Constructing masonry chambers 60x60x75 cm inside, in brick work in cement mortar 1:4 for sluice valve, with C.I. surface box 100mm top dia 160mm bottom dia and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 using graded aggregate 20mm nominal size including necessary excavation, foundation concrete 1:5:10 using graded aggregate 40 mm nominal size and inside plastering with cement mortar 1:3, 12 mm thick finished with a floating coat of neat cement complete as per standard design with common burnt clay F.P.S (non modular) bricks of class designation 7.5 MRR/Engr/115/02 sheet no 2/2
SCHEDULE ‘A’ PART - VIII (DEVELOPMENT WKS)
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kinds of soil
MD SHAHADAT
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .