Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance F 67 SHIV NAGAR BEHIND A G OFFICE JAMMU JAMMU JAMMU KASHMIR 180001 | JAMMU | JAMMU AND KASHMIR | 180001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹70.4 L
EMD Value
₹1.4 L
Closing Date
31 Jan 2020, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please reffer BOQ
2020_PWDJK_91063_1
Fresh e-NIT No.EDJ/226 of 2019-20 Dated 23-01-2020
Open Tender
Electrical Works
Item Rate
Govt Press Ambphalla Jammu
please reffer to NIT
2 documents required · 2 mandatory
₹1,000
Yes
Executive Engineer PWD RandB Electric Div Jammu
₹1.4 L
Yes
7 Feb 2020
23 Jan 2020
1 Feb 2020
24 Jan 2020
31 Jan 2020
24 Jan 2020
Amount
Supply, installation,testing & Commissioning of Variable Refregerant volume modular type Air conditioning system suitable for heating and cooling by using invertor driven /digital scroll compressors complete with indoor and outdoor units with indidual controller and with fittings etc as per quantity given below including full charging of R410A refregerant gas complete as per specifications and directions of Engineer -in -Charge at site . Air Cooled VRV/VRF Units with Scroll Compressor with invertor technology shall be capable of modulating capacity , works on (R410A) with heating cooling both mode.The units shall be factory charged.The outdoor units shall be a factory assembled unit housed in a strudy weather proof casing constructed from rustproofed mild steel panels coated with powder coated finish.The out door units shall have multiple scroll compressors and be able to operate even in case of breakdown of one compressor.Each ODU should have minimum 1 novariable compressor & an oil separator to ensure stable operation with long refrigerant piping Make:-Diakin/O-general/ Mitshubishi heavy duty/Carrier/Blue Star/Hitachi. or equivalent.
ODU - 28 HP
ODU - 24 HP
Supply, installtion,testing & commissioning of Split Indoor Units(Nominal Capacity) Wall Mounted Type Unit - 1.6 TR
Supply, installtion,testing & commissioning of Round Flow Type cassette units with builtin drain pump with decorative panel(Nominal Capacity)
Round Flow Cassette Type Unit - 4.0 TR
Round Flow Cassette Type Unit - 2.0 TR
Supply, installtion,testing & commissioning of Split Ducted units with builtin drain pump with decorative panel(Nominal Capacity)
High Static Duct Type Unit - 5.5 TR
High Static Duct Type Unit - 4.5 TR
High Static Duct Type Unit - 4.0 TR
Remote Controller Installation , testing and commissioning of corded remote controller suitable for Indoor units and suitable to work on single phase 230 volt (+)(-) 10% 50 Hz AC supply.
Refrigerant Joints/ Headers Installation , testing and commissioning of imported Y-joints fittings and header to all indoor units at all floors including alignments of joints complete as required.
Refrigerant Piping Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported /fixed with suitable size of clamps /M.S hanger and all exterinal /exposed to sun piping shall run in M.S.painted cable tray with cover at site.
41.2 mm O.D. (insulation : 19mm)
38.1mm O.D. (insulation : 19mm)
34.9 mm O.D. (insulation : 19mm)
28.6 mm O.D. (insulation : 19 mm)
22.2 mm O.D. (insulation : 13 mm)
19.1 mm O.D. (insulation : 13 mm)
15.9 mm O.D. (insulation : 13 mm)
12.7 mm O.D. (insulation :13 mm)
9.53mm O.D. (insulation : 13 mm)
6.4 mm O.D. (insulation : 13 mm)
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
Drain Piping Providing and fixing rigid CPVC piping complete with fittings, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
32 mm dia
Ducting Providing, fixing, testing and commissioning of sheet metal ducting complete with support, dampers etc
0.50mm (26 Gauge)
0.63mm (24Gauge)
Insulation Providing, fixing & Commissioning closed cell nitrile rubber/ chemically crossed linked XLPE insulation on duct.
Duct Acoustic Lining Providing & fixing of duct acoustic lining with fiber glass insulation of density 30kg/m3 covered with 26GI perforated sheet with nuts & bolts 13mm thick
Grilles Providing and fixing of duct accoustic lining as per specifications and drawings.
Al Extruded supply air grille with damper
Al Extruded return air grille with out damper
Control & Transmission Wiring Providing & fixing control wiring of 2 core x 1.5 sqmm copper in PVC conduit pipe of 25mm dia including providing & fixing support @1.5mt distance C/C where it is not recessed between indoor units and their wired remote.
Fabrication, supplying, installation testing and commissioning of following pannel CPRI approved made out of 2mm thick M.S. sheet, floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly p0wder coated with provision for fixing of 1 no incomer MCCB, outgoing MCB's, , required number of sets of Aluminium Bus Bar, providing & fixing . strips for housing MCB's and other allied accessories etc. as required. (Make as per annexure). Main and Sub main Panel = 25Cft.(APPROX)
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
MCCB FP 400 Amp. 36 KA Microprocessor type (main incomer) complete with spreader links. All MCCB's shall have rotary handle and ICU=ICS =100%.
MCCB FP 40 Amp. 25 KA
Aluminium Bus Bar suitable for 500 Amp. 4 Strips of suitable length
CT Set of suitable rating 200/5 A 1.15 VA burden
Indicating Lamp(Led Type)
Voltmeter (0-500) Volts Digital type
Ammeter (0-500) Amps. Digital type
MCB Strip for 12 Nos. MCB's
Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required.
MCCB FP 160 Amp. 36 KA Microprocessor type complete with spreader links All MCCB's shall have rotary handle and ICU=ICS =100%.
Aluminium Bus Bar suitable for 300 Amp. 4 Strips of suitable length
CT Set of suitable rating
Indicating Lamp(Led Type)
Voltmeter (0-500) Volts Digital type
Ammeter (0-500) Amps. Digital type
MCB Strip for 12 Nos. MCB's
MCB SPN 40 AMP 10KA C-SERIES
Supplying and fixing following rating, double pole, 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, installation, testing & commissioning of CPRI Approved maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly and providing and laying of 2 Nos. 25 x 3 mm copper strip from copper rod upto the main panel. The earthing pit should be covered with PVC cover.
Supply, installation, testing & commissioning CPRI Approvedof GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be pre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly and having ROHS certification GI Electrode Earthing should be maintinance free and does not require regular manual addition of water GI Electrode and providing and laying of 2 Nos. of 25 x 5 mm G.I strip from G.I rod upto the panel. The earthing pit should be covered with PVC cover.
Supply and laying of 1.1kV grade , XLPE insulated, Aluminium conductor, Heavy Duty , Armoured cables of ratings 3.5 x150sqmm as per IS : 7098 Part-1 with latest amendments. The cable shall be laid on wall duly clamped/cable tray and in G.I Pipe under road as required.
Power wiring in PVC conduit of 3C x 2.5MM sq for each IDU from main panel to IDU
Supply, Installation, Testing and commissioning of 300kVA Automatic Servo Voltage Stabilizer oil cooled, outdoor type, suitable for operation on 3 phase 50Hz, 415V system with input voltage correction range of 160V to 460V, output 415V +/-1%, unbalanced input , unbalanced load, first filling of oil, overvoltage, undervoltage, overcurrent, short ciruit, protections and complete with by pass system. The servo shall be CPRI TESTED and certificate of test report shall be submitte to the department.
Supply, Installation of ABC type Fire extinguishers 6kg , wall mounted of approved makes Safex/Ceasefire/
CAMC for 1 year after Defect liability period of 1 years.
CAMC for 2 year after Defect liability period of 1 years
TS Sales Corporation
Yatha Consultants and Engineers
M/S GLOBUS POWER SYSTEMS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .