Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAccepted-AOC D 154 D 154 GROUND FLOOR INDUSTRIAL ESTATE PHASE VII MOHALL | ₹3.9 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹4.7 Cr+₹76.6 L (19.6%)Rejected-AOC PLOT NO 3821 PHASE IV GIDC VATVA VATVA AHMEDABAD GUJARAT 382445 | AHMADABAD | GUJARAT | 382445 | ₹4.7 Cr+₹76.6 L (19.6%) | L2 | Rejected-AOC rejected |
Tender Value
₹4.1 Cr
EMD Value
₹8.1 L
Closing Date
30 Sept 2023, 9:00 amClosed
Executive Engineer Kandi Canal Stage-2 Division, W
Executive Engineer Kandi Canal Stage-2 Division, WRD Punjab, Hoshiarpur
Supply and Installation of 8 Nos. Pumps with all related Electrical Mechanical equipments for Pump house of Bhaddi Lift Irrigation Scheme off taking at R.D 129.000 km of Kandi Canal Stage-2
2023_WR_108882_1
54
Open Tender
Electrical Works
Item Rate
180 days
Hoshairpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
₹8.1 L
Yes
Executive Engineer Kandi Canal Stage-2 Division, W
13 Sept 2024
9 Sept 2023
30 Sept 2023
9 Sept 2023
30 Sept 2023
9 Sept 2023
19 Sept 2023
Amount
Supply, installation, testing & commissioning of VERTICAL SUBMERSIBLE POLDER TYPE PUMPS of 65 LPS / 3900 LPM capacity at total head of 63 m along with submersible motor and allied accessories of required capacity (not less than 100 HP) commensurate to the capacity of the pump complete in all respects as per detailed specification given in the bid document (3 Working & 1 Standby)
Supply, installation, testing & commissioning of VERTICAL SUBMERSIBLE POLDER TYPE PUMPS of 27 LPS / 1620 LPM capacity at total head of 82 m along with submersible motor and allied accessories of required capacity (not less than 60 HP) commensurate to the capacity of the pump complete in all respects as per detailed specification given in the bid document (3 Working & 1 Standby)
Supply, Installation, testing & commissioning of Single Unit Control Panel with Interlocking system between both incomer ACB’s and consisting of 8 starter panel for 4 Nos. Item 1 + 4 Nos. Item 2 submersible pump sets mentioned above starting with soft-starter comprising of the following:
(3) INCOMING SUPPLY FROM TRANSFORMER
(3) INCOMING SUPPLY FROM SOLAR PV PLANT
(3) OUTGOING FEEDERS
(3) 250 KVAR CAPACITOR BANK
(3) All enclosed in one single unit as per drawing and technical specifications in the section X of the Bid document complete in all respects
Providing and fixing of 3 core copper submersible cable for polder pump of suitable size and the capacity of the cable shall be 1 ½ times than the normal capacity to save it from becoming hot and for longer life usage. It shall also have required number of cable clips and shall be as per IS:694 with latest amendments
Providing and fixing of junction box near to sump wall for connection of pumps of suitable size as per site requirement and to satisfaction of Engineer in charge
Providing and fixing of Aluminium single core armoured cable of 800 sq. mm from Transformer to Incomer ACB of control panel and should be laid in underground trench not less than 1.5 m depth as per norms of PSPCL
Providing and fixing of Aluminium armoured cable of 120 sq. mm 3.5 core from control panel to junction box and should be laid in underground trench not less than 1.5 m depth as per norms of PSPCL
Providing and fixing of MS ‘C’ Class – 200mm dia. ERW type column pipe with both ends of pipes fitted with screwed steel flanges duly welded after screwing with pipes. The thickness of pipe should be confirming to IS 1978-1982 with latest amendments suitable increaser shall be provided with the pump set.
Providing and fixing of common header of 400mm dia. electrically welded steel pipe confirming to IS:3589 with latest amendments for connection of delivery of pumps from sump and fitted as per site requirements complete as shown in attached drawing consisting of 1 No. 400mm D/F MS Bend 90 deg; 1 No. 400mm Sluice Valve PN 10; 1 No. 400mm Non-Return Valve PN 10; MS fabricated Tee 4Nos. 400 x 400 x 200; 1 No. 1.25” socket for Pressure Gauge; 1 No. A/F Tee of 400 X 400 X 100 size and nuts-bolts, gaskets and flanges.
Providing and fixing of common header of 300mm dia. electrically welded steel pipe confirming to IS:3589 with latest amendments for connection of delivery of pumps from sump and fitted as per site requirements complete as shown in attached drawing consisting of 1 No. 300mm D/F MS Bend 90 deg; 1 No. 300mm Sluice Valve PN 10; 1 No. 300mm Non-Return Valve PN 10; MS fabricated Tee 4Nos. 300x 300x 200; 1 No. 1.25” socket for Pressure Gauge; 1 No. A/F Tee of 300 X 300 X 100 size and nuts-bolts, gaskets and flanges.
Providing and fixing of double flanged D.I Sluice valve 8” (200 mm) I/D for delivery line (PN 1.6) complete in all respects. Make: AVK/ IVC / SEEREX /VAG/TCX/Kirloskar
Providing and fixing of double flanged D.I Non-Return valve 8” (200 mm) I/D for delivery line (PN 1.6) complete in all respects. Make: AVK/ IVC / SEEREX /VAG/TCX/Kirloskar.
Providing and fixing of double flanged MS Bend (any degree) 8” (200 mm) I/D for outlet from pump and column ends complete in all respects.
Providing and fixing of D.I. Air Release valve 4” (100 mm) PN 1.6 fitted with flanged connection as per ISI specification on delivery line of common header complete in all respects
Providing, fixing of Maintanance free (Chemical) Earthing with all the allied Material for LT feeder Panel, Tranformer, Genset, VCB, NGR, Busbar Box etc.
Providing and fixing of GI earthing Strip 50 mm x 5 mm clamped/recessed to ground/wall
Providing and fixing of monorail straight travelling trolley including chain pulley block provided with girders having lift up to 12 m, which shall be as per site requirement to take load up to 3 tons
Providing and fixing of M.S. clamps of suitable size to 200 mm dia. Pipe for erection and dismantling of pumps (one pair = two halves) complete in all respect as per specifications
Providing, fixing and commissioning of S.S Pressure Gauge 150 mm dia. of 10 Kg/cm2 glycerin filled with needle valve shall be supplied
Providing & fixing of Electro-magnetic Flowmeter of rated size on pipeline for raw water with fixed/ wall mounted display including wiring complete in all respect; Make: ABB/Siemens/Nivo /Fedral/Forbes Marshall. 400 mm
Providing & fixing of Electro-magnetic Flowmeter of rated size on pipeline for raw water with fixed/ wall mounted display including wiring complete in all respect; Make: ABB/Siemens/Nivo /Fedral/Forbes Marshall. 300 mm
Transformer 800 KVA Supplying, installing, testing and commissioning of 3 phase 50 Hz oil immersed naturally cooled outdoor type copper wound 11/0.433 kV Transformer as per IS:2025 with off load tap changer, Buchholz relay, radiator assembly, silicone gel breather, terminal arrangement, cable box complete in all respect as per as DNIT specification,
Supplying, installing, testing and commissioning of 11 kV Grade earthed cable of XLPE insulated aluminium conductor (Armoured) of following size as per the specification given in as per IS specification Make: Havells, ICL, CCI,KEI, PolyCab 11 kV Line (G.O Switch) to VCB: 3 core 70 sq. mm HT
Supplying, installing, testing and commissioning of 11 kV Grade earthed cable of XLPE insulated aluminium conductor (Armoured) of following size as per the specification given in as per IS specification
NGR panel for transformer made with sheet steel clad free standing, floor mounted, dust & vermin proof indoor/outdoor type NGR panel manufacturing out of 2mm thick CRCA sheet steel and powder coated with RAL-7032 Siemens grey shade. The panel will have the following component fully bus bared, wired and ready to use. Set punched stainless steel resistors manufactured out of ASTM-A 240-304 grade stainless steel assembled in the form of banks as per DNIT specifications
Providing & fixing H Pole structure having steel tubular poles 2 nos., 10 mtrs long, 168 Kg design 410 sp-44 conforming to IS 2713 part-I, incl. excavation, RCC muff 10” dia 2 meter length of each pole, with C.C.1:4:8, M.S Channel 100X50X6mm (27RFT), M.S Angle 50X50X6mm (30FT), 50X6mm (18RFT), Primer painting complete structure, 11 kV GO Switch with 9 nos. pins, on/off arrangement, lighting arrestors 93 nos. GI pipe earthing 2 nos. 11 kV Fuse wire, making holes in pole, nut and bolts for fixing channels, angles, GI protection pipe, 50 mm 5mtr with clamps, nut and bolts, danger plate with clamps, complete in all respects as per DNIT specifications
Supplying, erection, testing and commissioning of battery bank & battery charger 24V DC Supply capacity of 2 volt, 80 AH lead acid cell, maintenance free type tubular storage battery along with associated accessories, Float cum boost charges 10/16 Amp. Rating and DCDB as per DNIT specifications
Supplying, erection, testing and commissioning of HT kit of cable and joints suitable for HT Cables type Heat shrinking 3 core XLPE cable with required thimbles of same size. The joint should be strictly as per relevant ISI specifications as per DNIT specifications
25) Construction of RCC M25 foundation as per drawing and design to be submitted by the firm for approval by department for the following:
(A) Transformer
(B) H.T. Panel
Providing and Fixing of 4 No. Fire Extinguishers each of 5 Kg capacity CO2 type ISI mark fire extinguisher complete with pressure gauge cylinder and set of 4 No. sand buckets including M.S. stand complete in all respects including painting with red paint, shock treatment guidelines chart as per as DNIT specification
Supplying and fixing of nominal 2.5mm±10% thick fire retardant mats conforming to IS:15652 and meeting the requirement of IS 5216, IS 8437, IEC 479 Pub-I along with suitable adhesive/chemibound resin water proof compound and sealing material as per in service recommendations class-C of IS:15652 and suitable for class A up to 3.3 kV installations as per DNIT specification
Construction of Gravel Yard with fencing as per PSPCL norms
Construction of Grill/gratings/trench covers as per drawing and design to be submitted by the firm for approval by department
Construction of Thrust Blocks on each pump delivery outlet as per drawing and design to be submitted by the firm for approval by department
Providing and Fixing of Level switch in sump with complete wiring and automation/interlocking with panel with WLC
Campus Lighting at site every 10 m as per standard norms. Provision of manual changeover of suitable rating for shifting lighting load/24V DC VCB Battery charger to DG in case of grid power failure (1 Light pole)
Supply, erection, testing and commissioning of 15 KVA capacity silent type water cooled Diesel Gen set including installation/commissioning cost of suitable capacity inbuilt diesel tank, AVM pad with 1 No. industrial silencer, AMF panel, charger and suitable size battery for handling the lightening load at site.
Supply, erection, testing and commissioning of DI flow control Plunger/ needle valve cum regulator valve gear mounted of 800 MM size pressure control valve should work as pressure reducing valve of a higher upstream pressure to constant downstream pressure independent of capacity or flow variation of the upstream .control valve is of through passage design rotationally symmetric flow path annular flow cross section in any open position with linear regulating characteristics axial movement of the plunger is by means of shaft driven with irreversible worm gear box incl position indicator , face to face dimensions as per DIN 3202, F% and flange connection as per DIN 2501-1 along with dismantling joint on the intake point at RD 129.035 km including excavation and fixing of valve at existing HDPE pipe t to maintain required flow required at the sump and required flow and pressure at downstream along with 3 Year DLB
Supply, erection, testing and commissioning of DI Gate valve gear mounted of size 800 MM PN 1.6 along with dismantling joint on the intake point at RD 129.035 km including excavation and fixing of valve at existing HDPE pipe along with the accessories fabricated from 8 mm thick MS sheet towards intake of sump
Supply, erection, testing and commissioning of MS sheet fabricated pipe 400mm dia. of 8mm th plate from header to the rising main including excavation and realigning to the requirement upto 1 meter depth as per site requirement complete in all respect
Supply, erection, testing and commissioning of MS sheet fabricated pipe 300mm dia of 8mm th plate from header to the rising main including excavation and realigning to the requirement upto 1 meter depth as per site requirement complete in all respect
Supply, erection, testing and commissioning of MS sheet fabricated pipe 800mm dia of 8mm th plate from header to the rising main including excavation and realigning to the requirement upto 1 meter depth as per site requirement complete in all respect
Supply, erection, testing and commissioning of Sump dewatering pump for cleaning of sludge in the sump of 2 HP Submersible type including panel and wire and 1.5 " GI pipe to the nearest disposal point upto 20 meters as per site requirement complete in all respect
Providing and fixing of D.I. Air Release valve 8” (200 mm) PN 1.6 fitted with flanged connection as per ISI specification on input 800 mm line towards sump complete in all respects
Supply, erection, testing and commissioning of solar PV plant of 175 KW (as per site plan drawing shown with annexures) on NET metering bases on rooftop. The design of Solar plant to be vetted by PEDA or Reputed approval authority before execution at site as per MNRE specificationsSupply, erection of civil MS fabricated structures for upto 3 m height for Solar plant at item 41 from ground inside Pump house complex complete in all respect.
Any Other item
Aqua Machineries Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .