| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | ₹15.0 L | L1 | Accepted-AOC QUALIFIED FOR AOC |
Tender Value
₹16.3 L
EMD Value
₹12,210
Closing Date
30 Jan 2026, 5:30 pmClosed
COMMISSIONER OF UJJAIN MUNICIPAL CORPORATION
CHATRAPATI SHIVAJI BHAWAN, AGAR ROAD UJJAIN
CONSTRUCTION OF CC ROAD AND DRAIN AT PANCHAMPURA IN WARD 50
2025_UAD_471962_1
250/ZONE4/E-TENDER/2025
Open Tender
Civil Works - Others
Percentage
90 days
AT PANCHAMPURA IN WARD 50
PLEASE REFER TENDER DOCUMENT
4 documents required · 4 mandatory
₹2,000
₹12,210
8 Jul 2026
31 Dec 2025
2 Feb 2026
31 Dec 2025
30 Jan 2026
31 Dec 2025
DISMANTLING STONE SLAB FLOORING LAID IN CEMENT MORTAR INCLUDING STACKING OF SERVICEABLE MATERIAL AND DISPOSAL OF UNSERVICEABLE MATER IAL WITHIN 50 METERS LEAD.
Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead upto 1000m as per relevent clauses of
CONSTRUCTION OF GRANULAR SUB-BASE BY PROVIDING COARSE GRADED MATERIAL (CBR>30), SPREADING IN UNIFORM LAYERS WITH MOTOR GRADER ON PR EPARED SURFACE, MIXING BY MIX IN PLACE METHOD AT OMC AND COMPACTING WITH VIBRATORY ROLLER OF 80-100 KN STATIC WEIGHT TO ACHIEVE THE DESIRED DENSITY, COMPLETE IN ALL RESPECT AS PER RELEVANT CLAUSES OF
PROVIDING AND LAYING CEMENT CONCRETE GRADE M-10 NOMINAL MIX 1:3:6 WITH 40 MM GRADED CRUSHED STONE AGGREGATE, SPREADING THE CONCRETE BY SHOVELS MIXING SHALL BE IN MECHANICAL MIXER, COMPACTING BY USE OF PIN/PLATE/SCREED VIBRATORS INCLUDING FORM WORK BY STRONG STEEL GIRDERS FIXED BY
PROVIDING AND LAYING CEMENT CONCRETE GRADE M-20 (NOMINAL MIX 1:1.5:3) WITH 20 MM GRADED CRUSHED STONE AGGREGATE, MIXING SHALL BE IN MECHANICAL MIXER, LAYING WITH PAVER COMPACTING BY USE OF PIN, PLATE / SCREED VIBRATORS INCLUDING FORM WORK BY STRONG STEEL GIRDERS FIXED BY SPIKES, SEPARATION MEMBRANE 125 MICRON THICK, I/C CUTTING OF JOINTS @ 4 TO 5 M INTERVAL & FILLING IT WITH HOT APPLIED BITUM INOUS SEALANT (WITHOUT DOWEL BARS). (MAX.
exvation work with 05KM Extra lead
MOORUM/HARD COPRA- "SUPPLYING AND FILLING IN PLINTH UNDER FLOORS INCLUDING, WATERING, RAMMING CONSOLIDATING AND DRESSING COMPLETE."
CRUSHER STONE DUST- "SUPPLYING AND FILLING IN PLINTH UNDER FLOORS INCLUDING, WATERING, RAMMING CONSOLIDATING AND DRESSING COMPLETE."
CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE- PROVIDING AND LAYING IN POSITION CEMENT CONCRETE OF SPECIFIED GRADE EXCLUDING THE COST OF CENTERING AND SHUTTERING ALL WORK UP
THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE)- "REINFORCEMENT FOR R.C.C. WORK INCLUDING STRAIGHTENING, CUTTING, BENDING, PLACI NG IN POSITION AND BINDING UPTO FLOOR LEVEL INCLUDING COST OF BINDING WIRE, WASTAGE AND OVER LAPS UPTO 12MM HORIZONTAL/ INCLINED POS ITION OF REINFORCEMENT BARS IN SLAB AND BEAMS, PLINTH, CHAJJAS, LINTELS, UPTO 4.5M VERTICAL LENGTH OF REINFORCEMENT IN WALL COLUMNS (OVER LAPS SHALL BE PROVIDED AS PER REQUIREMENT OF IS : 13920; IS 456 & SP : 34) ETC. COMPLETE."
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE.- "PROVIDING AND LAYING IN POSITION SPECIFIED GRA DE OF REINFORCED CEMENT CONCRETE EXCLUDING THE COST OF CENTERING, SHUTTERING, FINISHING AND REINFORCEMENT - ALL WORK UP TO PLINTH LE
WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, BUTTERESSES, PLINTH AND STRING COURSES ETC"- "CENTERING AND SHUTTERING INCLUDING STRUTTING, PROPPING STRETCHING ETC. COMPLETE FOR AND REMOVAL OF FORM WORK BY SHEET PLATE OR PLY
CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE.
PROVIDING AND FIXING 40MM THICK RED STONE SLAB OVER DRAINS INCLUDING POINTING IN CEMENT MORTAR 1:3 (1 CEMENT : 3 SAND)
IN GRATINGS, FRAMES, GUARD BAR, LADDER, RAILINGS, BRACKETS, GATES AND SIMILAR WORKS."- "PROVIDING AND FIXING M.S. TUBULAR FRAMES FOR DOORS, WINDOWS, VENTILATORS AND CUPBOARD WITH ANY SECTION MADE OF 1.60MM OR 1.25MM THICK M.S. SHEET, JOINTS MITRED AND WELDED AND G RINDED FINISH WITH PROFILES REQUIRED SIZE WITH 15X3MM LUGS 10CM LONG EMBEDDED IN CEMENT CONCRETE M-10 (NOMINAL MIX WITH 20MM MAXIMUM SIZE OF STONE AGGREGATE) BLOCKS 15X10X10CM OR WITH WOODEN PLUGS AND SCREWS OR RAWL PLUGS AND SCREWS OR WITH FIXING CLIPS OR WITH BO LTS AND NUTS AS REQUIRED INCLUDING FIXING OF NECESSARY BUTT HINGES AND SCREWS AND APPLYING A PRIMING COAT OF APPROVED STEEL PRIMERS. 1. STEEL WORK WELDED IN BUILT UP SECTIONS/ FRAMED WORK INCLUDING CUTTING, HOISTING, FIXING IN POSITION AND APPLYING A PRIMING COAT OF APPROVED STEEL PRIMER
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
tender.pdf
Tender Documents • 1.85 MB
BOQ_554949.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .