Loading…
Loading…
Tender Value
₹71.1 L
EMD Value
₹1.4 L
Closing Date
10 Apr 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
45 days
Expenditure
Revenue
GENERAL
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Other terms and conditions shall follow clause-10 of GCC, April 2022 and Advance Correction Slip No.1 of GCC, April 2022 Note: No Technical & Financial credential are required for tenders having advertised value up to Rs. 50 Lakh
Definition Of Similar Work : - AMC/CAMC/Repairing/Manning /Overhuling of AC Package Units/Centralised AC plants.
27 conditions · 5 needing a document upload
Documents to be uploaded only in the website by the Tenderer Following Annexures duly filled and signed are to be uploaded online only prior to Closing of Tender. Original copy of all the documents to be submitted to office within 7 days whenever demanded by the Railway. Otherwise, Railway reserves rights to Reject/Accept such tender/offer without any reference to the tenderer/tenderers. Annexures are available at Upload/View Document menu in Home Page of IREPS portal for works tender.
The details of the works completed by the tenderer during the last three years to be filled in Annexure-I(a) & Details of contractual payment received by the Tenderer during the last 3 (three) financial years including the current financial year to be filled & submitted in Annexure-I(b).
The details of Plants and Machinery with the tenderer to be filled in Annexure- II.
Details of Personnel and Organization of the Tenderer to be filled in Annexure-III.
Details of Works presently on hand of the Tenderer to be filled in Annexure- IV.
The details regarding Association of Railway Officer s with the tenderer to be filled in Annexure- V.
List of the Arbitration cases of the Tenderer during last Five years to be filled in Annexure-VI.
List of the Court cases of the Tenderer during last Five years to be filled in Annexure- VII.
NEFT MANDATE FORM. All Payments to the agency including the refund of the Earnest Money of the unsuccessful bidder preferably will be remitted through NEFT. The Tenderer is required to submit Bank details and A/C No. etc. in Annexure- VIII.
Documents to be uploaded in the website by the Tenderer : Online payments have been made and no documents are to be deposited.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer shall upload scanned copy of valid PAN and GSTIN in PDF format.
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII and VIII respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.Otherwise, Railway reserves rights to Reject/Accept such tender/offer without any reference to the tenderer/tenderer's.
Annexure:- IV, V , VI, VII and VIII.
Annual Corrective Maintenance Contract(ACMC) of RMPU (Roof Mounted Package Unit)(Make- Lloyds/Sidwal/Intech/Amit/Daulatram/SSK/Leel Elect.) in AC Coaches(LHB & ICF)at ASN DIVN for TWO(02)years.
EL-04-26
EL-04-26
Open
Works - General
24 Months
Paschim Bardhaman, West Bengal
₹0
₹1.4 L
10 Apr 2026
18 Mar 2026
27 Mar 2026
179 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 71,12,113.16 | ||
| — | 12.00 | — | — | ||
| Price for supply of new scroll compressor ZR-61KC-2TFD-523 as per RDSO specification including drier similar to SR-075-1040 of Sidwal. | — | — | — | 5,46,930 | |
| — | 12.00 | — | — | ||
| Price for removal of defective Compressor and re-fitment with new one including drier. (all types of gas & vacuum pump reqd. will be supplied by firm). (Defective to be returned to Sr.SE/TL&AC/ASN's store) | — | — | — | 1,09,386 | |
| — | 12.00 | — | — | ||
| Price for supply of new blower motor 1.5 HP 1400 RPM with TOP (Make-RDSO approved source) similar to SR-075-1027 of Sidwal. | — | — | — | 1,91,691.84 | |
| — | 12.00 | — | — | ||
| Price for removal of defective blower motor and fitment with new one with released blower runner (A+B) (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 30,471.84 | |
| — | 12.00 | — | — | ||
| Price for supply of new condenser fan motor 1 HP/1400 RPM with TOP (RDSO approved source)similar to SR-075-1028 of Sidwal. | — | — | — | 1,82,978.64 | |
| — | 12.00 | — | — | ||
| Price for removal of defective condenser fan motor and fitment of new one with TOP & released fan blade. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 30,471.84 | |
| — | 20.00 | — | — | ||
| Price for supply of new plastic fan with aluminium hub similar to(SR-075-1036) of Sidwal. | — | — | — | 1,59,743 | |
| — | 20.00 | — | — | ||
| Price for removal of defective plastic fan with aluminium hub. (Defective to be returned to Sr.SE /TL/AC/ASN's store). | — | — | — | 48,616 | |
| — | 6.00 | — | — | ||
| Price for supply of new SS welded round guard, similar to(SR-075-1041)of Sidwal of condenser fan motor. | — | — | — | 18,751.8 | |
| — | 6.00 | — | — | ||
| Price for removal of defective SS welded round guard and re-fitment with new one in condenser fan motor. (Defective to be retuned to Sr.SE/AC&TL/ASN's store). | — | — | — | 6,875.64 | |
| — | 50.00 | — | — | ||
| Price for supply of N2 Gas, refrigerant R-407 or R-22 for the leak testing | — | — | — | 2,51,978.5 | |
| — | 50.00 | — | — | ||
| Price for Leak test of system, rectification, flushing the system with N2 Gas and charging of refrigerant 407 or R-22. (Vacuum pump supplied by Firm). | — | — | — | 1,62,776 | |
| — | 15.00 | — | — | ||
| Price for supply & removal of defective Drier filter (1/2" Solder type)similar to SR-075- 1019 of Sidwal and re-fitment by new one. (all associated jobs e.g. brazing, leak testing etc. along with all type of gas & vacuum pump reqd. will be supplied by firm). | — | — | — | 1,46,759.55 | |
| — | 12.00 | — | — | ||
| Price for supply of new Hartige (Couplers) connector 24 pin similar to SR-075-1001 of Sidwal. | — | — | — | 1,25,012.52 | |
| — | 12.00 | — | — | ||
| Price for removal of defective / damage Hartige (Couplers) connector 24 pin and re- fitment with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 34,378.32 | |
| — | 6.00 | — | — | ||
| Price for supply of new Hartige (Coupler) connector 16 pin similar to SR-075-1002 of Sidwal. | — | — | — | 54,693 | |
| — | 6.00 | — | — | ||
| Price for removal of defective / damage Hartige (Couplers) connector 16 pin and re- fitment with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 15,235.92 | |
| — | 4.00 | — | — | ||
| Price for supply of new Dumper Actuator similar to SR-075-1046 of Sidwal. | — | — | — | 29,518.32 | |
| — | 4.00 | — | — | ||
| Price for removal of defective / damage Dumper Actuator and replacement with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 7,472.68 | |
| — | 4.00 | — | — | ||
| Price for supply of new male-female plug and socket for dumper actuator similar to SR-075-1046 of Sidwal. | — | — | — | 4,879.04 | |
| — | 4.00 | — | — | ||
| Price for removal of defective / damage plug & socket for Dumper Actuator and replacement with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 4,107.24 | |
| — | 10.00 | — | — | ||
| Price for supply of new Pressure Transmitter similar to(0-10 bar SR-075-1010) of Sidwal. | — | — | — | 1,16,548.2 | |
| — | 10.00 | — | — | ||
| Price for removal of defective Pressure Transmitter and replacement with new one similar to SR-075-1010 of Sidwal. (all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 28,648.6 | |
| — | 10.00 | — | — | ||
| Price for supply of new Pressure Transmitter similar to(0-40 bar SR-075-1011)of Sidwal. | — | — | — | 1,16,548.2 | |
| — | 10.00 | — | — | ||
| Price for removal of defective Pressure Transmitter (0-40bar) and replacement with new one similar to SR-075-1011 of Sidwal. (all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 28,648.6 | |
| — | 40.00 | — | — | ||
| Price for supply of protection for heater (OHP), similar to spare parts of LHB Type Air Conditioner as per EDTS-075 of Sidwal. | — | — | — | 80,736.8 | |
| — | 40.00 | — | — | ||
| Price for removal of defective protection for heater (OHP) and replacement with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 1,55,571.2 | |
| — | 50.00 | — | — | ||
| Price for supply of new glass bulb Cartridge + 130 degree and replacement by new similar to SR-075-1015 of Sidwal. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 61,718.5 | |
| — | 5.00 | — | — | ||
| Price for supply of new ESTI switch assembly with cartridge similar to SR-075-1014 of Sidwal. | — | — | — | 94,193.5 | |
| — | 5.00 | — | — | ||
| Price for removal of defective ESTI switch assembly with cartridge replacement by new complete assembly similar to spare parts of LHB Type Air Conditioner as per EDTS-075 of Sidwal. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 19,750.25 | |
| — | 12.00 | — | — | ||
| Price for supply of new Air heater set consisting 400W (15 Nos.) coil with insulated backalite sheet. | — | — | — | 13,592.76 | |
| — | 12.00 | — | — | ||
| Price for removal of defective Air heater set replacement by new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 25,783.92 | |
| — | 15.00 | — | — | ||
| Price for supply of new Low Pressure control switch (auto-reset) similar to SR-075- 1037 of Sidwal. | — | — | — | 63,808.5 | |
| — | 15.00 | — | — | ||
| Price for removal of defective Low Pressure control switch (auto-reset) & replacement by new one similar to SR-075-1037 of Sidwal. (all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm. (Alco make to Alco make and Danfoss make to Alco make). Danfoss make-KP-1/Alco make PS3-AP3 HNK4/1.5B. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 51,640.5 | |
| — | 15.00 | — | — | ||
| Price for supply of new High pressure control switch (auto-reset). similar to SR-075- 1038 of Sidwal (Alco make to Alco make and Danfoss make to Alco make). Danfoss make-KP-5/Alco make PS3-WP HNK27/21. | — | — | — | 54,693 | |
| — | 15.00 | — | — | ||
| Price for removal of defective High pressure control switch (auto-reset) and replacement by new one. (all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm). (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 51,640.95 | |
| — | 20.00 | — | — | ||
| Price for supply of new Control pressure switch (auto-reset) (Alco make to Alco make and Danfoss make to Alco make) Danfoss make-KP-5/Alco make-PS3-A4P HNK23/20 +/-0.3 bar. | — | — | — | 78,751.8 | |
| — | 20.00 | — | — | ||
| Price for removal of defective Control pressure switch (auto-reset) and replacement by new one. (all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm). (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 61,933.2 | |
| — | 12.00 | — | — | ||
| Price for supply of new Expansion Valve and re-fitment by new one after removing similar to SR-075-1039 of Sidwal . (all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm). (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 1,89,602.4 | |
| — | 12.00 | — | — | ||
| Price for supply of new Liquid level cum moisture indicator, similar to SR-075-1021 of Sidwal. | — | — | — | 18,751.8 | |
| — | 12.00 | — | — | ||
| Price removal of defective Liquid level cum moisture indicator and re-fitment with new one similar to SR-075-1021 of Sidwal.(all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm). (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 32,936.16 | |
| — | 2.00 | — | — | ||
| Price for supply of new Evaporator coil - similar to Left hand SR-075-1042/Right hand - SR-075-1043 of Sidwal. | — | — | — | 1,33,694 | |
| — | 2.00 | — | — | ||
| Price for removal of defective Evaporator coil - Left hand/Right hand and & replacement with new one as required. (all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm). (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 29,950.92 | |
| — | 2.00 | — | — | ||
| Price for supply of new Condenser coil- similar to Left hand SR-075-1044/Right hand SR-075-1045 of Sidwal. | — | — | — | 1,62,874.18 | |
| — | 2.00 | — | — | ||
| Price for removal of defective Condenser coil- similar to Left hand SR-075-1044/Right hand SR-075-1045 of Sidwal & fitment with new one as required. (all associated jobs e.g. brazing, leak testing etc. along with all types of gas & vacuum pump reqd. will be supplied by firm). (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 29,950.92 | |
| — | 6.00 | — | — | ||
| Price for supply & replacement of HP gauge (0 to 40 bar) similar to SR-075-1053 of Sidwal with new one. | — | — | — | 94,103.22 | |
| — | 6.00 | — | — | ||
| Price for supply & replacement of LP gauge (0 to 10 bar) similar to SR-075-1052 of Sidwal with new one. | — | — | — | 94,103.22 | |
| — | 10.00 | — | — | ||
| Price for supply of new Rotary switch of AC "Off-On" similar to SR-075-1048 of Sidwal. | — | — | — | 14,975.4 | |
| — | 10.00 | — | — | ||
| Price for removal of defective Rotary switch of AC "Off-On" & re-fitment with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 8,464.4 | |
| — | 10.00 | — | — | ||
| Price for removal of defective Selector switch for pressure gauge meter for four no. compressor similar to SR-075-1050 of Sidwal and fitment with new one. (Defective to be returned to Sr. SEE/TL&AC/ASN's store) | — | — | — | 19,169.2 | |
| — | 6.00 | — | — | ||
| Price for removal and replacement of defective Hygrostat 35-100%. similar to SR-075- 1022 of Sidwal with new one. | — | — | — | 80,226 | |
| — | 8.00 | — | — | ||
| Price for supply of new Temperature Sensor FA similar to SR-075-1059 of Sidwal. | — | — | — | 65,366 | |
| — | 24.00 | — | — | ||
| Price for supply of new compressor contactor Type-LS1BK00DC110V With or TAL 40- 30 01+RT5/100 CAS - 22M, RDSO/RCF approved make. | — | — | — | 1,89,602.4 | |
| — | 24.00 | — | — | ||
| Price for removal of defective compressor contactor and re-fitment with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 19,168.8 | |
| — | 24.00 | — | — | ||
| Price for supply of new condensor motor contactor Type-L54K 10E DC110V (With Diode) 77.137 V DC AEG make of TAL 16-30 01/110V DC+RT 5/150+CAS-01 ABB make or RDSO/RCF approved make. | — | — | — | 1,02,093.6 | |
| — | 24.00 | — | — | ||
| Price for removal of defective condensor motor contactor and replacement with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 19,168.8 | |
| — | 24.00 | — | — | ||
| Price for supply of new blower motor contactor type-LS4L 10B DC110V (with diode 1HS7K01) 77-137 VDC AEG make or TAL 16-30 01/110V DC +RTS/150 + CAS-01 ABB make or RDSO/RCF approved make. | — | — | — | 1,02,093.6 | |
| — | 24.00 | — | — | ||
| Price for removal of defective blower motor contactor and replacement with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 21,877.2 | |
| — | 5.00 | — | — | ||
| Price for supply of new blower motor runner (A type + B type) with new one. | — | — | — | 54,693 | |
| — | 5.00 | — | — | ||
| Price for removal of defective blower motor runner and re-fitment (A type + B type) with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 18,838.7 | |
| — | 4.00 | — | — | ||
| Price for supply of new flapper of servo motor. | — | — | — | 7,733.24 | |
| — | 4.00 | — | — | ||
| Price for removal of defective flapper of servo motor and re-fitment of new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 4,122.08 | |
| — | 2.00 | — | — | ||
| Price for supply of new blower housing complete with motor and runner by new assembly. | — | — | — | 52,279.6 | |
| — | 2.00 | — | — | ||
| Price for removal of defective blower housing complete with motor and runner by new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 6,684.7 | |
| — | 3.00 | — | — | ||
| Price for supply of electronic controller (SRMC-20/22L) compatible with all type of LHB AC Coaches with all sensors. | — | — | — | 7,14,259.56 | |
| — | 3.00 | — | — | ||
| Price for replacement of defective Electronic controller (SRMC-20/22L) and re-fitment with new one with all sensors. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 61,509 | |
| — | 6.00 | — | — | ||
| Price for supply of new fresh air temperature sensor for SRMC-22L microprocessor with LHB RMPU. | — | — | — | 18,160.2 | |
| — | 6.00 | — | — | ||
| Price for removal of defective fresh air temperature sensor for SRMC-22L microprocessor and re-fitment with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 4,983.54 | |
| — | 6.00 | — | — | ||
| Price for supply of new return air temperature sensors for SRMC-22L microprocessor with LHB type RMPU. | — | — | — | 18,160.2 | |
| — | 6.00 | — | — | ||
| Price for removal of defective return air temperature sensors for SRMC-22L microprocessor and re-fitment with new one. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 4,983.54 | |
| — | 6.00 | — | — | ||
| Price for supply & fitment of new double intel centrifugal blower 415 V, 3 phase, 50 HZ, 120W, 450 cubic meter per hr. Discharge for exhausting air from lavatory / switch board cabinet, make- RDSO approved source in place of defective one. | — | — | — | 1,48,400.34 | |
| — | 6.00 | — | — | ||
| Price for supply and fitment of new multifunctional monitoring relay for three main suitable for 750V system, monitoring phase parameters like phase sequence, phase failure over and under voltage and phase unbalance, make similar to ABB, Type- CM-MPN-72 in place of defective one. | — | — | — | 1,28,346.24 | |
| — | 6.00 | — | — | ||
| Price for supply and fitment of new DC-DC converter 110V/24V 20A model no-300-SI- 24 in place of defective one. | — | — | — | 1,42,931.04 | |
| — | 50.00 | — | — | ||
| Price for supply of sealing compound (280ml), cleaning agent orion 510-D (10 Lt), return filter and fresh cassette filter during schedule attention of coaches. | — | — | — | 2,12,695 | |
| — | 50.00 | — | — | ||
| Price for cleaning of condenser & cooling coil, tightness checking of all motor during schedule attention of AC coaches removal of defective return filters fresh air cassette filter and re- fitment with new one and testing with proper instrument. (Defective to be returned to Sr. SE/TL&AC/ASN's store) | — | — | — | 1,81,526.5 | |
| — | 6.00 | — | — | ||
| Price for supply of new air duct complete with frame and associated accessories for all makes of LHB AC coaches similar to spare parts of LHB Type Air Conditioner as per EDTS-075 of Sidwal. | — | — | — | 32,034.54 | |
| — | 6.00 | — | — | ||
| Price for labour charged for removal of defective return air duct & re-fitment of new one with associated accessories. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 20,418.72 | |
| — | 4.00 | — | — | ||
| Price for supply of new set of 2 nos. returned air duct complete with frame and associated accessories for all make of LHB AC coaches similar to Sidwal cat no. SR-075-1055. | — | — | — | 18,231 | |
| — | 4.00 | — | — | ||
| Price for labour charged for removal of defective fresh air duct & re-fitment of new one with associated accessories. (Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 13,612.48 | |
| — | 3.00 | — | — | ||
| Price for supply of new set of 2 nos. fresh air duct complete with frame and associated accessories for all make of LHB AC coaches similar to Siwal Cat No. SR-075-1054. | — | — | — | 11,719.95 | |
| — | 3.00 | — | — | ||
| Price for labour charge for removal of defective fresh air duct & re-fitment of new one with associated accessories.(Defective to be returned to Sr. SE/TL&AC/ASN's store). | — | — | — | 7,292.4 | |
| — | 10.00 | — | — | ||
| Price for supply & replacement of MPCB for ventilation fan unit, rating 3-4A, thermal release rate-2.5-4A, Class10, breaking capacity-100 KA, pole-3, volt-415V AC,1 NO+1NC auxiliary contact block. | — | — | — | 33,423.5 | |
| — | 10.00 | — | — | ||
| Price for supply & replacement of MPCB for compressor unit, rating- 16 A,, thermal release rate-10-16A, Class 10, breaking capacity-100 KA, pole-3, volt-415V AC. | — | — | — | 81,431.8 | |
| — | 10.00 | — | — | ||
| Price for supply and replacement of MPCB for condensor fan unit , rating 2.5A, thermal release rate 1.6 -2.5A, Class-10, breaking capacity-100KA, pole-3, volt-415 V AC. | — | — | — | 33,423.5 | |
| — | 10.00 | — | — | ||
| Price for replacement of defective hinge/latch lock of side entry hood cover (return air filter cover) by new one. RDSO approved material to be supplied. | — | — | — | 10,330.9 | |
| — | 6.00 | — | — | ||
| Price for supply of contactor of 60KVA transformer, voltage 415V, rating-200A, pole-4, 2NO+2NC, control voltage-168-300V AC with surge suppression. | — | — | — | 1,64,079 | |
| — | 6.00 | — | — | ||
| Price for supply of feeder contactor Net-1, Net-2 voltage-750V AC, rating-200A, Pole- 4, 2NO+2NC, control voltage-380-415 V AC with surge suppression. | — | — | — | 1,64,079 | |
| — | 15.00 | — | — | ||
| Price for supply of new 3 pole MCB of 6A/10A/16A/20A. | — | — | — | 27,928.95 | |
| — | 15.00 | — | — | ||
| Price for labour charges for removal of defective MCB & replacement with new 3 pole MCB of 6A/10A/16A/20A. | — | — | — | 18,692.55 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TechComp-IIIIII1_1.pdf
ATTACHMENT
ComlCompliance-U-IVVVIVIIVIII1_1.pdf
ATTACHMENT
GCC April 2022 Adv Correction S 1
ATTACHMENT
GCC April 2022 Adv Correction S 2
ATTACHMENT
GCC April 2022 Adv Correction S 3
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.4.pdf GCC April 2022 Adv Correction S 4
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.5.pdf GCC April 2022 Adv Correction S 5
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.6.pdf GCC April 2022 Adv Correction S 6
ATTACHMENT
SpacialConditionofcontractonlabourdata_1.pdf Spacial Condition of contract on la
ATTACHMENT
FormatofGuaranteeBond_1.pdf
ATTACHMENT
AnnexureVIB_1.pdf
ATTACHMENT
CONDITION.pdf
ATTACHMENT
NewGenl.condition.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.7.pdf GCC April 2022 Adv Correction S 7
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.8.pdf GCC April 2022 Adv Correction S 8
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.9.pdf GCC April 2022 Adv Correction S 9
ATTACHMENT
GCC April 2022 Adv Correction S 10
ATTACHMENT
GCC-April2022.pdf
ATTACHMENT
CheckList_511.pdf
ATTACHMENT
FormatforcertificateANNEXURE-V.pdf
ATTACHMENT
MasterTenderDocumentNew.pdf
ATTACHMENT
GCC April 2022 Adv Correction S 11
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.1_1.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.2_1.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.3_1.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.4.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.5.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.6.pdf
ATTACHMENT
SpacialConditionofcontractonlabourdata_1.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.7.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.8.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.9.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.10.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo.11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .