Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Being Lowest and Reasonable | |
| 2 | L2₹48.9 L+₹5.1 L (11.5%)Rejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC Other than lowest | |
| 3 | L3₹55.5 L+₹11.6 L (26.4%)Rejected-AOC 1723 GUPTA AND SONS SECTOR 39 B CHANDIGARH CHANDIGARH CHANDIGARH 160036 UDYAM CH 01 0042756 | CHANDIGARH | CHANDIGARH | 160036 | L3 | Rejected-AOC Other than lowest |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
15 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Sachin Jaiswal, IDSE, CWE Chandimandir
HQ CWE Chandimandir
CA NO. CWE/CHM(U)-76/2023-24 REPAIR/ MAINT LT SUPPLY SYSTEM AND CONNECTED ITEMS OF WORKS AT HQ WC, ENGRS BR, ASCON COMD OFFICERS MESS, MES IB, OTM AND MISC LOCATIONS AT CHANDIMANDIR
2023_MES_627578_1
CWE/CHM(U)-76/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class C category b(i)
8 documents required · 8 mandatory
₹1,000
Yes
GE(U) Chandimandir
₹1.1 L
Yes
12 Jan 2024
9 Nov 2023
20 Dec 2023
9 Nov 2023
15 Dec 2023
1 Dec 2023
10 Nov 2023 - 17 Nov 2023
Amount
Material & labour in replacement of Power Cables, Aluminum Stranded Conductor 400 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note: 1. Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ. 2. Laying of LTUG Cable includes excavation and laying at certain places in hard standing by removing cross linked tiles, and laying cables, reflling and fixing the tiles to original shape etc., The rates quoted are deemed to be inclusive of necessary civil works to bring the area to original finish and no extra payment will be done on this account.
All as per item No. 1.00 here-in-before but of size 300 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 240 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 185 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 150 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 120 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 95 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 70 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 50 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 35 sqmm, 3.5 core.
All as per item No. 1.00 here-in-before but of size 25 sqmm, 4 core.
All as per item No. 1.00 here-in-before but of size 16 sqmm, 4 core.
Excavation in trenches for foundations, laying / taking out of cables, erecting of poles etc, in any type of soil, not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr in width and getting out, complete all as specified and as directed. Note :- Nothing extra will be paid to the contractor in this account if hard or rocky soil is encoutered during the execution.
Supply and spread M-sand in trenches for cushioning of cable / in the yard of outdoor substations complete all as specified and directed by Engineer-in-Charge. (Note: Punned down thickness only shall be measured for the purpose of payment)
Supply and lay in trenches, un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed by Engineer-in-Charge.
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Material & Labour for cutting of existing hard standing/road up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below hard standing will be measured and paid under relevant items.
Supply and fix in replacement of 100mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed by Engineer-in-Charge.
All as per item No. 19 here-in-before but of size 80mm dia bore.
All as per item No. 19 here-in-before but of size 50mm dia bore.
Supply, laying and testing in reolacement of 50mm outer dia, double wall corrugated HDPE pipe confirming to IS-14930 Part-II with antirodent and non flame propogating properties of approved colour laid in trenches/floors/duct or fixed on wall/pole including all connections, accessories like socket, couplers, bends etc for protection of LT XLPE Cable grade 1100 volts complete all as specified and directed by Engineer - in - Charge. (for LT cable protection upto 70 Sqmm, 3.5 core cable)
Material & labour for Trimming of tree branches around the LT overhead conductor, poles (not less than 3 mtr) to clear the approach of overhead including removing of nest, wild grass creepers, unwanted vagetation etc from pole/stay including cleaning of creepers climbed on poles and angles, channels and disposal off from site beyond 50 mtr and up 250 mtr complete all as specified and directed by Engr-in-Charge. (Note : span of 30 m to 50 m shall be considered as one unit.
Material and labour for Surface dressing not exc 15cm deep in any type of soil and site clearance including cutting and removing of plants/bushes, leveling of surface area, throw wastage material out of fencing area/ compound wall up to 50m distance at sub station areas / pump House areas complete all as specified and as directed by Engineer-in-Charge.
Material & labour for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
Material & labour for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to copper strip 20x3 mm as earthing lead by means of bolts, nuts, check nuts and washers of copper and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure/ panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip up to 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II
Supply and fix of GI strip 32 x 6 mm for earthing complete all as specified and directed by Engr-in-Charge.
Supply and fix of Copper strip 20 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement of MCCB 630 A ,4 pole ,50 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix in replacement of MCCB 500 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix in replacement of MCCB 400 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix in replacement of MCCB 315/350 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix in replacement of MCCB 250 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix in replacement of MCCB 200 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
Supply and fix in replacement of MCCB 160 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 800 Amps four pole mannual draw out with thermal magnetic release based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable ACB any type and Supply, installation testing and commissioning new LT ACB of 1000 Amps four pole mannual draw out with thermal magnetic release based, 415 Volts, 50 Hz suitable for existing location alongwith replacement of burnt aluminum bus bar with connected nut bolts and lugs with new aluminum bus bar /nut bolts/lugs complete all as specified and directed by Engr-in-charge.
Shutdown the power supply, disconnecting all incoming & outgoing cables carefully from outdoor type LT panel board, removing the burnt wiring, cleaning the bus bars, insulators and MCCBs with CTC, meggering the insulation value and replacing the bus bar supporting insulators wherever required to achieve required insulation resistance value, tightening all fasteners (renew if required), reconnecting back the incoming and outgoing cables with suitable cable Lugs, glands and wrapping the insulation tape on all bare conductors, supply and fixing EPDM rubber gasket for all doors for dust & vermin proof etc and testing on completion for proper functioning complete all as specified and directed by Engineer-in-Charge. Note: (i) Replacement of unserviceable MCCBs shall be measured and paid separately. (ii) Replacement of broken/corroded metal sheets/ angle iron parts of panel boards shall be measured and paid separately.
Material and labour for old and deteriorated MS sheet of any size and shape from the outdoor/indoor panel 3.00 mm thick and fix on outdoor/indoor panel as per required size and shape complete inclusive fixing the hinges, door lock etc, inclusive super enamelled paint as per existing colour over two coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Material & labour for Preparation of old steel surfaces of outdoor type LT panel boards of any size and painting with synthetic enamel paint of approved colour over a coat of red oxide primer (both internally & externally) and fixing 02 Nos steel danger plates on panel board complete all as specified and directed by Engineer-in-Charge.
Supply only LT insulation tape ( FR PVC electrical insulation tape ) 0.125 mm thick , 1.80 cm width and 25 mtr length. complete all as specified and directed.
Supply and fix in replacement of On-Load Changeover switch 4 Pole, 315A, 415 Volts, AC, 50 Hz in sheet Metal enclosure with front operated handle complete all as specified and directed. Note: Any modifications needed for fixing the open execution awitch in the panel is deemed to be included in the rates quoted and no extra payment will be done on this account
Supply and fix in replacement of On-Load Changeover switch 4 Pole, 400A, 415 Volts, AC, 50 Hz in sheet Metal enclosure with front operated handle complete all as specified and directed. Note: Any modifications needed for fixing the open execution awitch in the panel is deemed to be included in the rates quoted and no extra payment will be done on this account
Supply and fix in replacement of On-Load Changeover switch 4 Pole, 630A, 415 Volts, AC, 50 Hz in sheet Metal enclosure with front operated handle complete all as specified and directed. Note: Any modifications needed for fixing the open execution switch in the panel is deemed to be included in the rates quoted and no extra payment will be done on this account
Supply, jointing and testing Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm complete all as specified and directed.
Supply, jointing and testing Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm complete all as specified and directed.
Supply, jointing and testing Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 Sqmm complete all as specified and directed.
Supply, jointing and testing Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm complete all as specified and directed.
Supply, jointing and testing Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 400 to 500 Sqmm complete all as specified and directed.
Supply and connect in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor and overall PVC sheathed in service connections one twin core cable flat or circular of size 10 sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and connect in replacement of 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor and overall PVC sheathed in service connections one twin core cable flat or circular of size 6 sqmm complete all as specified and directed by Engineer-in-Charge.
Design, fabricate, supply, installation, testing and commissioning in replacement of outdoor type dust proof & vermin proof cubicle panel board compartmentalized with seperate bus and cable alley chambers suitable for 3 phase, 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory (Manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate.
Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1300mm x 1300mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and directed:- Loc - Signal Centre Inside & MES IB
Note: (i) Factory made name plates with feeder names / Bldg Nos shall be fixed on relevant incomer / outgoing MCCB doors. (ii) The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
(iii) Outgoing:- (a) MCCB, 200 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 Nos (b) MCCB, 160 A, 3 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 04 Nos (c) MCCB, 63 A, 3 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No (d) On-Load Changeover switch 4 Pole, 400A, 415 Volts, AC, 50 Hz in sheet Metal enclosure with front operated handle - 01 No
Design, fabricate, supply, installation, testing and commissioning in replacement of outdoor type dust proof & vermin proof cubicle panel board compartmentalized with seperate bus and cable alley chambers suitable for 3 phase, 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory (Manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate.
Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1300mm x 1300mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and directed:- Loc - Shivalik Re-Treat
Note: (i) Factory made name plates with feeder names / Bldg Nos shall be fixed on relevant incomer / outgoing MCCB doors. (ii) The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing. However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
(iii) Outgoing:- (a) MCCB, 315 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 Nos (a) MCCB, 250 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 Nos (a) MCCB, 200 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 02 Nos (b) MCCB, 160 A, 3 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 02 Nos (d) On-Load Changeover switch 4 Pole, 400A, 415 Volts, AC, 50 Hz in sheet Metal enclosure with front operated handle - 01 No
Design, Fabricate, supply, installation and testing in replacement of outdoor type cubicle panel board bus bar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40mmx40mmx5mm angle iron base frame of suitable size for mounting the panel board at a height of 450mm above GL and grouted in PCC foundation. The size of panel board shall not be less than 500mm x 500mm x 300mm (outer dimensions) for accommodating and including taking down old unserviceable and provision of following switchgears complete:- (i) TPN Aluminium bus bar 200 Amps 4 strips provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision suitable glands. (ii) MCCB, 200 A, 4 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No
Excavation in post holes (or similar holes) each not exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete in any type of soil.
Material & labour for mild steel work as of posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets(for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Supply and fix of Galvanized Steel Chain Link fencing of mesh size 50mm x 50mm and dia of wire 4.00mm with and including line wires fixed to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed by Engineer-in-Charge.
Material & labour for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc conforming to Fe.290.Gde-E-165 including taking down existing framed work of any description complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil in the transformer yard complete all as specified and directed by Engineer-in-Charge.
Supply and spread graded coarse aggregate of 63mm nominal size around outdoor transformer and HT 11 KV two/four pole structure complete all as specified and directed.
Material & labour for Brickwork with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Material & labour for rendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as specified and directed by Engr-in-charge.
Material & labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure, complete all as specified and directed by Engr-in-charge.
HARISH SALES CORPORATION
M/S Gupta and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .