Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹29.2 L+₹48,305 (1.68%)Rejected-Finance | L2 | Rejected-Finance Being not lowest bidder | |
| 3 | L3₹38.9 L+₹10.2 L (35.6%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance Being not lowest bidder |
Tender Value
₹35.3 L
EMD Value
₹70,640
Closing Date
17 Oct 2019, 6:00 pmClosed
GE
GE (AF) MC CHANDIGARH
Repair Replacement to existing unserviceable water supply pipe lines valve chamber sluice valve and other connected works at BRD AF Stn Chandigarh under GE AF MC Chandigarh
2019_MES_274937_2
GE(AF) MC CHD-23/2019-20
Open Tender
Miscellaneous Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE (AF) MC CHANDIGARH
₹70,640
Yes
CHANDIGARH
18 Jan 2020
4 Oct 2019
19 Oct 2019
4 Oct 2019
17 Oct 2019
8 Oct 2019
5 Oct 2019 - 8 Oct 2019
8 Oct 2019
Amount
Taking out damaged /unservicable submercible 3 core 35 sq mm cable ,Supplying, laying and testing PVC insulated & PVC sheathed industrial 3 core 35 sq mm flat SUBMERSIBLE cable with bare bunched copper conductor for submersible pump & motor with voltage grade 1100 volts generally conforming IS :694. COMPLETE INCOMING 7 OUTGOING CONNECTION INCLUDING 50 SQ MM COPPER LUGS all as directed by Engr in charge. MAKE-Havells/Polycab/ FINOLEX. Note:- Taking out pump set with column pipe from bore well deemed to be included in quoted rate.
Taking out damaged /unservicable submercible 3 core 25 sq mm cable ,Supplying, laying and testing PVC insulated & PVC sheathed industrial 3 core 25 sq mm flat SUBMERSIBLE cable with bare bunched copper conductor for submersible pump & motor with voltage grade 1100 volts generally conforming IS :694. COMPLETE INCOMING 7 OUTGOING CONNECTION INCLUDING 50 SQ MM COPPER LUGS all as directed by Engr in charge. MAKE- Havells/Polycab/ FINOLEX. Note:- Taking out pump set with column pipe from bore well deemed to be included in quoted rate.
Dismantling of unserviceable valve PIT chamber,breaking of Hardstanding and road completely items like as sluice valves ,CI /DI assories sluice valves ,nut bolt washers,pipes and making valve size pit 130cmx130cmx120cm additional flanged CI 150 mm size pipe extended up both side up to 6 mtr distance competely .The rising of hight of valve pit chamber up to 60 CM from Ground level. The top of PCC in foundation to Taking out MS Frame completly from valve pit and refixing again after reparing the valve pit with fixing arrangement, hinges and locking arrangement and two coat of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work,welding works required at site , returning filling ,deposited surplus soil to a distance not exceeding 50 Mtrs, 150mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, brick work in cement mortar 1:6 and 15mm thick plastering in CM 1:4, thick PCC 1:2:4 type B-1 as in copping complete all as specified and directed by Engr-in-Charge. Note- Cost of excavation, valve chamber cover and brick work ,150 mm flange pipes,nut bolts ,fittings jonts ,etc complete is included in this item, Nothing extra payment is admissible on this account. Contractor are advised to visit the site to under stand the complete work.
Dismantling of unserviceable valve PIT chamber completely items like as sluice valves ,CI /DI accessories sluice valves ,nut bolt washers,pipes and making of valves pit size 120X120X120 Cm the top of PCC in foundation to the top of MS cover with and including 3mm thick MS sheet and frame as per existing of angle iron with fixing arrangement, hinges and locking arrangement and two coat of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil returning filling in approved soil, deposited surplus soil to a distance not exceeding 50 Mtrs, 150mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, brick work in cement mortar 1:6 and 15mm thick plastering in CM 1:4, 150 mm thick PCC 1:2:4 type B-1 as in copping complete including dismantling of damaged valve pit material all as specified and directed by Engr-in-Charge. Note- Cost of excavation, valve chamber cover and brick work , fixing of 150 mm dia CI/DI pipes,nut bolts ,fittings jonts ,etc complete is included in this item, Nothing extra payment is admissible on this account.
Dismantling of unserviceable valve chamber completely and construction of brick masonry valve pit size 60x60x60cm (internal size of chamber) for gate valve upto 150 mm dia, depth of chamber to be reckoned from the top of PCC in foundation to the top of MS cover with and including 3mm thick MS sheet and frame of angle iron 40mmx40mmx 6mm with fixing arrangement, hinges and locking arrangement and two coat of synthetic enamel paint over a coat of red oxide primer on MS cover and frame including necessary excavation and earth work in any type of soil returning filling in approved soil, deposited surplus soil to a distance not exceeding 50 Mtrs, thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, brick work in cement mortar 1:6 and 15mm thick plastering in CM 1:4, 150 mm thick PCC 1:2:4 type B-1 as in copping complete including dismantling of damaged valve pit all as specified and directed by Engr-in-Charge. Note- Cost of excavation, valve chamber cover and brick work complete is included in this item, Nothing extra payment is admissible on this account.
All as per item No. 5 above but size 90cmx90cmx90cm for Sluice Valve upto 100mm bore complete all as specified and directed by Engineer-in-Charge.
All as per item No. 5 above but size 120X120X120 Cm for Sluice Valve upto 150mm bore complete all as specified and directed by Engineer-in-Charge.
Spray painting to water supply pipe line of size 150 mm any type including preparing the surface by removing the peeled old paint with scrapper, cleaning the surface and painting with two coats of synthetic enamel paint of 1st quality as per standard shade and colour approved complete all as specified and directed by Engineer-in-Charge
Spray painting& to sluice valves of size 150/100 /80 mm mm dia including preparing the surface by removing the peeled old paint with scrapper, cleaning the surface and painting with two coats of synthetic enamel paint of 1st quality as per standard shade and colour approved complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.50 meter wide not exc 1.50 meter deep in soft/ loose soil for taking out/ laying pipe line and getting out complete all as specified .
Returning filling in, including spreading leveling, in layers not exc 25 cm thick all as specified ad directed by Engr-in-Charge.
Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point
Taking out u/s pipe lines from trenches /wall/ open area and Supply laying testing of steel water tubing galvanized iron medium grade laid in trenches with all fittings such as bends. Elbow, tees, short piece, connections , back nuts, diminishing pieces, caps plugs and unions etc for the following sizes complete all as specified and as directed by the Engr-in-Charge. Make:- Jindal/Tata/Parkash Surya
(a) 15 mm bore pipe
(b) 20 mm bore pipe
(c) 25 mm bore pipe
(d) 40 mm bore pipe
(e) 50 mm bore pipe
(f) 80 mm bore pipe
(g) 100 mm bore pipe
Taking out unservicable gate valves Supply in replacement of gun metal globe or gate valve (class-1) with iron wheel head screwed both ends for iron pipes or unions conforming to IS-778 complete with jointing materials like rubber sheet, nuts and bolts for the following sizes complete all as specified and directed by the Engr-in-Charge Make- BIR/Zoloto/Sant
(a) 15 mm bore pipe
(b) 20 mm bore pipe
(c) 25 mm bore pipe
(d) 40 mm bore pipe
(e) 50 mm bore pipe
(f) 80 mm bore pipe
(g) 100 mm bore pipe
Supply laying ,testing CI pipe lines of size 80 mm CLASS LA water mains (Including all fittings making connection to existing lines ) with spigot and socket ends and lead joints etc including taking out lead from joints complete all as specified and directed. Make- Electro Steel/Tata/Kejriwal
Taking out unservicable pipe line of size 100 mm dia Supply laying ,testing CI pipe lines of size 100 mm dia CLASS LA water mains (Including all fittings making connection to existing lines ) with spigot and socket ends and lead joints etc including taking out lead from joints complete all as specified and directed .Make- Electro Steel/Tata/Kejriwal
Taking out u/s pipe line of size 150 mm dia Supply laying ,testing CI pipe lines of size 150 mm CLASS LA water mains (Including all fittings making connection to existing lines ) with spigot and socket ends and lead joints etc including taking out lead from joints complete all as specified and directed (Earth work shall be measured and paid for separately) Make- Electro Steel/Tata/Kejriwal
Supply in replacement of cast iron fitting for spigot sockt pipe up to 150 mm bore such as bends, tapers, tee pieces (single & double branch) any type and angle tapers any type (straight, bends, increasing, decreasing or double socket etc) Tee branch single branch, 'Y' junction, double branch cross collars caps and plugs up to 150 mm bore complete all as directed by Engineer-in-Charge
Supply and layig ductile iron pressure pipe with spigot and socket ends centrifugally cast class K-9 in ay length confirming to IS-8329:2000 of 150 mm bore complete all as specified and directed by Engr-in-charge. Make: Electro Steel casting/Jindal SAW Pipes/Tata/Lanco
S&F non return reflex valve with bypass arrangement of size 150 mm dia complete all as specified and diretcted by Engr-in-charge Make- Leader/Kirloskar/L&T/Audco
Supply in replacement for run lead joints suitable for 150 mm bore CI pipe and fittings including jointing material such as lead, spun yarn etc complete all as specified and directed by Engineer-in-Charge
Description all as per serial item No 21 here-in-before but 100 mm bore pipe and fittings complete all as specified and directed by Engineer-in-Charge
Description all as per serial item No 21 here-in-before but 80 mm bore pipe and fittings complete all as specified and directed by Engineer-in-Charge
Repair/rectification to leakage of CI water pipe line of size 80mm to 100mm dia Spigot and socket ends complete all as specified and as directed by Engr-in-Charge Note :- Materials i.e flanged, gasket ,Lead/Lead wool, spuryan etc are included in the quoted rates.
Repair/rectification to leakage of CI water pipe line of size 150mm dia Spigot and socket ends complete all as specified and as directed by Engr-in-Charge Note :- Materials i.e flanged, gasket ,Lead/Lead wool, spuryan etc are included in the quoted rates.
Repair to leakage of GI water pipe line of size 15 mm to 50 mm complete all as specified and as directed by Engr-in-Chgarge. Rates of GI fittings are included in quoted rates.
Repair to leakage of GI water pipe line of size 80 mm to 100 mm complete all as specified and as directed by Engr-in-Chgarge Rates of GI fittings are included in quoted rates.
Supply in replacement of cast iron sluice valve PN-1 with flanged ends 150 mm nominal bore ISI marked complete with gun metal or stainless steel spindle and cast iron hand wheel including rubber /fiber board gasket nuts, washers etc incl taking down old unsv sluice valves complete all as specified and as directed by Engineer-in-Charge. MAKE SANT/KIRLOSKER/UPDHAYA/BIR
Description all as per srl item No 28 here-in-before but sluice valve 100 mm nominal bore complete all as specified and as directed by Engineer-in-Charge.
Description all as per srl item No 28 here-in-before but sluice valve 80 mm nominal bore complete all as specified and as directed by Engineer-in-Charge.
Taking out sluice valves refacing, regrinding and packing material etc and refixing of the following sizes complete all as specified and directed by the Engineer-in-Charge
(a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
Supply in replacement MS nut bolts of suitable sizes for both glands, flanges on both ends and top canopy of the sluice valves complete all as directed by Engineer-in-Charge.
Supply in replacement of 3 mm thick rubber sheet packing at both ends sluice valve flange for the size 150 mm complete all as directed by Engineer-in-Charge.
Repairing /Painting of 150 mm flanged pipes/sockted pipe lines up to hight of 40 mtr from ground level over head tanks by help of manpower/hangaging pad cleaning the lines including valves (Inlet, outlet and drain valves) painting of 150 mm flanged /sockted lines of over head tank as per existing colour all necessary tools , materials ,man power provided by contractor at site all as directedby Engineer -in- Charge.
Taking down u/s COPPER cable from star delta starters/ motors/panels of size 50 sq mm single core copper cable and Supply ,laying & testing single core FR PVC INDUSTRIAL GRADE COPPER CONDUCTOR (UNSHEATHED )FLEXIBLE CABLE 50 SQ MM 1100 VOLT GRADE CONFORMING TO is 694, complete cover with flexible conduit for protection of cable including all out going ,incoming connection with 50 sq mm copper lugs 03 nos on panel side and 03 nos on motor side all as specified and directed by EIC. MAKE- HAVELLS/PLAZA/FINOLEX/PARAGON
Taking down u/s COPPER LUG of existing 25 sq mm to 50 sq mm from panel MCCB/BUSBARS ETC supply ,fixing and testing ofCOPPER LUGS of size 25 to 120 sq mm copper lugs for25 sq mm to 120 sq mm for any type of cable and fixing on motor /panel /starter etc all as specified and directed by EIC. MAKE- Hex/dowells/Jaipuria brothers
S&F new power contactor 3 pole ML-4 of L& T cat No SS90910 with DC coil of AC-3 rating 70 to 110 Amps Amps suitable for motor including connection with suitable size copper cable and removing unsv cable and connection with new coper lugs, nut bolts including taking out old unserviceable contactor form existing LT panel of pump house complete all as specified and directed by the Engr -in -charge.MAKE EQUVILENT TO BCH/LEGRAND /SCHNIDER /GE/SIEMEN
S&F new power contactor TYPE MNX 95 (2 NO+2 NC) ,3 pole of L& T cat No CS94136 with DC coil of AC-3 rating 160 Amps suitable for motor including connection with suitable size copper cable and removing unsv cable and connection with new coper lugs, nut bolts including taking out old unserviceable contactor form existing LT panel of pump house, complete all as specified and directed by the Engr -in -charge.
Taking ouit unservicable over load relay S&F new oTHERMAL OVER LOAD RELAY WITH START & OFF/RESET (ML-2) CAT N0-SS94144 RANGE 14TO 23 AMP MAKE -L &T for protection of motor & pump and all connection s complete all as specified and directed by the Engr -in -charg. MAKE L&T/(GIC)/HPL/SIEMENS /LEGRANDE and equvilent .
Taking ouit unservicable over load relay S&F new oTHERMAL OVER LOAD RELAY WITH START & OFF/RESET (ML-2/3) CAT N0-SS91859 RANGE 28TO 42 AMP MAKE -L &T for protection of motor & pump and all connection s complete all as specified and directed by the Engr -in -charg. MAKE L&T/(GIC)/HPL/SIEMENS /legrande and equplient.
Taking ouit unservicable over load relay S&F new oTHERMAL OVER LOAD RELAY WITH alarm contact (ML-5 ) CAT N0-SS 94137 RANGE 45 TO 75 AMP MAKE -L &T for protection of motor & pump and all connection s complete all as specified and directed by the Engr -in -charg. MAKE L&T/(GIC)/HPL/SIEMENS /legrande and equplient.
Taking out unserviceable single phase preventer and supply and fixing supply monitoring device series SM-500 phase Neutral voltage control preventer 415 volt, VAC,3 P4 W,Frequency 43 to 53 HZ Protection at over voltage ,under voltage ,un balance voltage ,phase fault ,phase reversal ,neutral fault etc all as directed at site.MAKE – GIC OF L&T-CAT NO-MAC04D/SIEMENS /BCH/SCHNEDIER and equvilent .
Taking out unservicable ,broken solar water pvc tank of capcity 500 ltr supply and fixing,testing rotational moulded polythylene water storage tank (cylindrical vertical with closed top) hosted and fixed in postion and making all in coming out going connection & testing complete of capacity 500 LTRS ISI MARK.
Taking out unserviceable water level indicator from RCC overhead tank supply, fixing and tesing of Digtal water level indicator ISI marked suitable for 75000/100000 gallons RCC over head tank complete all as directed by EIC.
Supply for Water treating powder Model - Chlorine (Equafit) pack 45 kg for treatment of water all as directed and specified EIC. Made : RMCO/Aquafit/Equafit
Taking out unserviceable rusted pipe of 100 mm dia supply fixing & testing GI Column pipe heavy duty 100 mm dia both end of each pipe welded with MS flanges drilled and slotted for submersible cable including MS bolts, nuts, washers and rubber gasket in joints complete all as direted by Engineer-in-Charge. Make : JINDAL/TATA/KALINGA. Note : Taking out column pipe & lowering of pipe will be the responsibility of contractor and arranged by contractor and deemed to be included in coated rate.
WR Traders
SANJEEV ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .