GE (AF) MC CHANDIGARH
GE (AF) MC CHANDIGARH
SPECIAL REPAIR TO WATER PIPELINES AND OTHER MISC DEPILATED SERVICES AT ETH AT 3BRD AF STN CHANDIGARH UNDER GE (AF) MC CHANDIGARH
2022_MES_552937_2
GE (AF) MC /CHD-42/2022-2023
Open Tender
Civil Works
Item Rate
270 days
CHANDIGARH
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) MC Chandigarh
₹78,000
Yes
1 Feb 2023
31 Oct 2022
16 Nov 2022
31 Oct 2022
14 Nov 2022
1 Nov 2022
Amount
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m deep for laying of pipes etc and getting out including cutting of grass and bushes complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of surplus soil to a distance exc 1.5km but n.exc 2.0Km away and depositing where directed at a level not exc 1.5 above the starting point complete all as specified and directed.
Material and labour for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supply and laying precast concrete cable cover, class LV type 1 made of M-30 using 20mm graded stone aggregate, flat of size 250mmx150mmx40mm, complete all as specified and directed.
Supplying, laying, Jointing and testing in trenches new ductile iron pipe conforming to IS-8329-2000, class K-9 (ISI marked) of size 100 mm dia bore in any length laid in excavated trenches including all CI/DI fitting and run lead joint /tyton push or rubber gasket joint with spigot and socketed ends cope of any size and any description complete including taking down old pipe of any description and any size complete all as specified and directed.
Supplying, laying, Jointing and testing in trenches new ductile iron pipe conforming to IS-8329-2000, class K-9 (ISI marked) of size 150 mm dia bore in any length laid in excavated trenches including all CI/DI fitting and run lead joint /tyton push or rubber gasket joint with spigot and socketed ends cope of any size and any description complete including taking down old pipe of any description and any size complete all as specified and directed.
Supplying, laying, jointing and testing of GI Pipe medium grade inclusive of all fittings such as bends, Tee, union, elbow, reducer and Socket etc. ISI marked of following sizes including taking down old pipe complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid seperately.
40mm bore
50mm bore
80mm bore
100mm bore
Material and labour for brick work with fly ash bricks straight or curved on plan exceeding 6m mean radius, built in CM (1:6), complete all as specified and directed.
M & L for PCC 1:3:6 type B-0 (12.5 mm graded stone agg ) as in coping complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on brick work, concrete surfaces at any height finished even and fair without using extra cement of complete all as specified and directed.
Supplying, installing, testing and commissioning of Round Bottle shaped FRP cooling tower of Min 6,00,000 K.Cal/hr , 160 TR heat rejection capacity with FRP water basin, honeycomb design PVC fill, drift eliminator, self-rotating sprinkler, statically/dynamically balanced axial flow type fan of aluminum alloy , direct drive with TEAO induction motor suitable for 415±10% volts, 50±3% Hz, 3 phase AC supply. Basin shall be provided with suitable accessories like drain , overflow, float valve & quick fill arrangement. Each cooling tower shall be complete with suitable GI ladder including taking down old FRP cooling tower. Cooling tower operating parameters shall be : water flow rate : 1600 LPM Inlet Water Temperature : 42° C Outlet Water Temperature : 32° C Design Wet Bulb Temperature : 28° C Make : MIHIR ENGINEERING PVT .LTD/DELTA COOLING TOWER CO
M & L for 100 mm thick PCC (1:3:6) type C-2 using 40mm thick stone aggregate as in sub base under chilled water pipe line complete all as specified and directed. Note :- 1. Cost for removing bushes, cleaning and leveling and preparing of area for PCC is deemed to be included in the quoted rates. 2. PCC work and provisioning of new pipes with insulation is to be completed within 20 days in any circumstances.
M&L for Insulation of GI pipe with PUF slab 30mm thick with and including applying one coat of hot bituminous compound and GI cladding with 26 gauge GI sheet for 80mm to 100mm bore pipe, complete all as directed.
Material and labour for repair/arresting of leakages from RCC water OH tank of cap 25000 ltrs at height 25 mtrs by means of draining of water cleaning of tank inside and outside taking out any scrubs, repairing of tank from inside and outside by using water proofing compound to make the tank leak proof, preparing of inside and outside surface of OH tank and plastering 15 mm thick using cement mortar 1:4 and mixing with water proofing compound, inside and outside of tank including tank pillars -04 Nos and painting of OH tank complete with two coats of cement base paint of sky blue colour and painting MS ladder with black synthetic enamel paint 2 coat complete including repair of MS ladder by means of doing patch welding works to steps and side railing complete all as directed. Note : (a) Cost of scaffolding/T&P required for repair work is deemed to be included in the quoted rates. (b) Any mild steel section required for repair of ladder apart from welding shall be measured and paid separately under item ser No 41 here-in-after. (c) Bidders are directed to visit the site before quoting the tender for assessing scope of work on ground.
Material, labour and T&P for Cleaning of static water tank ( Test Bed tank) of cap 50000 gallons by Pumping out water from SWT and removing of sludge mechanically or manually and disposing it off at a distance of not less than 100 mtr from SWT . Cleaning of side walls and bottom surface by scrubbing the deposit and removing the same. Cleaning of the walls with high pressure water jet and pumping out the dirty water . Sterilization of tank by eco-friendly degradable and highly effecting ( anti bacteria and anti fungus chemical), replacement of damaged tiles for walls and floor of same colour and quantity approx 10 sqm in each SWT using cement mortar 1:2 and filling of tank with fresh and clean water complete all as directed.
M&L for disconnecting of monoblock pump set of cap 12 HP to 15 HP from suction and delivery line and from PCC foundation and shifting from PH building to covered SWT NO 1 and 2 at ETH . Installation the pump set on PCC/MS foundation and connecting the same with suction and delivery line of suitable size and connecting electrically with submersible cable and testing for smooth and trouble free running complete all as directed. Note for item S No 8, 13,14, 15,16 &17 :- Contractor will arrange man power and material in such a way that activities such as replacement of chilled water pipe line item ser No 8.01 to 8.04, PCC under chilled water pipe line under item ser NO 13 , Insulating of Chilled water pipes under item No 14, Repair to RCC OH tank under Item ser No -15, cleaning of SWT shall be carried out item No 16 and Shifting of pump set from pump house to SWT under item No 17 and simultaneously and will be completed within 20 days so that Air Force work is not hampered. Any delay beyond 20 days from handing over the particular site a penalty of Rs 10000/- per day shall be recovered from the due RAR
M & L for PCC 1:3:6 type B-2 (40 mm graded stone agg ) as in foundation filling and mass concrete, complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size, polished confirming to IS-15658 of 80mm thickness M-40 grade, laid over and including 50mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate and including sand cushion of 40mm thick , complete all as specified and directed. Note :- Cost for cutting of bushes and leveling of area before concrete sub base is deemed to be included in the quoted rates
Supplying, laying, testing, connecting and commissioning under ground LT cable size 120Sqmm, 3.5core, 1100 Volts grade heavy duty XLPE insulated armoured with aluminium stranded conductor complete laid in trenches/fixed to pole/drawn through pipe with suitable size cable glands, crimping type cable lugs etc including taking down existing unserviceable cable, complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately.
Supply, installation , electrically connection and commissioning of LT cubical panel board indoor type factory fabricated totally enclosed with dust and vermin proof free standing fully compartmentalized and of suitable size design suitable for 415 volts, 3 phase 50 HZ 4 wire AC system degree of protection shall be IP-54 and made out of 1.6 mm thick CRCA sheet . The panel shall have TPN copper bus bar made of high conductivity pure copper of rating 400 Amps and provision of interconnection with copper strip/leads of different size from main bus bar to switchgear . The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulators of size not less than 50x50 mm conical/square type at a maximum interval of 300 mm throughout the length of the TPN bus bar and provided with CTs of appropriate rating for metering equipments. The cubical shall have copper TPN extension links of current carrying capacity 60 Amp , respectively . The extension links shall not be less than 300mm long supported on DMC/epoxy insulators having provision for termination of incomer and outgoing cables. The panel shall be powder coated seimen grey structural and mounted on a zinc metal coated stand of size ISMC 100 x 50. Panel shall be front and back openable, double door system lockable/openable by key from both sides and shall have louvers and air vent gasket for natural flow of air 'U' type gasket shall be used to make the panel completely vermin proof. The bottom of the panel shall contain a detachable plate having provision of entry of amroured cable of adequate size with MS glands, The panel shall have the following switchgears /starters and other accessories including dismantling old panel:-
M&L for PVC insulated copper conductor flat submersible cable 1100 volts grade of 10 Sqmm 3 core size duly connected and lowered with submersible pump set including taking down old cable complete all as directed.
Material and labour for Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 25 x 4 as earth lead fixed by means of nuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia medium grade with funnel and wire mess including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc including dismantling old earthing, complete all as directed and specified.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm dia galvanised iron strip, complete all as specified and directed.
Supply and fix in repair gate valve, 80 mm Ø bore flanged end with following specification, (i) Body, bonnet and wedge made of bronze (ii) Non-rising stem made of brass resistant to dezincification (DZR) (iii) Stem seal with gland packing made of material containing Teflon (iv) Connection thread according to EN 10226 with thread run out (v) MOC : Bronze (vi) Surface : Unplanted (vii) Max. operating pressure : 25 Bar (ix) Application media : Water Make: Audco/ Universal/Leader
Supply and fix in repair gate valve, 100 mm Ø bore flanged end with following specification, (i) Body, bonnet and wedge made of bronze (ii) Non-rising stem made of brass resistant to dezincification (DZR) (iii) Stem seal with gland packing made of material containing Teflon (iv) Connection thread according to EN 10226 with thread run out (v) MOC : Bronze (vi) Surface : Unplanted (vii) Max. operating pressure : 25 Bar (ix) Application media : Water Make: Audco/ Universal/Leader
S & F in repair cast iron foot valve with strainer brass body confirming to IS:4038-1986, of size 80 mm dia complete all as specified and directed
S & F in repair cast iron foot valve with strainer brass body confirming to IS:4038-1986, of size 100 mm dia complete all as specified and directed
Supply and fix in repair cast iron swing type check valve 80 mm dia with flange end for water application complete all as directed. Make: Audco/Universal/Leader
Supply and fix in repair cast iron swing type check valve 100 mm dia with flange end for water application complete all as directed. Make: Audco/Universal/Leader
S&F in repair CI sluice valve of 80mm bore size with stainless steel spindle and brass check nut with operative iron wheel with flanged ends class PN 1.6 conforming to IS-14846/2000, ISI marked including all jointing materials such as rubber gasket, nuts, bolts and washers etc complete all as specified and directed
S&F in repair CI sluice valve of 100mm bore size with stainless steel spindle and brass check nut with operative iron wheel with flanged ends class PN 1.6 conforming to IS-14846/2000, ISI marked including all jointing materials such as rubber gasket, nuts, bolts and washers etc complete all as specified and directed
S&F in repair CI sluice valve of 150mm bore size with stainless steel spindle and brass check nut with operative iron wheel with flanged ends class PN 1.6 conforming to IS-14846/2000, ISI marked including all jointing materials such as rubber gasket, nuts, bolts and washers etc complete all as specified and directed
M&L for construction of brick masonry valve pit 120cm X 120cm X 120cm having 230mm thick brick wall in cement mortar 1:6 and plastered with 15mm thick in cement mortar 1:6 all around including external surfaces of walls and internal walls with bottom of chamber pit duly cement based paint on all exposed surfaces of the following size with mild steel sheet cover 3 mm thick and angle iron frame of size 40 x 40 x 6 mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and including provision of suitable hold fasts to hold the frame, locking arrangement and lifting handle ( including Excavation/earth work) complete all as specified and as directed.
Supply and fix in repair Monoblock pump set electric operated 415 V, 3 phase 50 HZ 1500 RPM having Power rating 11 KW Motor HP - 15 HP, discharge range -8.1- 4.9 Ltrs Head range -52-76 Mtrs suitable for 65 mm suction size and 50 mm discharge size complete all as directed. Make : Kirloskar Model KSD-1575+ or equivalent in /Crompton/Wasp
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine with and including HDPE pipe of 250 mm dia suitable for 0.4 mpa working pressure complete all as directed.
M&L for wire mesh filter of size 0.95mtr x1.80 mtr made of MS flat of size 40x5mm and MS sheet 6 mm thick with a provision of 02 Nos lifting hook on top including taking out old rusted /unserviceable wire mesh filters complete all as specified and directed
Supply, installation of Glycerin filled pressure gauge with gauge cock, 100 mm dia , toughened glass window bottom centre mounting, accuracy class 1.6 as per EN 837-1 and degree of protection IP -67 including making necessary provision for fixing of pressure gauge on GI pipe line complete all as directed. Make : H GURU /Dwyer / Forbes Marshall / Warrie
Supply and fixing 50mm bore tube light grade steel water tubing with and including all GI fittings laid in trenches or fixed to wall/ceiling complete all as specified and directed.
S&F Fiber glass reinforced translucent corrugated /plane sheeting 2 mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as directed.
S&F rolled mild steel in Joist, channel, angle, or tee sections Fe 410 -W (Gde-E- 250) quality A, fixed independently, without connecting plates including dismantling existing old steel member, etc complete all as directed.
Demolition of Cement concrete (unreinforced) in ground floors of any thickness (below or above ground level) and removal of unserviceable material out side MoD land upto distance exceeding 1.5Km but n.exc 3Km complete all as directed.
Supply and fix sluice valve Cast iron body steel spindle flange type with iron wheel of size 200 mm PN-1.6 of drain pipe of SWT No 1 and 2 at approx 7 feet below GL at ETH including dismantling and taking out old unserviceable sluice valve and repairing of the valve pit and PCC floor to match the adjoining surface complete all as directed. Note : Sluice valve to be replaced at 7 feet below normal ground level
M&L for cutting holes into or through cement concrete walls or slabs n.exc 300mm thick reinforced or otherwise for superficial area n exc 100 sqcm complete all as directed.
M&L for cutting holes into or through cement concrete walls or slabs n.exc 300mm thick reinforced or otherwise for superficial area exc 100 sqcm but n.exc 250Sqcm complete all as directed.
M&L for cutting holes into or through cement concrete walls or slabs n.exc 300mm thick reinforced or otherwise for superficial area exc 250 sqcm but n.exc 500Sqcm complete all as directed.
S&F Wire netting of stainless steel wire 1.4mm dia size of wire mesh 12 mm fixed with tinned tacks of stainless steel wire staples complete all as directed Note for item ser no 44 to 47 : Work to be done at the height of 25 mtr from ground level in VK 2500-03 test cell bldg
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement including dismantling old, complete all as specified and directed.
S&F rolled mild steel in Plates (plain or chequered) channels-, Fe- 410 W Grade E-250 quality A square cut or notched (ordinary and counter sunk) forming holes, without any attachment including dismantling old existing member complete all as specified and directed
M&L for taking out GI tubes of size 80 mm, any grade from trenches/outside trenches and cleaning and re-laying including cutting to required length, threading and connecting with new GI fittings heavy duty (socket, nipple, union, bend elbow and reducer etc ) as required at site any type. Note : Cost of GI fittings and cutting/threading of pipe is deemed to be included in the quoted rates.
M&L for taking out GI tubes of size 100 mm, any grade from trenches/outside trenches and cleaning and re-laying including cutting to required length, threading and connecting with new GI fittings heavy duty (socket, nipple, union, bend elbow and reducer etc ) as required at site any type. Note : Cost of GI fittings and cutting/threading of pipe is deemed to be included in the quoted rates.
Supply and fixing in replacement of cast iron/DI fitting for soketed/ flanged pipes up to 200 mm bore such as bends, tapers, tee pieces (single & double branch) any type and angle tapers any type (straight, bends, increasing, decreasing or double socket etc) Tee branch single branch, 'Y' junction, double branch cross collars caps and plugs up to 200mm bore as required at site complete all as specified and directed.
Note:- Amount of credit of Rs 180100.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
PARTAP ENGINEERING WORKS
M/s badrinath Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .