Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC VILL POST RANI PIND DISTT HOSHIRPUR PUNJAB PIN 144202 BRANCH OFFICE MAILING ADDRESS 121 LANE 8 UPPERSIDE GREATER KAILASH JAMMU 18001 | HOSHIARPUR | PUNJAB | 144202 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹37.0 L+₹6.0 L (19.3%)Rejected-Finance NEAR OLD INDIAN OIL DEPOT JALANDHAR JAMMU BYE PASS ROAD PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹38.8 L+₹7.8 L (25.2%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹39.7 L+₹8.7 L (28.0%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹42.8 L+₹11.8 L (38.2%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
Refer Docs
EMD Value
₹83,060
Closing Date
18 Dec 2023, 6:00 pmClosed
GE (SOUTH) PATHANKOT
GE (SOUTH) PATHANKOT
SPL REP TO BLDG NO NP 54 PROVN OF GYSERES STANDBY UNDERGROUND CABLE AND ALLIED WORKS PROVN OF COOLER STAND AT MIL STN UNCHIBASSI UNDER GE SOUTH PATHANKOT
2023_MES_629979_1
GES/PKT/T-36/2023-24
Open Tender
Construction Works
Item Rate
180 days
GE (SOUTH) PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (SOUTH) PATHANKOT
₹83,060
Yes
29 Feb 2024
25 Nov 2023
20 Dec 2023
25 Nov 2023
18 Dec 2023
11 Dec 2023
Amount
Demolition of brick work/ stone masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified.
M&L for Brick work with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified.
Brick work with sub class ‘B’ bricks, straight or curved on plan any radius in half brick thick wall with old size bricks built in cement mortar 1:4 complete all as specified.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for Rendering 15mm thick in CM 1:4 using liquid water proofing compound on brick work or concrete surfaces on wall, surfaces finished even and smooth using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately under respective item).
M&L for Rendering 10 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for Rendering 10 mm thick in cement and sand mortar 1:3 using liquid water proofing compound on brick work or concrete surfaces of wall/ floor in sunken portion, surfaces finished even and smooth using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately under respective item)
M&L for Rendering 10 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling/Top and sides of chajjas/facia of roof projection incl necessary formwork including finishing the surface even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound.
M&L for Preparation of newly plastered/ prepared surfaces of walls and applying 1mm thick wall care putty with two coats of Oil Bound Distemper over a coat of primer to match the shade as per existing colour scheme/pattern complete all as specified and directed.
M&L for Preparation of newly plastered/ prepared surfaces of walls and applying two coats of cement base paint over a coat of primer to match the shade as per existing colour scheme/pattern complete all as specified and directed.
M&L for preparation of newly plastered external surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint (Weather coat) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm (weather proof/weather coat) without any brush marks on the surface in any colour over including necessary scaffolding up to three storeys height of bldgs,Shade/colour shall be approved by GE,all painted areas site to be cleaned and hand over as earlier without any extra cost to Govt complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.
M&L for complete removal of existing treatment from ceiling surface and applying two coat of white wash on undecorated surfaces without any brush marks on the surface including necessary scaffolding up to four storeys height of bldgs if required complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Filling of sunken floor with PCC 1:5:10 using 40mm graded crushed stone aggregate including breaking and removal of existing filling of lime concrete/PCC/brick bats and rubbish out off the premises, etc complete all as specified and directed.
M & L for Two Coats of Hot bitumen on newly plastered surface of sunken portion complete all as specified and directed.
S & F for Steel water tubing light grade 40mm dia, galvanised, including short lengths, fixed as spout as in walls of sunken portion of toilets complete all as specified and directed.
M & L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified.
S & F for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified.
S & F for Glazed coloured ceramic tile 450 x 300 x 7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified.
M&L for Non - skid Ceramic joint free tiles 7 to 8 mm thick coloured/wooden finish (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified.
M&L for Non - skid Ceramic joint free tiles 7 to 8 mm thick coloured/wooden finish (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc.
M & L For 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win?dow-cills, cooking plat?forms and like in cement mortar (1:4) including point?ing in white cement (1:2) us?ing marble dust with admix?ture of pigment to match with shade of granite complete all as specified.
Round chamfering, to the edges of marble slabs complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and directed.
All as per Srl item No. 28 above, but area exceeding 1.5 sqm and not exceeding 4.00 sqm each, complete all as specified and directed.
S&F for Pressed steel frames of size 105 x 60 mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, incl filling of PCC 1:3:6 type C-1 using 12.5mm graded stone aggregate as in frames/hold fast blocks complete all as specified and directed.
S & F for Pressed steel frames of size 125 x 60 mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, incl filling of PCC 1:3:6 type C-1 using 12.5mm graded stone aggregate as in frames/hold fast blocks complete all as specified and directed.
S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
S & F for Factory made solid panel PVC door shutter 30 mm thick both side prelaminated with coloured paint (style) consisting of frame made out of M.S. tubes for top & bottom rails complete all as specified and directed.
S & F for Factory made 35 mm thick, 2nd Class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F for Factory made 30 mm thick, 2nd Class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc, supplied and fitted to chowkats complete all as specified and directed.
S&F 18/19mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed.
M&L 2nd class hard wood, plain fillets, square, rectangular or triangular in section, bullnosed, wrought, secured with nails or brads, sectional area exe 13.0 sqcm but n. exc 25 sqcm.
S & F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, door shutters; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, complete all as specified and directed.
S & F for Z-Section Steel windows/ ventilators with side hung shutters including projecting type hinges with 2 Nos steel handle, 2 Nos Tower Bolt and 01 No steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed.
All as per Srl Item No 39 above but without glazing bars.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps (cooler stand for ground Floor & 1st Floor) including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified.
Painting to newly surfaces of wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with two coat of synthetic enamel paint over a coat of pink primer complete all as specified.
Preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint complete all as specified and directed.
M&L for Painting to old painted surfaces of wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with two coats of synthetic enamel paint to match the shade as per existing colour scheme/pattern complete all as specified and directed.
M&L for Preparation of old painted steel surfaces of any description exc 10 cm width or girth and painting with two coats of synthetic enamel paint to match the shade as per existing colour scheme/pattern complete all as specified and directed.
S & F for Stainless steel Butt Hinges, 100 mm long medium weight, complete all as specified.
S & F for 300mm long Stainless steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixedwith hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section complete all as specified.
S & F for 150mm long, Stainless steel barrel tower bolts, stove enaqmelled black, with bright bolt and fixed complete all as specified.
S & F Stainless steel pressed handles, oval type, stove enamelled black complete all as specified & directed.
S & F for continous (Piano) type hinges Stainless steel bright finish or electrogalvanised with wide of flaps 40mm, complete all as specified & directed.
S & F for 300 mm size Stainless steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified.
S & F 150mm Overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & directed.
S & F for 40 mm dia, cupboard knobs fixed with nut, screw and washer of Stainless steel, bright finished complete all as specified.
Hasp and staple of size 100 mm, safety type, Stainless steel , wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips and providing and fixing new ones glazed with oil putty fixed with beads or in wooden shutters complete all as specified and as directed.
S & F for 03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified.
S & F for 03 mm thick figured (frosted) glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified.
S & F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
All as per the description of item No.66 above but fixed in repair.
S&F Rotational moulded polyethlene water storage tanks of capacity 500 litres three layers (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling of existing PVC tank of any capacity complete all as specified & directed.
S&F 20mm dia for Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed, complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store for 15mm bore complete all as specified and directed.
All as per Item No 62 Above but 20mm bore.
S&F for Steel water tubing medium grade, galvanised, including short lengths, fixed to wall/concealed in wall/ceiling or laid in floor complete with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc, of 15mm bore complete all as specified and directed by EIC.
All as per Item No 64 Above but 20mm bore.
Refixing of old Steel water tubing and connections in new or old position medium grade, galvanised, including short lengths, fixed to wall/concealed in wall/ceiling or laid in floor complete with all fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc, of 15mm bore complete all as specified and directed by EIC.
All as per Item No 66 Above but 20mm bore.
S & F for Vitreous China squatting pan “Orissa pattern” size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with CI ‘P’ trap of long arm of suitable size including connection to flush pipe, anti symphonic pipes etc fixed in repairs, complete all as specified.
S & F for PVC low level flushing cistern, valveless, syphonic action type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 60/90 cm long etc, supplied and fixed in repairs, complete all as specified.
S & F for Vitreous china wash hand basin (flat back or angle back type), size 550 x 400mm including cutting for and pinning in ends of brackets or erecting stand incl waste pipe fixed in repairs complete all as specified and directed.
S & F for CP Brass Centre Hole, wash basin Mixture tap, cast copper alloy, with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15mm bore complete all as specified and directed.
S & F for CP Brass Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm bore fixed in repair complete all as specified and directed.
S & F for Stop/Angle valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair for 15mm bore complete all as specified and directed.
S & F for Stop/Angle valves, cast copper alloy, Chromium plated with long shank and cup (Concealed type) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair for 15mm bore complete all as specified and directed.
S & F for Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair for 20mm bore complete all as specified and directed.
S & F for Grating doom 100mm dia of PTMT (Minimum weight 25gms)
S&F for Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms)
S & F for PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed complete all as specified.
S & F for Stainless steel towel rail 20mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and directed.
S & F for Soap dish, Stainless steel, approximate size 160x 160x90mm complete all as specified and directed.
S & F for Shower Rose Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) complete all as specified and directed.
S&F Waste pipe of low or high density or PVC. 32 mm dia for Kitchen Sink & Wash basin complete all as specified and directed.
S & F for Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats fixed in repair complete all as specified and directed by EIC.
S&F 20 mm bore stainless steel curtain rod with 1 mm thick wall thickness and each length not more than 1.8 Metre including a pair of brackets and knobs with each length/ piece, fixed on doors and windows opening for hanging curtains complete all as specified and directed.
S & F for PVC (SWR) pipes single socketed in any length with rubber ring joints fixed in trenches/floors/walls for 75 mm bore of pipe fixed in repair complete all as specified and directed.
All as per Srl Item No 86 Above but 110mm bore of pipe.
S & F for PVC (SWR) floor bend, plain including jointing with solvent cement 75 mm bore in repairs complete all as specified.
All as per Srl Item No 88 Above but 110mm bore of pipe.
S & F for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore in repairs complete all as specified.
Cutting holes in brick walls built in cement mortar or cement lime mortar and making good the dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required for exc half brick but n exc one brick thick wall complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate on roof slab including finishing the top surface even & smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided as slab,RCC Water Tank, cover etc. for complete all as specified and directed. (reinforcement cut as required to facilitate demolition)
Mild steel TMT bars 10 mm dia and over, quality conforming to Grade 415 MPA cut to length , bent to shape required including cranking , bending and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Providing cement concrete Type B-2, 1:2:4 (40 mm graded crushed stone aggregate) for walls or retaining walls, any thickness, size or shape incl. pilasters and post (incl. caps and bases), complete all as specified and directed. Incl water proofibg compound (Note : WPC shall be measured and paid separately under respective item).
Providing Reinforced cement concrete Type B-1, 1:2:4 (20 mm graded crushed stone aggregate) as in Slabs supported on walls, landings, balconies, canopies, deck slabs and in shelves and the like incl necessary form work etc, complete all as specified and directed.
S & F for bath cabinet of size not less than 300mmx450mm x75mm deep with standard size of glass complete all as specified and directed.
S & F sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing with cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repair incl waste coupling and excluding waste pipe complete all as specified and directed.
S & F for Stainless steel plate rack of size 900 x 600 mm not less than 1mm thick fixed with bracket, screw and necessary arrangements fixed in repair complete all as specified and directed.
PCC 1:2:4 type B-2 using 20mm graded crushed stone aggregates as in surface channels and drains complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex-tra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed.
S&F for water heater storage vertical type, SS tank, polycarbonate body electrical operated, capacity 25 litres.BEE 5 star rated duly fixed on wall through proper anchoring, grouting with the help of suitable nuts and bolts, and making good all the disturbed surface all as specifed and directed by the Engr In charge.
S&F for sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
M&L for GI tubing medium grade of 15 mm dia complete all as specified and directed.
Cutting existing steel tubing for alteration including screwing in position for branch connecting size 15/20/25mm bore complete.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm suitable for hot and cold water all as specified and directed
S&F brass angle valve, cromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union of 15 mm dia.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of size 15 mm dia all as specified and directed
S&F in replacement iron clad, with double door 4 way IP-54, 1K-09 protection, cement sprill prptector sutable for MCCB as incommmer AC 415 Volts three pole with thermal release adjustable type (80% to 100%) and MCB as outgoing complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 ple 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at sit or directed. ( Outgoing MCB will be measured speparately)
S&F for SPN 40 to 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
S&F for 50mm GI tubing light grade ISI marked with requisite fittings laid in trenches or crossing roads/paths/ culverts/along poles/walls, complete all as specified and directed.
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, complete all as specified and directed.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables, Foundation filling of poles or stays.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available, laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
Cutting the tarmac/ hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C2 50mm thick matching with the surroundings all as directed.
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 50 Sq mm 3.5 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 50 Sqmm 3.5/4 core with working voltage 1100 volts.
Material, labour, testing & commissioning of cable end termination in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 10 Sqmm to 25 sqmm 3½ or 4 core with working voltage 1100 volts.
Taking down carefully copper/aluminium point wiring (light/Fan socket or power) with complete fittings such as switch, sockets Ceiling rose pendent holders regulators etc. Removing old/UNSV material from site and making good the old disturbed surface.
M&L for point wiring with PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge (Phase Neutral and earth wire shall be provided in standard colour code R,Y,B for phase, Black for neutral green for earth wire). Note In ceiling Portion surface conduit wiring shall be carried out.
All as per srl item No 124 above but for One light point or one fan point or bell point controlled by one switch SP one way 230 Volts.
All as per srl item No 124 above but for One light point controlled by Two-2 way switches with cable 1.5 Sqmm size,
All as per srl item No 124 above but for One 3 pin socket out let 5/6 Amps on same board.
All as per srl item No 124 above but for One socket out let 5/6 Amps on Independent board.
All as per srl item No 124.04 above but for 15/16 Amps socket out let independent with 4.0 sqmm copper conductor
M&L for switch Piano flush type single pole one way 5/6 Amp
M&L for switch Piano flush type single pole Two way 5/6 Amps
M&L for switch,socket combination 2 in 1 , 3 pin, 5 and 15 Amp flush type, complete all as specified and directed.
M&L for switch, socket combination 3 pin, 5 Amp flush type, complete all as specified and directed.
M&L for socket outlet 2 in 1, 3 pin, 5 Amp flush type, complete all as specified and directed.
S&F for fan regulator capacitive type suitable for BLDC fan, complete all as specified and directed.
M& L for bell push flush type 5/6 amp, complete all as specified and directed.
S&F for Buzzer Ding Dong, AC 230 volt single pole, complete all as specified and directed.
M&L for ceiling rose 2-3 terminal size 65x20mm, complete all as specified and directed.
S&F lamp holder Angle type insulated body with back plate for batten fitting, fixing with proper round block, complete all as specified and directed.
S&F in replacement sheet metal enclosure with DB's (grouted in walls) double door type for MCB's 08 ways with 200 Amps 240 volts rated bus bar, complete all as specified and directed.
S&F in replacement existing unsv distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge
S&F for 6 to 32 Amps MCB SP ( ISI Marked) 50 C/S 10 KA 'C' sereis, rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning and all as specified and directed
S&F for 6 to 32 Amps MCB SPN ( ISI Marked) 50 C/S 10 KA 'C' sereis, rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning and all as specified and directed.
S&F for replacement inverter type LED fitting 1x20W LED including LED tube 4 feet long having bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
S&F for replacement existing UNSV decorative box type fitting 4 feet long with LED tube light fitting 20 watt complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
S&F for replacement existing unsv integrated LED bulk head light fitting 1X10 watts IP-65 protection connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
S&F for replacement existing unsv sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long of same make having ballast, bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
S&F inverter type LED Lamp 10 watt 230 volts complete all as specififed and directed.
Taking down Exhaust fan, Ceiling fan complete with its acessories and keeping in safte custody for refitting/depositing to MESc store
S&F for replacement of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. with brushless direct current motor (BLDC) without remote complete all as specified and as directed.
S&F for ventilation fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed.
S&F for exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and as directed.
S&F for desert cooler electric driven Steel body) with the following specificaitonFan Size - 20",Fan Speed - 1400 Rpm, 3 Speed, Motor - 180 Watts Copper Winding,Pump - 18 Watts Submersible, Pads - Wood Wool. Power - 220V, 15Hz, Cabinet Size - 26" x 26" x 34" (L x W x H) Finish - Powder Coated, Water Capacity - 60 Ltrs.
Diconneting electrical connection form the electric energy meter and meter box and keeping in safe custody for refixing,
Fixing of electric meter after the completion of Civil work complete making its electric connection complete along with its meter box all as specified and directed by Engr-in-Charge
M&L for Sub main wiring in PVC concealed conduit with 2 Nos single core PVC insulated copper conductor cable FRLS size 4 sqmm multistrand in concealed conduit with 4 sqmm PVC insulated FRLS as earth continuity wire using suitable size of copper thimble including provn of PVC coduit heavy duty ISI marked of adequate size.
M&L for Sub main wiring in PVC concealed conduit with 2 Nos single core PVC insulated copper conductor cable FRLS size 6 sqmm multistrand in concealed conduit with 6 sqmm PVC insulated FRLS as earth continuity wire using suitable size of copper thimble including provn of PVC coduit heavy duty ISI marked of adequate size.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical, plate No. 5 connected to earthing test point all as specified or indicated including testing on completion.
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
M/S ANSHUL ENTERPRISES
M/S KLM ENTERPRISES
M/S SHRI RAM BUILDERS
Jay Ann Construction Company
S S CONSTRUCTION
kailu construction co
JAI DURGA CONSTRUCTION CO
M/S CHAMAN LAL GUPTA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .