Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC VPO BAILLY TEH DALHOUSIE DISTT CHAMBA HP 176303 | DALHOUSIE | CHAMBA | HIMACHAL PRADESH | 176303 | L1 | Accepted-AOC Being Lowest L1 | |
| 2 | L2₹28.9 L+₹1.3 L (4.65%)Rejected-Finance NEAR CIVIL HOSPITAL VILLAGE PO CHOWARI DISTT CHAMBA HP | CHOWARI | CHAMBA | HIMACHAL PRADESH | 176302 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹30.0 L+₹2.4 L (8.70%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹31.3 L+₹3.8 L (13.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹34.1 L+₹6.6 L (23.9%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
25 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PATHANKOT
GE (AF) PATHANKOT-145001
REPAIR TO CERTAIN BUILDING AT BAKROTA AT AIR FORCE STATION DALHOUSIE
2021_MES_472964_1
8420/GE/PAF-39/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE (AF) PATHANKOT
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) PATHANKOT
₹87,000
13 Oct 2021
4 Sept 2021
27 Sept 2021
4 Sept 2021
25 Sept 2021
11 Sept 2021
60 days
Amount
Demolition of Brickwork or Stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by the Engineer-in-Charge.
Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM (1:6) with old size bricks complete all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks half brick thick straight or curved on plan to any radius in half brick walls built in CM(1:4) complete all as specified and directed by Engineer-in-Charge.
Taking down cement plasters on brick or conc surfaces incl racking out joints, hacking for key complete all as specified and directed by Engineer-in-Charge.
Rendering 15mm thick cement plaster in CM (1:4) on brick or conc surfaces finished and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50 m and making good surface, work in soft disintergreted rock complete all as specified and directed by Engineer-in-Charge.
PCC 1:4:8 Type D-2 40 mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wooden framed trusses/beam/purliens N exc 10 m complete all as specified and directed by Engineer-in-Charge.
Rolled mild steel plates in roof trusses (frramed) trussed, Purlins, crane gantries, rails and framing (beam, tee angle, channel or flat sections) including distance pieaces cleats etc. Fe 410-w (gde E 250) quality B complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Fe 410-w(Gde E 250) quality A rolled mild steel in framed work as in doors or gates and grills of angle or other section with gusset plates rails braces etc, complete, drilled for fixing of steel sheeting or other covering doors, etc to be brepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering running rails and guides and hanging also fastening and fixing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of MS plates plain or chequered square cut or notched forming holes drilled or welded any thickness complete all as specified and directed by Engineer-in-Charge.
Dismantling Plain or corrugated steel sheeting any gauge, thickness including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of 0.63mm thick galvanised, corrugated mild steel sheeting with two corrrugations side lap, fixed with coach screws and washers in roofs, wall etc. with grade of zinc coating 275 complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 0.63mm thick galvanised, plain mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed by Engineer-in-Charge.
Preparation of new or previously untreated surfaces of steel or iron any description, over 10cm in width or girth,not otherwise described and two coats of synthatic enamel paint over red oxiede primer complete all as specified and directed by Engineer-in-Charge.
Dismantiling tiles flooring/dado, hearth including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premised complete all as specified and as directed by Engineer-in-Charge
Non Skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and include 15 mm thick screed bed in CM 1:6, complete all as specified and directed by Engineer-in-Charge.
Glazed ceramic coloured, tiles 300x200x6-7mm or 450x300x6-7mm thick in vertical surfaces such as skirting,dados and risers to steps over and including 10mm thick in CM (1:4), complete all as specified and directed by Engineer-in-Charge.
Virified ceramic tiles 10 mm thick(square/rectangular) polished size of tiles 600x600x10 mm , in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and include 15 mm thick secreed bed in CM 1:4complete all as specified and directed by Engineer-in-Charge.
Dismantling old Wall and ceiling boards (fiber, pulp insulation /slabs /blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of anodised GI snap grid frame work for false ceiling complete all as specified and directed by Engineer-in-Charge.
Non-asbetos ceiling board 0.595 x0.595 mtr x 4mm thick designer boards fixed with powder coated GI framing including drilling hole for fixing GI frame including 4mm GI wire suspender and clips as complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of anodised aluminium powder coating minimum thickness of powder coating 50 micron frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of anodised aluminium powder coating minimum thickness of powder coating 50 micron door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber packing, anodised aluminium snap beading screws etc, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of 4 mm thick tinted/plain glass for aluminium windows/doors having each pane exc 0.5 sqm incl complete all as specified and directed by Engineer-in-Charge.
Preparation of new surfaces and applying distempering two coat on walls and with oil bond distemper, white or tinted over and including 5 mm thick chalk whiting on plastered surfaces complete all as specified and directed by Engineer in Charge.
Supply and fixing of Collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottem runner, brass handles etc, as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories of single/three phase complete all as specified and directed by Engineer-in-Charge.
Concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead/telephone socket etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:- (a) one light/fan point controlled by one switch one way.
(b) One 5 Amp socket point controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge.
(c) one 5 Amp independent socket point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per item No 94 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by Engineer-in-Charge.
Switch flush type single pole one way 5 Amps, 240 volts, white finish, ISI marked complete all as specified and directed by Engineer-in-Charge.
Socket outlet 5 pin, 5 Amps, 240volts flush type white finish , ISI marked complete all as specified and directed by Engineer-in-Charge.
Ceiling rose, surface backlite, 65 x 20 mm 3three terminal ISI Marked complete all as specified and directed by Engineer-in-Charge.
Socket outlet 2 in 1, 3 pin, 5 &15 A, 240 volts, flush type white finish, ISI Marked complete all as specified and directed by Engineer-in-Charge.
Switch flush type single pole one way 15 Amps, 240 volts, white finish, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Bell push, flush type 5 Amps white finish, ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Door bell multi music type 230V, single pole, ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Lamp holder insulated body with back plate suitable for angle / batten fitting ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Sheet metal enclosure VTPN MCCB DB 12 way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB when MCBs & MCCB 100 Amps (as incomer) fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 12 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of MCB SP 240 volt 6 to 32 Amps, 240 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed by Engineer-in-Charge.
All as per item No 42 above but SPN 16-32 Amps, 240 Volts, 10 KA.complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of MCCB 100 Amps, 3 Pole, 415V, 25 KA thermal adjustable type with short circuit and overload protection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of sheet metal enclosure , 32A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly complete all as directed by Engr-in-Charge.
Sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10 sqmm drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc laid in concealed position with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed by Engineer-in-Charge.
Decorative ultra slim linear LED lighting fixtures with extruded polycorbonate envirnmental friendly energy saver LED light fitting 1x20/22 watt (4'), 230 Volts, single tube mounting including LED Tube 20/22 Watt complete with industrial grade heavy duty electronic driver spring loaded rotory type lamp holder, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection three core copper cable from ceiling rose to led light fitting complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 above but 1x10/12 Watt (2') complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of recess mounting LED luminaries 34/36 Watt(2'x2'), 240 volts with more light distribtuion and clutter free ceiling with powder coated CRCA sheet steel white powder coated housing with square in a perforated metallic frame complete all as specified and directed by the Engr-in-charge.
Supply and fixing of decorative ultra slim linear LED lighting fixtures with extruded polycorbonate environmental friendly energy saver LED light fitting 1x20/22 watt (4'), 230 Volts, single tube mounting including LED Tube 20/22 Watt complete with electronic driver spring loaded rotory type lamp holder, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection with three core copper cable from ceiling rose to led light fitting all complete all as specified and directed by the Engr-in-charge.
Supply and fixing building security light fitting new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 of 25 watt LED, 240 Volts complete all as specified and directed by the Engr-in-charge.
Supply, fixing, installation and testing of ISI marked, energy efficient, water heater storage type, electrically operated, single phase, 50 Hz (BEE 5 star rating), complete of 25 Ltr capacity with and including supply and fixing, wire armoured 450 mm long, 15 mm dia brass coupler etc, flexible pipe suitable to withstand upto 100 degree celcius for hot and cold water, anchor fastner - 04 Nos of suitable size , 3 core PVC insulated, FRLS multistranded copper conductor cable and plug top 15 Amps capacity complete in all respect all as specified and directed by Engr-in-Charge. Note : Old unserviceable geyser is to be deposited to MES store yard.
Supply and fix heavy duty exhaust fan AC single phase 230/240 V of size 300 mm sweep 1400 RPM with louver & shutter including necessary grouting on wall complete and making good the wall surface after fixing of exhaust fan all as specified and directed by the Engr-in-charge. Note : Old unserviceable Exhaust fan is to be deposited to MES store yard.
Supply and fix PVC exhaust fan AC single phase 230/240 V of size 250 mm sweep 1400 RPM with louver & shutter including necessary grouting on wall complete and making good the wall surface after fixing of exhaust fan complete all as specified and directed by the Engr-in-charge.
Earthing complete with copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below ;normal ground level ) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to copper strip 20X3 mm as earth lead by means of bolts, nuts washers and check nuts of steel/GI duly protected with 40 mm bore light grade pipe upto main board , 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation , earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, add charcoal dust and common salt after mixing with BFC (Back Fill Compound) inadeqate quantity as recommended by the manufacturer or as diirectred by the Engr-in-charge all as shown in electrical plate No. 03 of SSR part-I 2009 having pit in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for CI cover of required size, funnel with wire mesh complete and all as specified and as directed by Engr-in-charge.
Supply and fixing of copper strip 20x3mm complete with saddles/ insulators made out of PVC or fibre and fixing screws for roof conductor/down conductor including welding or brazing for joints complete all as specified and directed by Engineer-in-Charge.
Supply, laying testing and connecting 25 Sqmm 3.5 Core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade laid in trenches/ducts/wall or through pipe with suitable size of cable glands, crimping type cable lugs complete all as specified and directed by Engr-in-Charge. all respect and all as specified and directed by Engr-in-Charge.
Supply, laying testing and connecting 70 Sqmm 3.5 Core XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electrical cable with aluminium conductor, 1100 volts grade laid in trenches/ducts/wall or through pipe with suitable size of cable glands, crimping type cable lugs complete all as specified and directed by Engr-in-Charge.
Supply and fixing of GI tubing light grade 50mm bore laid in trenches, ducts, floor for protection of cable, fixed to wall or poles including fixing arrangement all as required and directed by Engineer-in-Charge.
Supply and fixing of GI tubing light grade 25mm dia, cut to size and bent to shape all as required at site including fixing arrangement with necessary clamps of required size at site and providing appropriate size of insulators to pipe from foundation of air termination rod complete all as specified and directed by Engr-in-charge.
Air termination single pointed copper rod 12mm dia and 300mm long complete including fixing arrangement as per site requirement complete all as specified and directed by Engineer-in-Charge.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 03 Nos 8mm dia 25mm long hex head screw complete and all as specified and as directed by Engr-in-charge.
m/S Varun Gupta
Surya & Gautam Builders
M/s. Rishav Sood
M/S HARBANS SINGH BEDI
SAMTA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .