Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹420 (<0.01%)Rejected-AOC | ₹1.6 Cr+₹420 (<0.01%) | L2 | Rejected-AOC L2 |
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
29 Jan 2020, 4:30 pmClosed
J.M. Basumatary
O/o Addl. C.E. PWD cum-CHD Director Kokrajhar
Construction of Class Room and Renovation under RUSA Grant for Bijni College Bijni under Chirang District BTAD Assam. TN No.99
2020_BTC_15898_1
ACE-74/NIT/RUSA/2
Open Tender
Civil Works - Building
Item Rate
425 days
Bijni
Refer to SBD
6 documents required · 6 mandatory
₹4,750
Yes
Principal Secretary BTC Kokrajhar
₹3.1 L
Yes
13 May 2020
14 Jan 2020
30 Jan 2020
14 Jan 2020
29 Jan 2020
14 Jan 2020
14 Jan 2020 - 29 Jan 2020
Amount
Construction of classroom building (Ground Floor) technologically enabled CIVIL WORKS: EARTH WORK 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2m below the existing ground level. (a) In ordinari soils
1.2 Earth/sand filling in plinth un layer not more than 150mm thick including necessary, carriage, watering, rammimng etc. complerte as directed and specified, including payment of land compensation, forest royalty, Sale Tax and other duties and taxes as may be necessary. (C ) With river sand or silts (Predominantly non-plastic) by truck carriage including loading and unloading.
Cement concrete works: 2.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately) (a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume.
2.2 Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarseagg. Of size 13mm to 32mm includingdewatering if necessary and curing etc. compete. (iii) 100mm thick.
2.3 Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc.complete as directed.
2.2.1 Providing and laying plain/reinforced cement concrete work, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (a) In substructre up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (P) Using admixture, plasticiser etc for air entraining, water reducing purpose including addition of agent for changing normal setting time of concrete as required. (b) M20 grade concrete or peop 1:1.5:3
2.2.1 Providing and laying plain/reinforced cement concrete work, cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (B) In Supar structure from plinth level upto 1st floor level. (ii) Column, pillars, post, struts, suspended floor, roof, landing, shelf and support balcony, lintel, sill band beam girder, bressumer, cantilever, staiecase(exceptspiral staircase and landing)including preparing the top surface and finishing of noising. (P) Using admixture, plasticiser etc. (b) M20 grade concrete or prop 1:1.5:3
Providing form work of 12mm thick plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of proping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
3.1 Providing form works of 12mm thick plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of proping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: (i) Columns, pillars, posts & Strut of suqare rectangular/polygonal in plan or any shape like Tee/L etc. having place vertical face.
10.1 Sides and soffits of Beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
11.1 Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
4.1 Providing soiling in foundation and under floors at all levels with best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete. (a) Brick on flat soling.
13.1 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In sub-structure up to plinth level. Including dewatering if necessary (c ) In proportion 1:5
4.3 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth upto 1st floor level. (Protruding M.S. rod/Tor steel of columns to be embedded in cement mortar and will be measured and paid for separately.) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4 (1 cement: 4 sand)
5.7.2.1 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and trads of steps over 15mm thick base of cement mortar in prop. 1:3 (1cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite /Rouf)/ white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the deptt.) (a) Normal range Somany/Orient/Nitco/Varmora/VITA/Marbito/Make
16.1 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the deptt.). (Walls means both interior and exterior walls) (a) Normal range Somany/Orient/Nitco/Asian make (ii) Of size 200mm X 200mm and above
17.1 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 ( 1 cement : 3 coarse sand ) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement complete at all levels as specified and directed.
6.2.1 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
19.1 15mm thick cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b) On fair side.
20.1 20mm thick cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) On rough side (breaking coat 15mm and finishing coat 5mm thick) (b) In cement mortar 1:4
21.1 Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessaryhinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20 X 20 X 1.25mm thick. frame to be filled up with 1:4:8 P.C.C. after fitting with brick/concrete works etc. complete as directed by the deptt. for all levels. (P.C.C. to be measured and paid for separately). (a) 1.25mm thick sheet (ii) Size 105mm X 60mm (Single rebate)
22.1 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S. code including oxidised iron butt hinges (100mm X 75mm X 3.5mm) 6 nos with necessary wood screws. (a) decorative type face panel and block board core. (ii) 35mm thick.
Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with roundheaded bolts and nuts or screws. I. Plain grill. (c ) Fixed to brickwork/P.C.C/R.C.C.
24.1 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevent IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc., as required complete as specified and directed for all levels. (a) 2 Track sliding window (ii) 5mm frosted glass
25.1 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the deptt. (Total thickness of two coats in maximum 1.5mm) 9i) Thickness= 1.5mm thick
26.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint) Nerolac) on new surface to give an even shade after throughly brushing brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Acrylic Emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/Nerolac)
27.1 Applying primary coat over new steel and other metal surface over 1000m in wdith or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/red oxide" primer.
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. (b) High gloss (Asian paint/Berger paint/ICI paint/J & N paint/ Nerolac).
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (a) Sliding door bolts (i) 300mm X 16mm
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (b) Tower bolts (i) 300mm X 12mm
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (c ) Door handles (iii) 150mm
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (m ) Mortice lock vertical type (iii) 100mm (Godrej) with handle (6-lever)
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks.supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be enternained in the measurement as they are included in the rate) (Upto 1st floor level) (a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINIL (ii) Super Ductile (SD) TMT reinforcement bars.
Providing drain with cement concrete (1:3:6) 10mm thick sides 10 cm thick bed over brick flat soling including 15mm thick cement plastering in prop 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work. (ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Sanitary and water supply. Supplying, fitting and fixing recessed soap tray of Hindware make complete as directed and specified. (i) Recess SP & SG dish (Cat. No. C9935)
Providing, fitting and fixing towel rail of Sona make complete as directed and specified. (a) Chorme plated towel rail 600mm long.
Supplying, fitting and fixing PVC pipes of 6 kgf/cSq.M (Supreme/Prince) or other ISI approved including joining, fitting and fixing clamp etc. as necessary complete at all levels including below GL as directed and specified. (a) In exposed surface or in trenches. (I) 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 kgf/cSq.M (Supreme/Prince) or other ISI approved including joining, fitting and fixing clamp etc. as necessary complete at all levels including below GL as directed and specified. (a) In exposed surface or in trenches. (ii) 75mm dia.
Supplying, fitting and fixing PVC bend I.S.I approved (87.5 degree) including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (a) 110mm dia
Supplying, fitting and fixing PVC bend ISI approved (87.5 degree) including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (b) 75mm dia.
Supplying, fitting and fixing P.V.C. plain tee I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surface or in trenches. (a) 110mm dia
Supplying, fitting and fixing P.V.C. plain tee I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surface or in trenches. (b) 75mm dia
Supplying, fitting and fixing P.V.C. single Y I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surface or in trenches. (a) 110mm dia.
Supplying, fitting and fixing P.V.C. single Y I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surface or in trenches. (b) 75mm dia.
(a) Providing, fitting and fixing 75mm dia PVC cowel with ISI make complete as directed and specified.
Supplying, fitting and fixing 450mm dia X 90mm thick C.I. manhole cover & frame of 19 Kg weight as directed and specified.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up to the trench up of the trench with brick bats/dry chaocoal covered with earth over a layer of A.C. plain sheets above brick bats filling as directed.
Construction of inspection pit inside measurement 450mm X 450mm X 450mm clear top, flushed with 100mm dia PVC pipe cement concrete base prop 1:3:6 over flat brick soling 12cm brick wall in cement mortar prop 1:4 finished with 13mm cement plaster prop 1:2 on side walls and floor and 450mm X 450mm airtight C.I. inspection pit cover and frame complete including supplying of materials necessary excavation of pit as directed.
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (a) 40mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (b) 32mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (c ) 25mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C and making good to the damaged structure TATA (medium) (a) 32mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C and making good to the damaged structure TATA (medium) (b) 25mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C and making good to the damaged structure TATA (medium) (c ) 15mm dia
Supplying, fitting and fixing C.P. bibcock 15mm dia of approved as directed and specified. (G.I. & C.P. pipes will be measured separately). (i) Bib cock short body, Essco make
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I pipes will be measured separately). (a) 15mm dia (wt. 400gms)
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I pipes will be measured separately). (b) 25mm dia (wt. 1250gms)
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I pipes will be measured separately). (c ) 32mm dia I.S.I marked
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I pipes will be measured separately). (d ) 40mm dia I.S.I marked
Supplying and placing plastic cylindrical vertical closed top (PCVC) tank of Sintex make over the staging with manhole cover with locking arrangements and cleaning arrangements including providing pads of sizes as required for inlet and outlet pipes complete as directed. (a) 1000 litres capacity
Deep Tube Well: Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the department. (i) Bore hole of 150mm diameter.
Supplying, fitting and fixing pipes (Pain/bevel ended) for casing, conforming to relevent I.S. codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole by the department. (i) G.I. pipe, TATA/SAIL (medium, sockets should be welded to the pipes.) (a) 100mm diameter
Supplying, fitting and fixing of suction pipes (plain/bevel ended) conforming to relevent I.S. code of practice including supplying and fixing of accessories, loweing of assembly pipes concentrically in the casing pipes complete as directed. (i) G.I. pipe, TATA/SAIL (medium, sockets should be welded to the pipes.) 40mm diameter.
Supplying, fitting and fixing G.I. filter 2.00m long.
Development of tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained.
Flushing cleaning, washing and watering of tube well
Supplying including fitting & fixing of watersupply motor pumpset mono block type complete with all accessories C.C foundation of proportion 1:2:4 jammed with M.S. nuts and bolts including D.O.L starter and making necessary connection etc. as reqd. complete. (a) 1 H.P. Single phase
Electrical Works: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1. Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 2. Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 2. Long point up to 10.00 metre. length.
1.2 Wiring to 5 a pin 6 Amps plug point with 1.5 sq mm P.V.C. insulated single core unsheated industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed to electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/Nicco/Anchor or Equivalent make as approved by the Deptt.) with flat19mm ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor Penta/Gold medal/ kolor kany.com/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq mm cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Long point up to 10.00 metre length.
1.3 Wiring for 5/6 pin 16 Amps power plug point with 4 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /R.R. Kabel/ Nicco/ Anchor or Equivalent make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/precision/Presto Plast/ Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin in 16Amps flush type socket outlets and 16 Amps flush type switch (Anchor Penta /Gold medal/ kolor kany.com/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, earth continuity with 2.5 sq mm cable to 3rd pin of the socket as required complete. Long point up to 10.00 metre length.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. With 2 X 2.5 sq.mm + earth continuity with 1 X 1.5 sq.mm in 20mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. With 2 X 4 sq.mm + earth continuity with 1 X 2.5 sq.mm in 20mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
1.9 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Depft.) in surface with flat ISI marked casing 'n' capping (AKG / Preoision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 3 X 4 sq. mm + earth continuity with 2 X 2.5 sq.mm cable in flat 25mm ISI marked casing 'n' capping system.
11.10 Supplying and fixing of batten holder (Anchor Penta PC CHERRY/Gold medal/Kolor.kom/Havells or equivalent make as approved by the deptt.) including connection as approved by the deptt. ) as required without lamp.
11.22 Supplying and fixing of 250/305mm dia (Nominal size flush type circular ceiling fitting complete with holder, Aluminium anodized back plate and brass holder, 20 Watt CFL lamp including connection as approved by the deptt.) as required.
15.1 Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar na din rail etc fitted on wall with grounting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 12 way SPN single door.
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the folloowing capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 6 to 32A
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B series (ABB, Schneider MG, lrgrand, hager make) 6 to 32A
16.35 Supplying with fitting and fixing 4P 10KA 240/415V 50HZ MCB of the following capacity complete with making necessary connection as approved, specified and directed by the department. C Series (Schneider neo break, C&S, Havells, Indo Asian, HPL, V-Guard or equivalent make as approved by the deptt. 63A
16.40 Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 3P MCCP (Ics=Icu, adjustable lr setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved by the deptt.) as specified and directed by the deptt. 25KA 415V 50Hz 3p MCCB (Havells, HOPL, Indo Asian make) 125A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt (5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper. Earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the deptt.) as required complete and as directed by the department [Without regulator] Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. Havells make)
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the deptt.) as required complete and as directed by the deptt. Power Flow 225mm sweep (Orient make)
27.6 Supplying fitting and fixing of ceilling fan regulator including connections etc. complete as required. Electronic type
32.1.3 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq. mm balance stranded conductor , Xlpe insulated , cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq. mm balance Aluminium strip, Galvanised for cables up to 2 X 10 sq. mm 3 X 10 sq. mm, 4 X 6 sq. mm balance all galvanised steel strip), extruded PVC Type ST 2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling protective brick covering, sand cushioning etc. complete handling of surplus spoil, debries to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make) 3& 1/2 Core A2xfy 35.00 sq.mm 3&1/2 Core armoured U.G cable (For service line)
ECBC 3.15.24 Supplying including installation, testing and commissioning of different type of LED LUMINARIES as directed an specified by the department. SM440L 15 X LED-HB/RD 24V CQC, CE VAYA COVE MONO, RGB, 0.3 M CQC/CE/UL TRADE PACK
ECBC 3.23.3 Supplying and fixing of jaquare or equivalent Philips/Wipro LED wall light fittings complete with cable, as approved by the deptt. Etc. as required. LED Bulk Head 8W
Payment to be made to APDCL authority for Load security and Meter security for single phase service connection.
CONSTRUCTION OF COMPUTER CENTER AND SEMINAR BUILDING CIVIL WORKS: EARTH WORK 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc. including refilling(return filling) the quantity as necessary after completing of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2m below the existing ground level. (a) In ordinari soils
1.2 Earth/sand filling in plinth un layer not more than 150mm thick including necessary, carriage, watering, rammimng etc. complerte as directed and specified, including payment of land compensation, forest royalty, Sale Tax and other duties and taxes as may be necessary. (C ) With river sand or silts (Predominantly non-plastic) by truck carriage including loading and unloading.
2.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately) (a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume.
2.2 Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarseagg. Of size 13mm to 32mm includingdewatering if necessary and curing etc. compete.
2.3 Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. Of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc.complete as directed.
2.2.1 Providing and laying plain/reinforced cement concrete work, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (a) In substructre up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (P) Using admixture, plasticiser etc for air entraining, water reducing purpose including addition of agent for changing normal setting time of concrete as required. (b) M20 grade concrete or peop 1:1.5:3
2.2.1 Providing and laying plain/reinforced cement concrete work, cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using mixture machine (B) In Supar structure from plinth level upto 1st floor level. (ii) Column, pillars, post, struts, suspended floor, roof, landing, shelf and support balcony, lintel, sill band beam girder, bressumer, cantilever, staiecase(exceptspiral staircase and landing)including preparing the top surface and finishing of noising. (P) Using admixture, plasticiser etc. (b) M20 grade concrete or prop 1:1.5:3
Providing form work of 12mm thick plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of proping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
3.1 Providing form works of 12mm thick plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of proping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: (i) Columns, pillars, posts & Strut of suqare rectangular/polygonal in plan or any shape like Tee/L etc. having place vertical face.
10.1 Sides and soffits of Beams, beam haunching, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
11.1 Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
4.1 Providing soiling in foundation and under floors at all levels with best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete. (a) Brick on flat soling.
13.1 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In sub-structure up to plinth level. Including dewatering if necessary (c ) In proportion 1:5
4.3 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth upto 1st floor level. (Protruding M.S. rod/Tor steel of columns to be embedded in cement mortar and will be measured and paid for separately.) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4 (1 cement: 4 sand)
5.7.2.1 Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and trads of steps over 15mm thick base of cement mortar in prop. 1:3 (1cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite /Rouf)/ white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the deptt.) (a) Normal range Somany/Orient/Nitco/Varmora/VITA/Marbito/Make
16.1 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10mm thick in prop. 1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the deptt.). (Walls means both interior and exterior walls) (a) Normal range Somany/Orient/Nitco/Asian make (ii) Of size 200mm X 200mm and above
17.1 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 ( 1 cement : 3 coarse sand ) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement complete at all levels as specified and directed.
6.2.1 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
19.1 15mm thick cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b) On fair side. (b) In cement mortar 1:4
20.1 20mm thick cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) On rough side (breaking coat 15mm and finishing coat 5mm thick) (b) In cement mortar 1:4
21.1 Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/1.6mm thick sheet of various sizes with necessaryhinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20 X 20 X 1.25mm thick. frame to be filled up with 1:4:8 P.C.C. after fitting with brick/concrete works etc. complete as directed by the deptt. for all levels. (P.C.C. to be measured and paid for separately). (a) 1.25mm thick sheet (ii) Size 105mm X 60mm (Single rebate)
22.1 Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S. code including oxidised iron butt hinges (100mm X 75mm X 3.5mm) 6 nos with necessary wood screws. (a) decorative type face panel and block board core. (ii) 35mm thick.
Providing fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with roundheaded bolts and nuts or screws. I. Plain grill. (c ) Fixed to brickwork/P.C.C/R.C.C.
24.1 Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevent IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc., as required complete as specified and directed for all levels. (a) 2 Track sliding window (ii) 5mm frosted glass
25.1 Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the deptt. (Total thickness of two coats in maximum 1.5mm) 9i) Thickness= 1.5mm thick
26.1 Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint) Nerolac) on new surface to give an even shade after throughly brushing brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Acrylic Emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/Nerolac)
27.1 Applying primary coat over new steel and other metal surface over 1000m in wdith or girth after preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/red oxide" primer.
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. (b) High gloss (Asian paint/Berger paint/ICI paint/J & N paint/ Nerolac).
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (a) Sliding door bolts (i) 300mm X 16mm
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (b) Tower bolts (i) 300mm X 12mm
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (c ) Door handles (iii) 150mm
6.8 Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paints of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & N paint/Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (m ) Mortice lock vertical type (iii) 100mm (Godrej) with handle (6-lever)
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks.supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be enternained in the measurement as they are included in the rate) (Upto 1st floor level) (a) From Primary Producer: TATA/SAIL/Esser Steel/Jindal steel/Shyam steel/RINIL (ii) Super Ductile (SD) TMT reinforcement bars.
Providing drain with cement concrete (1:3:6) 10mm thick sides 10 cm thick bed over brick flat soling including 15mm thick cement plastering in prop 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work. (ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing plinth protection with bricks flat laid in cement mortar 1:4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Sanitary and water supply: Plumbings: Supplying, fitting and fixing recessed soap tray of Hindware make complete as directed and specified. (i) Recess SP & SG dish (Cat. No. C9935)
Providing, fitting and fixing towel rail of Sona make complete as directed and specified. (a) Chorme plated towel rail 600mm long.
Supplying, fitting and fixing PVC pipes of 6 kgf/cSq.M (Supreme/Prince) or other ISI approved including joining, fitting and fixing clamp etc. as necessary complete at all levels including below GL as directed and specified. (a) In exposed surface or in trenches. (I) 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 kgf/cSq.M (Supreme/Prince) or other ISI approved including joining, fitting and fixing clamp etc. as necessary complete at all levels including below GL as directed and specified. (a) In exposed surface or in trenches. (ii) 75mm dia.
Supplying, fitting and fixing PVC bend ISI approved (87.5 degree) including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (a) 110mm dia
Supplying, fitting and fixing PVC bend ISI approved (87.5 degree) including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (b) 75mm dia.
Supplying, fitting and fixing P.V.C. plain tee I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surface or in trenches. (a) 110mm dia
Supplying, fitting and fixing P.V.C. plain tee I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surface or in trenches. (b) 75mm dia
Supplying, fitting and fixing P.V.C. single Y I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surface or in trenches. (a) 110mm dia.
Supplying, fitting and fixing P.V.C. single Y I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surface or in trenches. (b) 75mm dia.
(a) Providing, fitting and fixing 75mm dia PVC cowel with ISI make complete as directed and specified.
Supplying, fitting and fixing 450mm dia X 90mm thick C.I. manhole cover & frame of 19 Kg weight as directed and specified.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up to the trench up of the trench with brick bats/dry chaocoal covered with earth over a layer of A.C. plain sheets above brick bats filling as directed.
Construction of inspection pit inside measurement 450mm X 450mm X 450mm clear top, flushed with 100mm dia PVC pipe cement concrete base prop 1:3:6 over flat brick soling 12cm brick wall in cement mortar prop 1:4 finished with 13mm cement plaster prop 1:2 on side walls and floor and 450mm X 450mm airtight C.I. inspection pit cover and frame complete including supplying of materials necessary excavation of pit as directed.
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (a) 40mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (b) 32mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (c ) 25mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C and making good to the damaged structure TATA (medium) (a) 32mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C and making good to the damaged structure TATA (medium) (b) 25mm dia
Supplying, fitting and fixing GI pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple plug, long screw fitting HW clamp etc complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C and making good to the damaged structure TATA (medium) (c ) 15mm dia
Supplying, fitting and fixing C.P. bibcock 15mm dia of approved as directed and specified. (G.I. & C.P. pipes will be measured separately). (i) Bib cock short body, Essco make
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I pipes will be measured separately). (a) 15mm dia (wt. 400gms)
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I pipes will be measured separately). (b) 25mm dia (wt. 1250gms)
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I pipes will be measured separately). (c ) 32mm dia I.S.I marked
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I pipes will be measured separately). (d ) 40mm dia I.S.I marked
Supplying and placing plastic cylindrical vertical closed top (PCVC) tank of Sintex make over the staging with manhole cover with locking arrangements and cleaning arrangements including providing pads of sizes as required for inlet and outlet pipes complete as directed. (a) 1000 litres capacity
Deep Tube Well: Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the department. (i) Bore hole of 150mm diameter.
Supplying, fitting and fixing pipes (Pain/bevel ended) for casing, conforming to relevent I.S. codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole by the department. (i) G.I. pipe, TATA/SAIL (medium, sockets should be welded to the pipes.) (a) 100mm diameter
Supplying, fitting and fixing of suction pipes (plain/bevel ended) conforming to relevent I.S. code of practice including supplying and fixing of accessories, loweing of assembly pipes concentrically in the casing pipes complete as directed. (i) G.I. pipe, TATA/SAIL (medium, sockets should be welded to the pipes.) 40mm diameter.
Supplying, fitting and fixing G.I. filter 2.00m long.
Development of tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained.
Flushing cleaning, washing and watering of tube well
Supplying including fitting & fixing of watersupply motor pumpset mono block type complete with all accessories C.C foundation of proportion 1:2:4 jammed with M.S. nuts and bolts including D.O.L starter and making necessary connection etc. as reqd. complete. (a) 1 H.P. Single phase
Electrical Works: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1. Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 2. Medium point up to 6.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 3. Long point up to 10.00 metre. length.
1.2 Wiring to 5 a pin 6 Amps plug point with 1.5 sq mm P.V.C. insulated single core unsheated industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed to electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel/Nicco/Anchor or Equivalent make as approved by the Deptt.) with flat19mm ISI marked casing 'n' capping (AKG/precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor Penta/Gold medal/ kolor kany.com/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq mm cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Long point up to 10.00 metre length.
1.3 Wiring for 5/6 pin 16 Amps power plug point with 4 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /R.R. Kabel/ Nicco/ Anchor or Equivalent make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/precision/Presto Plast/ Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including providing and fixing 5/6 pin in 16Amps flush type socket outlets and 16 Amps flush type switch (Anchor Penta /Gold medal/ kolor kany.com/ Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, earth continuity with 2.5 sq mm cable to 3rd pin of the socket as required complete. Long point up to 10.00 metre length.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. With 2 X 2.5 sq.mm + earth continuity with 1 X 1.5 sq.mm in 20mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. With 2 X 4 sq.mm + earth continuity with 1 X 2.5 sq.mm in 20mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
1.9 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Depft.) in surface with flat ISI marked casing 'n' capping (AKG / Preoision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity. With 3 X 4 sq. mm + earth continuity with 2 X 2.5 sq.mm cable in flat 25mm ISI marked casing 'n' capping system.
11.10 Supplying and fixing of batten holder (Anchor Penta PC CHERRY/Gold medal/Kolor.kom/Havells or equivalent make as approved by the deptt.) including connection as approved by the deptt. ) as required without lamp.
15.1 Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar na din rail etc fitted on wall with grounting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 12 way SPN single door.
16.1 Supplying with fitting and fixing single pole 10 KA 240/415V 50Hz MCB of the folloowing capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager make) 6 to 32A
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B series (ABB, Schneider MG, lrgrand, hager make) 6 to 32A
16.35 Supplying with fitting and fixing 4P 10KA 240/415V 50HZ MCB of the following capacity complete with making necessary connection as approved, specified and directed by the department. C Series (Schneider neo break, C&S, Havells, Indo Asian, HPL, V-Guard or equivalent make as approved by the deptt. 63A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt (5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper. Earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
27.1 Supplying including fitting fixing of following A.C. Ceilling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the deptt.) as required complete and as directed by the department [Without regulator] Premium model 1400 mm sweep. (ORIENT PSPO make) /Premium model 1400 mm sweep ss-390 Deco. Havells make)
27.6 Supplying fitting and fixing of ceilling fan regulator including connections etc. complete as required. Electronic type
32.1.3 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq. mm balance stranded conductor , Xlpe insulated , cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq. mm balance Aluminium strip, Galvanised for cables up to 2 X 10 sq. mm 3 X 10 sq. mm, 4 X 6 sq. mm balance all galvanised steel strip), extruded PVC Type ST 2 sheathed, 650/1100V grade as per IS 7908 (Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling protective brick covering, sand cushioning etc. complete handling of surplus spoil, debries to proper place as specified and directed by the deptt. (Nicco/Havells/RPG/CCI/Polycab/Gloster/Finolex make) 3 & 1/2 Core A2xfy 25.00 sq.mm 2 Core armoured U.G cable (For service line)
ECBC 3.15.24 Supplying including installation, testing and commissioning of different type of LED LUMINARIES as directed an specified by the department. SM440L 15 X LED-HB/RD 24V CQC, CE VAYA COVE MONO, RGB, 0.3 M CQC/CE/UL TRADE PACK
ECBC 3.23.3 Supplying and fixing of jaquare or equivalent Philips/Wipro LED wall light fittings complete with cable, as approved by the deptt. Etc. as required. LED Bulk Head 8W
Payment to be made to APDCL authority for Load security and Meter security for single phase service connection.
CAMPUS DEVELOPMENT: 1.1 Earth work in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling(return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Upto a depth of 2.00m below the existing ground level. i) In ordinary soil
1.2 Earth/sand filling in plinth in layer not more than 150mm thick including necessary, carriage, watering, rammimng etc. complerte as directed and specified, including payment of land compensation, forest royalty, Sale Tax and other duties and taxes as may be necessary. (c ) With river sand or silts (predominantly non-plastic) by truck carriage including loading and unloading.
2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete( shuttering where necessary shall be measured and paid separately ) (b) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
Shuttering: 3.1 Providing form works of 12mm thick plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of proping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: (i) Sides and soffits of beams, beam haunchings cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
Brick Work: 4.1 Providing soiling in foundation and under floors at all levels with best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete. (a) Brick on flat soling.
4.2 Providing drain with brick work in cement mortor in proportion 1:5 with half brick thick side walls and 100mm thick C.C. (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Construction of sub-grade and earthen shoulders with approved materials obtained from borrow pits, with all lifts & leads, transporting to site, spreading grading to required slope and compacting to meet requirement of table 300-2 (including compensation of earth). (Including cost of testing of materials at site and laboratory as directed by the deptt.)
Construction of Granular sub-base by providing close graded materials, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achive the desired density, complete as per Clause 401 of MoRTH specification (with an initial lead of 5Km) including cost of testing of materials at site and laboratory as directed by the deptt.)
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/running/herringbone pattern of bonds as directed by the enginner and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and technical specification clause 1504 of MORD.
Miscelleneous.
Upgradation of Existing Library facilities by Automating the Library using RFID technology: COST OF APPLIENCES: RFID Tags/Book Labels Frequency Support 13.56 MHz Standard ISO 15693 complaint Type: i-code SLIX Complaint. Memory Capacity: 1024 bits Data re-write 100000 times for wach address Anti-collision for Multi read 100000 Transactions Size of tag: 49mm X 81mm
HF RFID Smart Cards Operating Frequency: 13.56MHz Standard : ISO 15693 Memory: 1KB Typical Programming cycles (at 25c) 100000 Simultaneous indemtification of tags : upto 50 tags per second (Reader/Antenna dependant) Case Material: PVC, white Surface Finish: Glossy Dimensions : 85.6(L) X 54(W) X 0.76 (Thickness) mm (ISO 7810) Weight: 5gms Printability: Thermal transfer (Dey Sublimation preferred).
Staff Station with Softwere. RFID Reader with integrated Antenna The firmware should be ISO 15693 complaint and should be upgradeable to comply with future ISO 18000 RFID chips Antenna: Capability to multiple read Operating frequency: 13.56MHz Chip Compactibility: code2 and ISO 15693 Chips Accompanied with the necessary software, Communication interface : serial RS23 Note: Reader and Antenne should be single module
RFID Security Gate (Two panels) Library EAS Security arrangement with provision for camera Dual lane gantry should consist of three pedestals freqency support: 13.56MHz Gate width: 1.80m transmitting power: 10w reading should be 3 dimensional supperting transponder: ISO 15693 complaint controllable volume for alarm storbe light alarm count patron traffic counter
University logo Stickers for Book (Anti-theft stickers) Adhesive paper sticker should be soft with logo printed over it
Dual Side Card Printer with softwere, card Design work to be done by vendor Color printing module 300 dpi print head (11.8 dots/mm) USB and Ethernet TCP-IP connections 16 MB RAM Flip-over station for dual-sided printing Detachable feeder with a capacity of 100 cards (0.76 mm- 30mil) Output hopper with a capacity of 100 cards (0.76mm- 30mil) 1-Button and 4-LED control panel Print Moder: Color dye sublimation and monochrome thermal transfer.
RFID Web based Application, software integration with existing LMS and installation and training Web Based application having following features User and User Management Tagging information of items Patron information Item information Block Unblock Member card Reset PIN Tagging Item List Card Issue List Not Tagged item list Card not Issue list INventory Status Missing item list Dislocated item list Inventory history item issue return report of all KIOSK or individual KIOSK that install in library
UPGRADATION OF TOILET BLOCK: SANITARY FIXTURES EUROPEAN TYPE WATER CLOSET 1.2 Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead , CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make/a) White/(vii) Niagara (Cat No.C0252) (inclusive of seat cover)
PVC FLUSHING CISTERN: 1.5 Supplying, fitting and fixing PVC flushing cistern with all internal fittngs with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) (i) Parryware make, (a) White (i) Economy Single Flush (Cat No. C8090/C8055)
WASH BASIN: 1.13 Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) (1.13.1) PEDESTAL BASIN (with pedestal) (A) Parryware Make/(a)nWhite (iv) Casecade NXT 550 X 440 with long Pedestal (Cat No. C0404/C0380
MIRROR 1.18 Providing fitting and fixing mirror with plastic frame of size 500 X 400mm complete as directed and specified.
SOAP TRAY, SOAP DISH, LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER: 1.23 Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified. (i) Jaquar make (a) Continental (Cat No. CAN-1135N) (with glass bottle)
ROBE HOOK 1.27 Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. (Jaquar make/ (i) Continental (Cat No. CAN-1191N)
TOILET PAPER HOLDER 1.31 Providing, fitting and fixing Chrome plated TOILET PAPER holder complete as directed and specified. (a) Jaquare make/ (i) Continental toilet paper holder (Cat No. CAN-1151N)
WASTE COUPLING 1.32 Providing, fitting and fixing Chrome plated waste coupling complete as directed and specified. (a) Jaquare make/ (i) 32mm (HT/FT) (Cat No. ALD-705/709)
TOWEL RAIN, TOWEL RACK & TOWEL RING 1.26 Providing, fitting and fixing chrome plated towel ring complete as directed. (a) Jaquare make (ii) Continental towel ring round (Cat No. CAN-1121BN)
1.33 Providing, fitting and fixing chrome plated bopttle trap complete as directed and specified. (a) Jaquare make. (ii) Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat No. ALD-769B)
BIB COCK 3.2.1 Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P. pipes will be measured separately) (II) Jaquare make/ (a) Continental/ Clarion (i) Standard
STOP COCK 3.3.2 Supplying fitting and fixing chrome plated (C.P.) stop cock of approved brand and size as mentioned below as directed and specified. (G.I. & C.P. pipes will be measured and paid separately) (I) Jaquare/ (a) Continental/ Clarion (ii) 15mm dia (Angular stop cock)
PVC PIPES, BEBDS, JUNCTIONS, TEES ETC. 1.37.1 Supplying,fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (a )In exposed surfaces or in trenches. (i) 160mm dia.
1.37.1 Supplying,fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia
1.37.1 Supplying,fitting and fixing PVC pipes of 6 kg/cm2 (Supreme/Prince) or other ISI approved including joining, fitting and fixing with clamps etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 50mm dia
1.37.2 Supplying,fitting and fixing 87.5 degree PVC bend with door of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C. and making good to the damages. (v) 50mm dia
1.37.4 Supplying fitting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (ii) 110mm dia
1.37.4 Supplying fitting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (iv) 75mm dia
1.37.4 Supplying fitting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages (v) 50mm dia
1.37.5 Supplying fitting and fixing PVC plain single tee of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed as specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C. and making good to the damages. (ii) 110mm dia
1.37.5 Supplying fitting and fixing PVC plain single tee of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed as specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C. and making good to the damages. (iv) 50mm dia
1.37.6 Supplying fitting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed as specified. (a) In exposed surfaces or in trenches. (ii) 110mm dia.
1.37.15 Supplying fitting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed as specified. (b) Concealed by chiselling or breaking brick wall/ C.C./ R.C.C and making good to the damages. (iii) 110mm X 75mm
1.37.7 Supplying fitting and fixing PVC single 'Y' of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C. and making good to the damages. (ii) 110mm dia.
1.37.14 Supplying fitting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. (b) Concealed by chiselling or breaking brick wall/C.C./R.C.C. and making good to the damages. (iv) 110mm X 75mm
1.39 Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110 mm dia. PVC cowel of ISI make
1.4 Providing fitting & fixing C.I. Grating to the floors complete as directed and specified. (a) 110mm dia.
3.1.6 Providing and fixing Chlorinated Polyvinyle chloride(CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00mm spacing. This includes jointing of pipe. (A) Exposed or in trenches (e) 40mm nominal outer dia pipe
3.1.6 Providing and fixing Chlorinated Polyvinyle chloride(CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00mm spacing. This includes jointing of pipe. (A) Exposed or in trenches (f) 50mm nominal outer dia pipe
3.1.6 Providing and fixing Chlorinated Polyvinyle chloride(CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00mm spacing. This includes jointing of pipe. (B) Concealed pipe with cutting chases & making good the walls. (a) 15mm nominal outer dia pipe
3.1.6 Providing and fixing Chlorinated Polyvinyle chloride(CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00mm spacing. This includes jointing of pipe. (B) Concealed pipe with cutting chases & making good the walls. (b) 20mm nominal outer dia pipe
3.1.6 Providing and fixing Chlorinated Polyvinyle chloride(CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00mm spacing. This includes jointing of pipe. (B) Concealed pipe with cutting chases & making good the walls. c) 25 mm nominal outer dia pipe
3.1.6 Providing and fixing Chlorinated Polyvinyle chloride(CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00mm spacing. This includes jointing of pipe. (B) Concealed pipe with cutting chases & making good the walls. d) 32 mm nominal outer dia pipe
3.1.6 Providing and fixing Chlorinated Polyvinyle chloride(CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00mm spacing. This includes jointing of pipe. (B) Concealed pipe with cutting chases & making good the walls. e) 40 mm nominal outer dia pipe
3.1.6 Providing and fixing Chlorinated Polyvinyle chloride(CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the clamps at 1.00mm spacing. This includes jointing of pipe. (B) Concealed pipe with cutting chases & making good the walls. f) 50 mm nominal outer dia pipe
VALVE 3.17.1 Supplying and fitting gun metal country pit value I.S.I Make as specified and directed. a) 50mm dia
3.17.1 Supplying and fitting gun metal country pit value I.S.I Make as specified and directed. b) 40mm dia
3.17.2 Supplying and fitting ball valve as specified and directed. (a) 25mm dia (gun metal)
5.4.2 Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex/Polycon/Patton make over the stagging with manhole cover with locking and clearing arrangement including providing pads of size as required for inlet and outlet pipes. (I) 2000 Lt capacity (a) Sintex make
Providing and fixing SS floor clean out plug comprising of uPVC pipe, socket, elbow, extension piece caulked to pipe , complete as required. (i) For 110mm dia pipe.
CIVIL WORK: EARTHWORK IN EXCAVATION: 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling(return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to adepth of 2.00 below the existing ground level. (a) In ordinary soil
1.3 Earth/Sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
PLAIN CEMENT CONCRETE WORKS: 2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete. (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
2.1.3 Providing and laying 25mm thick damp proof couarse with cement concrete in Prop : 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacture including curing etc. complete as directed.
2.2 REINFORCED CEMENT CONCRETE WORKS 2.2.1 Providing and laying plain/reinforced cement concrete work cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (a) In substructre up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture, plasticizer. (a) M15 grade concrete or prop 1:2:4
2.2.1 Providing and laying plain/reinforced cement concrete work cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (a) In substructre up to plinth level. (B) In Supar structure from plinth level upto 1st floor level. (i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. (N) Without using admixture, plasticiser (a) M15 grade concrete or prop 1:2:4
TIMBER SHUTTERING (FORMWORK) 3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.1 Foundation, footing, bases of columns, pile cap, raft and mass concrete work etc. (b) Using 25mm thick plank
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.2 Slides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank
PLYWOOD SHUTTERING (FORMWORK) 3.2.1 Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.1 Column, pillars, posts & struct of square/rectangular/Polygonal in plain or any shape like Tee/L etc having plane vertical face.
3.2.1 Providing form work of 12mm thick plywood board so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.2 Sides and soffits of beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M
MASONARY WORKS: 4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. a) Brick flat soling.
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (d) In proportion 1:6
4.1.8 1st class brick wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level. (A) 112mm thick brick wall (a) In cement moratar in proportion 1:4(1 cement : 4sand)
FLOORING & FLOOR FINISHED TILES WORKS CERAMIC TILES B) ON WALLS 5.7.1.2 Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less then 8mm on wall and skirtings over cement mortar bed 10mm thick in prop. 1:3(1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Title (Choksey/Sika/Pedelite/Rouf)/ White cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) (Walls means both interior and exterior walls) c) Delux range Somany/Orient/Nitco/Varmora Make (iv) Of size 300mm X 600mm and above
ANTISKID TILES 5.11.1 Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1cement : 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all levels as specified and directed. (A) CERMIC (iii) Executive range-2 (Size 600mm X 600mm and above) Somany made-VC shield (Group-25) (65 X 605)mm (b) Delux-Rotto VC
PLASTERING CEMENT PLASTERING 6.2.1 10mm thick cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (b) In cement mortar 1:4
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm girth and finished even and smooth including curing complete as directed. (A) On rough side. (b) In cement mortar 1:4
6.2.5 Exra over item no 6.2.1 to 6.2.2 for plastering on ceiling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
FALSE CEILING 7.10.1 Providing and fixing, in position suspended false ceiling using E-Gird (exposed ceiling suspension 2430 system) of gired size 600mm X 600mm/1200mm X 600mm with main runner 38 X 24mm, cross tee 29mm X 24mm & wall angle 24mm X 24mm. Using 4mm/6mm thick High Presure Steam Cured Non Asbestors Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/.................. (A) Standard Ceilings of Everest make or equivalent as directed by the department (ii) Using 6mm thick FC Board
ROOFING 8.1.33 Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/ SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia X 3mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc. to be measured and paid separately) (b) 0.50 mm thick.
M.S. GRILL 10.2 Providing, fitting and fixing M.S. grill of required pattern for windows/clerestory window/opening with M.S. flat at required spacing in frame all round, square or round M.S. bars with roundheaded bolts and nuts or screws. I. Plain grill (C ) Fixed to Brickwork/P.C.C./R.C.C.
ALUMINIUM WINDOWS AND VENTILATORS 11.1.3 Providing, fitting and fixing coloured anodized aluminium windows and ventilators of standered sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifications) fitted with 6mm X 3.15mm lugs 100mm long embedded in CC blocks 150mm X 100mm X 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and apid separately). (a) Side hung and top hung windows and ventilators (i) 6mm clear glass
11.1.3 Providing, fitting and fixing coloured anodized aluminium windows and ventilators of standered sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevent IS specifications) fitted with 6mm X 3.15mm lugs 100mm long embedded in CC blocks 150mm X 100mm X 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and apid separately). (b) Fixed windows and ventilators (i) 6mm clear glass
PAINTING 13.4.7 Wall painting (two coats) with plastic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac) on new surface to give an even shade after thoroughly brushing the surface free from morter dropping and other foreign matter and sand papered smooth. (a) Plastic emulsion paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
SPECIAL WEATHER PROOF COLOURING 13.9.4 Finishing old/ new wall with water proofing weather coat smooth anti-fungle premium acrylic exterior finish of Snowcryl XT brand of snowcem India Ltd. Of required shade after clearing and cleaning the surface etc. of required shade after clering and clearing the surfaces etc. including scaffolding complete as directed at all levels (two coats).
PAINTING ON STEEL AND OTHER METAL SURFACE 13.7.2 Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly clearing oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/red oxide" primer.
13.7.4 Painting two coats (excluding priming coat) on new steel and other metal surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac paint) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or girth. (a) General purpose (Asian paint/Berger paint/ICI paint/ J&N paint/Nerolac).
DOOR AND WINDOW/FITINGS ALUMINIUM FITTINGS 15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished) (a) Sliding door bolts (ii) 250mm X 16mm
15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished) (b) Tower bolts (iii) 200mm X 12mm
15.2.1 Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete. (anodised to bright natural matt & stain finished) (c ) Door handles (ii) 100mm
STEEL AND IRON WORKS REINFORCEMENT 18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, spacers etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THEREMAX) (For Assam Type Bldge., drain works, retaining wall & boundary wall etc.
ROOF TRUSS 18.3.1 providing, fitting, hoisting and fixing of roof trusses including purlins fabricated using M.S. circular hollow section conforming to relevent I.S. code, as per approved design and drawings including providing M.S. cleats, baseplates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. b) Using other ISI marked approved circular hollow section
PVC DOORS 12.3 Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mm X 60mm (Toletance + l rnm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mm X 100mm or plastic brackels of size 75mm X 75mm with metred cut at the corners. Hinge side of the frame shall be reinforced wiih M.S.Tubular section of size 40mm X 20mm. The frame will be fixed to the column/ stiffner/.............
12.4 Providing fitting and fixing PVC Door shutters of Duroplast DPS 3720 make made from extruded PVC stiles and rails made from rigid PVC multicavity hollow chember section of size 90mm X 37mm (Toletance + 1mm) . The corners of the stiles and rails shall be metred out and fixed to each other with the help of solid plastic L-shaped brackets or M.S. rectangular tubular ................
SEPTIC TANK EARTH WORK IN EXCAVATION: 1.1 Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling(return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. A) Upto a depth of 2.00m below the existing ground level. i) In ordinary soil
2.1 PLAIN CEMENT CONCRETE WORKS 2.1.1 Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick work etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement :3 sand : 6 coarse aggregate by volume.
2.2.1 Providing and laying plain/reinforced cement concrete work, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (a) In substructre up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture. plasticiser. (a) M15 grade concrete or prop 1:2:4
2.2.1 Providing and laying plain/reinforced cement concrete work, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (a) In substructre up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. (N) Without using admixture. plasticiser. (b) M20 grade concrete or peop 1:1.5:3
TIMBER SHUTTERING (FORMWORK) 3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.1 Foundation, footing, bases of columns, pile cap, raft and mass concrete work etc. (b) Using 25mm thick plank
3.1.1 Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in situ reinforced concrete and plain concrete work in. 3.1.1.2 Sides of the beams grade beams etc. at or below ground level. (b) Using 25mm thick plank
PLYBOARD SHUTTERING (FORMWORK) 3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.3 Flat surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) floors etc. upto 200mm in thickness.
3.2.1 Providing form work of 12mm thick plywood board so as to given a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: 3.2.1.6 Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
4.1.1 Providing soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. a) Brick flat soling
4.1.4 Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (i) In sub-structure up to plinth level including dewatering if necessary (d) In proportion
6.2.2 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arises, internal roundred angels, not execeeding 80mm in curing finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4
Neat Cement Punning
REINFORCEMENT: 18.1.1 Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S code for R.C.C. work/ R.B. willing including straightening cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chair, anchor etc. complete (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THEREMAX) (For Assam Type Bldge., drain works, retaining wall & boundary wall etc.
Electrical Works: 1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 1. Short point up to 3.00 metre. length.
1.1 Wiring for light/fan/ call bell point with 2 x 1.5 sq mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or Equivalent Make as approved by the Deptt.) with flat 19mm ISI marked casing 'n' capping (AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/bell push (Anchor Penta/Gold medal/ Kolor kany.kom/havells or equivalent make as approved by the deptt.) G.I/MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover, ceiling rose (Anchor/Gold medal/kolor kany.kom/Havells or equivalent make as approved by the Deptt.) etc. complete as directed and specified by the deptt. 2. Medium point up to 6.00 metre. length.
2.7 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kable/Nicco/Anchor or equivalent make as approved by the deptt.)PVC conduit (Berlia/AKG/Precision/Presto Plast/Polycab/MW or equivalent make as approved by the deptt.) including earth continuity in surface/recessed 20 mm dia 2mm thick/heavy ISI marked IS: 9537 PART- III rigid PVC conduit wiring system. With 2 X 2.5 sq.mm + earth continuity with 1 X 1.5 sq.mm in 20mm dia. 2mm thick/heavy rigid PVC IS: 9537 Part- III conduit.
11.10 Supplying and fixing of batten holder (Anchor Penta PC CHERRY/Gold medal/Kolor.kom/Havells or equivalent make as approved by the deptt.) including connection as approved by the deptt. ) as required without lamp.
16.3 Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B series (ABB, Schneider MG, lrgrand, hager make) 6 to 32A
22.7 Supply, installation & testing of G.I. earth station with perforated 40mm dia and 4.50 Metre long heavy duty G.I. pipe with necessary 40mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm X 40mm G.I. reducing socket for funnel including locking arrangement 300mm X 300mm X 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the department.
22.12 Extra for using salt (5Kg and Charcoal 64 k in pipe earth station pit to provide low impendence ground in location of high soil resistivity as and when required and specified by the Deptt.
22.16 Supplying & laying with 8 SWG copper. Earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
11.18 Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the deptt. As required.
11.26 Supplying and fitting of 18/20 watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/pendent holder etc. as specified and directed by the deptt.
UPGRADATION OF SCIENCE LABORATORY: Plain cement concrete floor base in prop 1:3:6 laid in alternate bays as specified with coarse agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. complete. (iii) 100mm thick
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop. 1:3 ( 1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Siak /Pedelite /Rouf)/White cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separstely). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the department) (a) Normal range (Size 600mm X 600mm)
5.7.1.1 Providing ceramic tiles of approved quality, size, shape and thickness not less than 8mm thickness on floors, skirting, treads and risers of steps over cement mortar bed 15mm thick in prop1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/Sika/Pedelite/Rouf/White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the department). Normal range Somany/Orient/Nitco/Asian Make At floors Of size 300mm X 300mm and above
5.7.1.1 Providing ceramic tiles of approved quality, size, shape and thickness not less than 8mm thickness on floors, skirting, treads and risers of steps over cement mortar bed 15mm thick in prop1:3 (1 cement : 3 coarse sand) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/Sika/Pedelite/Rouf/White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the department). Normal range Somany/Orient/Nitco/Asian Make
CEMENT PAINT & PRIMER: 13.2.3(a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.2.2 (n) Distempering two coats with oil bound disemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing surface even and sand prepared smooth. (a) Priming coat with distemper primer
13.2.2 (n) Distempering two coats with oil bound disemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with distemper primer of approved brand and manufacture after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing surface even and sand prepared smooth. (ii) Top coat.
13.6.4 Applying priming coat over new wood based surfaces up to 100mm in width/girth after and including preparing the surfaces by throughly cleaning oil, greases, dirt and other foreign matter, sand papering and knotting. (b) With ready mixed paint, wood primer(white).
13.6.5 Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/Nerolac) to give an even shade including clearing the surfaces of all dirt, dust and other foreign matter, sand papering and stopping. (b) High gloss (Asian paint/Berger paint/ICI paint/J&N paint/Nerolac)
13.7.2 Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly clearing oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed "red-lead/red oxide" primer.
Applying primary coat over new steel and other surface over 100mm in width or girth after preparing the surface by throughly clearing, oil, grease, dirt and other foreign matter and secured with wire brushes, fine steels, wood scrapers and sand paper.
Plain cement concrete works with coarse aggregate of size 13mm to 32mm in foundation bed for footing steps, walls , brick work etc. as directed and specified including dewatering if necessary, and curing complete (Shuttering where necessary shall be measured and paid separately) (b) In prop 1 cement: 3 sand : 6 coarse aggregate by volume.
Providing and laying controlled cement concrete of grade Sq.M0 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete works (form work and reinforcement will be measured and paid separately) (a) In substructure upto plinth level Foundation, tir beam, base of column and the like and other works not less than 100mm thick up to plinth level.
SHUTTERING: Providing form works of 12mm thick plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in. (i) Columns, pillars, posts & strut of square rectangular/Polygonal in plain or any shape like Tee/L etc. having plane vertical face.
Providing form works of 12mm thick plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in. (ii) Sides and soffits of beams, beam haunchings cantilever girders, bressumers, lintels and horizontal ties (a) For depth not exceeding 1.0M
Providing form works of 12mm thick plywood Board so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in. (iii) Flat surface such as soffits of suspended floors, roofs, landing, chajja and the like. (a) Floors etc up to 200mm in thickness.
Brick work Providing soling in foundation and under floors at all levels with best quality pickedjhama bricks, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete. (a) Brick flat soling
Brick work in cement mortar with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in substructure up to plinth level. (b) In prop 1:4
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarsesand) joined with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Providing ceramic tiles of approved quality, size, shape and thickness not less than 6mm thickness on floors, wall, skirting, riser and treads of steps over cement mortar bed in prop 1:3 (1 cement : 3 coarse sand) including cutting where necessary, complete at all levels as specified and directed. (b) At walls Normal range. 200 X 200
Plastering , Painting 15mm thick cement plaster in single coat for plastering up to 1st floor level including arises, and /or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. (a) In cement mortar 1:4
Providing one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surface free from mortar droppings and other foreign matter and including preparing surface even and sand papered smooth.
Reinforcement and steel works: Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. codes for R.C.C. work/R.B walling including straightening, cleaning, cutting and bending to proper shape and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (Up to 1st floor level) (i) TATA/SAIL
Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. codes for R.C.C. work/R.B walling including straightening, cleaning, cutting and bending to proper shape and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete (Up to 1st floor level) (b) ISI approved - M.S. Rod
WATER SUPPLY AND FITTINGS: Supplying, fitting and fixing PVC pipes of 6 kgf/csq.M (Supreme/Prince) or other ISI approved including joining, fitting and fixing clamp etc. as necessary complete at alll level including below GL as directedand specified. (a) In exposed surfaces or in trenches. (I) 110mm dia.
Supplying, fitting and fixing P.V.C bend I.S.I approved (87.5 degree) including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (a) 110mm dia
Supplying, fitting and fixing P.V.C plain tee I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) IN exposed surfaces or in trenches. (a) 110mm dia
Supplying, fitting and fixing P.V.C single Y I.S.I approved including necessary adhesive etc. in joints at all levels as necessary complete including below G.L. as directed. (i) In exposed surfaces or in trenches. (a) 110 mm dia
(a) Providing, fitting and fixing 75mm dia PVC cowel with ISI make complete as directed and specified.
Supplying, fitting and fixing GI Pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple Plug, long screw fitting HW clamp etc.complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (a) 40mm dia
Supplying, fitting and fixing GI Pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple Plug, long screw fitting HW clamp etc.complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (b) 32mm dia
Supplying, fitting and fixing GI Pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple Plug, long screw fitting HW clamp etc.complete at all levels including below GL as directed and specified. (A) Exposed or in trenches using TATA (medium) (c ) 25mm dia
Supplying, fitting and fixing GI Pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple Plug, long screw fitting HW clamp etc.complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C. and making good to the damaged structure TATA (medium) (a) 32mm dia
Supplying, fitting and fixing GI Pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple Plug, long screw fitting HW clamp etc.complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C. and making good to the damaged structure TATA (medium) (b) 25mm dia
Supplying, fitting and fixing GI Pipes of following sizes, with all necessary approved fittings such asbend, tee, elbow, reducer, nipple Plug, long screw fitting HW clamp etc.complete at all levels including below GL as directed and specified. (B) Concealed by chiseling or breaking brick wall/C.C./R.C.C. and making good to the damaged structure TATA (medium) (c ) 15mm dia
Supplying, fitting and fixing C.P. bibcock 15mm dia of approved as directed and specified. (G.I. & C.P. pipes will be measured separately). (i) Bib cock short body, Essco make
Supplying, fitting and fixing heavy brass stop cock of SANT make or similar approved of size as mentioned below and as directed and specified. (G.I. pipes will be measured separately). (d) 40mm dia ISI marked.
Fully automatic Micro-organism based natural composting system with PLC based control, insulated oil heating chamber, stainless Steel (SS304) shaft & mixing blade to convert organic waste like kitchen waste, canteen waste etc. to organic manure. (a) Capacity 24kg.
Sanjay Kr. Sarkar
SANJAY KR. SARKAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .