| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹21.7 L+₹85,865.39 (4.12%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹21.8 L+₹92,885.47 (4.46%)Rejected-Finance SR NO 331 2B PLOT NO 43 R H NO 02 BALDEWA RAO BUNGLOW NEWA NMC WATER TANK PATHARDI SHIVAR NASHIK 422 009 INDEX NO E 84CWE AF LOHEGAON PUNE | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹21.9 L+₹1.1 L (5.06%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹23.0 L+₹2.1 L (10.1%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Jul 2023, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR/ REPLACEMENT OF STREET LIGHTS AND MAINT OF EARTHING PITS, LIGHTENING ARRESTOR, FIRE ALARMS AND CONTROL PANELS ALONGWITH OTHER MISC ITEMS AT AF STN DEOLALI
2023_MES_602207_1
8110/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
DEOLALI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹60,000
Yes
2 Aug 2023
9 Jun 2023
6 Jul 2023
10 Jun 2023
4 Jul 2023
22 Jun 2023
Amount
Disconnecting/ Isolating electric supply from the source at electric pole / on walls/ tower and taking down carefully for repairs the existing unserviceable street/ security light/ flood light fittings of any make/ type/ wattage at and repairs at shop by checking and making the fittings serviceable at any time round the clock by replacing the damaged/ unserveciable parts with new parts as required and supplied, under relevant items at the supply only rates subsequently followed as mentioned here in under, by the contractor for replacement to suit the existing parts and fittings ( fixing charges for replacement shall be deemed included in the quoted rates against serial item No. 1) complete refixing at existing locations or as directed by Engg. in charge, connecting with source and testing for proper functioning of the fittings complete as directed.
Supply only LED outdoor drivers up to 48W of suitable for LED fittngs as per existing.
Supply only LED outdoor drivers up to 60 W of suitable for LED fittngs as per existing.
Supply only LED outdoor drivers up to 72 W of suitable for LED fittngs as per existing.
Labour only for repairs to existing unserviceable gatelight fittings, such as post top lanterns integral spherical shaped fittings, diamond shaped mercury fittings etc in position at site by checking and making the fittings serviceabe any time round the clock by replacing the damaged / unserviceable parts with new parts as required and as directed and testing for proper functioning of fittings coplete as directed. Note: The follwing parts as per SI No 6 to10 where found unserviceable shall be arranged and supplied by the contractor for replacement to suit existing parts and fittings and the contractor shall be paid for the following
Supply only LED lamp 10 watt normal holder type (Regular Retro fit )
Supply only LED lamp 5 watt normal holder type
Supply only LED lamp 7 watt normal holder type
Supply only LED lamp 15 watts normal holder type
S&F in repairs street light brackets with 40 mm dia GI tubing light grade, 1.5 metre length, bend to shape required including fixing with suitable MS clamps made out of MS flat 40x3 mm, nuts, blots, washers etc. and fitted on HT/LT poles/walls all as directed.
S&F in repairs street light brackets with 25 mm dia GI tubing light grade, 1.5 metre length, bend to shape required including fixing with suitable MS clamps made out of MS flat 40x3 mm, nuts, blots, washers etc. and fitted on HT/LT poles/walls all as directed.
M & L Cutting of branches of trees having girth exceeding 5 cm but not exceeding 20 cm including disposal of unserviceable material to a distance 100 mtr for removing/ cleaning over head ACSR conductor around 3 mtrs all as directed by the Engineer in charge. Note (a) Each Span avergae length 25 to 35 mtrs (b) T & P rrequired for cutting branches shall be provided by contractor without any extra cost.
S&F in repairs LED street light fittings 60 watt with pressure die cast housing, toughened glass and invidual LEDs witj secondary lens optics with IP 66 Ingress protection surge protection 4 KV inbuilt and 10 KX extrnal surge, top opening dirver fixed on existing/new GI pipe braket fixed on HT/LT poles and connection suitable size all as directed. make: Bajaj cat Part ZELA P 86 L WH PO TG SD or equivalent in crompton/ Havells.
S&F in repairs LED street light fittings 72 watt with pressure die cast housing, toughened glass and invidual LEDs witj secondary lens optics with IP 66 Ingress protection surge protection 4 KV inbuilt and 10 KX extrnal surge, top opening dirver fixed on existing/new GI pipe braket fixed on HT/LT poles and connection suitable size all as directed. make: Bajaj cat Part ZELA P 86 L WH PO TG SD or equivalent in crompton/ Havells.
S&F in repairs LED street light fittings 90 watt with pressure die cast housing, toughened glass and invidual LEDs witj secondary lens optics with IP 66 Ingress protection surge protection 4 KV inbuilt and 10 KX extrnal surge, top opening dirver fixed on existing/new GI pipe braket fixed on HT/LT poles and connection suitable size all as directed. make: Bajaj cat Part ZELA P 108 L WH PO TG SD or equivalent in crompton/ Havells.
S&F in repairs LED street light fittings 110 watt with pressure die cast housing, toughened glass and invidual LEDs witj secondary lens optics with IP 66 Ingress protection surge protection 4 KV inbuilt and 10 KX extrnal surge, top opening dirver fixed on existing/new GI pipe braket fixed on HT/LT poles and connection suitable size all as directed. make: Bajaj cat Part ZELA P 108 L WH PO TG SD or equivalent in crompton/ Havells.
S & F PVC Insulated and weather proof three core multistrand conductor cable 1.5 sqmm, size as required length for replacing US cable for styreet light where ever founf US from junction bos to street light all as directed by Engr-In-Charge. Make Havells, polycab, Gloster and plaza
S&F in repairs post top lantern decorative HERITAGE LED light fittings 1x20 watt retro LED with opel deffuser including LED 15W including its pedestal duly fixed in the PCC, IP 65 protection fixed on existing/new GI pipe braket and connection with PVC aluminium 1.5 sqmm 3 core cable etc complete all as directed. make: Crompton cat part LPTH-20-CDL eqvlt to Bajaj, Havells, wipro as approved by GE complete all as directed by Engg. in charge.
S&F in repairs flood light fittings 150 watt LED with min 110 lm/watt system luman output. The Lumanaire shall have cool white colour temp with 5700 K, pressure die cast aliminium epoxy powder coated with weather proof gasket for LED and control gear compartment with IP 66 Protection, 10 KV external SPD with high power LED and acessories fixed on existing/new GI pipe braket fixed on HT/LT poles and connection with PVC aluminium 1.5 sqmm 3 core cable etc complete all as directed. make:Bajaj Cat part PRAZE F 180 L WH NB A5 TG SD equivalent incrompton/ Havells,
S&F in repairs flood light fittings 120 watt LED with min 110 lm/watt system luman output. The Lumanaire shall have cool white colour temp with 5700 K, pressure die cast aliminium epoxy powder coated with weather proof gasket for LED and control gear compartment with IP 66 Protection, 10 KV external SPD with high power LED and acessories fixed on existing/new GI pipe braket fixed on HT/LT poles and connection with PVC aluminium 1.5 sqmm 3 core cable etc complete all as directed. make:Bajaj Cat part PRAZE F 144L WH NB A5 TG SD equivalent incrompton/ Havells,
S&F in repairs flood light fittings 100 watt LED with min 110 lm/watt system luman output. The Lumanaire shall have cool white colour temp with 5700 K, pressure die cast aliminium epoxy powder coated with weather proof gasket for LED and control gear compartment with IP 66 Protection, 10 KV external SPD with high power LED and acessories fixed on existing/new GI pipe braket fixed on HT/LT poles and connection with PVC aluminium 1.5 sqmm 3 core cable etc complete all as directed. make:Bajaj Cat part PRAZE F 120 L WH NB A5 TG SD equivalent incrompton/ Havells,
S & F in repair PVC perplex cover globe type with base plate/holder not less than 8 inches dia suitable for post top latern including one Nos 7/9 watt LED lamp complete all as specified and directed by Engr-In-Charge make Bajaj/Sutya/havells
Taking down unserviceable main switch supply install, testing commissioning sheet metal box of size 60x45x20 cm made out of 1.6mm thick CRCA sheet powder coated for fixing street light timer switch, frame pole mounted type with following accessories and connecting cable with proper lugs, glands etc.(a) Digital Timer switch AlphaRex D22, 2 channels Legrand cat No. 412641(b) 25 Amps, 4 pole/230 volt power contactor Cat No 4125 51or equivalent in Secure, Rishabh, L&T as approved by GE) all as specified and directed.
M&L for jointing & testing heat shrinkable cable joint kit , straight through , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor up to 50sqmm 3-1/2 core cable including necessary jointing work all as specified & directed
M&L for jointing & testing heat shrinkable cable joint kit , end termination , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor up to 50 sqmm 3-1/2 core cable including necessary jointing work all as specified & directed
Restringing of existing LT overhead line of copper/ACSR conductor after opening of binding wire from insulator and bringing the sag within limit rebinding the same with insulator with 16 SWG aluminium wire/suitable copper wire all including renewal of jumpers by providing heavy duty alkathine pipe of approved quality, reconnecting the service connections after cleaning the carbon and foreign material complete all as directed.
Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in soft soil.
Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in hard soil.
Returning Filling in including spreading, leveling, watering & well ramming in layers n. exc 25 Cm.
Removing excavated/Surplus soil n exc 50 Mtr & depositing where directed at a level n. exc 1.5 Mtr above the starting point.
M&L for double wall corrugated (DWC) duct (dure guard) as per IS 14930 part II LT UG cable protection including coupler, elbows, T joiints, Bends etc. and test report Make: Dura line/ Gemini/ Rex of size 38mm inner dia and 50mm outer dia al as per direted by Engr in charge.
Supply and laying in repairs LT XLPE insulated/PVC heavy duty armoured cablle 1100 volts grade UG stranded aluminium conductor electric cable cross sectional area 25 Sqmm 4/3.5 Core including necessary connection with provision of lugs & cable gland fixing arrangements all as specified and directed.
Supply and laying in repairs LT XLPE insulated heavy duty armoured cablle 1100 volts grade, multi-stranded aluminium conductor electric cable, cross sectional area 16 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
Supply and laying in repairs LT XLPE insulated heavy duty armoured cablle 1100 volts grade, multi-stranded aluminium conductor electric cable, cross sectional area 35 Sqmm 3.5 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
Supply and laying in repairs LT XLPE insulated heavy duty armoured cablle 1100 volts grade, multi-stranded aluminium conductor electric cable, cross sectional area 10 Sqmm 2.0 Core including necessary connection with lugs, cable gland & fixing arrangements all as specified and directed.
S & F in repairs single piece moulded PVC box of size 230X185X110mm outer dimensions (Sintex or equivalent of National ) consisting of one porcelain kit kat 6 Amps with suitable fuse wire as per current requirement & one 4 way connector including all necessary fixing arrangements to fix to pole i.e. clamps, nuts, bolts & washers of suitable size after dismantling the existing pole coping and replacement of cable lugs and cable gland all as directed.
M&L for Cable route indicator fabricated from 40x40x6mm angle iron 450mm long, rivited or welded with 100mm dia CI or MS round disc duly engraved " LT cable" in letters including grouted in ground with PCC 1:4:8 type D-2 compete all as specified and directed by Eng in Charge
M & L for cement concrete (1:3:6 ) type C-1 using 20 mm graded stone aggregate, including weathering, slightly rounded Chamfered angles and throating including necessary form work all as directed .
M&L for checking of serviceability of existing street/security/gatelight fittings in whole 25 ED area for 03 times for a week including submitting serviceability report to office in proper fomat using necessary man power, T&P and transportation facility all as directed by Engr in charge
M&L for refixing of dislocated/ uprooted GI/Copper Strip along with insulator from wall/ celing/ roof or any other location as directed from any building/ panel/ hanger/ any type of structure any size and shape. Refixing should be done in proper order and alignement on existing insulator or replaced with new one if broken/ unserviceable complete all as directed by Engineer-in-Charge. NOTE: i) The quoted rate is deemed to be include the rate of necessary nuts & bolts used to refix the strip on insulator or the clamps along with nuts & bolts required to fix the GI pipe in vertical postion on wall / ceiling/ floor etc complete. ii) Porcelain/polycarbonate Insulator will be measured and paid seperatly under relevant items of this schedule.
M&L for construction of PCC block by using PCC1:3:6 C1 (20mm graded aggregate) for erthing pit, errection of GI tube light grade as in foundation in any size as per roof top condition as directed at site, on roof of any type of building/ structure including dismantaling of existing outlived old block complete all as directed by Engineer-in-Charge.
Supply and fixing in repair insulator porcelain/polycarbonate/wooden block with suitable fixing arrangement by means of nuts & bolts for roof earth continiuty conductor and down conductor duly insulated from wall surface/roof of any type bldg/ hanger/ structure all as directed by Engineer- in- Charge.
Material and labour for earthing complete with galvanized steel earth plate electrode of size 60cm x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below ground level connected to galvanized iron strip 32 x 6 mm by means of of galvanized iron nuts & bolts or as directed at site by Engineer -in-Charge protected by GI Pipe 40 mm dia light grade and connected to test point and further connected to equipment, mcachinery, electrical panel or any other as directed by Engineer-in-Charge, which to be earthed, all as shown in electrical plate No 3 of SSR Part I including providion of concrete earth pit constructed in PCC 1:3:6 type C-1 as earth pit and PCC 1:2:4 type B-1 for cover slab with necessary reinforcement with handle for lifting also including provision of funnel with wiremesh with 20 mm GI pipe medium grade for watering, charcoal and salt in alternative layers of 15 cm thick all around the electrode , including necessary excavation and earth work , testing and commissioning complete all as directed at site.
All as per Ser Item No 43 above but complete but by using galvanized iron strip 25 x 4 mm as earth continuity conductor complete all as directed by Engineer-in-Charge.
All as per Ser Item No 43 above but complete but by using with copper earth plate electrode of size 60cm x 60 cm x 3.15 mm thick and copper strip 20 x 3 mm as earth continuity conductor complete all as directed by Engineer-in-Charge.
All as per Ser Item No 43 above but complete but by using galvanized iron earth lead wire 4.0 mm dia as earth continuity conductor complete all as directed by Engineer-in-Charge.
Note:- (i) The quoted rate shall deemed to be included the rate of boring in any type of soil, provision of PVC earth pit cover, mineral filled compound (earth back filled material) 50 kg, removal of excavated material from site, test link for test point, necessary sadling and mounting of GI strip on walls etc (ii) Copper strip complete will be measured and paid seperatly (iii) Workmanship shall be carried out in accordance with guide lines of OEM (installation and commissioning) and the certificate from concerned OEM to this effect shall be obtained and submitted to department. (iv). Back-fill compund shall not be mixed with any soil while pouring in the bore hole. c). The earthing material supplied shall be checked / inspected by Jef's/respective Make Engineer d). Atleast One Jef Eco/respective Make Safe earthing installtion shall be carried out under supervision. e) Earthing value for an individual earth pit should be less than 2 ohms and in grid connected it should be less than 1 ohm irrespective of type of soil/strata/rock/other if any etc.., complete all as specified and as directed by the Engineer-in-charge. including provision of earth pit cover, test link for test point, necessary saddling and mounting of strip complete all as directed. Make: JEF ECO SAFE, SPA infrastructure's safe earthing electrode, Pune or JMV LPS Ltd, Delhi or equivalent as approved.
M & L for earth enhansing material/Backfill compound of A+ grade available in 25 Kg packaging bag (mineral filled compound) for lowering the resistivity of soil of existing earth pit against higher resistance.The backfill compound should strictly be a Activated carbon based conductive type which has the resistivity less than 0.12Ω mtr as per clause 14.5D of IEEE:80-2000 Standard. Tested as per IEC :62561-7 and the test certificate to be submitted .Shall not depend on the continous presence of water/moisture/salt to maintain its conductivty. Shall not decompose or leach out with time. Shall contain a corrosion inhibitor to prevent corrosion of copper. Should not contain hazrdous chemicals and necessary test certificate from reputed accredited laboratories shall be submitted.Should not get affected by drought and shall be stable between -10ᴼc to +50ᴼc temperatures. Shall be suitable for any kind of soil. Shall be supplied in sealed, moisture proof bags. These shall be marked with manufacturers name or trade nam, quantity, batch no & date of manufacture. Back-fill compound should be electronically conductive ( Like in metals) & should not depend on moisture for conduction. Back-fill compund should be environment friendly, should solidify when mixed with water and set like concrete and should not leach/diffuse into the ground, disconnecting or reconnecting strip with nuts & bolts complete all as directed by engineer in charge.Note Earth work & excavation rate shall be deemed to be included in quoted rate, copper plate will be cleaned by chemical/grinding machine, upto satisfactory level of Engineer-in-charge.Make:JEF ECOSAFE/JMV/KAPILNASH/JEF TECHNO SOLUTIONS
Supply and fix Aluminium strip of size 25 X 3 mm as earth continuity conductor for roof and down conductors fixed/run on wall/celing/roof of any type of bulilding/hanger /structure with proper clamping or saddling duly supported on porecelene/polycarbonate/wooden block with suitable fixing arrangement of nuts & bolts or psses through wall by making hole or any other indicated situation complete all as directed according site condition by Enginer-in-Charge. NOTE: i) The quoted rate does not include the rate for porecelene/ polycarbonate/wooden insulator, the same may be measured and paid seperately under the relevant items of this schedule.
Supply and fix Copper strip of size 20 X 3 mm as earth continuity conductor for roof and down conductors fixed/run on wall/celing/roof of any type of bulilding/hanger /structure with proper clamping or saddling duly supported on porecelene/polycarbonate/wooden block with suitable fixing arrangement of nuts & bolts or psses through wall by making hole or any other indicated situation complete all as directed according site condition by Enginer-in-Charge. NOTE: i) The quoted rate does not include the rate for porecelene/ polycarbonate/wooden insulator, the same may be measured and paid seperately under the relevant items of this schedule.
Supply and fix Galvanised Iron wire of size 4 mm dia as earth continuity conductor fixed/run on wall/celing/roof of any type of bulilding/structure with proper clamping or saddling duly supported on poreceling/polycarbonate/wooden block with suitable fixing arrangement of nuts & bolts or laid in ground/ floor/hard standing, psses through wall by making hole or fixed to poles or any other indicated situation and drawn through GI Pipe 15 mm bore, light grade complete all as directed according site condition by Enginer-in-Charge.
Supply and fix, laid in ground/floor/hard standing or fixed on wall Galvanised iron strip 32 x 6 mm as earth continuity conductor, including provision of necessary sadling/ mounting, nuts, bolts and washers complete all as directed. Note for item No 9 to 12:- The quoted rate shall deemed to be included the rate of necessary excavation in any type of soil or in hard standing and also included the rate of necessary sadles, clamps to run the conductor on wall / ceiling / in existing trench, making connections to the existing LT panels, DB etc with help of necessary nuts, bolts and washers complete.
Supply and laying in trenches/ floor/hard standing, fixing on wall / roofs/ celing of any builgding/ structure GI Pipe 40 mm bore light grade including all necessary fittings for the protection of GI earth Strip complete all as directed by Engineer-in-Charge.
Supply and laying in trenches/ floor/hard standing, fixing on wall / roofs/ celing of any building/ structure GI Pipe 25 mm bore light grade including all necessary fittings for the protection of GI earth Strip and mounting of air termination rod complete all as directed by Engineer-in-Charge.
Repair/replacement of existing damaged earth chamber of PCC of any size including removal of old chamber and disposing at outside the MOD land, complete all as specified and as directed by the Engineer-in-charge.
M&L for carrying out physical inspection and measurement of individual earth pit resistance of each earth pit, every month located in area and maintain the record of its reading month wise and submitt this office timely. For measuring the resistance of individual electrode of LV distribution system and other non-DG/ Transformer by fall of poterntial test in case fall of potential method is not possible at certain locations then measurememnt of earth pit reisistance shall be carried out in stake less method using current and voltage clamps. Total 525 Nos earth pit approx located in different area of this station shall be measured in each month or all as directed. pit for measurement of pit resistance inclusing necessary excavation in any type of soil, or braking of hardstanding for inserting of spikes complete all as directed by Engineer-in-Charge. iii) The rate also include to inspect and measure resistand of any type of earth( like conventional or chemical, strip or wire any size) complete.
M&L for fixing air temination single pointed aluminium rod 12 mm dia and 300 mm long as directed by engr -in - charge.
M & L For repairing of fire alaram syastem of any type any model or make including opening th control panel of alaram system and replacement of any unservicable spres and making the control panel srvicable condition all as per directed by Engr - in- Charge .
M& L for replacement of fire / smoke detector of any type or model all as specified and directed by Engr - in - Charge
M& L for replacement of fire alaram of any type or model all as specified and directed by Engr - in - Charge
LOKMANYA ENTERPRISES
Shree Sai Samarth Enterprises
shubham Enterprises
SHRI SULAI ELECTRICALS
sapana enterprises
M/s.NIKI ENTERPRISES
Vinod Enterprises
M/S SVOJAS ELECTROMECH ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .