Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC GP RAM COLONY AMRITSAR JALANDHAR 144103 | AMRITSAR | AMRITSAR | PUNJAB | 144103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.6 L+₹2.4 L (8.11%)Rejected-Finance AWADHI ROAD ADAJAN 1ST 102 DABKA NO 1 1 6 4 C 4TH FLOOR | GANDHINAGAR | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.6 L+₹2.5 L (8.32%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹34.4 L+₹4.2 L (14.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹35.0 L+₹4.9 L (16.1%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
12 Sept 2024, 6:00 pmClosed
Garrison Engineer Air Force
Military Engineer services air force Stn Adampur 144103
MISC REPAIR TO ROOF TREATMENT AND SUNKEN PORTION IN CERTAIN BLDGS AT AF STN ADAMPUR
2024_MES_665688_1
GE/AF/ADM-22/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE AF Adampur
Refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹70,000
Yes
26 Sept 2024
12 Jul 2024
13 Sept 2024
12 Jul 2024
12 Sept 2024
26 Jul 2024
13 Jul 2024 - 25 Jul 2024
Amount
Cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edge etc complete all as specified.
PCC type E-2 (1:5:10), using 40 mm graded stone aggregates as in foundation filling & mass concrete, sub base, complete all as specified.
Precast reinforced cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in manhole covers and the like duly placed on manholes with cement mortar (1:4) complete.
Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified.
Brick work in half brick thick wall using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Water Proofing Treatment to RCC roofs comprising of the following : -
Taking down existing water proofing treatment (any no. of layers) from RCC roofs including cleaning the surface including flashings and junction of parapet etc. with wire brushing & water to the entire satisfaction of EIC, complete all as specified.
PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, laid to slope as directed by Engineer in Charge over RCC roofs as padding, complete all as specified.
Rendering 15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fair in cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified.
40 mm thick brick tiles are bedded over 15 mm thick cement mortar (1:4), and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified.
40 mm thick brick tiles (exept tiles) are bedded over 15 mm thick cement mortar (1:4), and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on APP membrane complete all as specified.
NOTE : For Guarantee of Water Proofing Treatment refer PS clause 11.5.
Water Proofing Treatment to RCC sunken surfaces comprising of :
Rendering 15 mm thick (Average thickness) rendering on sunken surfaes including flashings, finished even and fair in cement mortar (1:4), using water proofing compound as per recommended ratio, after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
LDPE sheet 150 micron laid over applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq. m & adjoining vertical surfaces including applying bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces complete all as specified.
NOTES FOR SERIAL ITEM NO. 7 & 8: For Guarantee of Water Proofing Treatment refer PS clause 11.5 of CA.
Supply only water proofing compound, ISI marked, complete all as specified.
uPVC pipes, 160 mm external dia pipe, type-A, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed to wall with PVC brackets as SWR / rain water pipes, IN REPAIRS, complete all as specified.
uPVC/PVC bends any radius, suitable for uPVC soil waste discharge pipes 160 mm external dia complete all as specified.
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished rough, as in sub floors or similar locations, complete all as specified.
Glazed ceramic coloured tiles 7mm thick, area of each tile exc. 0.17 Sq.m but n. exc. 0.19 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in grout of shade matching to tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified.
Non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exc. 0.06 Sq.m but n. exc. 0.11 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of shade matching to tile laid over and including 15 mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
Two coats of interior acrylic distemper/oil bound distemper on old ceiling surfaces, including preparation of surfaces, complete all as specified.
Complete removal of existing treatment of any description, including prepration of wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer.
Uprooting tree/plants upto 30 cm girth from wall or any part of building upto double storey buildings completly to the entire satisfaction of Engineer-in-Charge, making good the disturbed portion and filling holes in cement mortar (1:3) or PCC (1:2:4) type B-1 using 20mm graded stone aggregate to match with existing surfaces and removal of rubbish outside MOD land complete all as specified.
500 litre capacity, white, three layered polyethylene water storage tanks (cylindrical vertical with closed top) including hoisted and fixed in position, making connections, IN-REPAIRS, complete all as specified including the following acessories: - (i) Brass ball valves, high pressure, with GI rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, IN REPAIRS, complete all as specified. (iii) Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, IN REPAIRS, complete all as specified. (iv) Provn of 20 mm bore GI light grade tube from O/H tank to nearest mouth of RWP.
Disconnecting existing tanks of capacity exceeding 250 litre but not exceeding 500 litre, setting aside (or lowering if required) for cleaning/roof repair etc. and hoisting, reconnecting and re-fixing on existing location after necessary cleaning by removing all scale and dirt etc. including cleaning mouth of circulating service pipes also making all necessary connection complete, all as specified.
Disconnecting existing tanks of capacity exceeding 500 litre but not exceeding 1000 litre, setting aside (or lowering if required) for cleaning/roof repair etc. and hoisting, reconnecting and re-fixing on existing location after necessary cleaning by removing all scale and dirt etc. including cleaning mouth of circulating service pipes also making all necessary connection complete, all as specified.
Ball brass valves, high pressure, with rod & high density plastic ball complete screwed for iron pipe or brass ferrule and fixed, suitable for 20 mm bore GI pipe, IN REPAIRS, complete all as specified.
Steel tubes ‘medium grade’, galvanized with all fittings and fixed to walls and ceilings or laid in floors, including taking up or down steel tubing and connections from existing location, complete all as specified of size: -
15 mm bore
20 mm bore
Gun-metal stop valve (quarter turn type) with MS lever handle, suitable for GI tubes 20 mm bore, ISI marked, screwed both ends for iron pipe, IN REPAIRS, complete all as specified.
Angular stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: KEROVIT Cat No. KB1511003 or equivalent make mentioned in Appendix 'B'.
Concealed stop valve/cock, cast copper alloy, chromium plated, with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: KEROVIT Cat No. KB411032 or equivalent make mentioned in Appndix 'B'.
Bib tap, cast copper alloy, chromium plated fancy type, long body with wall flange, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: KEROVIT Cat No. KB1211033 or equivalent make mentioned in Appendix 'B'.
Wall mixer telephonic with crutch with provn for hand shower, cast copper alloy, chromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: KEROVIT Cat No. KB1311037 or equivalent make mentioned in Appendix 'B'.
Center hole basin mixer without pop up, cast copper alloy, chromium plated fancy type, quarter turn type, screwed end for iron pipe or for union and fixed, suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: KEROVIT Cat No. KB1211026 or equivalent make mentioned in Appendix 'B'.
Overhead ABS shower with cast copper alloy chromium plated arm 200 mm long with flange and fixed suitable for 15 mm bore pipe, IN REPAIRS, complete. MAKE: KEROVIT Cat No. KA550008 or equivalent make mentioned in Appendix 'B'.
Brass chromium plated towel rail 500 mm long, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS, complete. MAKE: PRAYAG Cat No. BA-10 or equivalent make mentioned in Appndix 'B'.
Health faucet CP brass body with wall hook and 1 metre SS tube, IN REPAIRS, complete. MAKE: PRAYAG Cat No. BEA-97 or equivalent make mentioned in Appndix 'B'.
Stainless steel peg set of six, fixed to wall with SS screws and PVC rawl plugs, IN REPAIRS, complete all as specified. MAKE: PRAYAG Cat No. BEA-30 or equivalent make mentioned in Appendix 'B'.
Vitreous China wash down water closet pan (pedestal pattern), white ISI marked, with & including stainless steel body Jet spray (L-bend) with 1.50 metre long braded tube tube, soft close ISI marked PVC seat & cover and uPVC 'S trap, IN REPAIRS, complete all as specified MAKE OF EWC: PRAYAG Cat No. 4016 or equivalent make mentioned in Appendix 'B'.
Vitreous China wash basin, white, flat back, size 550 x 400 mm, ISI marked, including fixing acessories like rag bolts etc. with CP waste coupling half or full threaded suitable for & including 32 mm size PVC solid waste pipe, IN REPAIRS, complete all as specified. MAKE: PRAYAG Cat No. 4645 or equivalent make mentioned in Appendix 'B'
PVC flushing cistern 10 litre capacity, dual flush syphonic action type, any shade, ISI marked (IS: 7231) with flush pipe and all fixing arrangements, IN REPAIRS, complete all as specified. MAKE: PRAYAG Cat No. 502 or equivalent make mentioned in Appndix 'B'.
Stainless steel round slotted grating with frame, 100 mm size fixed in position with cement joints, IN REPAIRS, complete all as specified.
PVC connections with PTMT nuts, 450 mm long, IN REPAIRS, complete all as specified.
uPVC pipes 75 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed under floors/walls as SWR pipes, IN REPAIRS, complete all as specified.
uPVC pipes 110 mm external dia, type-B, ISI marked (IS:13592) single socketed in any length with or without rubber ring joints, fixed under floors/walls as SWR pipes, IN REPAIRS, complete all as specified.
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 75 mm external dia, IN REPAIRS, complete all as specified.
uPVC/PVC bend any radius, suitable for uPVC soil waste discharge pipes 110 mm external dia, IN REPAIRS, complete all as specified.
uPVC floor trap, suitable for uPVC soil waste discharge pipes 75 mm ext dia, embedded in PCC type B-1(1:2:4), IN REPAIRS, complete all as specified,
Taking down cement plaster of any description on brick walls or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified.
Demolition brickwork built in cement mortar including all quoins, arches, pillars etc complete all as specified.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified.
Demolition of mud phuska in roofs, any thickness including plaster and leeping plaster all as specified.
Dismantlig brick tiles in roof laid dry and pointed in cement mortar all as specified.
Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
siddharthenterprises (BID ID -3084259)
M/s Sahib and Company (BID ID -3075496)
N S ENGINEERS (BID ID -3083346)
M/S GURBACHAN SINGH (BID ID -3086934)
PRATHAM TRADERS (BID ID -3085567)
MALHOTRA AND ASSOCIATES (BID ID -3084543)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .