| 1 | L1₹15.2 LAccepted-AOC WARD NO 16 HOUSE NO 66 SALLIAN TALAB UDHAMPUR 182 101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹24.5 L+₹8.8 L (56.4%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹24.9 L+₹9.2 L (58.9%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹25.1 L+₹9.5 L (60.4%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹25.9 L+₹10.2 L (65.3%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹23.9 L
EMD Value
₹47,800
Closing Date
30 Sept 2023, 6:00 pmClosed
HQ CWE (AF) Jammu
Headquarters, CWE (AF) Jammu Near Gurdwara Sahib and Mandir Airforce Station Satwari, Jammu Pin 180 003
REPAIR /REPLACEMENT/ MAINTAINCE OF HT UG/OVER HEAD ACSR CONDUCTOR /GODO/ VCB/ LBS/ ACB AND RE-RUTING/ RE-LAYING OF HT CABLE ALONG WITH DEHYDRATION OF TRANSFORMER OIL/ TOIP-UP REPLACEMENT OF TRANSFORMER OIL, RE-WINDING OF TRANSFORMER AND CERTAIN ALLI
2023_MES_609192_1
CWEAFJ-16/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Udhampur
As Per Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Udhampur
₹47,800
Yes
4 Dec 2023
2 Sept 2023
3 Oct 2023
2 Sept 2023
30 Sept 2023
23 Sept 2023
Amount
Transportation to UNSV servo voltage stabilizer of any capacity/size/make from various location of 901(SU) A/F station Nathatop and Dismantling the UNSV parts such as core winding with core,Servo Motor, R.C. circuit, dimmerstate, buck and booster transformers, carbon bush etc. and reassembly the same after repair/replacement to defective parts. (i)Transportation,deassembly/assembly/testing/commission/painting with writing of MES/SM No of appropriate size of letter etc and re-fixinging to it in original location shall be done in quoted rate.Nothing shall be extra payment to contractor. (ii)The new spair parts/copper winding etc. shall be measure and paid seprately.
Supply and filling voltage stabilizer oil low viscosity type conforming to IS 330 for topping up of stabilizer, all as specified and directed by Engr-in-Charge.
S&F in repair of micro switches, all as specified and directed by Engr-in-Charge. Make :- Kaycee/ESSAN/Volina/as per existing parts
S&F in repair of Auto manual switches, all as specified and directed by Engr-in-Charge. Make :- Kaycee/ESSAN/Volina/as per existing parts
S&F in repair of high and low voltage indicators, all as specified and directed by Engr-in-Charge. Make :- VAISHNO/HARRY/Volina/as per existing parts
S&F in repair of panel indicator lamp for main ‘ON’ indication, all as specified and directed by Engr-in-Charge. Make :- VAISHNO/HARRY/Volina/as per existing parts
S&F in repair of push button switch, all as specified and directed by Engr-in-Charge. Make :- Kaycee/ESSAN/Volina/Volina/as per existing parts
S&F in repair of Volt meter, all as specified and directed by Engr-in-Charge. Make:-ABB/ HPL/ L&T/ Havells/ Meco/ AE/Premier/Volina/as per existing parts
S&F in repair of Electronic sensing card (PCB), all as specified and directed by Engr-in-Charge. Make; AE/ VINTEC/ VOLINA/ BLUEHILL/ Volina/as per existing parts
S&F in repair of microprocessor based control card for each phase, all as specified and directed by Engr-in-Charge. Make :- AE/VINTEC/VOLINA/BLUEHILL/Volina/as per existing parts
S&F in repair of rotary switch for voltmeter RY-YB-BR-OFF-RN-YN-BN, all as specified and directed by Engr-in-Charge. Make :-KAYCEE/RICO/Volina/as per existing parts
S&F in repair of rotary switch for ammeter RY-YB-BR, all as specified and directed by Engr-in-Charge. Make :- KAYCEE/RICO/Volina/as per existing parts
S&F in repair of servo motor 3 Kg torque, all as specified and directed by Engr-in-Charge. Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F in repair of servo motor 10 Kg torque, all as specified and directed by Engr-in-Charge. Make :- AE/Volina/UNISTER/Volina/as per existing parts
M & L for rewinding of servo motor capacity 3 Kg/10 Kg Torque with insulating/varnishing, testing/commissioning etc with transportation/desmentling etc all as specified and directed by Engr-in-Charge.
S&F RC network for servo motor 3Kg/10 Kg, all as specified and directed by Engr-in-Charge. Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F in repair of carbon bush, all as specified and directed by Engr-in-Charge. Make :- AE/Volina/UNISTER/Volina/as per existing parts
S&F in repair dimmerstate unit of capacity 10 Amps for 10 KVA to 15 KVA, all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Green Dot/as per existing parts
S&F in repair of dimmerstate unit of capacity 15 Amps for 20 KVA, all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Green Dot/as per existing parts
S&F in repair of dimmerstate unit of capacity 28 Amps for 50 KVA, all as specified and directed by Engr-in-Charge.. Make :- AE/Volina/Green Dot/as per existing parts
S&F in repair of dimmerstate unit of capacity 60 Amps for 100 KVA, all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Green Dot/as per existing parts
S&F in repair of dimmerstate unit of capacity 80 Amps for 160 KVA, all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Green Dot/as per existing parts
S&F in repair of Buck and booster transformer(Main Transformer) 10 to 20 KVA all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Vintek Electronics./as per existing parts
S&F in repair of Buck and booster transformer(Main Transformer) 40 to 50 KVA all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Vintek Electronics./as per existing parts
S&F in repair of Buck and booster transformer(Main Transformer) 100 KVA all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Vintek Electronics./as per existing parts
S&F in repair of Buck and booster transformer(Main Transformer) 160 KVA all as specified and directed by Engr-in-Charge. Make :- AE/Volina/Vintek Electronics./as per existing parts
M&L for painting of the servo stabilizer complete by removing old paint by scraping and providing spary painting with approved synthetic enamelled paint of capacity 10 KVA to 160 KVA all as directed by Engineer-in-charge
10 KVA to 20 KVA
40 to 50 KVA
100 to 160 KVA
Taking down / disconnecting existing primary/secondary side repairable transformer of capacity 50 KVA to 400 KVA indoor /outdoor type removing from existing cable Will including earthstrip all as specified and directed by Engr-in-Charge. NOTE :-The contractor shall return the transformer duly repaired with in 20 days other wise a penalty of Rs 1000/- per day will be recovered from the firm.
M&L for Shifting including loading unloading and transporting of transformer 11 KV of size 50 to 400 KVA capacity with suitable arrangement after complete repair and satisfactory restoring from contractor’s workshop or work site including reconnecting with existing primary power cable and secondary power cable side & earthing of transformer after taking shut down and including testing & commissioning on existing load in the presence of officer nominated and Engr-in-Charge by contract complete all as specified and directed by Engineer-in-Charge. Note :-(i) Winding wire and other items/spares and new transformer oil mentioned in above will be measured and paid separately. (ii) Placing /removing standby transformer in the place of defective transformer under repair including loading /unlaoding, shifting including transportation and make the system/line function will be the responsibility of the contractor, contractor quoted rates shall be inclusive of all these factors. (iii) T&P for disconnecting the HT/LT connection of the transformer from pole/in side sub station/plinth and taking out the transformer from poles/plinth/inside the sub sation and shifting as directed place with the help of hydraulic/crane etc shall be deemed in the quoted rates.
Winding the transformer in repair 50 KVA to 400 KVA suitable for primary/secondary original size copper wire complete with all required insulation/ varmishing materials complete all as specified and directed by Engineer-in-Charge.
Reconditioning of LT Coil of aluminium/copper wound transformer by torning the old paper insulation straightening the entire LT strip ,providing new paper insulations of suprior quality and making coil of suitable design as original all as specified and directed by engr in charge.
Winding the transformer in repair 50 KVA to 630 KVA suitable for primary original size aluminium wire complete with all required insulation/ varnishing materials complete all as specified and directed by Engineer-in-Charge .
S&F in repair secondary stud bush of brass of brass complete with nuts bolts and washers of brass for 50 to 400 KVA Transformer complete all as specified and directed by Engineer-in-Charge including taking down old .
S&F in repair primary stud bush of brass of brass complete with nuts bolts and washers of brass for 50 to 400 KVA Transformer complete all as specified and directed by Engineer-in-Charge.
S&F in repair synthetic rubberized cord sheet 5 mm thick with suitable holes including replacement of defective nuts and washer of per existing size for 50 to 400 KVA Transformer complete all as specified and directed by Engineer-in-Charge.
S&F in repair cast iron wheel complete with solit pin etc for transformer 50 to 400 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repair Temperature gauge circular dia type of standard size and suitable for indoor/outdoor type transformers upto 400 KVA capacity all as specified and as directed by Engineer -in-Charge.
S&F in replacement breather assembly CI of standard size filled with silica-gel for transformer upto 630KVA complete allas specified and directed by Engr-in-Charge.
S&F in repair Dehydration/centrifuging of Transformer of capacity 11 KV to make the oil fit for reuse or oil as per standard procedure upto strength level 60 KV all including Oil topping up (new oil for toping/or for replacement shall be measured and paid separately) etc complete all as specified and directed by Engineer-in-Charge.
Supply and filling new transformer oil of ISI marked for transformer for topping up levels or for replacement of unfit oil having electric strength not less than 60 KV and shall be confirming to IS 335 complete all as specified and as directed. Make : power/ sweta/ equivalent as approved by GE.
S&F in repair suitable size of nut bolts/ washers complete all as specified and as directed including taking down old. Make : TVS or equivalent as approved by GE.
Taking down old unserviceable of transformer insulator brass rod ,Supply and fixinging of primary bush insulator brass rod of transformer complete all as specified and as directed by Engineer-in-Charge.
Taking down old unserviceable of Transformer insulator brass rod ,Supply and fixinging of secondary bush insulator brass rod of transformer complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement tap changer assembly complete for transformer rating upto 63 KVA to 160 KVA, including connecting up with HT coil and testing for varying voltage complete all as directed and specified by Engr-in-Charge.
All as per above srl item No.19 here-in-before but for transformer of capacity 200 KVA and upto 400 KVA.
Disconnecting the all electrical componant from transformer and opening the top cover after taking out the bush/stud and replacement the all gasket and oil seal of bushing and top cover and rectify the leakage of transformer oil in all respect as directed by Engr-in-charge of capacity 63 to 400 KVA transformer. Note :- All spare parts required during maintenance shall be measured and paid separately).
M & L for Silica gel (deep sky blue colour) for replacement in breathers of indoor/outdoor type transformer complete all as specified and directed by Engr-in-Charge.
M&L for painting of the transformer complete by removing old paint by scraping and providing spary painting with approved synthetic enamelled paint of following capacity:-
Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 2.25 mm thick as earth electrode burried directly in ground (earth pit not less than 3.75 Meter deep below ground level) with top edge of the earth plate not less than 2.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including brazing etc of earth electrode and earth wire by means of welding, all as directed including providing watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixinged to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
Note : (i) The grid of earthing trhough earth strip to achieved earth resistance less than 01 ohm to05 ohm shall be deemed into the quoted rate and no extra payment shall be made to contractor. (iii) The test point shall be made after the grid of earthing and algebric sum of of strip with GI protation pipe shall be measured after 7.5 mtr earth pit.The strip beyond the total sum shall be paid seperately (iii) Earthing will be carried out in presence of users and MES rep with entire satisfaction. (iv) The ground enhansing material (GEM) / chemicals shall be added with soil and the GEM/chemicals shall be measured and paid seperately.
M&L for supply and pouring of RoHS tested Earth Enhancement Compound after mixing with water tested by NABL accredited lab in compliance to IEC 62561-7 or its latest IEC code with a resistivity < 0.12 ohm-m. It shall be free from bentonite and other hazardous substances. It shall be a permanent, non-corrosive material and will not leach any chemicals into the ground. It shall retain moisture even in high soil resistivity areas. complete all as specified and as directed. Make: JMV or Equivalent as approved by GE.
Earth continuity conductor 20 x 3mm copper strip or main earthing lead fixinged to walls on batten or recess or chassis or buried in ground or drawn in conduit/pipe or fixinged to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engr-in-Charge
Earth continuity conductor or main earthing lead fixinged to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixinged to poles with the help of insulator or any other indicated situation for loop earthing etc and provision of brass/copper nuts, bolts washers etc wherever required and making joints as required 32 x 6 mm galvanised iron strip complete all as specified and directed by Enginer-in-Charge.
PCC Cable Route Indicators of size 600mm x 300mm x 50mm with letters inscribed on both sides as "MES HT CABLE" or "MES LT / HT CABLE" of specified font size not less 60mm as directed and mounted on PCC 450mm x 300mm x 300 mm complete using PCC 1:2:4 B-1(using 20mm crushed stone aggregate) and including painting with cement based paint complete all as specified and as directed by Engr-in-Charge.
M&L for dismantling damaged/ perished locking arrangement of GOD and making new locking arrangement with provision of 65 mm Godrej lock with 2 keys complete all as specified and as directed
Supply and fixing heat shrinkable 11 KV End termination kits and accessories of following capacities and type:-
Supply and fixing end joint kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm including taking down old. NOTE:- Item rate quoted including required T&P/Refixinging & Refilling in the panel/pole.
Supply and fixing end jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sq mm including taking down old. NOTE:- Item rate quoted including required T&P/Refixinging & Refilling in the panel/pole.
Supply and fixing heat shrinkable 11 KV End termination kits and accessories of following capacities and type:-
Supply and fixing cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm including taking down old. NOTE:- Item rate quoted including excavating/required T&P/Refixinging & Refilling.
Supply and fixing cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sq mm including taking down old, NOTE:- Item rate quoted including excavating/required T&P/Refixinging & Refilling.
Supply and fixing heat shrinkable End termination kits and accessories of following capacities and type:
Outdoor/indoor 70 to 150 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable, etc omplete as specified and directed
Outdoor/indoor 185 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable etc omplete as specified and directed
Outdoor/indoor 16 to 25 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable etc omplete as specified and directed
Outdoor/indoor 35 to 50 Sqmm 3.5/4 core cable jointing kit for 1.1 KV grade cable etc omplete as specified and directed
M&L for PCC 1:3:6 type C2 with using 40 mm graded aggregate as in foundation of broken transformer plinth with necessary form work complete as specified and directed by Engr-in-Charge.
M&L for type PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc for broken transformer plinth including necessary form work complete all as specified and directed by Engr-in-Charge.
M&L for bricks works with sub class B bricks straight or curved on plan exc 6m means radius built in cement mortar 1: 6 etc complete as specified and directed by Engr-in-Charge.
M & L for Brazing/Welding work with GI brazing/Welding alloy rod with the help of oxygen and LPG cylinder using required Copper of size 20 mm x 3 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper all as specified and directed by Engineer-in-Charge.
M & L for Brazing/Welding work with GI brazing/Welding alloy rod with the help of oxygen and LPG cylinder using required Galvanised Iron of size 32 mm x 6 mm upto 30 cm length along with cleaning work of strip with descaling solution/emery paper all as specified and directed by Engineer-in-Charge.
M & L for MS plate made of 1.6 mm thick of size 30 cm x 30 cm fixinged with suitable size ms flat iron with nut, bolt & washer and painted with red colour synthetic enamelled paint and write 8 cm height letter in white colour (feeder Name) as directed by Engr-in-charge
M&L for disconnecting burnt end or portion of 95 sqmm to 120 sqmm 3 core cable removing the cable from loop including necessary excavation, earthwork, removing brick protection and relaying the same, and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals of LT/HT cable to transformer/panel/pole etc complete all as specified.
Supply, fixing, testing and commissioning in repair air break gang operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT 15 Nos porcelain insulators of rating up to 200 Amps complete with drop out fuse assy having fuses of rating 40 Amps and steel channel frame, GI operating rod 25 mm dia of suitable length with operating mechanism worked form ground level, vertically operated including locking arrangement & operating handle, with and including padlock complete all as specified and as directed by Engr-in-Charge.
M&L for cross arms, bracings supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr-in-Charge.
Supply and fixinging of Lightning arresters expulsion type complete (Each Set -03 Nos ) with all fittings, transmission class, discharge capacity 65 kilo amp and hight current with stand 100 KA outdoor type for 11000 volts, including clamps, nuts and bolts, washers and connection to earth wire 4 mm GI strip to Lightning arrester complete all as specified and directed by Engineer-in-Charge.
M & L Danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixinged with M.S clamps , bolts and nuts of approved size, for HT, 25mmX20mmX 1.6mm size complete all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in soft/loose or any type of soil including boulder for taking up or laying of cable complete all as specified and directed by the Engr-in-Charge.
Returning filling in soils including spreding, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 meter and sepositing where directed at a level not exceeding 1.5 meter above the starting point, complete all as specified and directed.
Supply and laying new dry sand or Dry coarse sand as cushioning to cable 8 cm below the cable and 15 cm above the cable and punned to 18 cm as cable cushioning and coverning all as specified and as directed. Note:- Punned quntity will be measured and paid at this item.
Supply and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peack, size 300mm x 180mm x 40 mm inluding taking down old UNSV cable cover complete all as specified and directed by Engineer-in-Charge.
S&F Brick tiles, common burnt clay building /ducts bricks’ sub-class `B’ Designation 75 (230mmx115mmx75mm) complete all as specified and directed.
S&F GI tube light grade of size 50 mm with all fittings laid in trenches or fixinged to walls or fixinged in above the existing strip and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable complete all as specified and directed by E ngr in charge.
S&F GI tube light grade of size 80 mm with all fittings laid in trenches or fixinged to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable complete all as specified and directed by Engr in charge.
Supplying, laying, jointing, testing and commissioning HT under ground electric power cable Crossed linked polyethylene (XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade suitable for earth system of 3 core 95 Sq mm cross sectional area size, ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixinged on poles etc. complete all as specified and directed.
Taking down and Re-laying of HT cable of any size after rectify the fault or Laying of XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 11000 Volt grade, 3 Core 95 Sqmm to 3 Core 185 Sqmm including jointing and testing, laid in trenches / ducts / pipe or on poles complete all as specified and directed.
Taking down and Relaying of Lt cable of any size after rectify the fault or Laying of XLPE insulated, PVC bedded, galvanised steel strips armoured heavy duty electric power cable with stranded aluminium conductor suitable for rated voltage of 1100 Volt grade, 3.5 Core 50 Sqmm to 185 Sqmm including jointing and testing, laid in trenches / ducts / pipe or on poles complete all as specified and directed.
Notes for Serial Item No 53 , 54 & 55 1. For laying only, XLPE Cable will be issued 'Free for fixinging' under Schedule 'B' or existing underground cable shall be used as directed by Engr-in-Charge. 2. Quoted rates shall be inclusive of cutting of cable, provision of thimbles, lugs, stainless steel cable gland for connecting cable IN / OUT from Panels and Feeder Piller Boxes as per Site requirement. 3. The crimping shall be done only by Hand Operated / Hydraulically Operated Crimping Tool after applying conducting jelly and no other method will be allowed. 4. Extra use of cable shall be measured & paid separately in case of non availability of EM store.
Maintenance and complete overhauling of 11 KV VCB Make: Crompton/Kirloskar/Alsthom including disassembling of operating mechanism parts, well greasing of springs/repair of mechanical parts, spring charge assembly and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts, rewiring the control circuit/Lt circuit and components etc complete all as specified and directed by Engr-in-Charge.
Note - (i) The above job to be carried out by engineer of authorised dealer/service centre of concerned OEM. (ii) Replacing new items shall be measured and paid separately as supply only. The labour charges for fixinging shall be included in this item. (iii) Minor items such as nut,bolt/pins and control internal wiring are included in the quoted rate. (iv) If any defect occurred at any place of AFstn Nathatop , the contractor will provide machnic with in four hours for rectification of defects. If the contractor not provide the machanics and material with schedule time, the amount will be deduct 1000/hrs after receiving phone/massage/ watsup /email etc complete as specified and directed. (v) Other part which is not included but requierd for functioning of equipment is included in the quoated rate & The contractor shall arrange for the standby supply for testing of relays,
S&F in repair closing coil indoor type for 11 KV VCB in replacement as per existing make/model/capacity complete all as specified and directed by Engr-in-Charge.
S&F in repair triping coil indoor type for 11 KV VCB in replacement as per existing make/model/capacity complete all as specified and directed by Engr-in-Charge.
S&F in repair spring charging motor suitable for fixinging with 11 KV indoor type VCB panel as per existing make/model/capacity complete all as specified and directed by Engr-in-Charge.
S&F in repair insulator of VCB as per exising make/model/capacity/sape
S&F in repair digital volt meter/ammeter as per existing make/ model/capcity
S&F in repair indicator lamp as per existing make/model/capcity
S&F in repair cast regin wound CT of ration 400/200/5/5A as per existing ratio/make/model/capacity
S&F in repair cast regin wound PT as per existing make/model/ratio/capacity
S&F in repair isolating contact flat type as per existing make/model/capcity and size
S&F in repair tnc switch (Tripping neutral & closing) as per existing make/model/capacity
S&F in repair high voltage fuse as per existing make/model/capacity
S&F in repair VCB panel spout as per existing make/model/capacity
S&F in repair pin for ratchet as per existing make/model/size etc all as specified and directed.
S&F in repair relay assy as per existing model/make/capacity/size
Maintenance and servicing, tunning, caliberation and testing of RMU gas filled circuit breaker/Isolator/remote panel of make:- Schnieder-electric including checking of all electrical wiring, disassembling of operating mechanism parts, well cleaning, replacing unserviceable parts and accessories, oiling/greasing of moving parts including reassembling, fine setting of mechanism, and making SF6 Breaker in perfect operational in manual and electrical mode including well cleaning the complete panel board, main bus bar coupler, decarbonizing all joints, bus bars coupler, CTs, PTs, spouts metal parts and replacing unserviceable parts and components complete, all as specified and directed by Engr-in-Charge. Make of circuit breaker/Isolator :- Schneider
Note : (i) The above job to be carried out by engineer of authorised dealer/service centre of concerned OEM. (ii) Replacing new items shall be measured and paid separately as supply only.The labour charges deemed to be included in the unit rate quoted for this item. (iii) Contractor shall submit the connected doCument/graph for relay calibration duly authenticated by authorised dealer/service centre. (iv) If any defect occurred at any place of AF Stn Nathatop , the contractor will provide machnic with in one hours for rectification of defects. If the contractor not provide the machanie and material with schedule time, the amount will be deduct 1000/hrs after receiving phone/massage/ watsup /email etc complete as specified and directed. (v) Other part which is not included but requierd for functioning of equipment is included in the quoated rate & The contractor shall arrange for the standby supply for testing of relays. (vi) Spare parts will be measured and paid seperately as supply only under respective items.
S&F in repair RMU Protection relay DPX-V5 as per existing make/model/capcity
S&F in repair spout for breaker as per exising make/model/capacity/sape
S&F in repair digital multifunction meter as per existing make/ model/capcity
S&F in repair interlocking bush between A & K mechanism as per existing make/model/capacity
S&F in repair digital indicator lamp for breaker ON/OFF/Trip/Breaker spring charged/R-Y-B etc in 11 KV HT panel including associated wiring, if required complete all as per existing make/model/capcity all as specified and directed by Engr-in-Charge.
S&F in repair cast regin wound CT of ration 100-50/1 as per existing ratio/make/model/capacity
S&F in repair only cast regin wound PT as per existing make/model/ratio/capacity
S&F in repair battery of RMU (24 Volt) as per existing make/capacity
S&F in repair locking arrangement handle for RMU as per existing make/model
S&F in repair Voltage presence indicator as per existing make/model
S&F in repair battery 12 VDC, 12 AH of relay as per existing make/model
S&F in repair relay assy as per existing model/make/capacity/size
S&F in replacement pin type porcelain vitreous white, brown or green insulator including one galvanized spindle two GI washer and one GI nut 150 mm height, 150 mm dia for 11000 volts grade including taking down old UNSV pin type insulator complete all as specified and directed by Engineer-in-Charge.
S&F in replacement disc type porcelain vitreous white, brown or green insulator of 145 mm high and 255 mm dia ball and socket type,including one galvanized spindle two GI washer and one GI nut 150 mm height, 150 mm dia for 11000 volts grade including taking down old UNSV pin type insulator complete all as specified and directed by Engineer-in-Charge.
S&Fin repair of Stay assembly complete woth accessories as shown in electric plate no1 with dia of stay rod is 20 mm dia, 180 cm long including loop type insulator, stay clamps, excavation, concrete and stay wire, including taking down old unserviceable , complete all as specified and directed by Engr-in-charge..
M&L for Aluminium conductor, steel reinforced of size farret/mink/weasel, straining properly on insulators with and incluing aluminium tape/winding wire, clamps and jumpers etc. including taking down existing old unserviceable conductor and removing away complete all as specified and directed. Note :- Engr-in-Charge shall ensure that ACSR conductor shall be used as per the recommended size only.
Supply and fixinging Digital Grounding Device Mobile Transporatble Earthing Pit Advance Chemical Sealed Electrode Box Type light weight (Generation-5) Advance Chemical Sealed Electrode Box Type light weight GI horizontal electrode designed for use in any type of soil condition. Each electrode to be designed in box shape using GI,2mm thick plates of 600x450mmx100mm as outers of the box. two 50mm sockets are to be placed on top with removable caps and two handles to faciltate haniding. The inner space between platers is to filled with about 28 KG of Specillzed ASEM-GB an extremely low resistvity (0.05ohm/m & below) (High Conductivity) hygroscopic, non- soluble stable material. The material is filled in the electrode in very slury form made with water. After filling the high conductive salt in the box both the sockets are crapped and closed. A cu terminal 200x40x6mm is to be fixinged along the centre protruding on the socket centre the necessary connection/bonding. A 1.5 mtr length of PVC insulated 50 sq mm Copper Flexible cable is to be provided with each electrode for necessary connection to Distribution Bvox or bonding between two electrodes. One galvanized iron sheet junction/Distribution Box is to be provided with every two electrodes. The electrode Duplicacy/copy of the Equipment is subject to legal content
S&F in repair Protec ESE Terminal -PRO 60(Covering 107 mtr radious on level IV)
Tripod Earthing System -Maintanance free earthing system constining of Copper Bounded Rod 17.2 mm dia 10" Long qty 3 Jointing strip 25x3mm 3 mtr Long Qty 3 Low resistivity backfill compound PRO ASEM GB 25 Kg qty 3 bagsand 02 Nos of poly Plastic pit cover qty 03.
slathia construction works
ANIKET TRADERS
DAVINDER SINGH
PROACH ASSOCIATES BUILDERS & ENGINEERS
MOHAN LAL AND SONS
shivom builders
Bidder Name
slathia construction works
MOHAN LAL AND SONS
ANIKET TRADERS
LUXMI ELECTRONIC WORKS
DAVINDER SINGH
shivom builders
PROACH ASSOCIATES BUILDERS & ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .