Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-Finance 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹24.4 L+₹5.9 L (32.0%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹26.5 L+₹8.0 L (43.6%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹26.9 L+₹8.5 L (46.0%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance not being lowest |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
13 Mar 2023, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
REPAIR/ MAINTENANCE OF LIFT, DISHWASHER TOWER CLOCK, MISC EQUIPMENT AND WALK IN CHILLER, AC PLANTS AND OTHER ITEMS AT CME UNDER GE (CME) KIRKEE
2023_MES_578624_1
8396/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D, category b(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹52,000
Yes
16 Mar 2023
11 Feb 2023
16 Mar 2023
11 Feb 2023
13 Mar 2023
27 Feb 2023
12 Feb 2023 - 26 Feb 2023
Amount
Disconnection & removing of all electrical/mechanical connection carefully of tower clock for repair and replacement of defective boxes, spare parts, servicing/overhauling of clock machine and gear motion including cutting, filling, grinding, turning & balancing driving shaft and adjusting the differences in all clocks with respect to each other and setting of correct time, incl labour and technician charges all as specified and directed by Engr-in-charge.
Servicing/overhauling of gear box including replacement of unsv parts of gear box, brass wheel & connector, connecting wire 0.5 mm and motion work spindle coupling incl labour and technician charges etc
Supply and fixing in repairs SMPS 12V, 5 Amps all as specified and directed.
Supply and fixing in repairs Battery 12V-35 AH for tower clock all as specified and directed by Engineer-in-Charge
Supply and fixing battery charger for 12V-35 AH battery all as specified and directed by Engineer-in-Charge
Supply and fixing LED Strip 12 V suitable for tower clock
Supply and fixing Acrylic sheet 3mm thick
Supply and fixing Acrylic pipe 18 mm dia and 3mm thick
Hiring of lifter crane with cabin up to max height 25 to 30 metre high for fixing of outer dial of tower clock to all of four sides. Note : Necessary manpower like Electricial Technician, masonry work drilling to stone, fixing of dial, all labour charges for outside work are included in quoted rate for this item.
S&F surface and wall mounted LED batten (LED tube light fitting 20W) with polycarbonate housing & integrated electronic driver alongwith LED tube 20 watt and 02 No PVC square blocks incl taking down old UNSV fitting. Make:- Havells cat No LUMILINEBS20WLED830SPCWH or equivalent of Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker.
Disconnecting the electric supply and opening of the front panel of the dish washing machine strictly as per the manufacturers instructions/guidelines for carrying out inspection of heating and conveyor mechanism for washing of utensils. (skilled technicians from authorised dealer/company rep to be employed), replacement of defective heating kit RE 8230020 (BK) & fixing of front panel, conveyor system, PCB and contractors after carrying out necessary repairs as above, testing & commissioning to the entire satisfaction of Engr-in-Charge
Non comprehensive Maintenance and servicing of Lifts (Make : OMEGA) once in a month including attending faults on call basis for normal repairs including replacement of defective & worn out parts by new spares such as battery, landing ladder, contactors, relays, gearless drive, ARD, DBRs, PCB etc and greasing of bearings of Lifts as directed by engineer-in Charge. Note : i) Spares required for above maintenance will be measured and paid separately under relevant item. (ii) Servicing to be carried out as per manufacturer instruction (iii) Rate quoted shall deem to include for electrical inspection carrying out by electrical inspector lift of PWD
Lift of 08 Passangers (544 KG), Location : Viewers Gallery ARN CME Pune
Supply and fixing in repairs Door drive-Monarch Dore Drive
Supply and fixing in repairs 12 core wire-0.5 mm travelling cable for lift
Supply and fixing in repairs Rope 8 mm Usha Martin SS ropes
Supply and fixing in repairs flooring 5 mm thick PVC Sheet of size 1200mm x 1200mm. fixing using adhesive SR solution all as specified and directed.
Supply, fix and fabrication in repairs panel covering with ACP sheet 3mm thick on angle iron of size 45mm x 45 x 3mm thick for panel cover of existing panel at site (size of panel 1.8 m x 3.3 m)
S & F in repair Cop (Car operating panel) fixed in cabin all as specified and directed.
S & F in repair Lop (landing operating panel) installed in each landing all as specified and directed.
S & F in repair display cable 12 core 0.5 mm copper cable for display connection for elevator all as specified and directed. (make: Relicab)
S & F in repair Car and counter shoes make :Mass all as specified and directed.
S & F in repair main Card Mother Board (make : Omega) all as specified and directed.
Supply and fixing Battery 12V-180 AH for sub station backup complete all as specified and directed by Engineer-in-Charge
M&L for maintenance free grounding Solution set earthing comprising of Earthing rod, outer pipe in GI and having minimum diameter of 76mm, 3m in length and inner pipe to have minimum diameter of 32mm, both end properly welded to make them airtight. GI terminal size of 100x50x6mm with 2 Nos M8 holes for termination area in between two pipes filled with dry type chemical powder having high conductivity and make sure no air pockets are left. Electrode must be tested for short circuit test of minimum 40 KA at CPRI/NABL. The earthing electrode will be placed in the ground after a bore is drilled to the depth of 3.5 Mtr. The bore drilling will be done with the help of Pneumatic boring machine, 50 Kgs BFC will be placed in the bore to cover the earthing rod from all sides. BFC will be poured in Slurry form in properly mixed condition. The Earth pit cover Square 300x300x240 mm to be provided to cover the earth Pit and shall be made of reinforced FRP and should be capable of carrying the weight of 5 Tons. Make : U-PROTEC or equivalent in Ashlok earthings/JEF technology. NOTE :- (a) Rates of boring 3 Mtr for earth electrode, GI wire 4 mm & 40 mm dia protection pipe upto 7.5 Mtr from earth electrode is deemed to be included in the quoted rate. (b) On testing, after completion, if the earth resistance <3 ohms is not obtained, earthing will be rejuvenated at no extra cost till the desired earth resistance is obtained. (c) Test certificate from the OEM has to be produced by the contractorfor the material used in earthing
M & L in repair earth continuity conductor or main earthing lead fixed to wall or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or any other situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire all as specified and directed.
M&L for single run of 4 sqmm single core PVC insulated and unsheathed copper solid conductor 1100 volt FR cable complete all as specified and directed incl taking down old unserviceable one.
M & L for carry out routine maintenece and servicing of Package type air conditioner of capacity 8.5TR & 11TR including removing the dust from body with blower, cleaning the condenser and cooling coil, checking all the electrical and refrigeration piping connections, checking function of relay, capacitors, overload protector, thermostat, fan motor, blade, fan/blower drum, LT Control panel, VFDs, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-Charge. Note: 1. Spares parts replaced shall be measured & paid under saperate item
Supply only V-Belt Type 13x813A 32A840EL for Blower fan of Package AC Unit of Capacity 8.5TR/11TR
Supply only relay HP & LP for package type AC plant of capacity 8.5TR
Supply only relay HP & LP for package type AC plant of capacity 11TR
Supply only condensor fan motor , 230V,50Hz 920rpm 2 HP for package type AC, Model: 14B606A1E/2L-FP7 Make: Micro Instrument Co. or equivalent
Supply & fixing in replacement including connection 3 pole AC power contactor, 32 Amps, 415 Volt with auxilliary contact 1NO + 1NC, having coil voltage 380 to 400 Volts Make Simens cat ref C4NE22 or equivalent of L &T/Havells.
Supply, fixing and connecting in replacement integrated circuit board with all electronic components suitable for 8.5 TR capacity Carrier Pakage type Air conditioner.
Supply, fixing and connecting in replacement integrated circuit board with all electronic components suitable for 11 TR capacity Carrier Pakage type Air conditioner.
Supply, fixing and connecting in replacement SPPR Circuit board suitable for 8.5TR/11TR cap Package AC of Make Carrier.
Supply and fixing of 3Ph, 415V, 50Hz compressor of capacity 11TR suitable for package type AC
Supply and fixing of 3Ph, 415V, 50Hz compressor of capacity 4.25TR suitable for package type AC
Supply only thermostatic expansion valve for package type AC plant of capacity 8.5/11TR
All as per Item No. 28 above, but for carry out repair/maintenance of 3Phase, 415V, 50Hz Ductable type AC indoor and outdoor unit of capacity 8.5TR complete all as specified and direted.
Supply and fixing of condensate drain pump of ductable type AC of capacity 8.5TR
Supply and fixing of Condensor fan motor suitable for ductable type AC of capacity 8.5TR
Supply and fixing of fan blade suitable for outdoor unit of capacity 8.5TR ductable AC
Supply and fixing of Blower Motor suitable for Carrier Make Ductable type AC of capacity 8.5 TR
Supply and fixing of Direct driven forward curved type centrifugal Blower fan suitable for Carrier Make Ductable type AC of capacity 8.5 TR
Supply and fixing of Electronic PCB Kit for control panel suitable for Carrier Make Ductable type AC of capacity 8.5 TR
Supply and fixing of compressor 3Ph, 415V, 50Hz of capacity 8.5TR for carrier make ductable Air conditioner
Supply only thermostatic expansion valve for ductable type AC plant of capacity 8.5TR
All as per Item No. 28 above, but for carry out repair/maintenance of 3Phase, 415V, 50Hz Ceiling Mounted Cassette type AC indoor and outdoor unit of Capacity 4.0TR complete all as specified and direted by Engineer In Charge.
M & L for replacement of condensate drain pump assembly of cassette type AC of capacity 4.0TR
Supply and fixing of Sensor unit for water pump of carrier make cassette type AC indoor unit (as per existing).
Supply and fixing of Condensor fan motor suitable for cassette type AC of capacity 4.0TR
Supply and fixing of Fan blade made of HD PVC suitable for Carrier make cassette type AC of capacity 4.0TR outdoor unit incl lock nut.
Supply and fixing of Blower Motor/Indoor fan motor suitable for Carrier Make Cassette type AC of capacity 4.0 TR
Supply and fixing of Electronic PCB Kit for control panel suitable for Carrier Make Cassette type AC of capacity 4.0 TR
Supply and fixing of compressor 3Ph, 415V, 50Hz of capacity 4.0TR for carrier make Cassette type Air conditioner
Supply and fixing of three phase 3Ph, 415V, 50Hz overload protection relay suitable for ductable/cassette AC.
Supply and fixing of Air brake power contactor 3 phase AC 50 Hz 415V, 15Amps (as per existing) suitable for 4.0 TR Cassette type Air Conditioner.Make: Siemens/C&S/L&T/BCH
Supply and fixing of single phase preventor relay suitable for ductable/cassette AC.
Supply only thermostatic expansion valve for cassette type AC plant of capacity 4 TR
All as per Item No.27 above, but for carry out repair/maintenance of 3Phase, 415V, 50Hz Walk in Chiller and Cooler indoor and outdoor unit of Capacity 3.0 TR complete all as specified and directed by Engineer In Charge.
M & L for replacement of condensate drain pump assembly of capacity 3.0TR
Supply and fixing of Sensor unit for water pump of carrier make indoor unit (as per existing).
Supply and fixing of Condensor fan motor suitable for of capacity 3.0TR
Supply and fixing of Fan blade made of HD PVC suitable for Carrier make of capacity 3.0TR outdoor unit incl lock nut.
Supply and fixing of Blower Motor/Indoor fan motor suitable for Carrier Make of capacity 3.0 TR
Supply and fixing of Electronic PCB Kit for control panel suitable for Carrier Make of capacity 3.0 TR
Supply and fixing of compressor 3Ph, 415V, 50Hz of capacity 3.0TR for carrier make.
Supply and fixing of three phase 3Ph, 415V, 50Hz overload protection relay suitable for 3.0 TR walk in chiller
Supply and fixing of Air brake power contactor 3 phase AC 50 Hz 415V, 15Amps (as per existing) suitable for 3.0 TR walk in chiller. Make: Siemens/C&S/L&T/BCH
Supply and fixing of single phase preventor relay suitable for Walk in chiller.
Supply only thermostatic expansion valve for walk in chiller type AC plant of capacity 3 TR
M & L for detecting the gas leakage, rectifying the defects including repair to condenser coil/evaporator coil by means of welding soldering etc vacumizing, testing complete for the 11 TR pakage type AC .
All as per Item No.72 above, but for 4.25TR Compressor of 8.5TR Package type AC plant.
All as per Item No.72 above, but for 8.5TR Compressor of ductable type AC.
All as per Item No.72 above, but for 4.0TR Compressor of ceiling mounted ductable type AC.
All as per Item No.72 above, but for 3.0TR Compressor of Walk in chiller and cooler
Supply & charging of refrigerant gas R-22/404 for charging in Walk in chiller/Cassette AC/Ductable AC/Package AC complete and checking of leakage, testing for proper functioning all as specified & directed by Engineer-in-charge.
M&L for cleaning of Package type AC and surrounding area by surface excavation upto 10 cm depth incl removing shrubs, grass, miniplants and other unwanted materials and levelling complete in soft/loose soil all as specified and directed.
Supply and fixing Integral LED Street Light Luminaire 50 W, 6500K comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame suitable for 50/40 mm GI Pipe complete with accessories like GI pipe, wire, etc complete. Make : equivalent of Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker. all as specified here-in-after including taking down old fitting.
M&L for earthing with 600x600x6mm galvanised steel earth plate electrode burried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed.
S & F in replacement of Solenoid valve for Walk in chiller AC suitable for 3 TR
S & F in replacement of Solenoid coil of suitable size for Walk in chiller AC suitable for 3 TR
S & F in replacement of strainer for 4 to 11 TR Package type ACs/Ductable/Cassette AC
S & F in replacement of unserviceable/leakage Service Valve suitable for 4 to 11 TR capacity Package /Ductable/Cassette AC Plant.
S & F in replacement of unserviceable Solid state indicating lamps 230 Volt AC with RYB and green indication (LED type ) including adopter ring / washer and cable connection complete. Make: Altos
S&F in replacement of digital type temperature indicator including sensor and multicore copper cable ( Length of cable as per requirement )
Supplying & laying in replacement insulating mat of size 2000x1000x12mm thick with ISI mark of LT side
S&F in replacement single phase preventer of model VSP D-1A/SP-3, Make : Minilec
S&F in replacement copper tubing 3/4" for the package/Ductable/Cassette/Walk in chiller AC of capacity 3 TR to 11 TR as specified and directed by E-in-C.
metro electrical services
DURGAI ELECTRICALS
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .