SE CDC TANGEDCO
A10, THIRU VI KA INDUSTRIAL ESTATE, GUINDY CHENNAI 600032
Providing electrification of control room building at Alwarthirunagar II 33/11 KV Indoor SS
2021_EB_204156_1
OTNO8/21-22
Open Tender
Electrical Works
Works
45 days
A10 Thiru .vi.ka Industrial Estate, Guindy
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹7,782
Yes
5 May 2023
30 Jun 2021
14 Jul 2021
30 Jun 2021
13 Jul 2021
30 Jun 2021
30 Jun 2021 - 13 Jul 2021
180 days
Amount
Supplying and providing wiring for lights, exhaust fans etc., using with 2.5 sq.mm PVC insulated copper wire for phase and neutral and 1.5 sq.mm PVC insulated copper wire for looped earthing in 25mm rigid conduit .PVC casing not less than 25mm width and 2mm thickness of with necessary bends, Supplying and fixing of 5 / 15 Amps flush type switches fixed in a suitable GI anodised box with Hylem/ Sunmica sheet cover. The switch box of normal size 12"x8"x3" should be used. 1. 300mm (12") dia AC Exhaust fan = 2 Nos 2. 450mm (18") dia AC Exhaust fan = 4 Nos 3. 12W LED decorative ceiling Light = 4 Nos
Supplying and providing wiring for ceiling fans etc., using with 2.5 sq.mm PVC insulated copper wire for phase and neutral and 1.5 sq.mm PVC insulated copper wire for looped earthing in 25mm rigid conduit .PVC casing not less than 25mm width and 2mm thickness of with necessary bends, Supplying and fixing of 5 / 15 Amps flush type switches fixed in a suitable GI anodised box with Hylem/ Sunmica sheet cover. The switch box of normal size 12"x8"x3" should be used. 1.1200mm (48") AC ceiling fan = 12 Nos
Supplying and providing wiring for lights, etc., using with 2.5 sq.mm PVC insulated copper wire for phase and neutral and 1.5 sq.mm PVC insulated copper wire for looped earthing in 25mm rigid conduit .PVC casing not less than 25mm width and 2mm thickness of with necessary bends, Supplying and fixing of 5 / 15 Amps flush type switches fixed in a suitable GI anodised box with Hylem/ Sunmica sheet cover. The switch box of normal size 12"x8"x3" should be used. 1.18W wall mounted light (2 point controlled by 1 switch) = 14 Nos 2.Surface Mounted LED 43W (2x2) = 4 Nos (2 point controlled by 1 switch) 3. 100W Name Board light fitting = 1 No (2 point controlled by 1 switch) 4. 25W LED Gate Light post top lantern = 2 Nos. (2 point controlled by 1 switch) 5. 100W LED Outside light fitting = 4 Nos (2 point controlled by 1 switch) 6.10W Bulk Head light = 1 No (2 point controlled by 1 switch) 7.120W LED Tr.Yard Light = 4 Nos (2 point controlled by 1 switch)
Suppyling and providing wiring for Duct lights using with 2.5 sq.mm PVC Insulated copper wire for phase ans neutral and 1.5 sq.mm PVC Insulated copper wire for looped earthing in 25mm rigid conduit GI pipe not less than 25mm width and 2 mm thickness of with necessary bends Supplying and fixing of 5/15 amps flush type switches fixed in a suitable GI anodized box with hylem/sunmica sheet cover, the switch box of normal size 12"x8"x3" should be used. 1. Duct Light with GI conduit (5/1 control) Fitting 10W LED Light - 2 Nos.
Suppyling and providing wiring for additional heater point using with 2.5 sq.mm PVC Insulated copper wire for phase and neutral and 1.5 sq.mm PVC Insulated copper wire for looped earthing in 25mm rigid conduit GI pipe not less than 25mm width and 2 mm thickness of with necessary bends Supplying and fixing of 5/15 Amps flush type switches fixed in a suitable GI anodized box with hylem/sunmica sheet cover, the switch box of normal size 12"x8"x3" should be used. 1. Heater point with GI conduit (3/1 control) -02 Nos.
Supplying and providing wiring 5amp plug point using two runs of 2.5 sq.mm PVC insulated copper conductor along with 1.5 sq.mm copper wire for earthing and also including 5 Amps, two-in-one socket controlled by 5amp flush type switch on suitable Switch Box and connections.
Supplying of switch board and wiring 5 runs of 4sq.mm PVC insulated copper wire (phase and nuetral) and also for earthing and connection with 15Amps switch and socket combined with 15 Amps plug and 4P 63A MCV with encloser size for Battery point . This includes cost of materials and labour charges.
Supplying and providing wiring to Motor Room Points from motor to starter switch boxes using 2 runs of 4 sq.mm PVC insulated copper wire along with neutral PVC casing/PVC pipe not less than 25mm width with 2mm wall thickness including cost of materials, labour charger, switch board of size 18"x12"x3" with 16 Amps doublepole main switch and providing sufficient pace of providing and connections
Supplying and providing wiring with 2 runs of 4 sq.mm PVC insulated copper wire alongwith 2.5 sq.mm PVC insulatd copper wire for earthing inside the PVC rigid conduit not less than 25mm width and 2mm thickness for running circuit main from DB to all Switch Boxes, motors and inverter. Neutral should not be looped.Neutral in black and earthing in green to be followed.
Supplying and fixing, testing & commissioning of 300mm (12") dia AC Exhaust fan including wall bracket and accessories of standard make fixed on the wall and connections.
Supplying and fixing, testing & commissioning of 450mm 18" dia AC Exhaust Fan including wall bracket and accessories of standard make fixed on the wall and connections.
Supplying and fixing,testing & comissioning of with 12W LED decorative ceiling light Fitting
Supplying and fixing, testing & commissioning of 1200mm (48") AC ceiling fan complete set with electronic regulator and suitable down rod at 3 mts above floor level with connections etc.,
Supplying and fixing, testing & commissioning of Wall Mounted LED 18W LED 4' with necessary connections etc., of suitable for control room
Supplying and fixing, testing & commissioning of Mirror optical surface mounted light fitting with 2x2 43W LED Luminaire lamp and necessary fixing accessories of standard make and connections.
Supplying and fixing, testing & commissioning of Bulk head fitting with guard and 10W LED Bulb for duct lighting with necessary connections etc.,
Supplying and fixing, testing & commissioning of 120W LED Tr.light fittings for 120W LED with necessary connection edge of suitable for control room inclusive of labour charge edge
Supplying and fixing, testing and commissioning of 100W Board light fittings
Supplying and fixing,testing & comissioning of Gate light of post top lantern fittings of cylindrical of conical type suitable for 25W LED with necessary connections etc.,
Supplying and fixing, testing and commissioning of 25W LED street light fittings
Supplying and fixing,testing & comissioning of earth electrode as per specification. (AC, DC & Charger) 1.40mm GI Earth Pipe =3 mts 2.600x450x25mm RCC ring with cover =1 No 3.Charcoal =15kgs 4.Salt =10 kgs 5.Bentonite powder =50 Kgs
100W space heater
Battery charger change over switch
4Cx2.5 sq.mm control cable for yard lighting
GST for bidders within TamilNadu
SAI SATHYA ENGINEERING WORKS
Precision Electric Company
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .