Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC MEHEM ROAD NEAR TVS BIKE AGENCY GOHANA SONIPAT HARYANA 131301 ON MEHAM ROAD NEAR TVS BIKE AGENCY GOHANA 131301 | SONIPAT | HARYANA | 131301 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹24.0 L+₹96,592.71 (4.20%)Rejected-Finance | L2 | Rejected-Finance Higher rate to the contractor | |
| 3 | L3₹24.6 L+₹1.6 L (7.06%)Rejected-Finance | L3 | Rejected-Finance Higher rate to the Contractor |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
24 Jan 2022, 5:00 pmClosed
Executive Engineer (OS)
CCS HAU, Hisar
Repair/renovation of Seminar Hall in the premises of KVK, Rohtak (including EI work)
2022_HRY_202765_1
3271-C
Open Tender
Civil Works
Works
90 days
CCS HAU
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹44,000
Yes
7 May 2022
5 Jan 2022
25 Jan 2022
5 Jan 2022
24 Jan 2022
5 Jan 2022
Amount
Civil work 1 to 15:- Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (HSR 9.46.1)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm centre to centre and cross 'T' of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm centre to centre along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (HSR 9.47.1)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)
Distempering with 1st quality acrylic distemper (ready mixed) having voe content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work (HSR 11.65.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately} Kiln seasoned and chemically treated Hollock wood 35 mm thick shutters (HSR 12.7.2.1)
Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Fire retardant plywood conforming to IS: 5509 (HSR 12.11.2)
Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 4.0 mm thick glass panes (HSR 13.10.1)
Removing of existing damaged false ceiling with cradling/frame at all height (to be removed carefully) and shifting the same to maintenance store with a lead of 2 km, complete in all respect as directed by the Engineer-In-Charge. (NS)
Providing and fixing wall paneling (on wall) consisting of following:- (NS) Frame work:- Consisting of factory manufactured G.I. channel of size 43 mm x 15 cm x 0.8 mm fixed horizontally @ 2’-0” C/C with rawl plugs / screws on wall. (a) 12 mm thick WPC Board (ISI mark) of approved make fixed on G.I. channel frame. (b) Top portion:- Consisting of 0’-6” wide strips of 1 mm thick plastic laminated sheet (ISI mark) of approved make, shade and colour with 1/8’ groove fixed on WPC Board. (c) Beading:- Beading of size 0’-2¼” x 0’-1¾” of commercial hard wood such as hollock, champs, chikrasy and chaplash at top. Including cost of sprit polishing, rawl plugs, nails, screws etc., complete in all respects as per architectural drawing and design.
Electrical work 16 to 68:- MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. (HSR 23.6.6.1)
MS pipe of 25 mm dia. (HSR 23.6.6.2)
PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC Pipe of 20 mm dia. (HSR 23.7.6.1)
PVC pipe of 25 mm dia. (HSR 23.7.6.2)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules (HSR 23.8.10.1)
3 Modules (HSR 23.8.10.2)
4 Modules (HSR 23.8.10.3)
6 Modules (HSR 23.8.10.4)
8 Modules (HSR 23.8.10.5)
12 Modules (HSR 23.8.10.6)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (HSR 23.8.11.1)
15 amp 1 way switch (HSR 23.8.11.3)
5 amp Socket (HSR 23.8.11.4)
15 amp 6 pin Socket (HSR 23.8.11.5)
Step type Fan Regulator 2 modules 300 watt. (HSR 23.8.11.7)
Blanking plate (HSR 23.8.11.10)
RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11)
MCCB ,DISTRIBUTION BOARDS, MCB’s, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 125 to 160 Amp, 25 KA (HSR 23.22.1.4)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- SP MCB 6-32 AMP (HSR 23.22.5.1)
SPN MCB 6-32 AMP (HSR 23.22.5.3)
TPN MCB 40-63 AMP (HSR 23.22.5.6)
S/E of blanking sheet in existing distribution board. (HSR 23.22.7)
Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc.at both ends (Upto length of one metre):- Size 20 mm dia (HSR 23.23.1.2)
Size 25 mm dia (HSR 23.23.1.3)
Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia (HSR 23.23.2.1)
Supplying and drawing of 1no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required. (HSR 23.23.9)
DIMANTLING Dismantling of old wiring points (surface wiring system) including necessary repairs to wall etc. Light, fan or call bell Point in cluding circuit / sub sub main wiring. (HSR 23.25.1.1)
Wall socket Point in cluding circuit / sub sub main wiring. (HSR 23.25.1.2)
EARTHING AND LIGHTING ARRESTOR Earthing with G.I earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. as required. (HSR 24.1.1)
Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2)
Providing and laying earth connections from earth electrode with 4.00mm dia G.I. wire in 15mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)
Providing and fixing 4.00mm dia G1.Wire on surface or in recess for loop earthing as required. (HSR 24.1.13)
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. Size 1.5 sqmm. (NS)
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. Size 04 sqmm. (NS)
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. (NS) Size 06 sqmm.
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. i) 1400mm sweep. Make: Usha, Orient, Crompton (NS)
S/E of LED tube rod ≤20watt double side connections with 4 feet long housing made of CRCA sheet steel with epoxy powder coated white after phosphochromate treatment and 2 nos. lamps push fit type white polycarbonate holders and reflector made of white powder coated CRCA sheet total system lumen of 20watt LED should be ≥2200 or above in cool day light ( 5700K to 6500K ) PF > 0.95 , CRI >80 , Avg. life >50000 hours complete with mounting bracket and accessories as required with connections Make Philphis , Havells , wipro , Bajaj ( NS )
S.I.T.C of push ON/OFF type 25 A Modular type motor starter swithch ( white color) fr AC'S including the cost of petty meterial required to complete the job upto entire satisfaction of Engineer-in Charge. (NS)
S/E of recessed type 42 watt full window glare free opal difffuse LED panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600k to 6500k), Power factor >0.95, CRI (Ra) >80, LED lamp efficiency ≥140 lm/w, Average life >50000hours, complete with all accessories as required with connections.(Industrial) Make Havell's or Philiphs , Bajaj (NS)
S.I.T.C. of 86" Intractive flat Panel, IR touch technology, IPS Panel UHD Native Resolution ( 3849 x 2160 ), Brightness 330 Nits; Contrast ratio 1100:1, response time :8ms, Orientation Landscape Connectivity. ( Input ) Video / Audio HDMI (3), RGB / Audio in(input) External Control rS232C In,RJ45 (Input) USB USB 2.0 (3, Front : 2ea, Bottom side :1ea Only for software. Audio HDMI (1), Optical Output / Audio Out with OPS i5 system Touch type IR. Available object size for touch Ø3 mm ↑ Response Time 60ms ↓ (Andriod) / 100ms ↓ (Windos) Accuracy 1.5mm Unreface USB 2.0 Protection Glass Thickness 4T (Anti - Glare) Make Panasonic,Samsung,LG, Sony, View Sonic etc. (NS)
S.I.T.C. of Intractive Digital Podium system with 16" intractive screen EMR technology, also available Goosneck Microphone inbuilt Aluminium plated system Interface : USB, Pressure sensitive. Still image Resolution : XGA,SXGA,720P,1080P FRAME RATE 20 FRAMES/SEC. Image Mode: Normal/Photo/Text/Slide/Film/Gray. Inputs-VGAx2, HDMIX 1 Video x 2, Audio x 2 Outputs - VGA x 2, hHDMIx 1 VIDEO X1 AUDIO X1. Make AHA/Digital Multimedia Podium etc. (NS)
Supply installation testingan commissioning of wall free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet required hardware 3 mm thick bakelite sheet providing all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/Red oxide primer followed by 2 coats of powder cating in grey or required shade after rinsing. the panle having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/ switch wear.Transparent arcylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra tiems side walls and cable alley compartments shall be haiving bolted type doors with detachable extension type strcture. the panel will be complete with control wiring ( copper) and fuse protection ( only outer area on all sides shall be measured ) (NS)
Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing go same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat srinkable PVC insulation complete in all respect. (NS)
Suppy,Installation,Testing and Commissioning of Automatic voltage stablizer of single phase 5.00 KVA capacity copper wound heavy duty 100 volt up of Logicstate,Bluse star, V-guard make ISI mark complete in all respect. (NS)
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-410/ R-32 suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1450 cum/ hr. (iii) Sound level (H/M/L)- 41/38/34/25(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Toshiba/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge. (NS)
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 metres length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four metres length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 metres of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit. (NS)
Providing and fixing in position powder coated MS stands for outdoor units of air conditioners including suitable nuts & bolts etc. of best quality complete in all respect (NS)
Dismantling of old AC unit capacity 2.00 Ton completely with indoor and outdoor unit and return to store. (NS)
SITC Speaker - EN-54-24 certified 20W wall mount speaker with excellent speech & High - fidelity music reproduction Max Power : 30W, Rated Power : 20Watts, Power Tapping : 20/10/5/2.5 Effective frequency Range(-10 db) : 90Hz to 20KHz SPL rated power (I khz at 1 m) 101 db, Opening Angle 1 khz / 4khz (-6db) : 174⁰ / 136⁰ (hor.) 127⁰ / 141⁰ (ver.) Woofer :- 5 inch ; tweeter 1 inch; Cabinet and front grill :- aluminium, Operating temp. : -25⁰ to +55 ⁰ ; RH< 95% EN60065; UL 94 V0 ; Water & dust protection :- EN60529 IP-65. Make : Bosch/ Bayerdynamics / Senneheiser etc. (NS)
Power Mixer - SITC of Powered Mixer ideal for installs with inbuilt class D amplifier , max. midband output power, 1 khz, THD = 1%, dual channel into 4Ω : 2 x 450 W into 8Ω : 2 x 270 W, also capable of Direct - Drive option for 100V speaker lines. Frequency reponse, -3db, ref. 1khz, any input to any Mixer output 15-22000 Hz. Crosstalk , 1khz Ampifier Ch1/Ch2˂ -85 db. 5 MIC/LINE input channels with compressor / limiter and talk over function, 3 Stereo inputs including jack, RCA and USB connecters, onboard player for MP3 or WAV audio files, high quality effects section with 32 editable presets, 3 master outputs with 7-bands EQ each and flexible signal routing options, delay line for Master-B (150msec) / 50m), Auxiliaries (FX,AUX) 1 Post 1 Pre, Input impedences MIC 2kΩ Cd 10kΩ All other inputs ˃ 15kΩ, headphones control, LPN speaker processing, comprehensive protection package, optional rack ,ount kit. Make Bosch /Bayerdynamics / Senneheiser etc. (NS)
Supply Installation testing & commissioning of 17U Server rack with Accesserieoes including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge. (NS) MAKE :VPRO/Dlink/I-DYNAMIC
Supply, Installation, Testing and Commissioning of XLR cables -of different sizes : Male,females, Speakon connectors, conducting, solding etc . (NS)
Supply, Installation, Testing and Commissioning of HDMI Cable 10 Meters For Lecture Hall : High Speed HDMI Cable; Ethernet, 3D, 4K, Audio Return Supported;Gold Plated Connector; Bare Copper Connector for high quality transmission; full metal jacket with shielding; 0% transmission loss. (NS) MAKE : Stacker/Aten/Kramer/TEKWIN/WBOX
the creative infra and interiors pvt. ltd.
M/s Parmesh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .