Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹1.3 Cr
EMD Value
₹1.9 L
Closing Date
7 Mar 2024, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Transmission Corporation Limited
Amaravathi N
Replacement of damaged 400kV DB plus 0 wind zone 2 tower by new tower at location no 21 of Udupi Hassan line coming under TLSS Division Kemar Karkala
KPTCL/2023-24/TL/WORK_INDENT676
KPTCL/2023-24/TL/WORK_INDENT676
Open
Transmission Line
Two Tender Document System(Two Cover)
KPTCL SEE Works and Mantainance Circle Mangalore
12 documents required · 12 mandatory
a)Should have experience in the work of replacement of towers (at least one tower) in 400 kV lines on Total Turnkey basis or Partial Turnkey basis. OR b)Shall be a Labor Contractor or Sub-Contractor of a Turnkey Contractor and who has executed the work of replacement of towers (at least two towers) in 400 kV on Total Turnkey basis or Partial Turnkey basis. OR c) Should have successfully completed construction of 400kV Transmission Line (at least 01 Kmtr) or above voltage reference on Total Turnkey basis or Partial Turnkey basis. OR d)Should have successfully completed construction of 400kV Transmission Line (at least 01 Kmtr) or above category under Labor contract or as Sub-Contractor under collaboration with a Turnkey Contractor. The bidder should furnish satisfactory work done certificate issued by officer not below the rank of Executive Engineer or Equivalent.
The Bidder or his consortium partner should possess valid Super Grade Electrical Contractor License or equivalent issued by the appropriate authority as on the date of Bid Submission
Minimum Average Annual Turnover (MAAT) of the bidder for best three years out of last preceding five financial years (2018-19,2019-20,2020-21,2021-22,2022-23) ending on March or December as the case may be, shall not be less than Rs. 194.75.00 Lakh
All technical documents mentioned in tender documents should be uploaded. If not uploaded bid will be rejected.
As per tender documents
As per tender documents
As per tender documents
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the preceding five years. A consistent history of awards involving litigation against the Bidder may result in rejection of bid
As per tender document
As per tender document
As per tender document
As per tender document
As per tender document
As per tender document
As per tender document
₹3,250
₹1.9 L
21 Feb 2024
21 Feb 2024
8 Mar 2024
6 Mar 2024
28 Feb 2024
Replacement of damaged 400kV DB plus 0 wind zone 2 tower by new tower at location no 21 of Udupi Hassan line coming under TLSS Division Kemar Karkala
Fabrication, Galvanising and Supply of High tensile steel Tower Materials
Fabrication, Galvanising and Supply of Mild steel Tower Materials
Supply of Galvanised Bolts & nuts Weight =0.7247MT (Normal tower)
Phase plate ( set of 6nos per Tower)
Caution plate / Danger Board (1 No per Tower)
Number plate ( 1 No per Tower)+ Circiut plate (2nos)
Spacer Dampers for Quad Conductor (Bundle spacers for line)
Rigid Spacers for jumpers
160kN Tension Type composite Polymer Long Rod insulators with sectional length -3910mm
120kN Suspension type composite polymer long Rod insulators with sectional length -3335mm
Repair sleeve for moose conductor
Repair sleeve for 7/3.66mm earth wire conductor
Sorting of tower parts made of fabricated angle iron
Assembling and errection of towers including tightening of bolts and nuts , loading, unloading at store and site.
Welding of tower Bolts & Nuts, Approximately 500 Bolts and Nuts per tower upto height of bottom crossarm as per direction of field Engineer.
Fixing Danger Board (1 No per Tower).
Fixing Number plate ( 1 No per Tower).
Fixing Phase plate ( set of 6nos per Tower)
Fixing Circuit plate (2nos).
Supplying and fixing G.I Angle Iron 45 x 45 x 5 mm (1 Mtr. Length) with cleats, bolt & nuts as per specification and fixing above 0.5 m length each at inner and outer surface of the tower to facilitat...
Supplying and fixing barbed wire as per specification.16mtrsX4sidesX 6 rounds/Tower ) = 384 mtr.
De- Stringing of ACSR conductor withoout allowing the conductor to touch the ground and without damaging the Quad conductor , Anchors are from Loc.No 19 to 21=702 mtrs and Loc.No. 21 to 22=417 mtrs =7...
De- Stringing of ground conductor, Anchors are from Loc.No 19 to 21=702 mtrs and Loc.No. 21 to 22=417 mtrs=702+417=(1119+1.5% sag )x2=2.27kM
Stringing of ACSR Conductor without allowing the conductor to touch the ground and without damaging the Quad conductor. Anchors are from Loc.No 19 to 21=702 mtrs and Loc.No. 21 to 22=417 mtrs=702+417=...
Stringing of ground conductor, Anchors are from Loc.No 19 to 21=702 mtrs and Loc.No. 21 to 22=417 mtrs=702+417=(1119+1.5% sag )x2=2.27kM
Dismantling of 400KV , Double circuit ‘B+0’ type GI towers 75% of erection charges weight calculation: Tower weight= 24.8381 less 10%(due to corrosion=2.48381MT) = 24.8381-2.48381 =22.3543MT say a...
Loading and Unloading of Dismantled tower,
Tower wt= 22.00MT
Transportation of Dismantled tower to KPTCL stores, Kavoor, Mangaluru [ 125 Kms] using Truck and Trailer
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
2 IFB-400kv.pdf
Tender Document • 0.72 MB
1 nit-400kv.pdf
Tender Document • 0.24 MB
6 ECC-400kv.pdf
Tender Document • 0.33 MB
technocommercialsheet 400kv.xls
Techno-Commercial Worksheet • 0.65 MB
Annexure.doc
Others - Annexures • 0.16 MB
5 SCC-400kv.pdf
Tender Document • 0.41 MB
Drawings.zip
Design Document • 40.25 MB
4 GCC-400kv.pdf
Tender Document • 0.37 MB
3 ITB-400kv.pdf
Tender Document • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .