Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹23.6 L+₹86,890.42 (3.82%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Due to higher rates | |
| 3 | L3₹23.8 L+₹99,238.05 (4.36%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L3 | Rejected-Finance Due to higher rates |
Tender Value
₹23.8 L
EMD Value
₹47,600
Closing Date
24 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSAM
SPECIAL REPAIRS TO ELECTRICAL LT DISTRIBUTION SYSTEM AND ALLIED WORKS AT LEKHAPANI MIL STN UNDER GE LEKHAPANI
2022_MES_554413_1
8699/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category b (i)
4 documents required · 4 mandatory
₹500
GE LEKHAPANI
₹47,600
Yes
21 Nov 2022
26 Sept 2022
31 Oct 2022
26 Sept 2022
24 Oct 2022
10 Oct 2022
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for laying of cable, pipes etc and getting out in soft/loose soil complete all as specified and directed.
All as per Item No. 1 above, but depth exceeding 1.5 m and not exceeding 3 m.complete all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm of soil complete all as specified and directed.
Removing the surplus excavated materisl/soil to a distance not exc 50 mtrs and depositing, where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and spread sand for sand cushioning of cables in trenches all as specified in MES Schedule Part-I complete all as specified and directed. Note: Punned thickness only will be measured and paid.
Supply and lay in trenches, old burnt sub class 'B' bricks as specified in MES Sch part-I complete all as specified and directed.
S&F GI tubing 80 mm bore, (light grade), galvanised, ISI marked with all fittings,specials for cable protection on road crossing/floor etc duly sealed at both ends after drawing cable complete all as specified and directed.
S&F GI tubing 50 mm bore, (light grade), galvanised, ISI marked with all fittings,specials for cable protection on road crossing/floor etc duly sealed at both ends after drawing cable complete all as specified and directed.
S&F GI tubing 40 mm bore, (light grade), galvanised, ISI marked with all fittings,specials for cable protection on road crossing/floor etc duly sealed at both ends after drawing cable complete all as specified and directed..
M&L PCC (1:4:8) type D2 (using using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&LPCC (1:3:6) type C1 ( using 20 mm graded crushed stone aggregate) as in coping including necessary form work and finishing exposed surface/white washing complete all as specified and directed.
M&L PCC (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in kerbs or mud stops, roundd or chamferred on edges including necessary form work complete all as specified and directed.
Supply,laying and testing of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 3.5 core,120 sqmm as laying or passing through pipe/ wall/ floor/ trenches, complete all as specified and directed.
All as per Item No. 13 above but,size 3.5 core 95 sqmm complete all as specified and directed.
All as per Item No. 13 above but,size 3.5 core 50 sqmm complete all as specified and directed.
All as per Item No. 13 above but,size 4 core 25 sqmm complete all as specified and directed.
All as per Item No. 13 above but,size 2 core 6 sqmm complete all as specified and directed.
M&L Providing Heat shrinkable LT straight through joining kit including materials all as required for LT cable size 95 sqmm 3.5 core complete all as specified and directed.
All as per item No 18 above,but of size above 25 sqmm but up to 50 sqmm, 3.5/4 core complete all as specified and directed.
All as per item No 18 above, but size from 6/10 sqmm up to 16 sqmm, 2/3.5/4 core complete all as specified and directed.
S&F Cable route indicator oval shaped size 200mm x 150mm x 6mm thick CI with letter embossed as HT/LT UG cable fixed on 25mmx 25mmx 6mm MS angle iron of 50 cms long embedded in PCC block 200mmx 200mm x 200mm PCC 1:3:6 type C1 using 20mm stone aggregate including 2 coats of synthetic enamelled paint over a coat of zinc chrome primer on exposed surface complete all as specified and as directed.
M&L for fabrication, testing and commissioning of factory made LT panel board made out of CRCA sheet 3.15 mm thick of size 1500x1000x450mm, double door type totally enclosed with front opening hinged doors with canopy sloped top projected and Plinth mounted, weather and water proof as per IS-8623 Aluminium bus bar with phase and neutral, insulators suitable for 3 phase 4 wire LT AC, 50HZ, 433 volts, 300 Amps, capacity complete with necessary locking arrangement and measuring devices such as volt meter ,ammeter,power factor meter including painting with two coats of synthetic enamel paint over a coat of primer red oxide internal electric connections as required with suitable size cables, stainless steel cable glands for incoming and outgoing cables, taking down old unsv feeder pillar box and provision of the following:- (a) MCCB 250 Amps, fixed thermal magnetic release type, 35 kA, AC 50 Hz, 4 pole - 01 No (Incoming) (b) MCCB 200 Amps, fixed thermal magnetic release type, 35 kA, AC 50 Hz, 4 pole - 01 No (outgoing) (c) MCCB 160A,fixed thermal magnetic release type, AC 50 Hz, 16KA , 4 pole - 2 Nos (outgoing) (d) MCB SPN 32 Amps, AC 50 Hz - 02 Nos (e) Digital type timer switch, 230 Volts, 50 HZ and Contactor 40 Amps capacity three phase, 415 Volts 50 HZ suitable for 3 phase distribution with auto manual switch -01 Each. (f) Indication lamp (R,Y,B), LED type, with toggle switches - Set of 3. (g) Multi-function meter, three phase, digital type, with parameters like voltage, ampere, Frequency, PF, KW, KVA etc, - 01 No. (h) Civil work as required for panel mounting - 01 Job
M&L for fabrication, testing and commissioning of factory made Feeder Pillar Box made out of CRCA sheet 3.15 mm thick of size 1000x1000x450mm double door type totally enclosed with front & back opening hinged doors with canopy sloped top projected and Plinth mounted , weather and water proof as per IS-8623 Aluminium bus bar with phase and neutral, insulators suitable for 3 phase 4 wire LT AC, 50HZ, 433 volts, 200 Amps, capacity complete with necessary locking arrangement and measuring devices such as volt meter, ammeter, power factor meter including painting with two coats of synthetic enamel paint over a coat of primer red oxide internal electric connections as required with suitable size stainless steel cable glands for incoming and outgoing cables, taking down old unsv feeder pillar box and provision of the following:- (a) MCCB 100 Amps, fixed thermal magnetic release type, AC 50 Hz, 25 KA, 4 pole - 01 No (Incoming) (b) MCCB 63 amp, 415 volts, 10 KA 4 pole with fixed thermal and magnetic release-3 Nos (Outgoing) (c) Indication lamp (R,Y,B), LED type, with toggle switches - Set of 3. (d) Multi-function meter, three phase, digital type, with parameters like voltage, ampere, Frequency, PF, KW, KVA etc, - 01 No. (e) Civil work as required for panel mounting - 01 Job
M&L Earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways and testing on completion,etc complete all as specified and directed by Engineer-in-Charge.
S&F Energy effecient LED street light fitting 60 watt complete with high power LEDs as light source with peanut lens for uniform distribution, prewired, with suitable mounting GI bracket incl taking down old unserviceable light fittings all as specified and directed.
M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
S&F Fibre body loop in loop out enclosure of size 140 mm x 140 mm x 95 mm consisting of HD bakelite connector strip including MCB 6 Amps SPN fixing of enclosure with pole/wall using 40 x 6 mm size MS FI clamps of required shape with bolts, nuts & washers complete all as specified and directed.
S&F PVC insulated Aluminium conductor cable of twin core 2.5 sqmm drawn in rigid PVC conduit not less than 20 mm dia fixed along pole with suitable size clamps for connecting street light fittings from Junction box complete all as specified and directed.
Dismantling concrete poles/ struts, any size and transportation to store yard for stacking complete all as directed by Eng-in-charge.
Dismantling of ACSR conductors and jumpers from LT OH lines/structures complete all as directed by Eng-in-charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as directed by Eng-in-charge.
Dismantling LT insulators any type, any size complete all as directed by Eng-in-charge.
M&L stay assembly complete with stay rod 16 mm dia and all accessories as shown in electrical plate No 1 of SSR Part I (2009) including 01 x loop type insulator and stay clamp all as specified and directed. Note :- Excavation and PCC will be measured and paid separately.
S & F Aluminium Bus bar chamber of capacity 63 Amps, four pole, 415 volts, AC supply, mounted on DMC type insulators, totally enclosed with rigid PVC enclosure, complete including opening for cable entry complete all as directed by Eng-in-charge.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure al as specified and directed.
MAA COMMUNICATION
RIA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .