Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 19 SAINIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | MADHYA PRADESH | 462030 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹30.7 L+₹6.6 L (27.7%)Rejected-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹31.9 L+₹7.9 L (33.0%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹33.8 L+₹9.7 L (40.6%)Rejected-AOC | L4 | Rejected-AOC Not Lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical No Remark in WLR |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
24 Oct 2024, 6:00 pmClosed
GE (AF) Amla
GE (AF) Amla, Amla depot Dist Betul (MP) 460553
Repair/Maint to external water supply CI and GI pipe line Sluice valves gate valves connected works at X area at AFS Amla
2024_MES_676515_1
8597/E8 OF 2024-2025
Open Tender
Civil Works
Item Rate
335 days
GE (AF) Amla
Please refer Tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Amla
₹60,000
Yes
19 Dec 2024
25 Sept 2024
28 Oct 2024
25 Sept 2024
24 Oct 2024
9 Oct 2024
Amount
Dismantling and removing damaged/broken valve chamber brick masonry PCC coping, Pits of valve chambers and removing from site to a distance exc 50 mtr but not exc. 100 mtr all as directed
M&L for valve chamber of size 1500mmx 1000mmx1000mm (Internal) with brick masonry 230 mm thick in CM 1:6, PCC 1:4:8 type, D2 foundation 75 mm thick, finished fair and even, PCC 1:2:4 type, B1 coping 150 mm thick on top of brick wall for fixing chamber cover, 10 mm thick cement mortar 1:4 plaster on exposed surfaces of brick wall (both internal and external), mild steel plate cover of 3.15mm including mild steel angle iron 40x40x6 mm size frame fixed to PCC coping with the same size of angle iron hold fast and with necessary handle and locking arrangements, metal surfaces duly painted with black bituminous paint over a coat of red oxide zinc chrome primer and finishing the masonry/concrete surfaces with 3 coats of white wash including necessary excavation and earth work complete all as specified and directed.
Removal of bio-degradable bee-hives wild growths from the structure tank and member of the overhead reservoir complete including wild bees with suitable application of fuming smoke or chemical fog application and applying a cost of alergent for keeping away or return of bee-hives (All the bee-hives on the tank shall be removed and cleaned) Note : The removal of bee-hives shall be carried out with total precautions so that wild bees do not get the time and facility to attack the public in the locality.
Excavation of trenches/pits (in any type of soil) n exc 6 mtr in length 2.5 Mtr wide and upto 2.5 mtr in depth with manually and getting out the leakage water by using diesel engine pump set/motor/manually for complete de watering from the tranches and repairing leakages in pipe line/NRV/Air Release valves in position for repairing the area/trench for jointing/repairing the leakages of any sizes upto 300mm bore of pipe with mechanical joint including returning filling in trenches all as directed.
Taking up or down (from wall/trench/floor) existing steel tubing and connections including cleaning with iron rod and wire brush for refixing or remove to MES store of following sizes: -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Refixing of old steel tubing and connections in new or old position including cleaning internally and externally, cutting threading, any grade/make in trenches /on walls, celling, floors including all new type of fitting i.e. sockets, Tea, union, elbow etc all as sprcified and directed at site for following sizes: -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Supply, Fixing and laying in repairs only GI tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all such as tee, bends union elbow reducer etc required at site: -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Cutting Existing steel tubing in position for alteration or additions as per site (each cut measured) in any condition all as specified and directed of following size:-
15 mm bore
20 mm bore
25 mm bore
40 to 50 mm nore
Taking down and supply and fix gun metal valve, cast screwed down, hiogh pressure with iron wheel handle, screwed both ends for iron pipe or unions of the following size: -
50 mm bore
40 mm bore
25 mm bore
20 mm bore
15 mm bore
M&L for repairs/rectification of leakage in UG cast iron pipe lead joint by caulking lead wool/pig lead complete including excavation and earth work for exposing the joints and working space on the site, returning filling in and making good to the existing earth level of the surroundings after repair for the following sizes of pipes all as specified and directed. Note: (a) Cost including excavation, returning, refilling (b) In case of any leakage on the same joint contractor will be rectified without any financial effect with in six months.
do-but 80 mm dia bore
do-but 100 mm dia bore
do-but 150 mm dia bore
do-but 200 mm dia bore
M&L for Run leaded joint for spigot and socketed end of cast iron pipes of size 80mm dia bore all as specified and directed.
M&L for Run leaded joint for spigot and socketed end of cast iron pipes of size 100mm dia bore all as specified and directed.
M&L for Run leaded joint for spigot and socketed end of cast iron pipes of size 150mm dia bore all as specified and directed.
M&L for Run leaded joint for spigot and socketed end of cast iron pipes of size 200mm dia bore all as specified and directed.
Taking up cast iron or Ducting iron water mains (including all fittings), with spigot and socket, flange ends and lead joints including burnings out joints and recovering lead of following sizes:-
do-but 80 mm dia bore
do-but 100 mm dia bore
do-but 150 mm dia bore
do-but 200 mm dia bore
Re-laying Cast iron pipes with spigot and socket ends cenrifugally cast, Class LA in any length laid in trenchs of following sizes: -
do-but 80 mm dia bore
do-but 100 mm dia bore
do-but 150 mm dia bore
do-but 200 mm dia bore
Supply and fix cast iron pipes with spigot and socket ends cenrifugally cast, Class LA in any length laid in trenchs, tee, socket, elbow, uninion, site requirement including all items of following sizes: -
do-but 80 mm dia bore
do-but 100 mm dia bore
do-but 150 mm dia bore
do-but 200 mm dia bore
Cutting cast iron pipes and reducing to required length before laying all as specified and directed.
do-but 80 mm dia bore
do-but 100 mm dia bore
do-but 150 mm dia bore
do-but 200 mm dia bore
Screwing existing steel tubing for addition or alterations all as specified and directed at site for following sizes: -
15 mm bore
20 mm bore
25 mm bore
40 to 50 mm nore
S&F in repair 150 mm bore; M. S. pipe heavy duty Class 'C' ISI marked & including cutting, screwing welding etc. with all fittings as rtees, elbows reducers, flanges U Bolts, wire ropes etc. painting with one coat of primer and two coats of synthetic enamel paint complete all as specified and directed.
Supply and fix in repair non return valve of following size cast iron body with by-pass arrangement confirming to IS with jointing and jointing materials such as rubber gasket, nut, bolt, washer all as specified.
200 mm dia bore
150 mm dia bore
100 mm dia bore
80 mm dia bore
Taking down and supply and fixing Mechanical joint made out of MS sheet of thickness not less than 10 mm fabricated as per existing site requirement including long MS bolt, rubber gasket, cutting/fixing of pipe in position of any size CI/MS/AC pipe with the help of manually as well as mechanical T & P complete all as directed of following sizes: -
do-but 80 mm dia bore
do-but 100 mm dia bore
do-but 150 mm dia bore
do-but 200 mm dia bore
M&L for taking out sluice valves, top cover, spindle and broken/unserviceable check nut/gutka carry to workshop and refixing of sluice valve after servicing /maintenance /griding/greasing work to sluice valve parts, including replacement of gland packing, rubber sheet, nut bolt and washer of existing size complete all as specified and directed.
do-but 80 mm dia bore
do-but 100 mm dia bore
do-but 150 mm dia bore
do-but 200 mm dia bore
S&F in repairs 80mm size butterfly valve suitable for pressure rating PN 1.6 Mpa, conform to standard API609/BSEN 593 (BS 5155) complete with all accessories including taking down old butterfly valve all as specified and directed.
S&F in repairs 100mm size butterfly valve suitable for pressure rating PN 1.6 Mpa, conform to standard API609/BSEN 593 (BS 5155) complete with all accessories including taking down old butterfly valve all as specified and directed.
S&F in repair Rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed at site:- Make: Sintex, Polycon, Jaipur, Rotex
500 Ltr cap
1000 Ltr cap
2000 Ltr cap
S&F in repair for PVC float valve high pressure with polythene float and fly nut complete, screwed for iron pipe or brass fenle and fixed in all as specified and directed of following size: -
15 mm bore
25 mm bore
25 mm bore
S&F in repair in position sluice valve confirming to IS 780/IS 14846- 2000 PN, 1.6 flanged and S/S spindles with cap & handle wheel opening arrangment of sizes given below with all nuts bolts, washer and rubber packing of existing size including taking down existing sluice valve and deposited to E/M store yard. Make: SIR, KIRLOSKAR, LEADER
do-but 80 mm dia bore
do-but 100 mm dia bore
do-but 150 mm dia bore
do-but 200 mm dia bore
do-but 250 mm dia bore
Material and labour CI fittings such as bends (any type radius and angle), tee pieces, single branch ‘Y’ Junction, double branch, cross (all sockets or socket & spigot), collars, caps & piugs etc for spigot and socketed CI pipes of size uoto 150mm bore all as specified.
Excavation in trench not exceeding 1.5 Mtr in depth and not exceeding 1.5 Mtr in width and getting out in soft/loose soil.
Returning filling in including spreading, levelling watering and well ramming in layers not exceeding 25 cms by using excavated soil.
Removing surplus spoil to a distance not exceeding 50 m and depositing where directed at level not 1.5 m above starting point.
Note:- The amount against the Schedule of Credit mentioned in the tender document shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
Raj Construction (BID ID -3148375)
Vee kay construction (BID ID -3141651)
M/s SHAKTI INFRASTRUCTURE (BID ID -3148857)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .