Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹17.1 LAdmitted-Finance 2628 KUCHA CHALAN DARYA GANJ NEW DELHI 110002 | CENTRAL | DELHI | 110002 | L1 | Admitted-Finance | ||
| 2 | L2₹18.0 L+₹88,971.44 (5.19%)Admitted-Finance | L2 | Admitted-Finance |
Tender Value
₹22.8 L
EMD Value
₹45,626
Closing Date
12 May 2026, 3:00 pmClosed
Executive Engineer (E)
EEE PWD DHC and ND/Central G.F. MSO Bldg. ND
1) RMO Electrical and Mechanical services installed at Trade and Taxes Building, New Delhi. 2) RMO Electrical and Mechanical Services installed at MSO Building, I.P.Estate, New Delhi. (SH Fixing of drain pipes and Trays for STAC/WTAC)
2026_PWD_290768_1
24/EE(E)/PWDDHC,ND/C/2026-27
Open Tender
Electrical Works
Works
30 days
New Delhi
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹45,626
15 May 2026
4 May 2026
12 May 2026
4 May 2026
12 May 2026
4 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying & replacement of drip tray suitable for Window Type Air Conditioner fabricated with minimum thickness 20 SWG G.I. sheet of suitable size as per as requirement on site with fixing hooks having nipple at the bottom / back etc. complete as reqd. i/c credit for old dismantle material under buy back. | 220 | Nos. | 300 | ₹66,000 |
| 2 | Supplying & replacement of 25mm dia. REINFORCED FLEXIBLE PVC PIPES along with accessories such as funnel in the existing AC, to be fixed on wall by providing proper fixing clamps etc. complete as required i/c credit for old dismantle material under buy back. | 250 | Meters | 125 | ₹31,250 |
| 3 | Providing & fixing of following size (SDR-13.5) UPVC heavy duty white colour drain pipe of with necessary fitting such as nipple, reducer, clamp, elbow, socket, T etc. on surface / recess i/c cutting the wall and making good the same complete as required. The work shall be done at a height upto 15 meters. Necessary scaffolding to be done by agency for installation of the same.
External work
a) 25 mm Dia | 1,100 | Meters | 195 | ₹2,14,500 |
| 3.01 | b) 50 mm Dia | 900 | Meters | 400 | ₹3,60,000 |
| 4 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. | 600 | Sq.Meters | 338.25 | ₹2,02,950 |
| 5 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of
the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature)
Inverter Type - Cooling only
5.01) 1.5 TR with 5 Star BEE Rating | 5 | Nos. | 43,539 | ₹2,17,695 |
| 5.01 | 5.02) 2.0 TR with 5 Star BEE Rating | 5 | Nos. | 57,396 | ₹2,86,980 |
| 6 | Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P &labouretc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature).
Inverter Type
6.01) 1.5 TR with Inverter 5 Star BEE rating | 8 | Nos. | 40,074 | ₹3,20,592 |
| 7 | Supplying, Installation, Testing and Commissioning of Air Cooled Floor standing Tower type split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 5.5 Mtr (IDU to ODU), i/c drain pipe of suitable length and size. R-32/R-410/R-407C Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA) with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.
Cooling Only
7.01) 3.8 TR BEE 5 Star Rating | 1 | Nos. | 1,10,025 | ₹1,10,025 |
| 8 | Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain pipe, the system shall be capable of performing cooling, dehumidification, Air circulation, filteration& ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required.
Inverter Type- Cooling only
8.01) 2.0 TR with 5 Star BEE Rating | 2 | Nos. | 85,731 | ₹1,71,462 |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.65 MB
BOQ_385824.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .