Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC QUOTED RATED ADMISSIBLE HENCE ACCEPTED | |
| 2 | L2₹29.2 L+₹2.3 L (8.48%)Rejected-Finance NO 21 BRAMIN STREET KORATTUR CHENNAI 600080 | CHENNAI | CHENNAI | TAMIL NADU | 600080 | L2 | Rejected-Finance L1 BEING ACCEPTED |
Tender Value
₹25.8 L
EMD Value
₹51,700
Closing Date
20 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (I)(CG) Chennai
Garrison Engineer (I)(CG) Military Engineer services Second Floor CG DHQ No 5(TN) No 4 and 4 A Clive Battery complex Rajaji Salai Chennai 600001
ADDITION/ALTERATION TO COAST GUARD OFFICERS MESS AT CGRA, THALAKANCHERRY CHENNAI UNDER GE(I) CG CHENNAI (SPECIAL WORK)
2022_MES_522174_2
8935/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (I)(CG) Chennai
All as per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹51,700
Yes
5 Jul 2022
7 Jun 2022
22 Jun 2022
7 Jun 2022
20 Jun 2022
8 Jun 2022
60 days
Amount
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing ) including removing serviceable tiles to store and rubbish off the premises not exceeding 2 Km complete all as specified and as directed.
Material and labour for screed of 15mm thick in CM (1:6) for laying floor tiles etc complete all as specified and as directed.
Material and labour for rendering of 10 mm thick in CM (1:3 ) for laying of skirting/dado on walls etc complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided and removal of debris off the premises outside the MD land complete all as specified and as directed.
Material and labour for Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
Material and labour for Precast cement concrete Type-B1(1:2:4 ) (using 20 mm graded stone aggregate) as in man hole covers/gully trap cover slab set in cement mortar 1:4 including necessary /form work complete all as specified and as directed.
Material and labour for Granite stone 18 to 20 mm thick (of any type) work (table rubbed and polished) in single piece in steps, jambs, pillars, window- cills, cooking platforms and in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding edge complete all as specified and as directed.
Material and labour for Designar wall cladding as split natural stone, polished or rough face of any colour of thicknesss 10-15 mm in vertical surface of any size and any thickness set and jointed in neat cement slurry and pointed in white or colour cement to match with the existing surface complete all as specified and directed.
Supply and Fix stainless steel letters of size 1' feet x 9"inches incuding necessary fixing arrangements complete all as specified and as directed.
Supply and fix 4 mm thick ACP (Aluminium Composite Panel) board with suitable size grade HB-1, 0.50 mm skin coated with PVDF available in different patterns such as solid,metallic,high gloss ,matt finish ,wooden finish etc secured over aluminium section minimum size 25x50 mm grid fixed on wall with rivets and filling 5-8 mm gap with silicon or epoxy based grouting as per the colour matching requirement complete all as specified and as directed.Make: Armstrong or Equivalent as approved by GE.
Supply and Fix Aluminimum collapsible partition with toughned glass 12 mm thick tinted or clear with suitable section and including necessary fixing arrangements complete all as specified and as directed.
Supply and Fix (with help of suitable pins and adhesive)Rubber pillar guard of height 1000 mm with yellow and black reflector complete all as specified and as directed.
Supply and Fix speed bumps with help of suitable pins and adhesive having 1m length with 50mm hump and with yellow and black reflector complete all as specified and as directed.
Material and labour for Preparation of newly plastered surface of wall including pilasters and cornice etc and apply two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over surfaces complete all as specified and as directed.
Supply and fix Stainless steel designer gate (SS Grade 304) Openable with stainless steel frame all around of 2 mm thick,Ornamental and intricate design with pintol hinged and locking arrangements including SS Channels duly welded and buffed complete all as specified and as directed.
Dismantling of Rain water pipe and Sewage pipe line of any type and description including fittings and rubbish off the premises to a distance not exc 2 km and depositing where directed and serviceable items taken as credit complete all as specified and as directed.
Supply and fix PVC (SWR) pipes of bore110mm single socketed in any length with rubber ring joints, laid in trenches or in floors/fixed in walls complete all as specified and as directed.Make:Finolex/Trubore/Supreme
Supply and fix PVC (SWR) pipes of bore 75 mm single socketed in any length with rubber ring joints, laid in trenches or in floors/fixed in walls complete all as specified and as directed.Make:Finolex/Trubore/Supreme
Supply and fix 110 mm dia PVC (SWR) bends any radius fitted with oval access door complete all as specified and as directed.Make:Finolex/Trubore/Supreme
Supply and fix 110 mm dia PVC (SWR) bends any radius complete all as specified and as directed.Make:Finolex/Trubore/Supreme
Supply and fix 75 mm dia PVC (SWR) bends any radius fitted with oval access door complete all as specified and as directed.Make:Finolex/Trubore/Supreme
Supply and fix 110 mm dia PVC (SWR) reducer any radius complete all as specified and as directed.Make:Finolex/Trubore/Supreme
Supply and fix 110 mm dia PVC (SWR) junction single(singleT ) equal or unequal complete all as specified and as directed.Make:Finolex/Trubore/Supreme
supply and fix LED light fitting surface mounted 9/10 W Wall light (down light or up light) with die cast aluminium housing designed for rugged outdoor usage and IP 65 protection suitable for focusing on wall cladding and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified. Make: Bajaj BLWUP 9W LED WW or equivalent in Philips/wipro/crompton/Havells
Supply and fix MCB 10 KA, 240 Volts, C curve MCB of single pole and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . Make:- C&S/HPL/Legrand
Supply and fix MCB 10 KA, 240 Volts, C curve MCB of single pole and neutral and current carrying capacity 40 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed . Make:- C&S/HPL/Legrand
Supply and fix sheet metal enclosure for single Pole and neutral distribution board with 200 Amps rated bus bar SPN 4 way complete all as specified and as directed. Make:- C&S/HPL/Legrand
Material and labour for Point wiring with 1.5 sqmm (Nominal area) sheathed FRLS multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non metallic rigid PVC casing caping of suitable size along with 1.5 sqmm sheathed FRLS multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof and including 1.6mm thick Modular terminal boxes covered with 3 mm thick laminated hylem sheet cover for mountling switches, socket, fan regulators etc complete for one light point controlled by one switch complete all as specified and as directed.Note: Make of PVC copper conductor cable:- Finolex/Poly cab/ Asian. Make of PVC casing capping : Modi's/Honeywell/ Prestoplast
Supply and fix Wiring for Circuit / Submain Wiring of FRLS cable size 2 x 1.5 sq.mm along with earth wire of size 1 x 1.5 sq.mm, Single Core, PVC insulated copper conductor (Fire Retardant) Cable in surface/recessed drawn through and including non metallic rigid PVC casing and capping complete all as specified and as directed. Make of Cable: Finolex/Anchor/Polycab Make of Casing & Capping: Modi's/Honeywell /Prestoplast
Supply and fix modular switch 1 way 6 amps ,240 volts, 1 module complete all as specified and as directed.Make: Legrand/Anchor (Roma)/ABB
Supply and fix modular white cover plate with frame 6 module type complete as specified and directed.Make: Legrand/Anchor (Roma)/ABB
Supply and Install Hi wall split Air Conditioner units Indoor, outdoor (Copper Condenser coil, Copper cooling coil and evaporator including required length of copper tubing and copper cables for connecting indoor and outdoor units) complete cordless remote control unit and with in-built ioniser and plasma filter for better indoor air quality with BEE 5 Star rating, Inverter type and stabilizer free operation of capacity 2 Ton ,year of manufacturing 2022 ,filled with Refrigerant gas R32/R410A complete all as specified and as directed. Make: O GENERAL/MITSUBISHI/ HITACHI Note : The rate quoted by the tenderer shall inclusive of the following provisions :- (i)PVC drain pipe not less than 20 mm dia from indoor unit (any floor) to upto ground level/ near to drain to be fixed with proper size base plate with clamps complete. (ii) Copper pipe 5/8" dia and 3/8" dia with 20SWG thickness refrigerant Piping with 19 mm(Suction line)&13 mm(Discharge line) thick Closed Cell rubber nitrile, Class "O"- arm-flex insulation and including connection complete up to 3 metre included in this item and beyond 3.00 mtr will be measured & paid separately under respective items . (iii) GI powder coated brackets of required size(Set of 2) including grouting with suitable size fastners
Supply and fix Copper pipe 5/8" dia 20SWG thickness with refrigerant Piping with 19 mm thick Closed Cell rubber nitrile, Class "O"- arm-flex insulation and including connection.
Supply and fixing of Copper pipe 3/8" dia 20SWG thickness with refrigerant Piping with 13 mm thick Closed Cell rubber nitrile, Class "O"- arm-flex insulation and including connection.
Material and labour for single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 V, 20 Amp complete all as specified and as directed . Make: Havells/Anchor/ABB
Supply and fix Wiring for Circuit / Submain Wiring of FRLS cable size 2 x 4.0 sq.mm along with earth wire of size 1 x 4.0 sq.mm, Single Core, PVC insulated copper conductor (Fire Retardant) Cable in surface/recessed drawn through and including non metallic rigid PVC casing and capping complete all as specified and as directed. Make of Cable: Finolex/Anchor/Polycab Make of Casing & Capping: Modi's/Honeywell /Prestoplast/MK electric
kvs constructions
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .