Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹10.8 L+₹47,354 (4.58%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹11.1 L+₹79,633 (7.71%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹11.7 L+₹1.3 L (13.0%)Rejected-Finance BHU | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹11.9 L+₹1.5 L (14.9%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹20.3 L
EMD Value
₹41,000
Closing Date
31 Jul 2020, 6:00 pmClosed
GE (AF) B/R Chakeri Kanpur
GE (AF) B/R Chakeri Kanpur
REWIRING OF CERTAIN BLDG INSIDE HOSPITAL AREA AND ALLIED WORKS AT 7 AF HOSPITAL KANPUR CANTT
2020_MES_355364_1
GE(AF)/CHK/T-06 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
272 days
AFH 07 Kanpur Cantt
Class E and cat b(i)
8 documents required · 8 mandatory
₹500
GE (AF) B/R Chakeri Kanpur
₹41,000
31 Aug 2020
24 Jun 2020
4 Aug 2020
24 Jun 2020
31 Jul 2020
13 Jul 2020
25 Jun 2020 - 4 Jul 2020
Amount
Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose, pendant holder, fitting and fixtures, MCB DB’s, MCB, Main switches, call bell etc and making good to disturbed surface to wall, floor etc to match with existing surface either by using same colour distemper or white colour wash all as required and directed by the Engr-in-Charge.
Taking down care fully by unscrewing from boards /out let boxes, fittings and fixtures such as Tube light fitting /of any type / MCB DB etc. Note : - This item to be operated only when item found serviceable for re –use in work complete all as specified and directed.
M&L for point wiring PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sq mm, 1100 V drawn in and including PVC casing and capping complete including cast iron/pressed steel terminal box 1.6 mm thick of required size Bakelite sheet 3mm thick for mounting switch, socket brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sq mm will be used as continuous earth wire for the following :-
One light /fan point controlled by one, one way switch complete all as specified and directed.
One 5/6 Amp socket on the same board with other switch complete all as specified and directed.
One 5/6 Amp socket on independent board complete all as specified and directed.
One 3 pin 15 Amp socket independent but with 2.5 Sq mm PVC insulated unsheathed copper stranded conductor and earth wire with 1.5 Sqmm complete all as specified and directed.
One bell point controlled by one, one way bell push button complete all as specified and directed.
All as per item No. 3.00 above but concealed drawn in and including non metallic PVC conduit medium grade for the following :-
One light/fan point controlled by one way switch complete all as specified and directed.
One 3 pin 5 Amp socket on the same board complete all as specified and directed.
One 3 pin 5 Amp socket on independent board complete all as specified and directed.
One 3 pin 15 Amp socket independent but with 2.5 sq mm PVC insulated unsheathed copper stranded conductor and 1.5 Sq mm size PVC insulated soild copper conductor as earth continuity conductor complete all as specified and directed.
One bell point controlled by one push bottom switch complete all as specified and directed.
Fixing only any type of Tube light fitting obtained from Item No. 2.00 Above Including making connection to ceiling rose/connector with copper flexible cable of size 1.5 sq mm complete all as specified and directed.
S & F switch piano type 240 V, 5 Amp, SP one way flush type complete all as specified and directed.
S & F bell push 240 V, 5 Amp, SP one way flush type complete all as specified and directed.
S&F socket outlet combination multipurpose 3 Pin 5 Amp, 240 volt and with 2 pin 5 Amp outlet also flush type including for existing points also (non shuttered) complete all as specified and directed.
S & F switch socket outlet combination 3 pin 15 Amp, 3 Pin 5 Amp outlet also flush type (non shuttered) including for existing points complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed.
S & F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed.
S & F for lamp holder metal cased body of brass with back plate with 5 Watt LED lamp complete all as specified and directed. Make: C&S Cat Part No LTHPLEDLAMP5W/B22 or equivalent in Crompton Greaves/Philips /Wipro/Bajaj
S & F sheet metal enclosure for MCB DB TPN double door, 4 way with 200 Amps rated Bus bar complete all as specified and directed.
S & F sheet metal enclosures for MCB distribution board TPN, 4 way double door type including with MCCB 4 Pole, 100 Amps, 16 KA fixed type as incomer with 200 Amp rated bus bar complete all as specified and directed.
S & F sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 Amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
All as per item No. 15.00 here-in-before but SPN 4 way 240 Volt complete all as specified and directed.
S & F Isolator TPN, 63 Amp 4 pole Isolator, 415 Volt complete all as specified in existing DB'S in replacement complete all as specified and directed.
S & F Isolator SPN, 63 Amp, 240 Volt complete all as specified and directed.
S&F MCB SP upto 30 Amp, 240 Volt complete all as specified and directed.
S&F MCCB 4 Pole 16KA 100 Amps fixed type complete all as specified and directed.
S&F Isolator SPN, 20 to 40 Amp, 240 Volt complete all as specified and directed.
M&L bell electric, 240 Volt, single pole complete all as specified and directed.
M&L regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete as specified
M& L for earthing complete with galvanized steel earth plate electrode 60cm x60 cm x6.0 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to earthing test point all as specified or indicated including testing on completion including PCC pit in (1:3:6) type C-2 cement concrete .RCC 1:2:4 Mix type B reinforced with 6mm dia MS bars @ 150mm RCC cover slab 40mm thick with two no’s fitting handle, GI pipe 20mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip 4 mm protection etc. complete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC rigid conduit 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 2.5 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly including taking out the old sub main wiring complete all as specified and directed. Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run complete all as specified.
All as per item No. 25.00 here in before but 6 Sqmm, 2 single core with PVC FRLS insulated, unsheathed stranded copper conduct cable of size 4 Sqmm as earth lead complete all as specified and directed.
M&L for sub main wiring with three runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC casing N Capping with all necessary fittings and accessories and 02xrun of PVC insulated and unsheathed single core cable multi stranded with copper conductor of size 4 Sqmm as continuous neutral and earth wire (green in colour) respectively, run through PVC casing N capping and connected to the terminal and common earth dolly complete all as specified and directed. (Note: Four run of cable and one run of PVC casing and capping and one run of earth continuity wire shall be measured as one run complete all as specified.)
M&L for replacement of unserviceable bulk head fitting of any type with LED bulk fitting with 6 watt LED complete connection with copper wire 23/0076 two core from ceiling rose to bulk head fitting complete all as specified and directed. Make C&S Model No. CG801B6WLED or equivalent model of Philips/Wipro/C&S.
S & F in replacement of existing bed light fitting with LED type surface mounted decorative bed light fitting 10 Watt LED complete with all accessories such as LED driver, LED bulb/rod and LED batten with cover etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as specified and directed. Make: Crompton Greaves Cat Part No LCL-10-CDL or equivalent of C&S/Philips/Wipro.
S&F in replacement fluorescent tube light fitting complete energy efficient T-8 LED batten and integrated type single tube 20 Watt, 4 ft long white complete with LED rod, LED driver and LED batten etc and all accessories pre wire and connecting up with copper three core flexible cord of min size 0.5 Sqmm and PVC connector etc including provision of hanging and wall mounting complete all as directed. Make: Crompton Greaves Cat Part No DMLN1LT8-16 and LTT8-20 or equivalent of C&S/Philips/Wipro/Havells.
M&L for replacement of existing unserviceable recessed mounted lumanaire with energy efficient 36 Watt LED type including making connection to ceiling rose with copper flexible wire of size 23/0076 complete all as specified and directed. Make Crompton Greaves model No. LCTLS-36-CDL or equivalent model of Philips/Wipro/ Havells/C&S.
S&F cirrus mini pro LED surface mounting luminaire with dimension of 312mm X 312mm suitable for porch complete all as specified and directed. Make: Philips Model No-SM200C LED16S 6500 PSU OD WH equivalent in Crompton/Bajaj
S & F in replacement of PVC insulated heavy duty electric unarmoured cable with solid aluminium conductor twin core 1100 Volts grade, cross sectional area 4 Sqmm complete all as specified and directed.
M&L for replacement of PVC laminated ISI marked top cover 3mm including cutting/drilling holes for mounting of switches, sockets, etc. as per site requirement suitable for following size of sunken /TW board :-
4"x4" size
7"x4" size
8"x6" size
8"x10" size
10"x12" size
S & F in replacement of modular switch 1 way 6 Amp, 1 module, 240 V flush type complete all as specified and directed.
S & F in replacement of modular switch 1 way 16 Amp, 1 module, 240 V flush type complete all as specified and directed.
S & F in replacement of modular bell push, flush type, 6 Amp, 1 module, 240 V complete all as specified and directed.
S & F in replacement of modular socket, 6A-2/3 pin combined, 2 module, 240 V complete all as specified and directed.
S & F in replacement of modular socket, 6 Amp / 16 Amp-2/3 pin combined, 2 module, 240 V complete all as specified and directed.
S & F in replacement of modular fan step regulator, 120 W, 2 module, 240 V complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 3 module complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 4 module complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 6 module complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 8 module complete all as specified and directed.
S & F in replacement of modular white cover plate with frame, 12 module complete all as specified and directed.
S & F in replacement of modular metal flush box, 3 module complete all as specified and directed.
S & F in replacement of modular metal flush box, 4 module complete all as specified and directed.
S & F in replacement of modular metal flush box, 6 module complete all as specified and directed.
S & F in replacement of modular metal flush box, 8 module complete all as specified and directed.
S & F in replacement of modular metal flush box, 12 module complete all as specified and directed.
S & F in replacement of electronic ballast for 28 Watt tube light complete all as specified and directed. Make: Crompton Greaves/Philip/Havells
M & L for replacement of lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S & F Isolator TPN, 100 Amp, 4 pole Isolator, 415 Volt complete all as specified in existing DB's in replacement complete all as specified and directed.
S & F in replacement MCB SP upto 30 Amp, 240 Volt complete all as specified and directed.
M & L bell electric, 240 Volt, single pole complete all as specified and directed.
M & L regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete all as specified and directed.
S & F in replacement of electronic ballast 2 x 36 Watt for ceiling light fitting complete all as specified and directed. Make : Bajaj/Crompton/Philips
S & F in replacement of LED integrated pattern T5, indoor decorative aluminium extruded LED fitting 20 watt, 4 feet complete including connection from ceiling rose to T5 LED light fitting with three core PVC flexible wire all as specified and directed . Make : Crompton Greaves/C&S/ Philips
S & F in replacement of flexible wire 23/0076 copper conductor from ceiling rose to fitting/fixture complete all as specified and directed.
M & L for smart integrated solar street light with inbuilt in mono crystalline panel, lithium ferro phosphate (LiFePo 4) battery, MPPT charge controller and PIR sensor with colour temperature 6000-6500k of 18 Watt all in one standard complete all as specified and directed. Make: Bajaj Sunsoko/Crompton/Philips
M & L for installation of new ceiling saving energy switch which contains sensitivity detector, integrated circuit it gathers automatism, convenience, safety, saving-energy and practicality functions. It works by receiving human motion infrared rays, when one enters the detection field, it can start the load at once and identify automatically day and night with the adjustable on the sun and moon position along with delay timing of minimum 10 sec 3 sec and maximum 8 min 2 min complete all as specified and directed. Make : Siemens/Philips/Crompton
S & F in replacement Metal clad single pole and a neutral enclosure with a two pin and earth plug and socket with one single pole MCB SP 20 Amp, 240 V complete all as specified and directed. Make- ABB/Havells/Crompton
S & F in replacement Metal clad triple pole and a neutral enclosure with a two pin and earth plug and socket with one single pole MCB TP 32 Amp, 240 V complete all as specified and directed. Make- ABB/Havells/Crompton
VEE KAY ENTERPRISES
SAKSHAM SUPPLIERS BUILDERS
Lalta Prasad vijay kumar Forwarding Agency
Preetpowercontrol
SAXENA BANDHU
S B ENTERPRISES
H S ENTERPRISES
SHYAM AND SONS ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .