Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance CHALIHA NAGAR DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Disqualified |
| 4 | Rejected-Technical | Rejected-Technical Disqualified |
Tender Value
Refer Docs
EMD Value
₹13.7 L
Closing Date
19 Jul 2023, 3:00 pmClosed
Associate Vice President (HCD)
HLL Lifecare Limited, HLL Bhavan, No26/4, Tambaram-Velachery Main Road, Pallikaranai, Chennai,Tamilnadu-600 100
Setting Up Pediatric Care Units at Various General Hospitals/District Hospitals in State of Arunachal Pradesh on Turnkey Basis
2023_HLL_159961_1
HLL/CMO/HCD/PS/GH-AP/23-24/02
Open Tender
Civil Works - Buildings
75 days
General Hospitals/District Hospitals in AP
Please refer Tender documents.
21 documents required · 21 mandatory
₹2,500
Yes
Payable To
₹13.7 L
Yes
HLL Lifecare Limited Chennai
7 Aug 2023
5 Jul 2023
20 Jul 2023
5 Jul 2023
19 Jul 2023
5 Jul 2023
5 Jul 2023 - 9 Jul 2023
10 Jul 2023
Amount
6 BEDDED PREFAB WARD
Patient Cot
Finger tip pulse oximeter
Oxygen Cylinder B Type with Flowmeter
4 BEDDED HDU
Otoscope
Ophthalmoscope
ECG Machine
Glucometer
ICU Beds
Emergency cart
C-pap/Bi-PAP
High flow nasal Cannula
Micro infusion Pump
Defibrillator
Portable suction
Portable ambu bags
T-Piece
Pediatric Laryngoscope (Curved &Stright Blades)
Nebulizer
Oxygen hood (Head box)
Oxygen portable) cyllinder (10 L)
Radiant warmer
Incubator
Procedure Light (Portable)
Multipara Monitor
Intra-Osseous needle
Pulse Oximeter
Thermometer
NIBP with all cuff sizes
Torch
Algorithms/Flow charts
X-ray view Box
Printed drug dosages for children
Patient stretcher and wheel chair
Measuring Tape
Phototherapy
Bedside Table
Over bed table
IV Pole
Bed side Chair
Infant/Neonatal weighing machine(6)
Stethoscope
Table and chair for staff
Almirah
Needle cutter
Refrigerator
Medical gas pipeline system(Oxygen)
2 BEDDED PEDIATRIC ICU
Portable EEG
Otoscope
Ophthalmoscope
Portable X-Ray
12 Lead Portable ECG
Blood Gas Machine
Glucometer
ICU Beds
Emergency Cart
Ventilator Invasive
High Flow Nasal Cannula
Micro - Infusion Pumps
Defibrillator
Portable Suction
Pediatric Ambu Bags
T-Piece
Pediatric Laryngoscope(Curved & Straight Blades
Fiber optic Bronchoscope
Nebulizer
Oxygen Hood(Head Box)
Oxygen (Portable) Cylinder (10 L)
Incubator
Procedure Light(Portable)
Multi-Para Monitor
Intra-Osseous needle
Pulse Oximeter
Thermometer
NIBP with all cuff sizes
Torch
Algorithms/Flow charts
X-Ray view Box
Printed drug dosages for children
Patient Stretcher and wheel chair
Measuring Tape
Phototherapy
Bedside Table
Over Bed Table
IV Pole
Bedside Chair
Infant/Neonatal Weighing Machine (6)
Stethoscope
Table and chair for staff
Almirah
Needle Cutter
Refrigerator
Medical gas pipeline system(Oxygen)
Description of Work / Item(s)
Amount
6 BEDDED PREFAB WARD
Patient Cot
Finger tip pulse oximeter
Oxygen Cylinder B Type with Flowmeter
4 BEDDED HDU
Otoscope
Ophthalmoscope
ECG Machine
Glucometer
ICU Beds
Emergency cart
C-pap/Bi-PAP
High flow nasal Cannula
Micro infusion Pump
Defibrillator
Portable suction
Portable ambu bags
T-Piece
Pediatric Laryngoscope (Curved &Stright Blades)
Nebulizer
Oxygen hood (Head box)
Oxygen portable) cyllinder (10 L)
Radiant warmer
Incubator
Procedure Light (Portable)
Multipara Monitor
Intra-Osseous needle
Pulse Oximeter
Thermometer
NIBP with all cuff sizes
Torch
Algorithms/Flow charts
X-ray view Box
Printed drug dosages for children
Patient stretcher and wheel chair
Measuring Tape
Phototherapy
Bedside Table
Over bed table
IV Pole
Bed side Chair
Infant/Neonatal weighing machine(6)
Stethoscope
Table and chair for staff
Almirah
Needle cutter
Refrigerator
Medical gas pipeline system(Oxygen)
2 BEDDED PEDIATRIC ICU
Portable EEG
Otoscope
Ophthalmoscope
Portable X-Ray
12 Lead Portable ECG
Blood Gas Machine
Glucometer
ICU Beds
Emergency Cart
Ventilator Invasive
High Flow Nasal Cannula
Micro - Infusion Pumps
Defibrillator
Portable Suction
Pediatric Ambu Bags
T-Piece
Pediatric Laryngoscope(Curved & Straight Blades
Fiber optic Bronchoscope
Nebulizer
Oxygen Hood(Head Box)
Oxygen (Portable) Cylinder (10 L)
Incubator
Procedure Light(Portable)
Multi-Para Monitor
Intra-Osseous needle
Pulse Oximeter
Thermometer
NIBP with all cuff sizes
Torch
Algorithms/Flow charts
X-Ray view Box
Printed drug dosages for children
Patient Stretcher and wheel chair
Measuring Tape
Phototherapy
Bedside Table
Over Bed Table
IV Pole
Bedside Chair
Infant/Neonatal Weighing Machine (6)
Stethoscope
Table and chair for staff
Almirah
Needle Cutter
Refrigerator
Medical gas pipeline system(Oxygen)
Description of Work / Item(s)
Amount
5 BEDDED ICU
ICU Cot
Bedside Locker
Over Bed Table
Foot Step - Double
Bed Side Stool
Biomedical Waste Bins (set of 3)
Multipara Monitor
ICU Ventillator
Syringe Pump
Infusion Pump
Laryngoscope
Thermometer-Infrared
Ambu Bag -Adult
ECG Machine-12 Channel
Biphasic Defibrillator
Electronic Weighing Scale - Adult
Patient Warming System
Suction Apparatus - Electrical
Patient Stretcher-Fully SS
Wheel Chair-Foldable
Crash Cart
Dressing Trolley
Drug Trolley/Medicine Cart
ECG Machine Trolley
Instrument Trolley
Oxygen cylinder Trolley
Glucometer
Stethoscope
Medical gas pipeline system(Oxygen)
1 BEDDED PEDIATRIC ICU
Otoscope
Ophthalmoscope
12 Lead Portable ECG
Blood Gas Machine
Glucometer
ICU Beds
Emergency Cart
Ventilator Invasive
High Flow Nasal Cannula
Micro - Infusion Pumps
Defibrillator
Portable Suction
Pediatric Ambu Bags
T-Piece
Pediatric Laryngoscope(Curved & Straight Blades
Nebulizer
Oxygen Hood(Head Box)
Oxygen (Portable) Cylinder (10 L)
Radiant Warmer
Incubator
Procedure Light(Portable)
Multi-Para Monitor
Intra-Osseous needle
Pulse Oximeter
Thermometer
NIBP with all cuff sizes
Torch
Algorithms/Flow charts
X-Ray view Box
Printed drug dosages for children
Patient Stretcher and wheel chair
Measuring Tape
Phototherapy
Bedside Table
Over Bed Table
IV Pole
Bedside Chair
Infant/Neonatal Weighing Machine (6)
Stethoscope
Table and chair for staff
Almirah
Needle Cutter
Refrigerator
Medical gas pipeline system(O2)
Description of Work / Item(s)
Amount
6 BEDDED PREFAB WARD
Patient Cot
Finger tip pulse oximeter
Oxygen Cylinder B Type with Flowmeter
4 BEDDED HDU
Otoscope
Ophthalmoscope
ECG Machine
Glucometer
ICU Beds
Emergency cart
C-pap/Bi-PAP
High flow nasal Cannula
Micro infusion Pump
Defibrillator
Portable suction
Portable ambu bags
T-Piece
Pediatric Laryngoscope (Curved &Stright Blades)
Nebulizer
Oxygen hood (Head box)
Oxygen portable) cyllinder (10 L)
Radiant warmer
Incubator
Procedure Light (Portable)
Multipara Monitor
Intra-Osseous needle
Pulse Oximeter
Thermometer
NIBP with all cuff sizes
Torch
Algorithms/Flow charts
X-ray view Box
Printed drug dosages for children
Patient stretcher and wheel chair
Measuring Tape
Phototherapy
Bedside Table
Over bed table
IV Pole
Bed side Chair
Infant/Neonatal weighing machine(6)
Stethoscope
Table and chair for staff
Almirah
Needle cutter
Refrigerator
Medical gas pipeline system(Oxygen)
2 BEDDED PEDIATRIC ICU
Portable EEG
Otoscope
Ophthalmoscope
Portable X-Ray
12 Lead Portable ECG
Blood Gas Machine
Glucometer
ICU Beds
Emergency Cart
Ventilator Invasive
High Flow Nasal Cannula
Micro - Infusion Pumps
Defibrillator
Portable Suction
Pediatric Ambu Bags
T-Piece
Pediatric Laryngoscope(Curved & Straight Blades
Fiber optic Bronchoscope
Nebulizer
Oxygen Hood(Head Box)
Oxygen (Portable) Cylinder (10 L)
Incubator
Procedure Light(Portable)
Multi-Para Monitor
Intra-Osseous needle
Pulse Oximeter
Thermometer
NIBP with all cuff sizes
Torch
Algorithms/Flow charts
X-Ray view Box
Printed drug dosages for children
Patient Stretcher and wheel chair
Measuring Tape
Phototherapy
Bedside Table
Over Bed Table
IV Pole
Bedside Chair
Infant/Neonatal Weighing Machine (6)
Stethoscope
Table and chair for staff
Almirah
Needle Cutter
Refrigerator
Medical gas pipeline system(Oxygen)
5 BEDDED ICU
ICU Cot
Bedside Locker
Over Bed Table
Foot Step - Double
Bed Side Stool
Biomedical Waste Bins (set of 3)
Multipara Monitor
ICU Ventillator
Syringe Pump
Infusion Pump
Laryngoscope
Thermometer-Infrared
Ambu Bag -Adult
ECG Machine-12 Channel
Biphasic Defibrillator
Electronic Weighing Scale - Adult
Patient Warming System
Suction Apparatus - Electrical
Patient Stretcher-Fully SS
Wheel Chair-Foldable
Crash Cart
Dressing Trolley
Drug Trolley/Medicine Cart
ECG Machine Trolley
Instrument Trolley
Oxygen cylinder Trolley
Glucometer
Stethoscope
Medical gas pipeline system(Oxygen)
1 BEDDED PEDIATRIC ICU
Portable EEG
Otoscope
Ophthalmoscope
12 Lead Portable ECG
Blood Gas Machine
Glucometer
ICU Beds
Emergency Cart
Ventilator Invasive
High Flow Nasal Cannula
Micro - Infusion Pumps
Defibrillator
Portable Suction
Pediatric Ambu Bags
T-Piece
Pediatric Laryngoscope(Curved & Straight Blades
Nebulizer
Oxygen Hood(Head Box)
Oxygen (Portable) Cylinder (10 L)
Radiant Warmer
Incubator
Procedure Light(Portable)
Multi-Para Monitor
Intra-Osseous needle
Pulse Oximeter
Thermometer
NIBP with all cuff sizes
Torch
Algorithms/Flow charts
X-Ray view Box
Printed drug dosages for children
Patient Stretcher and wheel chair
Measuring Tape
Phototherapy
Bedside Table
Over Bed Table
IV Pole
Bedside Chair
Infant/Neonatal Weighing Machine (6)
Stethoscope
Table and chair for staff
Almirah
Needle Cutter
Refrigerator
Medical gas pipeline system(Oxygen)
Description of Work / Item(s)
Amount
Civil Work
Demolishing brick work in Cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling tile work/Mossaic work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Demolishing cement concrete/ Lime concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge: Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge including cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including scaffolding & disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness not less than 5.5 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm:
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles 300x450 mm size conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge Extruded section profile size 48x40 mm
Providing and Fixing 30 mm thick factory made Polyvinyl Chloride (UPVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium/uPVC door, shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with SS screws etc .complete as per directionof Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) Transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stonework by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing Perforated gypsum board tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30mm thick minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm
Providing and Fixing 12.5 mm thick square edge PVC Laminated GypsumTile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part Iand laminated with white 0.16mm thick fire retardantPVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wrapsthe edges and is bonded to the edges and the backside metalized polyester
Prepare surfaces and plaster with CM 1:3 (1 cement: 3 fine sand) ,12mm minimum thick to all interior faces of walls (sponge finish) including RCC surfaces not contiguous to masonry.Necessary internal grooves of size 10mmx10mm shall be carried out as shown/directed by engineer-in-charge.
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Providing and fixing gun metal gate valve with C.I. wheel of approved quality -25MM
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc 20 mm nominal outer dia .Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc 32 mm nominal outer dia Pipes
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms.
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :15mm nominal bore
Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 48" x 18". Complete as per the per the direction of Engineer in charge.
Providing & Fixing of Column Corner Beeds, which is made by Continuous Retainer covered by PVC width of 75mm using self tapping screws etc., in the column corner & also Wall corners from floor to height of 1.2M as per the instruction of Engineer in charge.
Providing & fixing of Trolley Guard which is fixed by using continuous Aluminium ratainer 2mm thick covered by vinyl guard (200mm width) with the help of sheet metal screws with Alligator Anchor at a height of 1200 mm as per the instruction of Engineer in charge.
Design, providing and fixing Digital Printed vinyl sheets as per the per the direction of Engineer in charge.
Providing and fixing IV Track Hospital Cubicle Track System, which includes VX Track, Over and L Shape Bends, Stain Retardant Netted Curtains, Direct Ceiling Fixing accessories. As per the instruction of Engineer in charge.
ELECTRICAL WORKS FOR 4 BED HDU+2 BED ICU WARD
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X4 sq.mm + 1X4 sq.mm earth wire
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make)20 mm
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6pin 15/16 Amps (universal) socket outlet
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
ITC Fluroscent fittings: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)6 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
LT CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying and fixing following rating, Double pole, (three phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.32 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing 40A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.(VDB outgoings)
SUPPLY OF LT CABLES
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 2 X 10 sq. mm
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3½ X 35 sq. mm
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 16 sq. mm
LIGHT FITTINGS & FANS
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of recess/surface mounted, CRCA with powder coated housing, frosted PMMA / PC diffuser, 33-36W LED light fixture (2x2 feet), p.f 0.9, THD < 10%, 3.0kV surge protection, CCT 6500K, Efficacy 80 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 20-24 W LED light fixture (4 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted 10 W LED light fixture (2 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply and installation of 300 mm sweep, 1325 - 1380 rpm, plastic blade & bird guard, exhaust fan complete with all required accessories including mounting accessories.
FIRE DETECTION & ALARM SYSTEM
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required(other areas & above ceiling)
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 2/4 ZONE
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply and fixing of 4Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 15683, external epoxy powder coating with PO Red Shade, Supplied with standard accessories.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a)1 or 2 Module (75mmX75mm)
Supply, Laying, Testing & Commissioning of CAT6 (RJ-45) I/O Ports
Supply, Laying, Testing & Commissioning of 1U CAT6 Patch Panel
Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 1 Meter
Supply,Installation,Testing & Commissioning of CAT6 Patch Cord with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter
Supply, Installation, Testing & Commissioning of 16 Port Network Switch with 16 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink
Supply, Installation, Testing & Commissioning of 6U Network Rack with below specifications as minimum and all the necessary accessories - Height - 6U - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels
TELEPHONE CONNECTION
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and Drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 PAIR
Supply , Installation of PBX System with below features and accessories - 1 P&T Line in - Extensions - 8 ( Analog )
Supply of User Phone- Analog phone
ELECTRICAL WORKS FOR 6 BED WARD
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X4 sq.mm + 1X4 sq.mm earth wire
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make)20 mm
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6pin 15/16 Amps (universal) socket outlet
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
ITC Ceiling fan: Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
ITC Fluroscent fittings: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)6 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
LT CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required4 X 10 sq. mm (25mm)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
SUPPLY OF LT CABLES
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 10 sq. mm
Supplying and fixing of metalic 415 V, 63A Copper Busbar distribution chamber with its all accessories.
LIGHT FITTINGS & FANS
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 20-24 W LED light fixture (4 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted 10 W LED light fixture (2 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of ceiling fan 1200 mm sweep, 230V, 1Ph, 5 star rated complete with double ball bearing, motor blades, down rods, canopy, capacitor etc complete as required.
FIRE DETECTION & ALARM SYSTEM
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required(other areas & above ceiling)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply and fixing of 4Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 15683, external epoxy powder coating with PO Red Shade, Supplied with standard accessories.
Negative pressure System
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
SITC of Canvas Connection for Exhaust fan
Supply installation testing and commisioning of Insulated inline Circular/ Cabinet fan of following cfm & staticCabinet Fan (For Negative Pressure)1500 CFM @ 25 mm wg
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a)1 or 2 Module (75mmX75mm)
Supply, Laying, Testing & Commissioning of CAT6 (RJ-45) I/O Ports
Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 1 Meter
Supply,Installation,Testing & Commissioning of CAT6 Patch Cord with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter
TELEPHONE CONNECTION
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and Drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 PAIR
Supply of User Phone- Analog phone
Description of Work / Item(s)
Amount
Civil Work
Demolishing brick work in Cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling tile work/Mossaic work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Demolishing cement concrete/ Lime concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge: Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge including cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including scaffolding & disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
Making the opening in brick masonry For door/ window/ clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:cement mortar 1:4 (1 cement : 4 coarse sand)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness not less than 5.5 mm
Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, flooring, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade: Area of slab over 0.50 sqm.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm:
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles 300x450 mm size conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge Extruded section profile size 48x40 mm
Providing and Fixing 30 mm thick factory made Polyvinyl Chloride (UPVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium/uPVC door, shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with SS screws etc .complete as per directionof Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) Transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stonework by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing Perforated gypsum board tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30mm thick minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm
Providing and Fixing 12.5 mm thick square edge PVC Laminated GypsumTile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part Iand laminated with white 0.16mm thick fire retardantPVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wrapsthe edges and is bonded to the edges and the backside metalized polyester
Prepare surfaces and plaster with CM 1:3 (1 cement: 3 fine sand) ,12mm minimum thick to all interior faces of walls (sponge finish) including RCC surfaces not contiguous to masonry.Necessary internal grooves of size 10mmx10mm shall be carried out as shown/directed by engineer-in-charge.
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Providing and fixing gun metal gate valve with C.I. wheel of approved quality -25MM
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc 20 mm nominal outer dia .Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc 32 mm nominal outer dia Pipes
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms.
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :15mm nominal bore
Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 48" x 18". Complete as per the per the direction of Engineer in charge.
Providing & Fixing of Column Corner Beeds, which is made by Continuous Retainer covered by PVC width of 75mm using self tapping screws etc., in the column corner & also Wall corners from floor to height of 1.2M as per the instruction of Engineer in charge.
Providing & fixing of Trolley Guard which is fixed by using continuous Aluminium ratainer 2mm thick covered by vinyl guard (200mm width) with the help of sheet metal screws with Alligator Anchor at a height of 1200 mm as per the instruction of Engineer in charge.
Design, providing and fixing Digital Printed vinyl sheets as per the per the direction of Engineer in charge.
Providing and fixing IV Track Hospital Cubicle Track System, which includes VX Track, Over and L Shape Bends, Stain Retardant Netted Curtains, Direct Ceiling Fixing accessories. As per the instruction of Engineer in charge.
ELECTRICAL WORKS FOR 4 BED HDU+2 BED ICU WARD
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X4 sq.mm + 1X4 sq.mm earth wire
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make)20 mm
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6pin 15/16 Amps (universal) socket outlet
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
ITC Fluroscent fittings: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required40 A
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as requiredUpto 35 sq. mm (clamped with 1mm thick saddle)
LT CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying and fixing following rating, Double pole, (three phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required32 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing 40A/63A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.(VDB outgoings)
SUPPLY OF LT CABLES
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date2 X 10 sq. mm
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date3½ X 35 sq. mm
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date4 X 16 sq. mm
LIGHT FITTINGS & FANS
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of recess/surface mounted, CRCA with powder coated housing, frosted PMMA / PC diffuser, 33-36W LED light fixture (2x2 feet), p.f 0.9, THD < 10%, 3.0kV surge protection, CCT 6500K, Efficacy 80 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 20-24 W LED light fixture (4 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted 10 W LED light fixture (2 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply and installation of 300 mm sweep, 1325 - 1380 rpm, plastic blade & bird guard, exhaust fan complete with all required accessories including mounting accessories.
SPLIT AC
Supply, installation, testing and commissioning of 1 TR,Hot and Cold 5 star rated (as per BEE) Air Cooled High Wall mounted Inverter type Split Air Conditioner consisting of high wall mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of enegy efficient suitable rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 4m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required.Make: Voltas, Toshiba, Blue Star, Carrier,Daikin,Hitachi or equivalent or as per the approval of Engineer in Charge
Supply, installation, testing and commissioning of 1.5 TR,Hot and Cold 5 star rated (as per BEE) Air Cooled High Wall mounted Inverter type Split Air Conditioner consisting of high wall mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of enegy efficient suitable rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 4m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required.Make: Voltas, Toshiba, Blue Star, Carrier,Daikin,Hitachi or equivalent or as per the approval of Engineer in Charge
FIRE DETECTION & ALARM SYSTEM
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required(other areas & above ceiling)
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 2/4 ZONE
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply and fixing of 4Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 15683, external epoxy powder coating with PO Red Shade, Supplied with standard accessories.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a)1 or 2 Module (75mmX75mm)
Supply, Laying, Testing & Commissioning of CAT6 (RJ-45) I/O Ports
Supply, Laying, Testing & Commissioning of 1U CAT6 Patch Panel
Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 1 Meter
Supply,Installation,Testing & Commissioning of CAT6 Patch Cord with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter
Supply, Installation, Testing & Commissioning of 16 Port Network Switch with 16 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink
Supply, Installation, Testing & Commissioning of 6U Network Rack with below specifications as minimum and all the necessary accessories - Height - 6U - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels
TELEPHONE CONNECTION
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and Drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 PAIR
Supply , Installation of PBX System with below features and accessories - 1 P&T Line in - Extensions - 8 ( Analog )
Supply of User Phone- Analog phone
ELECTRICAL WORKS FOR 6 BED WARD
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as requiredGroup C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X4 sq.mm + 1X4 sq.mm earth wire
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make)20 mm
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.6pin 15/16 Amps (universal) socket outlet
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
ITC Ceiling fan: Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
ITC Fluroscent fittings: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)6 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
LT CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
SUPPLY OF LT CABLES
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 10 sq. mm
Supplying and fixing of metalic 415 V, 63A Copper Busbar distribution chamber with its all accessories.
LIGHT FITTINGS & FANS
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 20-24 W LED light fixture (4 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted 10 W LED light fixture (2 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of ceiling fan 1200 mm sweep, 230V, 1Ph, 5 star rated complete with double ball bearing, motor blades, down rods, canopy, capacitor etc complete as required.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply and installation of 300 mm sweep, 1325 - 1380 rpm, plastic blade & bird guard, exhaust fan complete with all required accessories including mounting accessories.
FIRE DETECTION & ALARM SYSTEM
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required(other areas & above ceiling)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply and fixing of 4Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 15683, external epoxy powder coating with PO Red Shade, Supplied with standard accessories.
Negative pressure System
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
SITC of Canvas Connection for Exhaust fan
Supply installation testing and commisioning of Insulated inline Circular/ Cabinet fan of following cfm & staticCabinet Fans (For Negative Pressure)1500 CFM @ 25 mm wg
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a)1 or 2 Module (75mmX75mm)
Supply, Laying, Testing & Commissioning of CAT6 (RJ-45) I/O Ports
Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 1 Meter
Supply,Installation,Testing & Commissioning of CAT6 Patch Cord with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter
TELEPHONE CONNECTION
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and Drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 PAIR
Supply of User Phone- Analog phone
Description of Work / Item(s)
Amount
Civil Work
Dismantling tile work/Mossaic work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Demolishing cement concrete/ Lime concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge: Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge including cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including scaffolding & disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:cement mortar 1:4 (1 cement : 4 coarse sand)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness not less than 5.5 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm:
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles 300x450 mm size conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge Extruded section profile size 48x40 mm
Providing and Fixing 30 mm thick factory made Polyvinyl Chloride (UPVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium/uPVC door, shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with SS screws etc .complete as per directionof Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) Transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stonework by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing Perforated gypsum board tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30mm thick minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm
Providing and Fixing 12.5 mm thick square edge PVC Laminated GypsumTile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part Iand laminated with white 0.16mm thick fire retardantPVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wrapsthe edges and is bonded to the edges and the backside metalized polyester
Prepare surfaces and plaster with CM 1:3 (1 cement: 3 fine sand) ,12mm minimum thick to all interior faces of walls (sponge finish) including RCC surfaces not contiguous to masonry.Necessary internal grooves of size 10mmx10mm shall be carried out as shown/directed by engineer-in-charge.
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Providing and fixing gun metal gate valve with C.I. wheel of approved quality -25MM
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc 20 mm nominal outer dia .Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc 32 mm nominal outer dia Pipes
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms.
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :15mm nominal bore
Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 48" x 18". Complete as per the per the direction of Engineer in charge.
Providing & Fixing of Column Corner Beeds, which is made by Continuous Retainer covered by PVC width of 75mm using self tapping screws etc., in the column corner & also Wall corners from floor to height of 1.2M as per the instruction of Engineer in charge.
Providing & fixing of Trolley Guard which is fixed by using continuous Aluminium ratainer 2mm thick covered by vinyl guard (200mm width) with the help of sheet metal screws with Alligator Anchor at a height of 1200 mm as per the instruction of Engineer in charge.
Design, providing and fixing Digital Printed vinyl sheets as per the per the direction of Engineer in charge.
Providing and fixing IV Track Hospital Cubicle Track System, which includes VX Track, Over and L Shape Bends, Stain Retardant Netted Curtains, Direct Ceiling Fixing accessories. As per the instruction of Engineer in charge.
ELECTRICAL WORKS FOR 5 BED ICU+1BED PICU
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X4 sq.mm + 1X4 sq.mm earth wire
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make)20 mm
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6pin 15/16 Amps (universal) socket outlet
ITC Fluroscent fittings: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 4 way (4 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
LT CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying and fixing following rating, Double pole, (three phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.32 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing 40A/63A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.(VDB outgoings)
SUPPLY OF LT CABLES
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 2 X 10 sq. mm
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3½ X 35 sq. mm
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 16 sq. mm
LIGHT FITTINGS & FANS
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of recess/surface mounted, CRCA with powder coated housing, frosted PMMA / PC diffuser, 33-36W LED light fixture (2x2 feet), p.f 0.9, THD < 10%, 3.0kV surge protection, CCT 6500K, Efficacy 80 Lm/W, CRI 80 etc with all required accessories.
Description of Work / Item(s)
Amount
Civil Work
Demolishing brick work in Cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Dismantling tile work/Mossaic work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
Demolishing cement concrete/ Lime concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge: Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge including cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including scaffolding & disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in:cement mortar 1:4 (1 cement : 4 coarse sand)
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of thickness not less than 5.5 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm:
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles 300x450 mm size conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge Extruded section profile size 48x40 mm
Providing and Fixing 30 mm thick factory made Polyvinyl Chloride (UPVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium/uPVC door, shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With brass cover plate minimum 1.25 mm thickness.
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with SS screws etc .complete as per directionof Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) Transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stonework by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing Perforated gypsum board tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30mm thick minimum) sheet, 1200mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm
Providing and Fixing 12.5 mm thick square edge PVC Laminated GypsumTile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part Iand laminated with white 0.16mm thick fire retardantPVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wrapsthe edges and is bonded to the edges and the backside metalized polyester
Prepare surfaces and plaster with CM 1:3 (1 cement: 3 fine sand) ,12mm minimum thick to all interior faces of walls (sponge finish) including RCC surfaces not contiguous to masonry.Necessary internal grooves of size 10mmx10mm shall be carried out as shown/directed by engineer-in-charge.
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
Providing and fixing gun metal gate valve with C.I. wheel of approved quality -25MM
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from the centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
Providing and fixing uplasticised PVC connection pipe with brass unions:45 cm length15 mm nominal bore
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Flexible pipe32 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc 20 mm nominal outer dia .Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc 32 mm nominal outer dia Pipes
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms.
Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour. weighing not less than 105 gms.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10 Kgf/cm2- External work - Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 :15mm nominal bore
Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs of Size 48" x 18". Complete as per the per the direction of Engineer in charge.
Providing & Fixing of Column Corner Beeds, which is made by Continuous Retainer covered by PVC width of 75mm using self tapping screws etc., in the column corner & also Wall corners from floor to height of 1.2M as per the instruction of Engineer in charge.
Providing & fixing of Trolley Guard which is fixed by using continuous Aluminium ratainer 2mm thick covered by vinyl guard (200mm width) with the help of sheet metal screws with Alligator Anchor at a height of 1200 mm as per the instruction of Engineer in charge.
Design, providing and fixing Digital Printed vinyl sheets as per the per the direction of Engineer in charge.
Providing and fixing IV Track Hospital Cubicle Track System, which includes VX Track, Over and L Shape Bends, Stain Retardant Netted Curtains, Direct Ceiling Fixing accessories. As per the instruction of Engineer in charge.
ELECTRICAL WORKS FOR 4 BED HDU+3 PICU +5 ICU
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as require2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as require2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as require2X4 sq.mm + 1X4 sq.mm earth wire
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make)20 mm
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6pin 15/16 Amps (universal) socket outlet
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
ITC Fluroscent fittings: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
LT CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 10 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
Supplying and fixing following rating, Double pole, (three phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.32 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing 40A/63A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.(VDB outgoings)
SUPPLY OF LT CABLES
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 2 X 10 sq. mm
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 3½ X 35 sq. mm
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 16 sq. mm
LIGHT FITTINGS & FANS
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of recess/surface mounted, CRCA with powder coated housing, frosted PMMA / PC diffuser, 33-36W LED light fixture (2x2 feet), p.f 0.9, THD < 10%, 3.0kV surge protection, CCT 6500K, Efficacy 80 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 20-24 W LED light fixture (4 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted 10 W LED light fixture (2 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of recess mounted downlight fixture, die cast aluminium with powder coated housing, frosted PMMA / PC diffuser, 15-18W LED light fixture, p.f 0.9, THD < 20%, 2.5kV surge protection, CCT 6500K, Efficacy 75 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply and installation of 300 mm sweep, 1325 - 1380 rpm, plastic blade & bird guard, exhaust fan complete with all required accessories including mounting accessories.
SPLIT AC
Supply, installation, testing and commissioning of 1.5 TR,Hot and Cold 5 star rated (as per BEE) Air Cooled High Wall mounted Inverter type Split Air Conditioner consisting of high wall mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of enegy efficient suitable rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 4m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required.Make: Voltas, Toshiba, Blue Star, Carrier,Daikin,Hitachi or equivalent or as per the approval of Engineer in Charge
FIRE DETECTION & ALARM SYSTEM
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required(other areas & above ceiling)
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 2/4 ZONE
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply and fixing of 4Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 15683, external epoxy powder coating with PO Red Shade, Supplied with standard accessories.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a)1 or 2 Module (75mmX75mm)
Supply, Laying, Testing & Commissioning of CAT6 (RJ-45) I/O Ports
Supply, Laying, Testing & Commissioning of 1U CAT6 Patch Panel
Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 1 Meter
Supply,Installation,Testing & Commissioning of CAT6 Patch Cord with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter
Supply, Installation, Testing & Commissioning of 16 Port Network Switch with 16 No's of 10/100/1000 ports and 2 Gigabit Copper/ SFP Combo ports for uplink
Supply, Installation, Testing & Commissioning of 6U Network Rack with below specifications as minimum and all the necessary accessories - Height - 6U - Mounting Hardware Kit (1 lot) - Tray - Front glass doors and back steel door and side panels
TELEPHONE CONNECTION
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and Drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 PAIR
Supply , Installation of PBX System with below features and accessories - 1 P&T Line in - Extensions - 8 ( Analog )
Supply of User Phone- Analog phone
ELECTRICAL WORKS FOR 6 BED WARD
Point wiring in PVC conduit with modular type switch.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Wiring through PVC conduit
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X1.5 sq.mm + 1X1.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X2.5 sq.mm + 1 X2.5 sq mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.2X4 sq.mm + 1X4 sq.mm earth wire
S/F PVC conduit:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(ISI Make)20 mm
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Modular type blanking plate:
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Modular boxes, bases & cover plate:
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.3 module
Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required.6 module
Modular type switch/socket:
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 Amp socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 15/16 Amps switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 6pin 15/16 Amps (universal) socket outlet
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
ITC Ceiling fan: Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
ITC Fluroscent fittings: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)6 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earthelectrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
CABLE LAYING
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
LT CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 100mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
SUPPLY OF LT CABLES
Supply of the following size 1.1kV grade XLPE insulated PVC sheathed, armoured Aluminium conductor power cable confirming to IS 7098 (part 1) ammended upto date. 4 X 10 sq. mm
Supplying and fixing of metalic 415 V, 63A Copper Busbar distribution chamber with its all accessories.
LIGHT FITTINGS & FANS
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted, extruded aluminium with powder coated housing, frosted PMMA / PC diffuser, 20-24 W LED light fixture (4 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of surface mounted 10 W LED light fixture (2 feet), p.f 0.9, THD < 15%, 2.5kV surge protection, CCT 6500K, Efficacy 100 Lm/W, CRI 80 etc with all required accessories.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply of ceiling fan 1200 mm sweep, 230V, 1Ph, 5 star rated complete with double ball bearing, motor blades, down rods, canopy, capacitor etc complete as required.
Supply of following surface/ recess mounting type LED light fittings complete with all accessories and lamp etc. directly on the ceiling/wall ( All ceiling mounted fittings shall be fixed with 2 Nos anchor fasteners. (Extra chain shall be provided for suspension of recess fittings) including connections using 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as required.Supply and installation of 300 mm sweep, 1325 - 1380 rpm, plastic blade & bird guard, exhaust fan complete with all required accessories including mounting accessories.
FIRE DETECTION & ALARM SYSTEM
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required(other areas & above ceiling)
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply and fixing of 4Kg ABC Dry Powder (Stored Pressure) Type Fire Extinguisher. pressurized with dry nitrogen gas at 15 bar. Design, construction and testing as per IS 15683, external epoxy powder coating with PO Red Shade, Supplied with standard accessories.
Negative pressure System
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.63 mm sheet
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
SITC of Canvas Connection for Exhaust fan
Supply installation testing and commisioning of Insulated inline Circular/ Cabinet fan of following cfm & staticCabinet Fan (For Negative Pressure)2000 CFM @ 25 mm wg
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.a)1 or 2 Module (75mmX75mm)
Supply, Laying, Testing & Commissioning of CAT6 (RJ-45) I/O Ports
Supply,Installation,Testing &Commissioning of CAT6 Patch Cord with Moulded boots Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable.- 1 Meter
Supply,Installation,Testing & Commissioning of CAT6 Patch Cord with Moulded boots, Over-moulded boot at each end provide strain relief and maintains minimum bend radius of the cable - 2 Meter
TELEPHONE CONNECTION
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
Supplying and Drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.4 PAIR
Supply of User Phone- Analog phone
Description of Work / Item(s)
Amount
ECG Machine
2nd Year
3rd Year
4th Year
5th Year
6th Year
ICU Beds
2nd Year
3rd Year
4th Year
5th Year
6th Year
C-pap/Bi-PAP
2nd Year
3rd Year
4th Year
5th Year
6th Year
High flow nasal Cannula
2nd Year
3rd Year
4th Year
5th Year
6th Year
Micro infusion Pump
2nd Year
3rd Year
4th Year
5th Year
6th Year
Defibrillator
2nd Year
3rd Year
4th Year
5th Year
6th Year
Portable suction
2nd Year
3rd Year
4th Year
5th Year
6th Year
Radiant warmer
2nd Year
3rd Year
4th Year
5th Year
6th Year
Incubator
2nd Year
3rd Year
4th Year
5th Year
6th Year
Procedure Light (Portable)
2nd Year
3rd Year
4th Year
5th Year
6th Year
Multipara Monitor
2nd Year
3rd Year
4th Year
5th Year
6th Year
Pulse Oximeter
2nd Year
3rd Year
4th Year
5th Year
6th Year
Phototherapy
2nd Year
3rd Year
4th Year
5th Year
6th Year
Refrigerator
2nd Year
3rd Year
4th Year
5th Year
6th Year
Portable EEG
2nd Year
3rd Year
4th Year
5th Year
6th Year
Portable X-Ray
2nd Year
3rd Year
4th Year
5th Year
6th Year
ECG Machine
2nd Year
3rd Year
4th Year
5th Year
6th Year
Blood Gas Machine
2nd Year
3rd Year
4th Year
5th Year
6th Year
ICU Beds
2nd Year
3rd Year
4th Year
5th Year
6th Year
Ventilator Invasive
2nd Year
3rd Year
4th Year
5th Year
6th Year
High Flow Nasal Cannula
2nd Year
3rd Year
4th Year
5th Year
6th Year
Micro - Infusion Pumps
2nd Year
3rd Year
4th Year
5th Year
6th Year
Defibrillator
2nd Year
3rd Year
4th Year
5th Year
6th Year
Portable Suction
2nd Year
3rd Year
4th Year
5th Year
6th Year
Fiber optic Bronchoscope
2nd Year
3rd Year
4th Year
5th Year
6th Year
Incubator
2nd Year
3rd Year
4th Year
5th Year
6th Year
Procedure Light(Portable)
2nd Year
3rd Year
4th Year
5th Year
6th Year
Multi-Para Monitor
2nd Year
3rd Year
4th Year
5th Year
6th Year
Pulse Oximeter
2nd Year
3rd Year
4th Year
5th Year
6th Year
Phototherapy
2nd Year
3rd Year
4th Year
5th Year
6th Year
Refrigerator
2nd Year
3rd Year
4th Year
5th Year
6th Year
Patient Cot
2nd Year
3rd Year
4th Year
5th Year
6th Year
M/S VIJAY AGARWAL AND SONS
M/S VIJAY AGARWAL AND SONS
M/S POPU ENTERPRISES
M/S POPU ENTERPRISES
M/S VIJAY AGARWAL AND SONS
M/S VIJAY AGARWAL AND SONS
M/S VIJAY AGARWAL AND SONS
M/S VIJAY AGARWAL AND SONS
M/S VIJAY AGARWAL AND SONS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid