Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC Awarded as first lowest bidder (L1) | |
| 2 | L2₹36.5 L+₹2.8 L (8.28%)Rejected-AOC | L2 | Rejected-AOC Second lowest | |
| 3 | L3₹42.1 L+₹8.4 L (24.9%)Rejected-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L3 | Rejected-AOC third lowest | |
| 4 | L4₹42.8 L+₹9.1 L (26.9%)Rejected-AOC | L4 | Rejected-AOC forth lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
5 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GERD PASHAN PUNE
GERD PASHAN PUNE
REPAIR AND MAINTENANCE TO EXTERNAL ELECTRIC SUPPLY INCLUDING STREET LIGHT FITTING AND CONNECTED EM WORK AT DRDO ESTATE PASHAN
2023_MES_588441_1
GERD/PSN/TOKEN/08 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GERD PASHAN PUNE
As per tender documents
9 documents required · 9 mandatory
₹500
GERD PASHAN PUNE
₹90,000
Yes
19 May 2023
6 Apr 2023
8 May 2023
6 Apr 2023
5 May 2023
21 Apr 2023
6 Apr 2023 - 14 Apr 2023
Amount
Taking down Insulators any type any description complete all as specified and as directed.
Dismantling and taking down guarding wire complete all as specified and as directed.
Taking out steel tubular swaged poles 11 metre long complete all as specified and as directed.
Dismantling and taking down HT OH line conductor complete all as specified and as directed.
Dismantling cross arms / MS channel from HT pole including clamps, nuts, bolts & washers complete all as specified and as directed.
Supply and fix Pin type, porcelain, vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade complete all as specified and as directed.
Supply and fix insulator shackle type, porcelain, vitreous, white, brown or green insulator including galvanised and mild steel straps of size 31x5mm, washers, insulator bolts, washers and nuts, size of insulator 100 mm height, 115 mm dia with 14 mm dia bolts for 1100 Volts grade complete all as specified and as directed.
Supply and Fix Polymer Pin type insulator of 22 KV including necessary hardware complete all as specified and directed.
Supply and Fix Polymer disc type insulator, ball and socket type, white brown or green suitable for 22KV including necessary hardware complete all as specified and directed.
Material and labour for Cradles, hexagonal / rectangular, fabricated with galvanised steel wire 3.15 or 4 mm complete all as specified and directed.
Supply and fix HT steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 11 metre long complete all as specified and directed. Note : Earth work will measured and paid separately.
Material and labour for aluminium conductor steel reinfoced for over head line, fix on pole bringing the sag with in limit, fixing to the insulator by means of necessary binding with 14 SWG aluminium wire complete all as specfied and directed.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size fixing to existing pole and inclusive of one primer coat, one under coat and one finishing coat of paint as indicated complete all as specified and directed.
Repair and overhauling to gang operated air brake switch device upto 400 Amps,22 KV capacity including use of petroleum gelly for smooth functioning of all moving contacts of GOD complete all as specified and directed. Note : (i) Contractor shall provide All safety tools like HT hand gloves, ladder, rope, safety belt and helmet shall T&P meggar, earth tester and other necessary tools required at site. (ii) Spares required to be replaced shall be measured and paid separately as "Supply only" and fixing charges for the same is deemed to included in the rate quoted for this above item.
Supply only Male contact/moving contact with blade arcing hornof gang operated AB switch devices suitable for 22 KV.
Supply only Female contact /fix contact jaw arcing horn for gang operated AB switch devices.
Supply only Tinned copper flexible jumper 400/200 Amps of suitable length.
Supply only Post top Polymer insulators of gang operated AB switch devices.
Supply only Middle post Polymer insulators of gang operated AB switch devices.
Supply only Bottom post Polymer insulators of gang operated AB switch devices.
Supply only MS jumper carrier.
Supply only GI pipe, heavy grade 25 mm dia made to shape for gang operating from ground.
Material and labour in repair for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 sqmm,22 KV all as specified and directed by Engineer-in-charge.
Material and labour in repair for straight through joint,heat shrinkable,type,for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,185 sqmm,22 KV complete all as specified and directed by Engineer-in-charge.
Material and labour in repair for outdoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, up to 3 core, 185 sqmm 22 KV complete all as specified and directed by Engr-in-charge.
Material and labour in repair for indoor type end termination joint, heat shrinkable, type, for under ground cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE, up to 3 core, 185 sqmm , 22 KV complete all as specified and directed by Engr-in-charge.
Cutting the tree branches which touches the LT/HT OH lines and cleaning 2.5 mtr away from centre line of HT/LT OH line span not exceeding 60 mtrs between poles and deposting the tree branches/leaves at 30 m distance away from site complete all as specified and directed. Note : Any number of tree branches cut in one span will be measured as one spare for payment purpose.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out/laying of HT/ LT under ground cable and getting out in the following type of earth stata complete all as specified and as directed:- Soft soil
Hard/ Dense soil
All as per item No 28 here-in-before but depth exceeding 1.5 metre and not exc 3.0 metre depth in any type of soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soils complete all as specified and directed.
Removing surplus excavated soil to a distance not exceeding 50m depositing where directed at a level not exceeding 1.5metre above the starting point complete all as specified and directed.
Material and labour for dry crushed stone sand filling in trenches to required width at bottom and top of cable cushioning including spreading leveling complete all as specified and directed. Note : Punned thickness shall only be measured and paid.
Supply and lay in trenches reinforced precast concrete cable cover class HV type 2 ,flat size 300 x 180 x 40mm for cable protection complete all as specified and directed by the Engr-in-Charge.
Material and labour for GI tube, , light grade with necessary fittings, complete, fixed to walls, pole ceiling or laid in trenches for cable protection complete all as specified and directed for the following size of pipe:- NOTE :- Excavation and earth work where required shall be measured separately. MS Clamps for fixing on wall / pole , etc are included in the unit rate. 100 mm dia bore
80 mm dia bore
40 mm dia bore
Supplying, laying, jointing, testing and commissioning 22000 volts grade, 3 core 120 Sq mm HT XLPE shielded core type wrapped with galvanised steel strip armoured (earthed), PVC sheathed, heavy duty, electric cables, with multistranded aluminium conductor suitable for 22 KV 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including taking down existing unserviceable cable complete all as specified and directed. Note: Earthwork and cable covers will be measured and paid separately.
Supplying, laying, jointing, testing and commissioning 22000 volts grade, 3 core 185 Sq mm HT XLPE shielded core type wrapped with galvanised steel strip armoured (earthed), PVC sheathed, heavy duty, electric cables, with multistranded aluminium conductor suitable for 22 KV 3 Phase AC, 50Hz, ISI marked, laid in trenches/passing through pipe/duct/ road crossing or fixed on poles, walls with suitable size clamps made out of mild steel flat iron including jointing material such as crimping type lugs, brass cable glands, heavy duty double compression type etc., including taking down existing unserviceable cable complete all as specified and directed. Note: Earthwork and cable covers will be measured and paid separately.
On load filteration of transformer oil by contineous circulation of transformer oil through mechanical filters to achive the desired dielectric strength of 35 KV for one minute at 4 mm gap of sphere of oil testing by machine complete all as specified and directed. Note: .Oil samples are to collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration to be deposited to AGE E/M office for records.
Supply and topping up transformer oil of dielectric strength 50 KV at 4 mm gap in transformers of various cap installed in various locations complete all as specified and directed. Make of Transformer oil: Savitha/ Poweroil/ HP Notes : (a) New Transformer oil shall be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer. (b) Transformer oil shall be supplied in sealed barrel with test result and test certificate.
Supply and fix in repair breather assembly transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia with suitable reducers/connectors etc as per site requirement /capacity of transformer complete all as specified and directed. Note : Rate quoted shall be deemed to include the cost of modification if any required to fix on existing MS Pipe.
Repairs to drop out fuse complete of upto 400 Amps,22 KV capacity including replacement of worn out nut bolts,washers,of suitable size /unserviceabele spares and jumper connections for smooth functioning of the devices complete all as specified and directed by Engr-in-charge. Note : Unserviceable spares and jumper connections replaced shall be measured and paid seprately as "Supply only"
Supply only the following items:- (a) Top contact for drop out fuse.
(b) lower contact for drop out fuse.
(c) Post insulators of drop out fuse.
Material and labour for ACSR conductor (Ferret) jumper connections of following lengths both ends secured with suitable aluminium lugs as per site requirement encased with polythylene sleeve, RYB colours of suitable dia complete all as specified and directed for :- a) Not exceeding 0.75 metre length.
b) Exceeding 0.75 metre length but not exceeding 1.5 metre length.
c) Exceeding 1.5 metre length but not exceeding 2.5 metre length.
d) Exceeding 2.5 metre length but not exceeding 3.0 metre length.
Supply install testing and commissioning in replacement of 22 KV outdoor type Polymer based gang operated air brake switch triple pole, suitable for verticle mounting complete , GI operating rod of suitable length for operating mechanism worked from ground level complete in both OFF and ON positions, for current rating upto 200 Amps,each pole consist of galvanised steel base HT insulators as per BSS/ISS non ferrous knife and spring loaded contacts, arcing horns of adequate section to brake magenetizing current of the transformers. All ferrous parts hot dipped galvanised and non ferrous parts tinned to withstand weather complete all as specified and directed.
Supply and Fix in repair Polymer based dropout fuse unit complete set suitable and including for 22 KV, HT outdoor and dropout type of capacity 200 Amps including jumper connections with copper flexible designed jumper and testing and commissioning complete all as specified and directed.
Material and labour for preperation of old painted steel surface of 6/4/2 pole structure HT/LT street light/HT steel tublar poles 8.5/9.0/11/13 mtr long above GL/coping including cross arms,channels,Flat iron,Clamps in LT/HT OH line by scraping with wire brush/ sand paper and applying one coat of aluminium paint including pole numbering complete all as specified and directed by Engr-in-charge for the following types:- a) HT 6 Pole structure 11 mtrs long including channels, nut, bolts and clamps complete all as specified and directed.
b) HT 4 Pole structure 11 mtrs long including channels, nut, bolts and clamps complete all as specified and directed
c) HT 2 Pole structure 11 mtrs long including channels, nut, bolts and clamps complete all as specified and directed
d) HT pole 11 mtrs long including channels, nut, bolts and clamps complete all as specified and directed
e) LT pole 8.5/9 mtrs long including channels, nut, bolts and clamps complete all as specified and directed
Disconnecting the Pole mounted/platform mounted outdoor type transformer situated at various sub station 22/ 0.433 KV 3 phase under DRDO Estate area of any make and transporting to workshop for repairs/ rewinding, Dismantling the transformer and accessories, removing insulating oil, taking out the core assembly, taking out the defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire/ copper strip of existing size, providing new insulation, sleeves for outlet connections including tap changer switch connection on all 3 phase, opening the complete core assembly, reassembling, including dehydration and filtration of Transformer oil to achieve desired dielectric strength, carrying out routine test, re-installation and commissioning. The repair work also includes the routine tests i.e. IR value, High voltage test, Ratio test, Short circuit test & BD value of oil of the transformer to be carried out at workshop for 100 to 250 KVA complete all as specified and directed. Notes : (i) Copper winding wire/strip will be measured and paid separately as supply only. (ii) Insulating oil for topping up will be measured and paid separately. (iii) Transportation of transformer for repair and re-installation including connection on HT & LT side, testing and commissioning is deemed to include in quoted rates. (iv) Test result to be submitted after testing of transformer.
Supply only super enamelled copper winding wire of various gauges or existing specifications for repair and rewinding of transformers HT coil with insulation including necessary class of insulation complete all as specified and directed.
Supply only DPC copper strip of various gauges or existing specifications for repair and rewinding of transformers LT coil with insulation including necessary class of insulation complete all as specified and directed.
Material and labour for carrying test for acidity of Transformer oil for various Transformers at DRDO Estaste and Test result to be submitted after test complete all as specified and directed.
Disconnecting the transformer outdoor type from HT/ LT system and opening carefully by draining out transformer oil upto HT/LT boxes for rectifying the leakage by replacing the unserviceable spare parts of capacity 50 to 500 KVA transformer, refilling the transformer oil and complete assembling after repairs including testing for any oil leakages and connecting the HT/LT system after the leakages have been rectified and tested on available electric load complete all as specified and directed. Note : (i) Defective parts replaced will be measured and paid separately as "Supply only" items here in after. (ii) Rates for required nut, bolts and washer to be included with quoted rates by contractor.
Supply only LT bushings with brass studs of existing specification.
Supply only top cover gasket set.
Supply only radiator flanged gasket 6 mm thick.
Supply only oil level indicator gasket set.
Supply only HT bushing with stud 22 KV of existing specification.
Supply and fix 22 KV Cable Terminal protector Right angle boot to prevent flashover/short circuit due to intervention by Reptiles complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of old painted surfaces of transformer, removing rusted scale/oil & painting of transformer with one coat of synthetic enamel paint of approved make duly Marking/ Writting MES/SM No. complete all as specified and directed for : 100 to 250 KVA capacity of transformer.
300 to 500 KVA capacity of transformer.
Material and labour for disconnecting HT incoming/ Out going for servicing, opening, draw out VCB/RMU trolley complete from its position and inspection of complete operating mechnical system, electrical wiring system of AC/DC and complete mechanical calibration of breakers including vaccum cleaning, oiling and greasing to all spares, Checking by draw out mechanism/arrangement of VCB/ RMU, inspection of isolating Contacts and decarabanising the male /female contacts, jaws complete and Checking of alignment with spout and setting of contact gaps complete all as specified and directed. Note :- (i) Rate for removal of moisture from breaker by using vaccum cleaner and heating arrangement deemed to be included in quoted rate (ii) Major spare parts shall be paid seperately as supply only items here in after, however cost of minor spares shall be deemed to be included in rate quoted.
Supply only following spare parts:- (a) Spring charge motor single phase 110/220 volts
(b) Closing Coil 110Volt DC
(c) Tripping Coil 110Volt DC
(d) Top spout with Busbar 22 KV.
(e) Bottom spout with Busbar 22KV.
(f) Power pack
(g) Push button for open and Close.
(h) Micro switches
(j) Indication lamps.
(l) Heaters 200 watts single phase 220 volts along with thermostat to be connected on existing wiring circuits
(m) Non hydroscopic, track resistance, high strengh epoxy Bus supporting insulators 22 KV as per existing size and shape
Calibration and testing of combined inverse time over current earth fault and instantaneous relay for checking and cleaning and ensure physical healthiness with visual check for healthy tripping of over current earth fault setting tripping timer ratio setting instantaneous time setting etc as per installed capacity RMU/ Transformers with artificial current injection on primary and secondary with current injection complete all as specified and directed. Note : (a) Contractor shall engage authorized persons for calibration of relay with all necessary equipment. (b) Record of relay setting time for each relay and breaker shall be maintained by contractor and handed over to department.
Material and labour for 22 KV HT cable Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the UG XLPE cabling system for rectifying defects and test report to be submitted complete all as specified and directed. Note: Quoted rate shall include for attending the test without time restrictions.
Material and labour for 22 KV HT Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the over head lines system for rectifying defects and test report to be submitted complete all as specified and directed. Note: Quoted rate shall include for attending the test without time restrictions.
Material and labour for 22 KV HT Hi-Pot Testing ( High potential, high voltage test) with high voltage AC/DC Instrument and find out fault/weak points in the HT structure 2/4/6 poles and its controlling system for rectifying defects and test report to be submitted complete all as specified and directed. Note: Quoted rate shall include for attending the test without time restrictions.
Re-Stringing of HT/LT over head conductor and earth conductors and visual testing of insulator, winding of ACSR as per requirement at site and GI earth wire guard/ earth conductors rigidly with winding wire complete all as specified and directed.
Supply and fix in repair CT 100-75/1 Amp class 1.0 burden 15VA secondary connection 1S1-1S2 suitable for HT 22 KV STC-25KA for 1 sec as per specification with installation calibration and testing complete all as specified and directed.
Supply and fix in repair CT 100-50/1 Amp class 1.0 burden 15VA secondary connection 1S1-1S2 suitable for HT 22 KV STC-25KA for 1 sec as per specification with installation calibration and testing complete all as specified and directed.
Supply and fix power connector accessories made out of aluminium alloy according to IS:617 : 1975 and conforms to IS: 5561 : 1970 galvanic corrosion free heavy duty working pressure 22 KV , enough to carry electrical load and to withstand the mechanical forces imposed during installation as well as service condition and the arrangement of bolts & washers such that the pressure is uniformly distributed over the whole contact surfaced area complete all as specified and as directed for following type of clamps:- Make : Jaipuria Brothers or techno commercial equivalent. (a) PG clamps suitable to connect conductor to conductor
(b) Pad connector suitable to pin insulators and aluminium bus bar
(c) T connector suitable to connect aluminium bus bar to conductor
(d) Expansion type connector for multiple connection
Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 2.50Amp to 25 Amp complete all as specified and directed. Make : Jaipuria/ Biecco/ Lawrie
Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 40 Amp complete all as specified and directed Make : Jaipuria/ Biecco/ Lawrie
Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 75 Amp complete all as specified and directed. Make : Jaipuria/ Biecco/ Lawrie
Supply only DO fuse element end soldered standard tinned copper wire solder joint with ferrule and fire resistant ceramic tube suitable for 22 KV size 100 Amp complete all as specified and directed. Make : Jaipuria/ Biecco/ Lawrie
Material and labour for disconnecting from existing main taking out from LT panel board for servicing & overhauling LT panel/ LT ACB panel of any make 400 to 1000 Amp, 50Hz 415V AC including taking out existing mechanism complete with servicing of operating machnism, testing of triping mechanism complete to make it functioning smoothly and including replacement of unserviceable spares and fixing in its original postion with all connections and testing complete all as specified and directed. Note : Spare parts shall be paid separetly under respective items as supply only here in after.
Supply only Following spare parts suitable for LT ACB 400A-1000 A Capacity. (a) Main isolating contact (Male and Female) jaw type complete inclubing fixing accessories
(b) Shunt Trip coil/ Closing coil 415 VAC suitable for 800 amps ACB
(c) Under voltage tripping device (UVT) 415 volts
(d) Single phae CTS at rating 800/5A
Supply and fix in repair MCCB 4pole, 400 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed. Make : Legrand / L&T / C&S /ABB/ Havell's
Supply and fix in repair MCCB 4pole, 250 Amps, 36 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed.
Material and labour in repair for MCCB 4pole, 200 Amps, 25 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed. Make : Legrand / L&T / C&S /ABB / Havell's
Material and labour in repair for MCCB 4pole, 100 Amps, 25 KA, 415 volts, over load and short circuit protection, adjustable thermal -magnetic release type complete all as specified and directed. Make : Legrand / L&T / C&S /ABB / Havell's
Supply and fix in repair, connect, test and commissioning of LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium multi stranded aluminium conductor heavy duty 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following sizes including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings/walls without cable duct) complete all as specified and directed by the Engr-in-Charge for the following :- Notes : (i) Excavation, sand cushioning, cable protection will be measured and paid separately under relavant item here in before . (ii) Cost of jointing material e.g. lugs, glands, thimbles, nut bolt and washers shall include in quoted rates. (a) 25 Sqmm 4 core
(b) 16 Sq mm 4 core
Supply and lay in trenches reinforced precast concrete cable cover class LV, Type I, flat, size 250 mm x150mm x 40mm for cable protection complete all as specified and directed by the Engr-in-Charge.
Material and labour for finding fault of UG cable aluminium conductor armoured of any size, by fault locator complete all as specified and directed. Notes : (i) Excavation/earth work/returning filling/relaying of brick and relaying soft soil for cushioning deemed to be included in the rate quoted. (ii) Cable for rectification will be measured and paid under relevant item. iii) Joint kit required will be measured and paid separately under relevant item. (iv) The rate quoted is deemed to include for the hire charges fo fault locator. Before starting the LT/ HT wire, contractor shall ensure safety arrangement and proper shut down of feeders / mains to avoid any unwanted incidents.
Material and labour for straight through joint for UG cable including joint kit for making joint suitable for the following size complete all as specified and directed :- (a) 10 sq mm to 16 Sq mm, 2 core
(b) 16 sq mm to 25 Sq mm, 4 core
(c) 35 to 95 Sq mm, 3.5 core
(d) 120 to 150 Sq mm, 3.5 core
Material and labour for PCC 1:3:6 type C-2 using 40mm graded aggregate as in foundations of stays and poles, copping of poles etc complete including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Material and labour for earth testing at various sub station complete all specified and directed by Engr-in-Charge : Note : Earth tester of suitable size and necessary arrangement will be done by contractor. Note: Record of earth resistance value to be submitted to Engr-in-Charge.
Material and labour for Earthing complete with hot dip galvanized steel pipe in pipe electrode, outer pipe 76 mm dia medium grade and inner pipe 32 mm dia including testing. 3 mtr long and having 50x6 mm terminal on inner pipe to connect earthing strip with 14 mm dia holes for nut bolts. buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.3 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32 x 6 mm strip with minimum two Nos of GI nut, bolts and connected to test point from earthing pit. The electrode pipes should be filled with 2x 25 Kg bags of carbon based earthing compound. The compound shall be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities! with ph value between 7-9, connected to the earthing test point, fiber reinforced plastic pit not less than 300x300 mm with pit cover, including necessary returning, filling and removal of extra soil. NOTE: (i) GI strip beyond 7.5 metre will be measured and paid sepeartely. (ii) Resistance of earthing should not more than 2 Ohm. Test report shall be prepared and submitted by the contractor in triplicate duly obtaining signatures of MES JE / AGE & PMG / user. Test results are to be written in letters of 20mm height in white colour on black paint back ground. If the desired result not obtained after testing, the contractor shall do re-eathing without any extra cost to Govt.
Material and labour for Earth contunity conductor or main earthing lead fixed to wall on recessed or burried in ground or drawn in conduit/pipe fixed to poles or any other indicated situation for loop earthing as required 32x6 mm size galvanised strip complete all as specified and directed.
Supply and fix LT steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55, 09 metre long complete all as specified and directed. Note : Earth work shall be measured and paid separately.
Supply and fix in repair LED street light /road way luminaries 45 watts with pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed. Make : Havells Cat ENDURASUNDOWNSL45WLED765PASBOPC OR Techno commercial Equivalent in CG/ Jaquar
Supply and fix in repair LED street light /road way luminaries 60 watts with pressure die cast housing heat sink with IP 66 protection, interchangeable electronic driver high efficiency longer life, protection against high surges , high /low voltage cutoff, open/short circuit protection and high power factor LEDs as light source including fitted on existing street light pole bracket complete all as specified and as directed. Make : Havell's Cat ENDURAOMINIPLUSSL60WLED757SASYOPC OR Techno commercial Equivalent in CG/ Jaquar
Supply and fix in repair LED 25Watt post top lantern (gate light) energy saving, environment friendly designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete all as specified and directed. Make:- Havell's cat part No RUBYPT25WLED757PSYMTOPC or Techno commercial equivalent in Bajaj/ Philips
Supply and fix in repairs of street light bracket made out of 40mm dia medium grade GI pipe of 1.5 Mtr long bend to shape including necessary MS clamps, nuts & bolts and applying two coats of aluminium pait over a coat of red primer painting complete all as specified and directed.
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 140x140x100mm internal comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in & loop out suitable for single phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron complete all as specified and directed. Make : Sintex/National or techno commercial equivalent
Supply and fix in repairs pole junction box sheet moulded compound (SMC) type with hinged door and locking arrangement of size 300 X 200 X 105 mm (internal ) comprising one , one No SP MCB single pole of capacity 6 Amps 240 volts and one No terminal for loop in & loop out suitable for three phase street light system including nuts and bolts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron complete all as specified and directed. Make : Sintex/National or techno commercial equivalent
Material and labour for 3 single core 2.5 sqmm PVC insulated unsheathed copper conductor cable multistranded taking down passing through in steel pole DB to street light luminaires including replacing the un serviceable complete all as specified and directed. NOTE :- 3 run of cable shall be measured as one length
Supply and fix in repair Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 8 kW single-Phase load .Contactor Rating: 40.Amps ( 2-pole ).MCB (single-pole) Rating:63.Amps (2 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (EnC Approved) Contactor: BCH/L&T/Schneider MCB: Hager/Schneider/Legrand/L&T. Make:SWADEEP – 02EC 8kW1P/Suntech - ST 01
Supply and fixing in repair Automatic Street Light Switch using NATURE SWITCH for automatic switching of Street Lights based on LUX level of Natural Light. The Sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54.The Contactor, MCB and Circuit Wiring should suitable enough to take load of 12 kW load equally distributed over 3-phase .Contactor Rating: 40.Amps (4-pole).MCB (single-pole) Rating: 40.Amps (3 nos.) Nature Switch: Kakatiya Energy Systems Pvt. Ltd. Hyderabad (E-in-C Approved) Contactor: BCH/L&T/Schneider MCB: Hager/Schneider/Legrand/L&T Make:SWADEEP – 02EC 12kW3P/Suntech -ST 02
Material and labour for cutting of roads/ plinth of width and depth not exc 0.25 metre for removal/ lalying of pipe complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-1 by using 20mm graded crushed stone aggregate as in foundations of for making good road/ foot path/ hard standing/ drain/ bldg plinth protection complete all as specified and directed.
Material and labour for straight through joint,heat shrinkable,type,for HT OH AB cable including joint kits and labour complete for making joints suitable for aluminium conductor cable XLPE,3 core,95 to 185 sqmm,22 KV complete all as specified and directed by Engineer-in-charge. Make : M seal/ Denson Note: Joint for 3 core will measure one unit only. Contractor should quote rate accordingly.
Material and labour for fabrication of out door type LT panel doors of any size as site requirement with locking arrangement made out of any size / thickness mild steel sheet and duly fixed/ welded with suitable size butt hinges including making good to the disturbed surface of panel complete all as specified and as directed.
Material and labour for painting of indoor/ out door type LT panel by synthetic enamel paint two coats including scrapping old paint from panels and making good to the disturbed surface of panel complete all as specified and as directed.
Material and labour for fabrication and installation of Glow Sign Board in size 1828.8mm x 1219mm x 177.8mm made of Flex/ Acrylic board, with digital contents all as by directed Engineer-in-charge at one side of the board, GI plain sheet not less than 1mm thick cubical open the flex/Acrylic board and suitable for mounting on wall /gate complete all as directed by Engineer-in-Change. Note :- The rate quoted is deemed to include for fabrication and welding and fixing all as directed.
Borole Electricals
M/S - KRUPA ELECTRICALS
SOURABH ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .