Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC SANTOSH NAGAR COLONY LACHHIPUR BARGADWA GOKAKHPUR UP 273015 | GOKAKHPUR | GORAKHPUR | UP | 273015 | ₹14.8 L Quoted ₹12.5 L | L1 | Accepted-AOC The L1 bidder is techno-commercially qualified. The quoted rate has been accepted by the Competent Authority, NK Area with APSD. |
| 2 | L2₹18.2 LRejected-Finance | ₹18.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹19.1 LRejected-Finance 0 ADITYA ENTERPRISES 0 UNNAO HARDOI ROAD KISHORI KHERA UNNAO UTTAR PRADESH UNDER NAGAR PALIKA UNNAO UTTAR PRADESH 209801 | UNNAO | UTTAR PRADESH | 209801 | ₹19.1 L | L3 | Rejected-Finance L3 |
| 4 | L4₹24.0 LRejected-Finance | ₹24.0 L | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | M/S ADITYA ENTERPRISES L3 | SHIVAM INDUSTRIES L1 | BARBRIK TRANSFORMERS L2 | M. K. ELECTRICAL WORKS L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Cost of TPC copper wire for one limb Primary and Secondary Coil (Total weight of coil of all three limbs primary and secondary coil is 3970kg; Primary 2383 kg and Secondary 1588 kg). Weight of one limb of primary and secondary coil is 1323. | 1,323 | kg | 1,563 ₹20.7 L | 1,300 ₹17.2 L | 1,500 ₹19.8 L | 1,620 ₹21.4 L |
| 2.00 | Insulation material for all three limb primary and secondary winding | 1 | job | 3,10,177.35 ₹3.1 L | 25,000 ₹25,000 | 1,95,000 ₹1.9 L | 2,75,000 ₹2.8 L |
| 3.00 | Labour charge for all three limb primary and secondary winding including to and fro transportation | 1 | job | 3,10,177.35 ₹3.1 L | 3,50,000 ₹3.5 L | 4,00,000 ₹4 L | 3,25,000 ₹3.3 L |
| 4.00 | Replacement of complete gasket of conservator, Radiator, Top cover, inspection chamber, on load tap changer with cleaning of tanks etc. | 1 | job | 35,120 ₹35,120 | 15,000 ₹15,000 | 60,000 ₹60,000 | 1,25,000 ₹1.3 L |
| 5.00 | Filtration of Transformer oil | 6,820 | Ltr | 28 ₹1.9 L | 10 ₹68,200 | 10 ₹68,200 | 18 ₹1.2 L |
| 6.00 | Providing and fixing of Magnetic Oil Level Gauge Dial Size 150 mm Housing and Body pressure Die Cast with powder coated for Transformer conservator with air cell and magnetic coupling. | 1 | Nos | 25,700 ₹25,700 | 5,000 ₹5,000 | 30,000 ₹30,000 | 45,000 ₹45,000 |
| 7.00 | Providing and fixing of Buchholz Relay Aluminium Pressure Die cast with mercury switches for Alarm and trip, Powder coated, 75 mm dia | 1 | Nos | 24,631 ₹24,631 | 5,000 ₹5,000 | 10,000 ₹10,000 | 65,000 ₹65,000 |
| 8.00 | Providing and fixing of Winding temperature Indicator with Trip, Non Trip and Alarming system having Capilliary Tube length 5 meter long and calibrated as per Neutral CT | 1 | Nos | 27,600 ₹27,600 | 2,000 ₹2,000 | 11,000 ₹11,000 | 18,000 ₹18,000 |
| 9.00 | Providing and fixing of Oil temperature Indicator with Trip, Non Trip and Alarming system having Capilliary Tube length 5 Meter long. | 1 | Nos | 27,600 ₹27,600 | 2,000 ₹2,000 | 11,000 ₹11,000 | 15,000 ₹15,000 |
| 10.00 | Providing and fixing of Marhsaling Box with Terminal Box with 16 pin connectors. | 1 | Nos | 14,995 ₹14,995 | 10,000 ₹10,000 | 25,000 ₹25,000 | 90,000 ₹90,000 |
Tender Value
₹26.5 L
EMD Value
₹33,100
Closing Date
18 Apr 2026, 5:00 pmClosed
SO EnM NK
GM OFFICE, NK AREA
Repairing and rewinding of 10 MVA, 33kV/11kV-6.6kV Transformer, 3 Phase, Make Kirloskar, Sl. No. 82VG-002/1 under KDH Project, NK Area
2026_CCL_357934_1
GM (NK)/EnM/e-NIT/2026-27/ 01
Open Tender
Electrical and Maintenance Works
60 days
KDH OCP, NK AREA
As per NIT
2 documents required · 2 mandatory
₹33,100
29 May 2026
3 Apr 2026
20 Apr 2026
4 Apr 2026
18 Apr 2026
4 Apr 2026
4 Apr 2026 - 10 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
Cost of TPC copper wire for one limb Primary and Secondary Coil (Total weight of coil of all three limbs primary and secondary coil is 3970kg; Primary 2383 kg and Secondary 1588 kg). Weight of one limb of primary and secondary coil is 1323. | - | kg | - | - | item01 | |
| 2 | Insulation material for all three limb primary and secondary winding | - | job | - | - | item02 |
| 3 | Labour charge for all three limb primary and secondary winding including to and fro transportation | - | job | - | - | item03 |
| 4 | Replacement of complete gasket of conservator, Radiator, Top cover, inspection chamber, on load tap changer with cleaning of tanks etc. | - | job | - | - | item04 |
Filtration of Transformer oil | - | Ltr | - | - | item05 | |
Providing and fixing of Magnetic Oil Level Gauge Dial Size 150 mm Housing and Body pressure Die Cast with powder coated for Transformer conservator with air cell and magnetic coupling. | - | Nos | - | - | item06 | |
| 7 | Providing and fixing of Buchholz Relay Aluminium Pressure Die cast with mercury switches for Alarm and trip, Powder coated, 75 mm dia | - | Nos | - | - | item07 |
| 8 | Providing and fixing of Winding temperature Indicator with Trip, Non Trip and Alarming system having Capilliary Tube length 5 meter long and calibrated as per Neutral CT | - | Nos | - | - | item08 |
Providing and fixing of Oil temperature Indicator with Trip, Non Trip and Alarming system having Capilliary Tube length 5 Meter long. | - | Nos | - | - | item09 | |
| 10 | Providing and fixing of Marhsaling Box with Terminal Box with 16 pin connectors. | - | Nos | - | - | item10 |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx